Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹18.9 LAccepted-AOC FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | L-1 | Accepted-AOC LOWEST TENDERER | |
| 2 | L-2₹20.6 L+₹72,969 (3.68%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L-2 | Rejected-Finance GREATER THAN L1 | |
| 3 | L-3₹25.8 L+₹6.0 L (30.3%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L-3 | Rejected-Finance GREATER THAN L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
4 Nov 2021, 6:00 pmClosed
P Bangar Raju,IDSE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
REPAIR / MAINTENANCE OF INTERNAL ELECTRICAL WIRING AND CONNECTED WORKS IN SMQ AREA, KASTURI HOSPITAL, NSB AREA AND PRATAB NAGAR AREA AT INS SHIVAJI, LONAVLA
2021_MES_481980_1
GE/LONAVLA/8024/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) (NAVY) LONAVLA
As per NIT /Tender documents
6 documents required · 6 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹60,000
Yes
4 Dec 2021
14 Oct 2021
6 Nov 2021
14 Oct 2021
4 Nov 2021
22 Oct 2021
14 Oct 2021 - 21 Oct 2021
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete,(fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for issue under Schedule of credit and making good disturbed surfaces of walls, floors, etc.
Taking down MCB DBs / SFUs
M & L for point wiring with 1.5 sq mm single core FRLS PVC insulated cable 1100 V grade with multistranded copper conductor drawn through PVC casing and capping with all accessories fixed to wall /roofs ceiling etc and incl provision of 1.5 sq mm PVC insulated and unsheathed copper conductor as earth continuity conductor and connected to common earth dolly incl fabricated steel terminal box made out of 1.6 mm thick MS sheet concealed in the wall with 3 mm thick laminated sheet top cover / PVC Switch Board mounted on wall for mounting the switches , socket outlets , fan regulators etc all as s specified and directed for following. (a) One light/Fan point controlled by one switch.
All as per item no 3 above but One socket 3 pin outlet 5 amp on independent board.
All as per item no 3 above but One 3 pin socket outlet 5 amp on the same board board with other switches.
All as per item no 3 above but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size.
All as per item no 3 above but with copper conductor cable for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm.
S&F in repairs switch piano flush type single pole one way 5 amp.
S&F in repairs ceiling rose three terminal/PVC polycarbonate, isolated body complete all as specified.
S&F in repairs switch socket combination 2 in 1, 3 pin 5/15 amp flush type. .
S&F in repairs switch socket combination 2 in 1, 5 amp flush type.
S&F in repairs socket outlet 2 in 1, 3/5 pin 5 amp multi purpose, flush type.
S&F in repairs switch bell push, flush type 5 Amp.
S&F in repairs bell, Multi music type AC, 230 Volts single pole.
S&F in repairs fan regulator electronic step type complete all as directed by EIC at site
S&F in repairs LED tube rod for LED Tube light fitting 18 Watt , complete with all accessories complete all as required at site and as directed by Engineer -in-Charge. Make : Cat No BLRB 20 CW LED of Bajaj or equivalent of Havell's/Philips / Wipro
S&F in repairs Batten for LED Tube light 18 Watt fitting prewireed upto terminal block complete with all accessories and connecting up with twin core / .0076 flexible copper wire with and including LED tube light fixed on two nos PVC round / square mounting blocks complete all as required at site and as directed by Engineer -in-Charge. Make : Cat No BLRB DB 118 of Bajaj or equivalent of Havell's/Philips / Wipro .
S&F in repairs Surface mounted 36 watt 2 x 2 luminaire white powder coated CRCA housing with LEDs, Aluminium front frame with flat white high transmission acrylic cover complete with LEDs, driver and standard accessories including neccessary fixing arrangement complete all as required at site and as directed by Engineer -in-Charge. Cat No BCTBLR 36W LED FP CW of Bajaj or equivalent to Philips /CG.
Supply & fix in repairs 45 W pressure die cast aluminium housing LED Building light secondary optics IP 66 protection including connection with two core twisted copper flexible cable, Make - Bajaj, Cat No - ENXT P 54L WH CR PC SD or equivalent make of Havells /Philips/CG
Supply and fix in replacement of LED Tube light of 18/20 watt (4') with batten integrated channel complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.Make:Bajaj CAT Part No BCLAB 20W WH LED P (4ft) or equivalent to CG/Philips/Wipro complete all as specified and directed .
Supply and fix in replacement of LED Tube light of 10 watt (2') with batten integrated channel complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.Make:Bajaj CAT Part NoBCLSB 10 WH (2ft) or equivalent to CG/Philips/Wipro complete all as specified and directed .
S&F in replacement vertical type DB , (VTPN) suitable for and including MCCB 4 pole, 125 amps, 16KA as incoming (compact) Earth and neutral bus bar of capacity upto 200 amp 4 ways,IP 43 protection , shrouded neutral bar & pan assembly with flexible connecting link in the wall with suitable nut and bolt including matching the existing surface all as specified and directed ,
S&F in replacement MCB DB TPN 4 ways double door with 440 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
S&F in replacemen MCB DB SPN 4 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
S&F in replacemen MCB DB SPN 8 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
S&F in repairs MCB DB SPN 12 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
S&F in repairs MCB C Curve SPN 32-63 amps, 240 Volts, Complete all as specified and directed.
S&F in repairs MCB C Curve SP 6 to 32 amps single pole 240 Volts, Complete all as specified and directed.
S&F in repairs MCB C Curve TPN 6-32 Amps , complete all as specified and directed.
S&F in repairs MCB C Curve TPN 40-63 Amps , complete all as specified and directed.
S&F in repairs MCCB FP 125 Amps 16 kA 415 V , wcomplete all as specified and directed.
S&F in repairs MCCB FP 160 Amps 25 kA 415 V , with adjustable thermal and adjustable magnetic release, Complete all as specified and directed.
S&F in repairs MCCB FP 200 Amps 25 kA 415 V , with adjustable thermal and adjustable magnetic release, Complete all as specified and directed.
Taking down sub main wiring of any size from the ceiling, walls etc and incl making good to disturb surface of wall and match with the existing surface.
M&L for sub main wiring drawing through PVC casing and capping with two single core 4 sq mm and one run of 4 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade all as directed. Note:- Three run of 4 sqmm wire and One run of PVC casing caping will be measured as one running meter.
M&L for sub main wiring drawing through PVC casing and capping with four runs of single core 6 sq mm and two runs of 6.0 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade all as directed.Note:- Four run of 6 sqmm wire and Two run of 6 sqmm wire and One run of PVC casing caping will be measured as one running meter.
Supply and fix in repairs Triple pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating upto 32 Apms
Supply and fix in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating upto10/20 Apms
M&L for earthling complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of volts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition.
Supply and fix new adore LED lamp 5 Watt confirming to Cat No LhLDeroemD9X005 of Havell's or euivalent in Philips / Bajaj
Supply and fix new adore LED lamp 9 Watt confirming to Cat No LhLDeueCnL8r009 of Havell's or euivalent in Philips / Bajaj
Supply and fix new adore LED lamp 15 Watt confirming to Cat No LhLDeueCnL9r015 of Havell's or euivalent in Philips / Bajaj
Dismantling the existing energy Meters, MCCB / MCB Distribution boards by disconnecting the eletric supply connection and refixing at new or same location after carrying out repairs / replacement , reconnecting complete all as directed by EIC at site.
Supply and fix in repairs modular switch one way 6 Amps, 1 module complete all as specified and as directed.
Supply and fix in repairs modular socket 6 Amps, 2/3 pin combined 2 module complete all as specified and as directed.
Supply and fix in repairs modular socket 6 Amps/16 Amps, 2/3 pin combined 2 module complete all as specified and as dirceted.
Supply and fix in repairs modular switch 1 way 16 Amps, 1 module complete all as specified and as directed.
Supply and fix in repairs modular bell push 6 Amps, 1 module complete all as specified and as directed.
Supply & fix LED Highbay luminaire 100 Watt along with fixture, complete all as specified and directed at site.Make:Bajaj CAT Part No BGHBM 100W LED XE or equivalent to CG/Philips/Wipro complete all as specified and directed.
Supply and fix in replacement Electronic ballast suitable for 1x36/40 Watt tube light fitting complete all as specified and as directed.
Supply and fix in replacement Electronic ballast suitable for 1x18/20 Watt tube light fitting complete all as specified and as directed.
Supply and fix in replacement Electronic ballast suitable for 1x28 Watt tube light fitting complete all as specified and as directed.
cooltech engineering services
Shree Ayyappa Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .