The Executive Engineer PWD,ECD
O/O The Executive Engineer PWD Electrical Construction Division ,New office Complex Building(5th Floor) Bhabani Bhawan Alipore, Kolkata 700027
Electrical Installation and Arrangement of Air Conditioning work through PWD in connection with the creation of office set up infrastructure for the proposed permanent office space for the Departmental Representatives DR of State Tax at the 6th fl
2025_WBPWD_961872_2
WBPWD/EE-ECD/e-NIQ-44/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Alipore
please refer tender documents
5 documents required · 5 mandatory
₹20,481
O/O The Executive Engineer PWD ECD
5 Mar 2026
21 Jan 2026
19 Feb 2026
21 Jan 2026
17 Feb 2026
4 Feb 2026
21 Jan 2026 - 2 Feb 2026
2 Feb 2026
Supply & delivery of Inverter type split Air-conditioner machine having Cooling Capacity- 5.2 kW (Minimum), min. 3 star rated, noise level not more than 51 db. This Split Air Conditioning machine should be fitted with Rotary/Scroll compressors, LCD remote with battery & all other accessories suitable for Refrigerant- R32 having both condenser & cooling coil made of copper tube, connecting cord with plug top of suitable capacity with indicator(brand approved by E.I.C) conforming to IS:-1391(Part- II) with all ammendments. (Make:- Mitsubishi Heavy Industries/ Mitsubishi Electric/O-General as approved by EIC)
Supply & delivery of casette Air-conditioner machine having Rated/Standard cooling capacity(at 100% load) not less than 13760W, min. 3 star rated, Noise level not more than 49db. This Split Air Conditioning machine should be fitted with Rotary compressors, LCD remote with battery & all other accessories suitable for Refrigerant- R32/R410A, having both condenser & cooling coil made of copper tube etc.(Make:- Mitsubishi Heavy Industries/ Mitsubishi Electric/O-General as approved by EIC) as per approved by EIC).
Installation, testing & commissioning of the above-said split/casette ACs on wall with appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC.
SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft/hard drawn copper refrigerent piping for package RAC system, complete with fittings, with adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XLPE class -O tubular insulation/withClass-O closed cell elastometric nitrile rubber tubular sleevessections of specified thickness as given below for suction andliquid lines, all accessories as per specification etc. as required.
a) 5/8" (15.88 mm.) (for suction) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 19mm thick insulation. (Make- Approved by EIC)
b) 3/8" (9.52 mm.) (for suction) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 19mm thick insulation. (Make- Approved by EIC)
c) 1/4" (6.4 mm) ( for discharge) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 19mm thick insulation. (Make- Approved by EIC)
Supply & Laying of 4 core 1.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c. (Polycab/Gloster/Finolex/Havells /RR Kabel as approved by E.I.C)
Supply & Laying of 3 core 2.5 sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection between Indoor to Outdoor unit of Split type AC m/c. (Polycab/Gloster/Finolex/Havells /RR Kabel as approved by E.I.C)
Supply & Laying of 4 core 4 sq.mm 1.1 KV insulation grade sheathed Cu cable as per direction of EIC for making interconnection between Indoor to Outdoor unit of casette type AC m/c. (Polycab/Gloster/Finolex/Havells /RR kabel as approved by E.I.C)
Supply and laying 25mm PVC pipe (heavy type) for water drainage.(25mmOD, 1mm thick) with proper support & bracket as per direction. (Make- Supreme/Oriplast).
Supplying, fabrication & fixing of outside Iron Structure platform of suitable size by grouting MS u-channel of 6mm thick of size (75 mm x 40 mm x 4.8 mm) for making platform for installation of outdoor unit of Cassette AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6mm and supporting angle of 50 mm x 50 mm x 6mm in each platform. The platform should be baricated & safe for ODU Maintenance in outer edge for transmitting the load centrally through (50 mm x 50 mm x 6 mm) Angle and 20mm x 3mm Flat inserted into the wall. The Area of the platform is of suitable size as per Machine configuration & load with adequate service access as per direction of EIC. The design of platform structure to be approved by EIC.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.86 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.23 MB
Tendernotice_2.pdf
PDF • 0.51 MB
eniq44.pdf
Tender Documents • 1.21 MB
2911.pdf
Tender Documents • 0.50 MB
BOQ_2426910.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .