Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹53.0 LAccepted-AOC UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹55.8 L+₹1.8 L (3.31%)Rejected-Finance | L-2 | Rejected-Finance Being L-2 | |
| 3 | L-3₹60.0 L+₹6.0 L (11.1%)Rejected-Finance SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L-3 | Rejected-Finance Being L-3 | |
| 4 | L-4₹60.6 L+₹6.6 L (12.3%)Rejected-Finance ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | L-4 | Rejected-Finance Being L-4 | |
| 5 | L-5₹63.8 L+₹9.8 L (18.2%)Rejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L-5 | Rejected-Finance Being L-5 |
Tender Value
₹98.3 L
EMD Value
₹1.7 L
Closing Date
19 Sept 2023, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
SPECIAL REPAIRS TO BLDG NOS P-12 AND P-13 OF RESIDENTIAL COLONY AT NAD TROMBAY UNDER GE (NW) MANKHURD
2023_MES_610190_1
8848/E8
Open Tender
Civil Works
Item Rate
270 days
MANKHURD
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
GE (NW) MANKHURD
₹1.7 L
Yes
9 Oct 2023
22 Jul 2023
22 Sept 2023
22 Jul 2023
19 Sept 2023
29 Aug 2023
Amount
SCHEDULE 'A' PART I (B/R WORKS) Taking down cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and removing debris outside MD land. Note: The place of disposal shall be find out by the contractor.
Demolition of brick work or stone/boulder masonry, built in cement mortar, including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work & precast concrete articles including copings etc.and removing debris outside MD land complete all as specified. Note: The place of disposal shall be find out by the contractor.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified.
M&L for rendering 10 mm thick ready mix plaster on fair faces of brick work or concrete surfaces in CM (1:6) and finished even & smooth without using extra cement including necessary scaffolding and safety measures upto 18m height completed all as specified.
M&L for rendering 10 mm thick ready mix plaster on fair faces of brick work or concrete surfaces including dubbing coat to match with existing in CM (1:6) and finished even & smooth without using extra cement including necessary scaffolding and safety measures upto 18m height completed all as specified.
M&L for chipping, removing carefully loose/damaged concrete incl plastering (total thickness upto 60mm ) from RCC surfaces of columns, beams,Chajas, soffits of slabs etc by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land, complete all as specified and directed. Note: Hard concrete shall not be removed by force.
M&L for cleaning existing reinforcement by sand blasting with suitable pump as directed by the GE and wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed . Note:- Mode of measurement: superficial area of concrete will be measured.
M&L for TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with the clips or welding if required as in various structural RCC elements like column, beams and Slab etc. complete all as specified and directed. Note: This item is applicable for additional bars required in the existing RCC structures.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application complete all as specified and directed.
M&L for building up the profile of structural members by using Polymer mortar HB of Dr Fixit, while the bonding agent is still tacking upto 20mm thickness including levelling, profiling etc complete all as specified and directed.
M&L for building up the profile of structural members by using Polymer mortar HB of Dr Fixit, while the bonding agent is still tacking upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed.
M&L for casting & repairing of excessively damaged distressed RCC members (exceeding 60mm in thickness) with prebatched, prepacked, single component ready to use microconcrete from Fosroc (Renderoc RG) or equivalent of Dr. Fixit as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications and all other relevant worksincl scaffolding upto 18 mtr height complete all as specified and directed. (Note : Reinforcement only shall be measured and paid separately).
M&L for leakage / seepage proof coating consisting of preparing the new surfaces of existing exterior walls, parapet walls, chajjas etc. and applying Primeseal primer of M/s Dr Fixit or equivalent chemical of M/s STP Ltd as approved by the GE or one coat of Chemstic PDE 600 elastomeric coating (and allowing to dry for 8hrs) under torch dry condition and subsequently applying two coats of water proofing decorative elastomeric coating system Raincoat of M/s Dr Fixit with DFT 100microns or Shalicryl 215 of M/s STP Ltd or Chemstic PDE 600 elastomeric coating (the surfaces after painting one coat shall be allowed to dry for 6 to 8hours before application of next coat) including necessary scaffolding etc complete all as per manufacturer instructions and all as specified & directed. Notes: (i) The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE.
M&L for prepration of newly plastered surfaces of wall, applying wall care putty not less than 3mm thickness and making the surface even and smooth using emery paper and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified..
M & L for preparing old decorated surfaces of wall & applying one coat of white wash complete all as specified
M & L for preparing old decorated surfaces of ceiling & applying one coat of white wash complete all as specified
M & L for complete removal of existing treatment including washing, rubbing down and stopping of distempered and painted wall surfaces, filling holes and cracks with filling putty on wall and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified..
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar including removal of rubbish out side MD land. Note: The place of disposal shall be find out by the contractor.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc. 0.11 sqm but not exceeding 0.18 sqm, in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick CM 1:6 screed bed for laying floor finishes complete all as specifed and directed..
M&L for coloured glazed ceramic tiles of size 350x 250x 6-7 mm/ 450X 350X 6-7mm thick as in skirting, dado, set and jointed in neat cement paste and pointed in coloured cement to match the shade including backing coat 10 mm thick in cement mortar (1:4) complete all as specified. etc complete all as directed and specified.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc. 0.18 sqm but not exceeding 0.38 sqm, in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick CM 1:6 screed bed for laying floor finishes complete all as specifed and directed..
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection 75mm thick, with expansion joints & top surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for 18 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, and fixed to timber framework with screws including dismantling existing prelaminated particle board of any description complete all as specified.
Demolition of lime concrete or lean concrete from sunken floor including floor tiles, hacking of surfaces after cleaning with wire brush (floor and adjoining walls) and disposing off debris outside MD land complete all as specified and directed. Note: The place of disposal shall be find out by the contractor.
M & L for filling of lean concrete 1:5:10 type E2 (using 40 mm graded stone aggregates ) in sunken portion, as per requirement complete all as specified and directed.
M&L for PCC 1:2:4 type-B1 (using 20mm graded stone aggregate) in any position mixed with WPC @ 2% by weight of cement complete all as specified and directed. Note: WPC will be measured and paid separately.
M & L for special treatment for sunken portion of WCs/Bath & toilet etc executed in following stages : Stage 1: Providing 15mm thick plaster in CM 1:3 mixed with water proofing chemical of Dr.Fixit or Shalicrete 'R' of STP Ltd in the proportion/quantity all as per manufacturer's instructions. State 2 : Primer-Mix Tarfelt LM of STP Ltd (diluted with water in ratio 1:1) @ 250 gms/sqm and apply the primer on the plastered surfaces. Stage 3 : Application of 1st coat of Tarfelt LM of STP Ltd (without dilution with water) @ 1Kg/Sqm by brush all as per manufactuer's instructions. Stage 4: Laying fyber glass cloth (weight not less than 50gram/ Sqm) over the 1st coat while the coated surface is still sticky. Stage 5: After 6 to 7 hours interval, apply second coat i.e. final coat of Tarfet LM of STP Ltd (without Dilution with water) @ 1kg/ Sqm by brush as per manufacturer's instructions. Stage 6: Providing 10mm thick protective plaster in CM 1:3 mixed with STP No. 1 @ 250ml/50 Kg cement all as per manufacturer's instructions. Stage 7: Carryout ponding test for 48 hours to ensure water tightness of repaired sunken portion. NOTES :(i) Mode of measurement: Actual area treated (floor and adjoining walls) will be measured and paid . (ii) The above treatment shall be got executed through applicator of manufacturer and necessary authenticated documents on account of above shall also be produced by the contractor.
Taking up or down steel water tubing and connections of 15mm bore complete all as specified and directed.
Taking up or down steel water tubing and connections of 20mm bore complete all as specified and directed.
S & F 16 mm outer diameter CPVC pipe SDR 11 & Plain CPVC SDR 11 fittings (including provision of special fittings i.e. brass elbow, brass tee, Male brass threaded adaptor, female brass threaded adaptor etc required for fixing of bib tap, stop valve with CPVC pipes) concealed in walls/ ceiling or laying in floors etc., including cutting chases, grooves and making good the disturbrd surfaces in CM 1:3 after fixing of pipes / fittings complete all as specified and directed.
S&F 20 mm bore GI tubing medium grade with all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc fixed to walls and ceilings or laid in floors with suitable size GI clamps complete all as specified.
S&F 40 mm bore GI tubing medium grade with all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc fixed to walls and ceilings or laid in floors with suitable size GI clamps complete all as specified.
S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm dia out let including grating connecting jointing to waste pipe including taking out existing unserviceable trap by hacking out concrete joints and making good disturbed surfaces complete all as specified and as directed .
S&F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified.
S&F in repair Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified.
S&F in repairs low level PVC flushing cistern (coloured) of heavy duty, 9 Ltrs capacity, syphonic action type complete with inlet, ball valve, float and handle including cast iron bracket, PVC connections 15 mm bore with two brass nut & rubber washers 450 mm long and 32 mm bore PVC flush pipe and connecting to WC complete all as specified.
S&F in repairs15 mm bore bib tap, cast copper alloy chromium plated, fancy type with crutch or butter fly handle screwed down, screwed for iron pipe complete all as specified.
S&F in repairs 15 mm bore two bib tap, cast copper alloy chromium plated, fancy type with crutch or butter fly handle screwed down, screwed for iron pipe complete all as specified.
S&F in repairs 15 mm bore pillar taps cast copper alloy chromium plated fancy type with capstan heads screwed down high pressure with or without lettered `Hot' or `Cold' with long screwed shanks and fly nuts screwed for iron pipe or brass ferrule complete all as specified..
S&F in repirs 15 mm bore stop valve cast copper alloy, chromium plated, fancy type with long shank screwed down high pressure concealed type with crutch or butterfly handle screwed both ends for iron pipes or union complete all as specified.
S&F in repairs Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified.
S&F in repairs Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) including shower arm 15 mm size, 195mm long with bend of 45 degree with flange of PTMT any colour.(Minimum weight 40gms complete all as specified.
S & F in repairs health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 mtr long flexible tube and ABS hook including making all connections and fixed in position complete all as specified.
S&F in repairs wash hand basin vitreous china flat black type of size 580 mm x 450 mm coloured, CI brackets and 32 mm dia PVC waste coupling including cutting for and pining in ends of bracket and connecting up supply pipes, waste or taps complete all as specified
S&F in repairs stainless steel soap dish of standard size fixed to wall with chromium plated brass screws complete all as specified
S&F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including screed bed or bedding layer of cement morar 15 mm in 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade including dismantling of existing stone/ tiles of any description complete all as specified and directed
M&L for Marble work 18 to 20mm thick of any colour as directed (table rubbed and polished) as in steps, jambs, pillars, window cills, cooking platforms and like (in one piece) in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade laid over and including screed bed or bedding layer of cement mortar 15 mm )1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade dismantling of existing stone/ tiles of any description complete all as specified and directed
M&L for 35 to 40 mm thick machine cut, machine polished cuddappa stone slab as in platform for fixing oval shape wash hand basin (including cutting the slab to oval shape to accomdate the sink and WHB), pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of stone slab including moulding/rounding to edges of the slab including dismantling of existing stone/ tiles of any description complete all as specified and directed
M&L for Machine cut kota stone slab 20-25mm thick as in flooring, treads, risers, landing etc over and including 15mm thick cement mortar screed in (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including dismantling of existing stone/ tiles of any description complete all as specified and directed
-Ditto- all as per item No. 51.00 above but except stone including mirror polishing complete all as specified and directed
M&L for rounding to edges of stone slabs exposed edge as in steps, cooking platform and other similar situations complete all as specified and directed
M&L for hacking out old broken glass (any thickness, size, quality or description) from metal frame/aluminium frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones.
Taking down carefully existing aluminium sliding window shutters and taking out broken 4 mm thick plain sheet glass from aluminium sliding window shutters including rubber gasket complete, supply and fixing 4 mm thick plain sheet glass with and including rubber gasket and re-fixing the shutter in existing position complete all as specified and directed.
Taking down carefully existing aluminium sliding window shutters, taking out stainless steel wire mesh including rubber gasket and supply and fixing Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples with and including provision of "U" clip and re-fixing the shutter in existing position complete all as specified and directed.
Taking down carefully aluminium sliding window shutters from the frames or chowkhat and supply and fix new locking arrangement in existing position and re-fixing the shuter in existing position complete all as specified and directed
S& F in repairs 20mm dia aluminium anodized tubular curtain rod complete all as specified.
S&F in repairs aluminium anodised brackets suitable for 20mm dia curtain rod fixed with cadmium plated screws complete all as specified.
S&F in repairs PVC (SWR) pipe 110mm bore single socketed in any length with rubber ring joint fixed to wall with suitable size PVC clamps by maintaining 30 mm clear gap between finished wall surface and pipe complete all as specified and directed.
-Ditto- all as per item No. 61.00 above but 75mm bore
S&F Vitreous china squatting pan orrisa pattern of size 580 x 440mm with integral foot rest and 'P' or 'S' trap including lime concrete bedding connecting flushing pipe including taking out old WC pan with lime concrete and unserviceable connections and making good floor as per existing complete all as specified and as directed
S&F in repairs Vitreous china Wash down water closet (Pedestal pattern) white (excluding fixing bolts, flushing cistern and flush pipe) with 'P' or 'S' trap including making all connections complete all as specified and as directed
Removing plant/growth including its roots upto 1.00m of plant height at any location/at any storey and of any description and treating the surfaces with Acid (HCL) and making good surfaces with cement mortar 1:4, complete all as specified and directed.
S&F 110 mm bore PVC(SWR) bend any radius, diminishing pieces or tapers (Large bore will be measured) with rubber ring joints.
S&F 75 mm bore PVC(SWR) bend any radius, diminishing pieces or tapers (Large bore will be measured) with rubber ring joints.
S &F 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal with rubber ring joints.
S &F 75 mm bore PVC (SWR) junction single, (Single T) equal or unequal with rubber ring joints.
S &F 110 mm bore PVC (SWR) branch piece, single (single Y) equal or unequal
S &F 75 mm bore PVC (SWR) branch piece, single (single Y) equal or unequal
Taking down chowkats or frame with shutters ( without taking off shutters from the frame ) exceeding 1.5 Sqm but not exc 4 Sqm each complete all as specified and directed.
Taking down chowkats or frame with shutters ( without taking off shutters from the frame ) not exc 1.5 Sqm each complete all as specified and directed.
M&L for second class hardwood (SAL) plain, solid straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified.
Taking down shutter of any description exc 1 Sqm but n.exc 2 Sqm each and refixing in same opening complete all as specified and directed.
M&L for 30 mm thick second class hard wood (Sal) glazed and skeleton shutters open rebated and prepared to receive glass, gauze, (without sash bars) edges of framing plain chamfered or rounded fitted to cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part-I Section 8 Clause 8.20 (b) complete all as specified.
S&F in repairs stainless steel wire cloth 0.36mm mm nominal dial of wire and average width or aperature 1.40mm fixed to wooden door/ window shutters in any position with new beads/ steel section as required for securing complete all as specified and directed.
S&F 35 mm thick second class hard wood (Hollock) factory made plain framed panelled shutters (any numbers of panels) with panels of 12 mm thick veneered particle board exterior grade medium density with commercial veneering on both faces with sheesham wood beading all round the panel made out of 20 mm x 15 mm , on one side and fitted to chowkhats complete all as specified and as directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with Square tube, supply and fixing in opening as per specification given under SSR Part II 2010 including making good the disturbed surface all as specified and directed.
M&L for factory made solid PVC panel type PVC door shutter 30mm thick consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rails, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent supplying and fixing in the frame at site as per specifications and drawing given under SSR Part II 2020 complete all as specified and directed.
S&F 100 mm long stainless steel butt hinges fixed with stainless steel screw
S&F aluminum anodised barrel tower bolts of extruded section of size 150 mm length
S&F aluminum anodised barrel tower bolts of extruded section of size 200 mm length
S&F 150 mm extruded aluminum alloy handles, fabricated type anodised
S&F aluminum anodised sliding door, bolts with hasp and staple ( bolt type ) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminum alloy, length of bolt 250 mm.
M&L PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in bed blocks for fixing hold fast, bed plate, coping, surface chanels etc including including weathering slightly rounded or chamfered angles, throating and necessary form work complete all as specified and as directed.
M&L for preparing new wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified.
M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10 cm width or girth & applying one coat of synthetic enamel paint complete all as specified.
Demolition of cement concrete (unreinforced) of any description and in any position including existing roof/ terrace, chajja etc including removing/taking down existing water proofing treatment of any thickness and cleaning the surfaces with wire brush, washing out with water to remove loose particle and removing the debris out side MD land complete all as specified and directed. Note: The place of disposal shall be find out by the contractor.
M&L for rendering 10 mm thick in CM (1:3) mixed with WPC @ 2% by weight of cement on concrete surfaces on roof and finished even and smooth without using extra cement complete all as specified. Note : WPC will be measured and paid separately.
Taking down existing APP membrane of any description wire brushing, scrubbing down with water to remove all dirt, dust etc. and applying APP based polyster membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application complete all as specified with the following specifications complete all as specified and directed:- (a) Applying oil bound bitumen primer @ 0.40 litre/ Sqm manufactured by the same manufacturer as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on the prepared dry surface. (b) Laying APP modified water proofing membrane reinforced with non woven polyester fiber weight not less than 160gm/Sqcm using butane torch by torch application with 10cm side lap and 15cm end lap. (c) Physical properties of membrane shall be as under:- (i) Membrane weight not less than 3.50 Kg/Sqm. (ii) Non woven polyester weight not less than 160gm /sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650N/Sqcm and transverse not less than 450 N/Sqcm (v) Tear strength-longitudinal not less than 300 N & transverse not less than 250 N. (vi) Elongation : > 20% in both directions. (vii) Impermeability/water tightness at 2 Kgf/cm2. (viii) Water absorption - Not more than 1% on mass within 24 hours. (ix) Cold flexibility - Minimum (-) 20C. (x) Dimensional stability % change = Maximum 1%. (d) Over the membrane provide a finishing with solar reflective bitumen aluminum paint @ 0.10 Kg/Sqm as prescribed by manufacturer. (Note :- Bitumen primer paid separately)
M&L for preparation of old painted steel surfaces of any description not otherwise described over 10 cm width or girth & applying one coat of synthetic enamel paint complete all as specified.
Taking down aluminium frame with shutters (without taking off shutters from the frames) with all fittings but excluding grills complete all as specified and directed.
S&F standard aluminium section powder coated (minimum thickness of powder coating shall be 50 micron and colour shall be as approved by GE ) as in frame and shutters of doors,window,ventilators, fixed / openable / sliding or any pattern, cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass, provision of hinges, screws, plugs, handle, lock, roller, Nylon ball bearing etc complete all as specified and directed . Note:- Weight of Aluminium sections as per actual or as per IS or as per manufacturer whichever is less shall only be considered for payment. Cost of other items / accessories required for entire completion of the work shall be deemed to be included in the quoted rate. However glass panes and SS wire cloth shall be measured and paid separately as supply only under respective item.
Supply only 4mm thick sheet glass, ordinary quality fixed in aluminium window complete all as specified and directed
Supply only Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples in aluminium windows complete all as specified and directed .
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F mild steel bands, straps , supports or stays for rain water, ventilating pipes including bolts, clamps, hold fasts and similar small articles confirming to Fe-410-0 or Fe-310-0 complete all as specified & directed.
S&F mild steel framed work such as grills, gratings etc, with ends of bars shouldered or rebated or forged into spikes, framed guard bars, barred iron doors, railings, framework of water tanks and similar work conforming to Fe -290 Grade -E-165 complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of existing roof sheet of any description complete all as specified and directed.
M&L for preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified.
Taking down existing aluminium grills from balcony or any locations complete all as specified and directed.
S&F aluminium anodised Grills of approved design for window / ventilators and fixing with F/U channel including drilling as required in RCC sections in rectangular or architectual type balcony opening in existing building, complete all as specified and directed. Note: The Grills shall be of Model DG-100/DG-102 of Make Deco or equivalent make as approved by the GE.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:4) and finished fair and even completed all as specified.
S&F cast iron covers and frame grade FG 150 unmachined as in manhole covers including locking arrangement including removing old U/s covers & frames complete all as specified
M&L for 75 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base and finished fair and even complete all as specified.
M & L Chequered cement concrete Endura tiles 200mm x 200mm x 25mm thick glossy finished , set, jointed and pointed in neat cement slurry as in floors laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified.
M&L for cutting chases in brick walls pining in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of wall, steps, cills, sunshades lintel etc. and making good disturbed surfaces, cutting exc 20 cm width or girth.
M&L for 5 mm thick polymer modified ready mix cement based plaster on surfaces of ceiling including finishing the surface even & smooth without using extra cement, complete all as specified and as directed. Make : Easy plast from M/s wall plast or chemplast or Readiplast from ultratech. Note: The thickness of plaster specified above is the minimum thickness and the quoted rates shall also be deemed to include for provision of dubbing of the surfaces with the ready mix plaster and nothing extra shall be payable on this account.
M&L for preparation of newly plaster surface of ceiling two coats Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/liter, of approved manufacturer, of required shade and colour Incl 2 mm plaster of paris putty complete, as per manufacturer's specification.
SCHEDULE 'A' PART I (E/M WORKS) Taking down copper/ aluminium point wiring (Light/Fan/Socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, socket, light fitting etc. and making good disturbed surfaces of walls, floors, ceiling as per existing complete all as specified and directed.
M & L for point wiring with PVC insulated unsheathed 1100 Volts grade single core multistranded copper conductor cable 1.5 Sqmm drawn through and including PVC casing-caping and accessories of required size fixed on wall / ceiling etc with neccessary fixing accessories and earth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 2 mm thick pressed steel terminal boxes concealed in wall covered with laminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws all as specified for the following: One light / fan / bell point controlled by one switch.
All as per item No. 112.00 above but One 5A 2pin/3pin socket out let multipurpose on the same board with other switches.
All as per item No. 112.00 above but One 5A 2pin/3pin switch socket out let multipurpose on independent Board.
All as per item No. 112.00 above but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board
Supply & Fix switch piano single pole flush type 5A, 240 V one way complete all as specified and directed.
Supply & Fix Bell push flush type 5 amp, 230 Volts complete all as specified and directed.
Supply & Fix switch socket combination 2 in 1 , 5 Amps multipurpose flush type.
Supply & Fix switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal.
Supply & Fix Ceiling rose surface bakelite three terminal, 240 V complete.
Supply & Fix electronic regulator Step type 2 module type 240V suitable for ceiling fan complete.
Supply and fix bell ding dong AC 230 V single pole complete all as specified and directed.
Supply and fixing in replacement Surface, hanging and wall mounted batten (Double side connection) suitable for LED tube 20/22 watts, 230 volts alongwith tube rod 20/22 watt (double side connection), including fixing mounting blocks 2 Nos, 15 mm MS conduit, 1.5 sqmm 3 core pvc insulated copper conductor cable including fixing arrangements complete all as specified and directed. Note : “LM 79 & LM 80 Test certified from NABL certified Lab shall be submitted by the contractor for LED luminaries along with warranty certificate for 2 years”.
Supply and fixing in replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including provision with three core flexible copper conductor cable of suitable size and PVC square blocks complete all as specified and directed
S & F Angular Holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings etc. all as specified and directed.
S & F LED Light Bulb 8/9 watt of white colour pin type, 230 V complete all as specified and directed.
Taking down old unserviceable ceiling fan 1200 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades and transporting to workshop to undertake repairs by rewinding of burnt out winding using suitable gauge copper wire, replalcement of worn out capacitor 2.5 mfd - 01 No., PVC canopy - 02 No's and bearing including scrapping of old paint and applying two coats of synthetic enamelled white paint over a coat of red oxide primer complete and refixing back at site complete all as directed.
Taking down old unserviceable Exhaust fan 300 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades and transporting to workshop to undertake repairs by rewinding of burnt out winding using suitable gauge copper wire and bearing including scrapping of old paint and applying two coats of synthetic enamelled white paint over a coat of red oxide primer complete and refixing back at site complete all as directed.
S&F single pole and neutral enclosure with a two pin and earth and metal clad plug socket complete with one single pole MCB 20 Amp 240 Volts complete all as specified including concealing in wall and directed. Make :- LEGRAND/ SCHEINDER/ L&T
Supply & Fix in repairs MCB DB Double Door SPN 12 way 240 volts complete all as specified and directed.
M&L for MCB SP, 240 volt, 6 to 32 Amps, 10 KA 'C' series complete all as specified and directed.
M&L for MCB SPN, 240 volt, 32 Amps, 10 KA 'C' series complete all as specified and directed.
S&F in repair/replacement of building Security light fitting 30/35 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr- in – charge.
S& F in replacement of GI steel tubing medium grade 40 mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 32mm x5mm flat iron, nuts , bolts, etc all as directed by Engineer in charge
M&L for sub main wiring with two single core 6.0 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 6.0 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly including taking down old unserviceable submain wiring complete all as specified and as directed Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.
M&L for sub main wiring with two single core 4.0 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 4.0 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly including taking down old unserviceable submain wiring complete all as specified and as directed Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.
M&L for sub main wiring with two single core 1.5 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 1.5 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly including taking down old unserviceable submain wiring complete all as specified and as directed Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.
M & L for rewiring of old burnt out copper wiring in LT Panels/LT Feeder, replacing of cable Glands, cable lugs, bus bar link, connectors, insulators, door hinges, panel door locks & scrapping of old paints & spray painting inside and outside applying two coat of synthetic enameled paint of superior quality and approved colour after preparation of steel surface all as specified and diredted. Location:P-12 NAD Colony
Supply install, test and commissioning of Powder coated LT Feeder panel cubical out door type Channel mounted compartmentalized in construction all Confirming to IS 8623 Part 1 1993 CPRI approved factory fabricated made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB and TPN Copper bus bars, incomer MCCB and outgoing MCCB, MCB, Contactors The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB. The cubicle shall have a bottom channel & free standing frame made of angle iron of size not less than 40mm X 40mm X 6mm ut of A detachable predrilled gland plateof thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side.The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire and consisting the following, including taking down of old unsv panel after disconnecting Existing cables, Existing energy meters and re fixing the energy meters at new panel & Reconnecting the cables to new panels and including PCC foundation, excevation, grouting bolts. Location P-13 at NAD Colony a) Electrolyte Copper bus bar 200 Amps for 3 phase and Neutral b) MCCB TP 100 Amps 415 Volt 16 KA - 1 Nos c) MCB TPN 40 Amps, 10 KA 415 Volts- 1 Nos d) MCB SPN 40 Amps, 10 KA 230 Volts - 11 Nos e) Space for Fixing 11 Nos of Single Phase Energy Meter of Capacity 40 Amps, f) LED RYB Indicators - 1 Set g) Ammeter - 0-200 Amps - 01 No h) Voltmeter - 0-500 Volt - 01 No i) Internal wiring of Panel complete using suitable size copper wires/ flexibles Note- The lay out drawing of the panel shall be got approved by the contractor before panel fabrication from GE and shall be fabricated from CPRI approved manufacturer.
M&L for earthing using GI earthing strip 32 x 6mm complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deep below ground level connection to and including GI strip of size 32x6mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm madium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm B61x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick with one lifting handle made of 8mm dia MS bar funnel wie mesh and testing on completion including making test point on wall as per SSR specification all as specified and directed.
S & F LED light fitting 1X10W Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
M&L for earthing using GI earthing strip 32 x 6mm complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deep below ground level connection to and including GI strip of size 32x6mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm madium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick with one lifting handle made of 8mm dia MS bar funnel wie mesh and testing on completion including making test point on wall as per SSR specification all as specified and directed.
ORIENT ELECTRIC CO
Parmatma Enterprises
mp construction co
Vishal Builders
RAJU AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .