| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹28.8 L+₹1.4 L (5.09%)Rejected-Finance | L2 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
10 Jul 2021, 6:00 pmClosed
GE North Bangalore
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
REPAIRS TO JOINERY PLUMBING FLOORING AND REPAIRS REPLACEMENT OF INTERNAL WIRING ELECTRICAL FITINGS FIXTURE IN THE MD ACCN BUILDINGS AT BANASWADI AREA IN THE AOR OF AGE B R MEG UNDER GE NORTH BANGALORE
2021_MES_445084_2
8225
Open Tender
Civil Works
Item Rate
150 days
BANASWADI
Class E category a(i)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹25,000
Yes
12 Aug 2021
21 Jun 2021
12 Jul 2021
21 Jun 2021
10 Jul 2021
28 Jun 2021
21 Jun 2021 - 27 Jun 2021
Amount
PART I ( B/R WORKS)
Dismantling of Asbestos cement (corrugated, semi corrugated, etc.) sheets as in roof coverings including ridges etc complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specified and as directed.
Dismantling timber scantlings 40 sq.cm and over in section, in any position in unframed work complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Dismantling of structural steel work including doors, gates but excluding framed truss etc. complete all as specified and as directed
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards /slabs / blankets, any thickness, including cover fillets etc complete all as specified and as directed.
Demolition of brick work / stone masonry / PCC block masonry built in cement mortar of any description all as specified and as directed.
Demolition of cement concrete and paving not exc. 15 cm thick (below or above ground level) complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not specifically provided for complete all as specified and as directed.
Dismantling water tanks of any type and removing to store, capacity exc. 250 litres and not exc. 500 litres all as directed.
Dismantling water tanks of any type and removing to store, capacity exc. 500 litres and not exc. 1000 litres all as directed.
Taking down steel tubing of 15 mm dia bore & connections including cleaning for refixing serviceable pipe or removal of balance pipe to store complete all as specified and as directed.
All as per Sl Item No. 1.012 above but 20 mm dia of bore pipe.
All as per Sl Item No. 1.012 above but 25 mm dia of bore pipe.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and as directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc (laid bedded and pointed in any cement mortar) including removing off the premises etc complete all as specified and as directed.
Dismantling of stone sett paving of any description or thickness in floors, aprons etc., laid bedded and pointed in any cement mortar including removing off the premises etc complete all as specified and as directed.
Taking down cement plaster of any description hacking for key or raking out joints on old brick work / stone / concrete surfaces complete all as specified and as directed.
Taking down chowkats or frames with shutters without taking off shutter from frames area not exc. 1.5 sqm each, including cutting holes for removing the hold fast etc and making good the distrubed surface of wall complete all as specified and as directed.
Taking down chowkats or frames with shutters without taking off shutter from frames area exc. 1.5 sqm but n.exc. 4 sqm each, including cutting holes for removing the hold fast etc and making good the distrubed surface of wall complete all as specified and as directed.
Taking down shutter of any description area exc. 1.00 sqm and not exc. 2 sqm each and re-fixing in same opening etc complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden surface concrete or brick surrounds, glazed with putty or fixed with beads all as specified and as directed.
Taking down PVC / cast iron soil waste pipe / rain water pipes of any size or pattern including all fittings, head shoes, etc complete all as specified and as directed.
Rolled mild steel work as in tubular trusses, purlins etc., including special shaped washers etc., complete using ERW or incduction butt weld tubes conforming to IS-4923 complete all as pecified and as directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specifed and as directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering cladding to wall, fixed with self taping screwes as specified and as directed.
6mm thick asbestos cement, corrugated or semi corrugated sheets in roof coverings with J or L hook or cranked bolts all as specified and as directed.
Asbestos cement sheets two piece adjustable plain wing ridge 6mm thick all as specified and as directed.
Decorated PVC false ceiling of size 600mm x 600mm x 5 mm thick, used as a panel insert in a frame work made out of anodized aluminum T-section of size 25mm x 25mm in square pattern of grid size 600mm x 600mm aluminum frame work, supported from the ceiling with the help of J jook and 4 mm dia GI wire of required length to maintain the proper levels etc and the aluminum frame work is supported on side wall with the use of aluminum L section of size 25mm x 25mm angle complete all as specified and as directed.
Plain Cement Concrete (1:4:8), type D-2 using 40mm graded stone aggregate as in sub base to floors, 75mm thick complete all as specified and as directed.
Plain Cement Concrete (1:2:4), type B0 using 12.5mm graded stone aggregate, 25mm thick as in levelling course of flooing etc., complete all as specified and as directed.
Non skid ceramic coloured tiles 7-8mm thick(square/rectangular) area of each tile exceeding 0.06 sqm but n.exc 0.11 sqm as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Non skid ceramic coloured tiles 7-8mm thick(square/rectangular) area of each tile exceeding 0.18 sqm but n.exc 0..38 sqm as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Vitrified light coloured ceramic tiles 8 to 10mm thick (square/rectangular) polished, area of each tile not exc. 0.36sqm in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM (1:6) for layaing floor finishes complete all as specified and as directed.
Glazed coloured ceramic tiles as in vertical surfaces / dado 300x450x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including backing coat 10mm thick in CM (1:4) on fair faces of brick work or concrete surfaces complete all as specified and as directed.
All as per Sl Item No.1.033 & 1.034 above but as in skirting including backing coat 10mm thick in CM 1:4 complete all as specified and as directed.
18 to 20mm thick Granite stone slab, black colured of any type, table rubbed and polished as in steps, jambs, pillars, window-cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. including grinding the edges half round and polishing to match over and including 15mm thick screed bed in CM (1:6) for layaing floor finishes complete all as specified and as directed.
Plain Cement Concrete, type C-1, (1:3:6) using 20 mm graded crushed stone aggregate, 75mm thick as in plinth protection, laid in alternate bays (not exceeding 2 sqm each) finishing the concrete surfaces even and smooth at top without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight all as specified and directed.
Chequered cement concrete designer tiles of size 300mm x 300mm x 25mm thick, exterior grade, coloured, glossy finish, rubber pressed, set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles over and including 20mm thick screed bed in CM (1:6) as in floors etc., complete all as specifed and as directed.
M-sand as approved as in cushioning material laid and spread in floors complete all as specified and directed.
Machine presssd pre-cast cement concrete interlocking coloured paver blocks of glass fibre reinforced, glossy finished, vibro compacted of any shape and size conforming to IS-15658-2006 of 60 mm thick, M-35 grade with grey cement and pigment complete all as specified and as directed.
1.25 mm thick pressed steel frame of size 165 x 60 mm for door with one ore more rebate includings necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed.
Second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
Plain Cement Concrete (1:2:4), type B1, using 20mm graded stone aggregate as in copings, bed blocks, hold fasts, chajja kerbs, roof padding / staging of water tank etc including necessary formwork, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
35mm thick flush shutters, solid core construction with decorative choice lamination on both sides of shutter, kiln seasoned and chemically pressure treated complete all as specified and as directed.
Factory made second class hard wood 35 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze,etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, size of members of shutters as specified in SSR Part-1, Section 8, clause 8.24 (a) kiln seasoned and chemically pressure treated complete all as specified and as directed.
18/19 mm thick prelaminated particle board, exterior grade, prelaminated both sides with decorative choice lamination, fixed with screws to timber frame work as in cupboard shutters, shelves, kitchen cabinet including teak wood lipping of size 18/19 mm width and 10 mm thick complete all as specified and as directed.
PVC solid door frame, single rebated of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete as sepecified and directed. NOTE:- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life.
Factory made solid PVC moulded door shutter with wood free EPS, 28 to 30mm thick (stiles) with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face and 2mm plain colour PVC sheet on back face etc. complete all as specified and as directed.
Powder coated aluminium frame for doors, windows, ventilators with minimum thickness of powder coating 50 micron, with one or more rebates including joining cleat for fixing etc., complete all as specified and as directed.
Powder coated aluminium window and ventilator shutters with minimum thickness of powder coating 50 micron, fixed type without sash bars, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and as directed. NOTE:- Glass and wire mesh shall be measured and paid separately under respective items.
Powder coated aluminium door shutters with minimum thickness of powder coating 50 micron, aluminium sections weighing 0.55 kg/ m including necessary joining cleats,glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed. NOTE:- Glass shall be measured and paid separately under respective items.
Box type Steel windows/ventilators double side shutters (windows side hung type, ventilators top hung type) pressed steel frames made out CRC Sheet of 80x60x1.25mm double rebated, shutters box type made out of CRC Sheet of 40x20x1.0mm , windows & ventilator shutters shall be of glass and gauge type, fixed with box type hinges, aluminium die cast handles for glass shutters, Iron flat type handles for mesh shutters, telescopic stays, etc complete all as specified including 12mm square guard bars/grill welded with steel frame (100c/c horizontically) all as specified and directed by Engineer-in-Charge. NOTE: (i) Payment under this item will be make combined for steel frames, steel shutters and Guard bard/Grill, However unit rate quoted shall deemed to include cost of beading, fittings such as handles, hinges,Telescopic stays, locking arrangements. (ii) 4 mm thick sheet glass and wire mesh be measured and paid separately. (iii) Weight of Grill/Guard Bars, handle,hinges and locking arrangements shall not be accounted for payment purpose . (iv) All Windows/Vent design as per CECZ TD drg No 539.
Rolled Mild steel work in hand rails, half round or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters, running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc, wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or rivetting, etc, and similar work conforming to Fe-410 Gde E-250 complete all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia and average width of aperture 1.40mm and fixed with stainless steel wire staple all as specified and as directed.
4 mm thick sheet glass, ordinary quality and glazing with oil putty and glazing clips in metal frame and second class hard wood beading in wooden frames in squares not exceeding 0.5 sqm in each pane all as directed.
5.5mm thick sheet glass, ordinary quality and glazing with oil putty and glazing clips in metal frame and second class hard wood beading in wooden frames in squares exceeding 0.5 sqm in each pane all as directed.
4.00mm thick figured glass, pin headed type and glazing with oil putty in square not exc. 0.50 sqm each panes complete all as specified and as directed.
Aluminium anodised tower bolt 200 mm long of extruded section etc complete all as specified and as directed.
Aluminium anodised tower bolt 150 mm long of extruded section etc complete all as specified and as directed.
Aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc complete all as specified and as directed.
100 mm thick stainless steel butt hinges, heavy weight, and fixed etc complete all as specified and as directed.
150 mm long aluminium handle, cast type, anodised etc complete all as specified and as directed.
150 mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floors etc., complete all as specified and as directed.
300mm long, brasss ordinary rat tail rod pattern springs including roller and roller plate etc., complete all as specified and as directed.
Aluminium extruded section body door closer, hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and as directed.
Precast cement concrete block masonry with solid blocks exc. 10 cm in width and setting in cement mortar 1:6 type C1 1:3:6 ( using 20 mm graded aggregate) complete all as specified and as directed.
Rendering 5mm thick on concrete surfaces of ceiling / chajja / facia of chajja etc in CM (1:3) finished even and smooth without using extra cement all as specified and as directed.
15mm thick rendering on brick or concrete surface in cement mortar (1:6) and finishing the surface with even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick in CM(1:4) mixed with water proofing compound as per manufacturers instructions finishing the surfaces even and smooth without using extra cement including necessary scaffolding complete all as specified and directed. NOTE:- WPC will be measured and paid separately under reelvent items.
Supply only integral liquid water proofing compound all as specified and as directed.
Demolition of existing roof treatment of any type including cement plaster 10 mm thick and PCC 25mm thick and providing screed bed/rendering 10mm thick in CM (1:4) mixed with and including supply of approved water proofing compound as per manufacturers instructions over and including 25mm thick (average) PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) by removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth and providing 50mm x 50mm coving at the corners with PMC mortar as above, and applying APP modified water prrofing membrane as per IS 1654-2017/IS 16352-2017 mineral finish, 3mm thick and weighing not less than 3.60kg/Sqm reinforced with non woven polyster/HMHDPE matt black finished over compatible primer/bonding bitumen @ 0.40 Litr/Sqm and torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface complete as per manufacturer's instructions and applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sqm complete all as specified and directed.
Galvanised iron pipe of 15mm dia, medium grade, laid floors / fixed to wall with all fittings such as socket, bends, elbow, union etc., complete all as specified and as directed.
20mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, fixed to wall, ceiling or laid in floors including all fittings and specials complete all as specified and as directed.
Galvanised iron pipe of 20mm dia, medium grade, laid floors / fixed to wall with all fittings such as socket, bends, elbow, union etc., complete all as specified and as directed.
25mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, fixed to wall, ceiling or laid in floors including all fittings and specials complete all as specified and as directed.
Galvanised iron pipe of 25mm dia, medium grade, laid floors / fixed to wall with all fittings such as socket, bends, elbow, union etc., complete all as specified and as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 500 ltrs complete all as specified and as directed.
All as per Sl Item No 1.078 above but except tanks. NOTE:- Serviceable tanks as obtained from Sl Item No. 1.010 above shall be reused.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 1000 ltrs complete all as specified and as directed.
All as per Sl Item No 1.080 above but except tanks. NOTE:- Serviceable tanks as obtained from Sl Item No. 1.011 above shall be reused.
20mm dia ball float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed inrepairs (min weight 20mm-210 gms) all as specified and as directed.
Gun metal gate or globe valves 20 mm dia with iron wheel head, screwed both ends for iron pipe and fixed in repairs complete all as specified and directed
Gun metal gate or globe valves 25 mm dia with iron wheel head, screwed both ends for iron pipe and fixed in repairs complete all as specified and directed
Providing and laying water proofing treatment to sunken portion of WCs, bathroom and kitchen etc by applying cement slurry mixed with two component elastomeric acrylic based polymer modified cementitious composite compound coating of make as approved in TI 5/2003 including demolition and removal of existing treatment of any type with the following procedure in sequence all as specified and as directed:- (i) Demolition of existing treatment of any type including cleaning and removal of debris from site. (ii) First layer of cement slurry @ 0.488 kg/sqm of cement mixed with acrylic based polymer modified cementitious composite compound @ 0.253 kg/sqm, the layer will be allowed to air cure for 4 hours. (iii) Second layer of cement slurry @ 0.242 kg/sqm of cement mixed with with acrylic based polymer modified cementitious composite compound @ 0.126 kg/sqm, the layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (iv) 20mm thick screed in cement mortar (1:3) mixed with including supply of liquid water proofing compound as per manufacturers instructions. Contd.. 1.086
Contd.. from 1.085 (v) Ponding the treated portion atleast 48 hours, if any leakage / seepage observed the entire procedures will be repeated without any extra cost. (vi) Provide 40mm dia light grade GI spout at the lowest point with 30cm projection beyond the out face of the wall. (vii) Sunken portion shall be filled with lean cement concrete(1:5:10), type E-2 using 40mm graded stone aggregate. NOTE :- (i) The sunken slab sloped towards outer face to drain the water in to GI spout pipe. (ii) Coving shall be provided at the junction of slab with the wall. (iii) Nahni trap shall be 10mm below finished floor level and drain pipe dia is larger than the nahni trap size. (iv) The outer end of the spout should be chamfered.
Vitreous china wash basin white, flat back, size 550 x 400mm excluding taps, waste, chain & plug and porcelain stopper but including brackets, 32 mm bore waste stainless steel coupling and LDPE pipe of 600 mm long including fixed in repairs complete all as specified and directed.
Vitreous china wash down water closet pan (Pedestal Pan), coloured, including fixing bolts, flush pipe anti syphonage pipe, plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device etc complete of cera model cat pt no. 2008 including fixed in repairs complete all as specified and as directed.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including PVC(SWR) 'P' or 'S' trap connecting to flush pipe and to anti syphonage pipe, etc. complete including making good to floor fixed in repairs complete all as specified and directed.
Viterous China urinals, bowl type, back or corner wall type of size 465x355x265 mm white (minimum), complete fixed in repairs including providing and fixing plugs, bedding to urinal against wall in cement mortar(1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; supply and fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and directed.
PVC valveless, syphonic action type, flushing cistern, 10ltr capacity,low level, white, with inlet, ball valve, float and handle including brackets, connections to pipes and fixing of chain and pull, or lever, fixed in repairs complete all as specified and directed.
15mm bore pillar taps, fancy type, cast copper alloy, with long swan neck, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe and fixed in repairs complete all as specified and as directed.
15mm dia Pillar tap PTMT fancy type any colour screwed, for iron pipe and fixed in repairs complete all as specified and as directed.
Bib taps 15mm dia, fancy type, cast copper alloy chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule fixed in repairs complete all as specified and as directed.
Bib taps15 mm dia, fancy type, long body, standard of PTMT any colour high pressure screwed for iron pipe and fixed in repairs minimum weight 120gms complete all as specified and as directed.
Wall mixer, brass chromium plated for mixing hot and cold water screwed down for iron pipe of 15mm dia all as per Prayag cat No-7875 URBONA or techno commercially equivalent makes specified in PS fixed in repairs complete all as specified and as directed.
Sink mixer with swinging casted spout, wall mounted model with connecting legs and wall flanges of 15 mm bore all as per Prayag cat No-7855 URBONA or techno commercially equivalent makes specified in PS fixed in repairs complete all as specified and as directed.
15 mm dia single lever basin mixture, tall height with out pop up waste system all as per Prayag Cat No. PIS-7852 URBONA or techno commercially equivalent makes specified in PS fixed in repairs complete all as specified and as directed.
Shower rose 125 mm size, brass chromium plated with or without swivel joints of standard size fixed in repairs to 15mm dia steel pipe or union complete all as specified and as directed.
125 mm size swivel shower of PTMT any colour suitable for fixing with 15mm dia pipe, minimum weight 40gms fixed in repairs complete all as specified and as directed.
15mm bore stop/angle cock, cast copper alloy, chromium plated fancy type, high pressure with capstan head handle, weight not less than 450 gms screwed both ends for iron pipe or for unions complete all as specified and as directed.
15mm dia stop cock / angle cock PTMT fancy type any colour screwed, for iron pipe and fixed in repairs complete all as specified and as directed.
Health faucet, brass body, chromium plated with 1mtr long SS braided tube & wall hook all as per Prayag Cat No-BEA-41/BEA-85 or techno commercially equivalent makes specified in PS fixed in repairs complete all as specified and as directed.
Jet spray, brass chromium plated suitable for EWC / Ango Indian EWC including fittings fixed in repairs complete all as specified and as directed.
Towel rail, stainless steel glossy finish all as per Prayag Cat No-BA10S or techno commercially equivalent makes specified in PS fixed in repairs complete all as specified and as directed.
Unbreakable square wall mounted shelf of 500mm size all as per Prayag Cat No. BEA-47A or techno commercially equivalent makes specified in PS fixed in repairs complete all as specified and as directed.
Corner shelf unbreakable (3Pcs set i.e 8"-1, 10"-1 & 12"-1) all as per Prayag Cat No. BEA-44A or techno commercially equivalent make specified in PS fixed in repairs complete all as specified and directed.
Toilet paper holder all as per Prayag Cat No. BA-88 or techno commercially equivalent make specified in PS fixed in repairs complete all as specified and directed.
PVC connections 15mm dia with PTMT nuts of length of 450 mm long fixed in repairs complete all as specfied and as directed.
PVC connections 15mm dia with PTMT nuts of length of 450 mm long fixed in repairs but CP connection for hot and cold water complete all as specfied and as directed.
PVC urinal waste pipe 32mm dia 800mm long, fixed in repairs complete all as specified and directed
75mm bore PVC (SWR) floor trap plain with grating including jointing with solvent cement fixed in repairs complete all as specified and as directed.
PVC (SWR) gully trap 125/110mm setting and jointing in solvent cement fixed in repairs complete all as specified and as directed.
Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete fixed in repairs complete all as specified and as directed.
110 mm bore PVC (SWR) pipes, type 'B' single socketed in any length with rubber ring joints laid in trenches or in floors with necessary fittings fixed in repairs complete all as specified and as directed.
75 mm bore PVC (SWR) pipes, type 'B' single socketed in any length with rubber ring joints laid in trenches or in floors with necessary fittings fixed in repairs complete all as specified and as directed.
110 mm bore PVC (SWR) pipes, type 'B' single socketed in any length with rubber ring joints fixed to wall including PVC clamps and necessary fittings fixed in repairs complete all as specified and as directed.
75 mm bore PVC (SWR) pipes, type 'B' single socketed in any length with rubber ring joints fixed to wall including PVC clamps and necessary fittings fixed in repairs complete all as specified and as directed.
110mm bore PVC (SWR) bends, type 'B' with access door complete all as specified and as directed.
75mm bore PVC (SWR) bends, type 'B' with access door complete all as specified and as directed.
110mm bore PVC (SWR) branch piece (single Y), type 'B' equal or unequal with access door complete all as specified and as directed.
75mm bore PVC (SWR) branch piece (single Y), type 'B' equal or unequal with access door complete all as specified and as directed.
PVC(SWR) `P' or S trap complete as in repairs complete all as specified and as directed.
PVC (SWR) vent cowl of bore 75 mm dia, including taking down old PVC vent cowl all as specified and as directed.
PVC (SWR) vent cowl of bore 110 mm dia, including taking down old PVC vent cowl all as specified and as directed.
Preparation of new or previously untreated wooden surfaces of any description not other wise described over 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Preparation of old painted wooden surfaces of any description exceeding 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed
Preparation of old painted steel surfaces of any description exceeding 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Preparation of new plastered surface of walls and applying two coats of distermper oil emulsion, white or tinted over a coat of alkali resistance primer etc complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer all as specified and as directed.
Preparation of newly plastered ceiling surfaces of any description and applying three coats of white wash complete all as specified and directed.
Preparing old plastered surface of walls and applying two coats of distemper oil emulsion, white or tinted over a coat of alkali reistance primer over 2 mm thick uniform layer of wall care putty including complete removal of existing treatment etc complete all as specified and as directed
Preparation of plastered or un plastered old decorated surfaces of walls by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts, treating oily and greasy spots, filling holes and cracks with suitable material like white cement or plaster of paris and applying one coat distemper oil emulsion of approved tint complete all as specified and as directed.
All as per Sl Item No 1.136 above but two coats of distemper oil emulsion complete all as specified and as directed
M&L preparation of plastered or un plastered old decorated surfaces of ceiling by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or Plaster of Paris and applying one coat of white wash complete all as specified and as directed
All as per item no 1.138 above but two coats of white wash etc complete all as specified and as directed
Preparation of plastered or un plastered old decorated surfaces of walls by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds, moss and efflorescent salts, treating oily and greasy spots, filling holes and cracks with suitable material like white cement or plaster of paris and applying one coat of white wash complete all as specified and as directed.
All as per Sl Item No. 1.141 above but two coats of white wash complete all as specified and as directed.
Disconnecting to existing PVC tanks, setting aside ( for lowering down if required ) for repairs, hoisting if required, reconnecting and refixing in position capacity upto 1000 ltr including cleaning of overhead tank, removing the sludge, washing down with detergent powder & writing the date of cleaning with paint complete all as specified and as directed.
Rolled Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
18mm thick, PVC sheet one side prelaminated of approved texture ("Celuca Ply of Rajshree make or equivalent as approved by GE) as in kitchen cabinet (with shelves and partitions) including necessary fittings & fixtures as per manufacturer's instructions complete all as specified and directed.
Stainless steel kitchen baskets of various types such as plaint basket height 4" ,Thali basket 8" height, Cup saucer 4" heigt and perforated cutlury basket 4" height fixed in repairs all as specified and directed.
Stainless steel channel for basket size 600mm long and 46mm wide fixed in repars complete all as specified and directed.
Stainless steel handle for basket of size 6" all as specified and as directed.
Stainless steel Auto closing concealed hinges 9.5 cranks for half overlay doors with opening angle 950 (14-32mm) with integrated overlay adjustment + 2.50mm & depth adjustment 4mm complete all as specified and as directed. MAKE FOR SL ITEM NO. 1.145 to 1.148:- Godrej / Hettich.
Plain fillets square, rectangular or triangular in section clean sawn, secured with nails or brads of second class hard wood fixed to cupboard shutter not exc. 3 sq.cm cross section area all as specified and as directed.
Easy dry wall mounted stand consisting of 19 mm dia power coated MS base frame with a structure (Mesh) of 6 Nos of 2020 Grade SS rods of dia 5 mm and length 750 mm for drying clothes, with each mesh has total length of 4500 mm (approx 15 feet) of SS Rod, fixed in repairs
PART II ( E/M WORKS)
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan,call bell socket or power circuits) including fittings such as switches, ceiling roses, regulators, sockets, light fittings, fans etc., complete and making good the disturbed surface of walls, ceiling etc., including painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
Point wiring complete concealed with 1.5 sq.mm single core PVC insulated unsheathed 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked including accessories concealed in walls including MS terminal boxes fabricated with 1.6 mm thick MS sheet, concealed on walls with laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for one light point controlled by one switch.
All as per Sl Item No. 2.002 here in before but for one fan point controlled by one switch/regulator.
All as per Sl Item No. 2.002 here in before but for one light point controlled by 2 way switch.
All as per Sl Item No. 2.002 here in before but for one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 2.002 here in before but for one bell/buzzer point controlled by bell push.
All as per Sl Item No. 2.002 here in before but for one 3 pin socket out let 5 Amps on same board.
Point wiring complete concealed for modular type switch & sockets with 1.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked with accessories concelaed type wiring includign GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for one light point controlled by one switch.
All as per Sl Item No. 2.008 here in before but for one fan point controlled by one switch/regulator
All as per Sl Item No. 2.008 here in before but for one light point controlled by 2 way switch.
All as per Sl Item No. 2.008 here in before but for one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 2.008 here in before but for one bell/buzzer point controlled by bell push.
All as per Sl Item No. 2.008 here in before but for one 3 pin socket out let 5 A on same board.
Point wiring complete surface type with 1.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through and including PVC Casing & Caping ISI marked with accessories surface type wiring including 1.6 mm thick MS sunken boxes concealed on walls including laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed one light point controlled by one switch.
All as per Sl Item No. 2.014 here in before but for one fan point controlled by one switch/regulator.
All as per Sl Item No. 2.014 here in before but for one light point controlled by 2 way switch.
All as per Sl Item No. 2.014 here in before but for one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 2.014 here in before but for one bell/buzzer point controlled by bell push.
All as per Sl Item No. 2.014 here in before but for one 3 pin socket out let 5 A on same board.
Point wiring concealed complete with 2.5 sq.mm single core PVC insulated unsheathed 1100 volts grade multi stranded FRLS copper conductor cable conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium density ISI marked with accessories concealed type run on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet, concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Point wiring (modular) complete concealed with 2.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concealed wiring incl GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 2.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Point wiring complete surface type with 2.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through and incl non-metalicPVC casing caping ISI marked with accessories concealed wiring incl GI/ MS branded sunken boxes of suitable moodule concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 2.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. NOTE FOR Sl ITEM NO. 2.002 to 2.022 :- (i) The earth wire for the points in the same circuit can be looped from point to point. (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring. (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring.
LED batten suitable for indoor applications 18/20 Watts,4 feet with polycarbonate housing and integrated LED channel with white arcylic cover complete with all accessories including taking out old fittings all as per Bajaj, Cat No.830192 18W CDL/ Havells Cat No: LHEXAPP7IN1W020 / C&S Cat no: LTTB4F20W LED EW BATTEN complete all as specified and as directed.
LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories including taking out old fittings all as per Bajaj, Cat No.830206 10W CDL/ Havells Cat No: LHEXACP5IN1W010 of Havells / C&S Cat No:LTTB2F 10WLEDW BATEN all as specified and as directed.
Bulk head fittings of 10 watt, IP -65 type luminaries complete with all accessories including taking out old fittings all as per Bajaj Cat No: BIPWP 10 W LED of BAJAJ or or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Modular switch 1 way, 6 Amps, one module complete all as specified and as directed.
Modular switch 1 way 16 Amps, one module complete all as specified and as directed.
Modular switch 2 way, 6 Amps, one module complete all as specified and as directed.
Modular bell push, 1 way, 6 Amps, one module complete all as specified and as directed.
Modular socket, 6 Amps, 2/3 pin combined, two module complete all as specified and as directed.
Modular socket, 6 Amps / 16 Amps, 2/3 pin combined, two module complete all as specified and as directed.
Modular fan regulator, five stepped, 120 Watt, 2 Module complete all as specified and as directed.
Switch piano flush button single pole two way 5 Amps with ISI marked complete all as specified and as directed.
Angle holder PVC/polycarbonate type all as specified and as directed.
Switch Piano, flush type, 5 Amps, 240 Volts single pole with ISI marked complete all as specified and as directed.
Switch socket combination 3 & 2 pin, 5 Amps, 240 Volts, flush type multipurpose controlled by one switch all as specified and as directed.
Switch socket combination 2 in 1, 3 pin and 2 pin, 5 and 15 Amps flush type, universal complete all as specified and as directed
Socket outlet 2 in 1, 3 & 2 pin 5 Amps all as specified and as directed
Bell push flush type, one way 5 Amps all as specified and as directed.
MCB single pole and neutral 240 Volts, 40 Amps including taking down the existing un serviceable MCB complete all as specified and as directed.
MCB single pole 240 Volts, 6 to 32 Amps including taking down the existing un serviceable MCB complete all as specified and as directed.
MCB TPN 415 volts 32 to 63 Amps including taking down the existing complete as specified and as directed.
MCB DB SPN 4 way 240 volts, double door, with 200 Amps rated busbar for housing MCBs including taking down the existing complete as specified and as directed.
MCB DB SPN 8 way 240 volts, double door, with 200 Amps rated busbar for housing MCBs including taking down the existing complete as specified and as directed.
MCB DB TPN 4 way with double door type 415 volts with 200 Amps rated busbar for housing MCBs including taking down the existing complete as specified and as directed.
Ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
Stepped type electronic fan regulator flush switch type including taking down the existing complete as specified and as directed.
Ding dong bell AC 230 volts single pole including taking down the existing complete as specified and as directed.
Sub main wiring power/circuit using FRLS PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable 2 single core of size 6 sq.mm, earth continuity conductor of size 6 sq.mm green in colour drawn through and including PVC conduit of suitable size, medium grade concealed in walls/roof/floors including taking down the existing all as directed. NOTE:- Two wires of 6 sq.mm and one wire of 6 sq.mm and one run of PVC conduit shall be measured as one unit.
Sub main wiring power/circuit using FRLS PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable 2 single core of size 4 sq.mm, earth continuity conductor of size 4 sq.mm green in colour drawn through and including PVC conduit of suitable size, medium grade concealed in walls/roof/floors complete including taking down the existing all as directed. NOTE:- Two wires of 4 sq.mm and one wire of 4 sq.mm and one run of PVC conduit shall be measured as one unit.
Earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge not less than 1.5 m below ground level connected to earth lead by GI wire 4 mm dia by means of bolts nuts, check nuts, washers made out of galvanised iron connected to main switch all as shown in elect plate No 3 of MES SSR Part -I includingn excavation and earth work in any type of soil,funnel, 20 mm dia light grade GI watering pipe with chamber of PCC 1:3:6 type C1 40mm thick of size 450mm x450mm (1:2:4) type B1 for cover slab reinforced with 8mm dia TMT bars 10cm c/c both ways and with 6mm MS hook etc complete all as specified including testing on completion all as specified and directed.
30 Watt LED building security light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection including taking out old fittings all asper Bajaj, Cat No.:- ENXT P 30L WH SY PC SD or techno commercially equivalent makes specified in PS complete all as specified and as directed. .
Brackets made out of GI tubing medium grade 25 mm bore, approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc., applying two coats of aluminum paint over a coat of red oxide primer before fixing including removing the old existing GI bracket from building complete all as specified and as directed.
Sheet metal enclosure single pole and neutral with a two pin earth plug and socket with one single pole MCB 32 Amps, 230 Volts AC complete all as specifeid and directed.
Sai Ram Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .