| Sl No | Description | Qty | Unit | NAVITECH ENGINEERS L2 | M/s Ashu Brothers L1 | B.Dayal L4 | Nutech Air Projects L5 | Saraswati Electricals & Contractors L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Carriage of 11KV XLPE 3x185sqmm Cable from Store center to various work site loading and unloading both side. distance 1 km to 50 km. | 15,090 | Mtr | 50 ₹7,54,500 | 23 ₹3,47,070 | 19 ₹2,86,710 | 25 ₹3,77,250 | 15 ₹2,26,350 Lowest |
| 2.00 | Carriage of ACSR Dog Conductor from Store center to various work site loading and unloading both side. distance 1 km to 50 km. | 11,637 | Mtr | 5 ₹58,185 | 3.5 ₹40,729.5 | 2 ₹23,274 Lowest | 5 ₹58,185 | 2 ₹23,274 Lowest |
| 3.00 | Carriage of PCC Pole 8.5 MTR LONG from Store center to various work site loading and unloading both side. distance 1 km to 50 km. | 68 | Nos | 480 ₹32,640 Lowest | 525 ₹35,700 | 600 ₹40,800 | 500 ₹34,000 | 1,200 ₹81,600 |
| 4.00 | Carriage of PCC Pole 11 MTR LONG from Store center to various work site loading and unloading both side. distance 1 km to 50 km. | 72 | Nos | 566 ₹40,752 Lowest | 825 ₹59,400 | 700 ₹50,400 | 800 ₹57,600 | 1,400 ₹1,00,800 |
| 5.00 | Carriage of 11 KV VCB O/G CTR 200/100/5A, 350 MVA from Store center to various work site loading and unloading both side. distance 1 km to 50 km. | 3 | Nos | 6,000 ₹18,000 | 2,990 ₹8,970 Lowest | 5,000 ₹15,000 | 4,000 ₹12,000 | 6,000 ₹18,000 |
| 6.00 | Carriage of line material as:-11KV XLPE 3x185sqmm Cable O/D- 110 Nos, 11KV XLPE 3x185sqmm Cable I/D- 2 Nos, 11KV XLPE 3x185sqmm Cable STH- 24 Nos, 11 kv Fuse Set D/O- 1 Nos, Stay Set Complete- 54 Nos, GI Wire 5mm 6 SWG- 1271 Kg, GI Wire 8 SWG- 200 Kg, 11 KV V Type Steel Cross Arm- 68 Nos, 11 KV Composite Disc Insulator- 89 Nos, 11 KV Polly Disc Insulator with fitting- 60 Nos, 11 KV Pin Insulator With Pin- 315 Nos, 11 KV Polly Pin Insulator- 12 Nos, 11 KV Polly Pin Insulator With Pin- 54 Nos, 11KV Polymeric Disc Insulator- 6 Nos ...etc...from Store center to various work site loading and unloading both side. distance 1 km to 50 km. | 1 | Job | 55,000 ₹55,000 | 30,000 ₹30,000 | 25,000 ₹25,000 | 25,000 ₹25,000 | 20,000 ₹20,000 Lowest |
| 7.00 | Dismanteling of Acsr scrap Conductor and safely carriage from site to store center/je store loading and unloading both side. | 100 | Kg | 11 ₹1,100 | 28 ₹2,800 | 5 ₹500 Lowest | 30 ₹3,000 | 20 ₹2,000 |
| 8.00 | Dismanteling of MS STP Off Size Pole and safely carriage from site to store center/je store loading and unloading both side. | 20 | Kg | 34 ₹680 | 28 ₹560 | 500 ₹10,000 | 30 ₹600 | 20 ₹400 Lowest |
| 9.00 | Providing and Complete Erection Chemical Earthing at site with all accessories complete in all respect as per respo Norms. (Chemical earthing Sample will be provided to SE-EUDC-I, GZB.) | 2 | Nos | 9,000 ₹18,000 | 7,000 ₹14,000 | 17,000 ₹34,000 | 6,000 ₹12,000 Lowest | 12,000 ₹24,000 |
| 10.00 | Erection of 11 Mtr Long PCC Pole at various site complete in all respect as per respo Norms. | 72 | Nos | 4,200 ₹3,02,400 | 2,800 ₹2,01,600 Lowest | 5,000 ₹3,60,000 | 3,000 ₹2,16,000 | 4,000 ₹2,88,000 |
Tender Value
₹1.8 Cr
EMD Value
₹1.8 L
Closing Date
17 Sept 2025, 11:00 amClosed
SH. ANIL KUMAR SINGH, SE, EUDC-1 GZB
a block hydel colony kavinagar ghaziabad
for Work of 11 KV Line Biffercation at various site Under Business Plan Scheme 2025-26 in the Area of EE, EUDD-I, EUDD-III, EUDD-V and EUDD-IX Ghaziabad. Under the jurisdiction of SE, EUDC-I, Ghaziabad.
2025_PVVNL_1070474_2
09/2025-26/EUDC-1/GZB
Open Tender
Electrical Works
Item Rate
90 days
GHAZIABAD
please prefer tender documents
2 documents required · 2 mandatory
₹5,900
SUPERINTENDING ENGINEER, EUDC-1 GHAZIABAD
₹1.8 L
3 Oct 2025
12 Sept 2025
17 Sept 2025
12 Sept 2025
17 Sept 2025
12 Sept 2025
Amount
Carriage of 11KV XLPE 3x185sqmm Cable from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of ACSR Dog Conductor from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of PCC Pole 8.5 MTR LONG from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of PCC Pole 11 MTR LONG from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11 KV VCB O/G CTR 200/100/5A, 350 MVA from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of line material as:-11KV XLPE 3x185sqmm Cable O/D- 110 Nos, 11KV XLPE 3x185sqmm Cable I/D- 2 Nos, 11KV XLPE 3x185sqmm Cable STH- 24 Nos, 11 kv Fuse Set D/O- 1 Nos, Stay Set Complete- 54 Nos, GI Wire 5mm 6 SWG- 1271 Kg, GI Wire 8 SWG- 200 Kg, 11 KV V Type Steel Cross Arm- 68 Nos, 11 KV Composite Disc Insulator- 89 Nos, 11 KV Polly Disc Insulator with fitting- 60 Nos, 11 KV Pin Insulator With Pin- 315 Nos, 11 KV Polly Pin Insulator- 12 Nos, 11 KV Polly Pin Insulator With Pin- 54 Nos, 11KV Polymeric Disc Insulator- 6 Nos ...etc...from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Dismanteling of Acsr scrap Conductor and safely carriage from site to store center/je store loading and unloading both side.
Dismanteling of MS STP Off Size Pole and safely carriage from site to store center/je store loading and unloading both side.
Providing and Complete Erection Chemical Earthing at site with all accessories complete in all respect as per respo Norms. (Chemical earthing Sample will be provided to SE-EUDC-I, GZB.)
Erection of 11 Mtr Long PCC Pole at various site complete in all respect as per respo Norms.
Erection of PCC Pole 8.5 Mtr Long at various site complete in all respect as per respo Norms.
Providing and Concreting of Pole at various site complete in all respect as per respo Norms.
Providing and Earthing of Pole at various site complete in all respect as per respo Norms.
Supply & Fixing HDPE Pipe 140 mm OD PN-4 in 6MTR at various site with all accessories complete in all respect as per respo Norms.
Laying of 11KV XLPE 3x185sqmm Cable by trunchless method (with road restoration kuchha pucca and with permission concerend authority- 275 Mtr) through above HDPE Pipe at various site as per Estimate with proper connection complete in all respect as per respo Norms.
Laying of 11KV XLPE 3x185sqmm Cable in air/ loop & riser/site requirement …etc with proper connection complete in all respect as per respo Norms.
Laying, Lifting, sagging ACSR Dog Conductor at various site complete in all respect as per respo Norms.
Fixing and Installation of 11 KV VCB O/G CTR 200/100/5A, 350 MVA at various site complete in all respect as per respo Norms.
Fixing and filling of 11KV XLPE 3x185sqmm Cable O/D at various site complete in all respect as per respo Norms.
Fixing and filling of 11KV XLPE 3x185sqmm Cable I/D at various site complete in all respect as per respo Norms.
Fixing and filling of 11KV XLPE 3x185sqmm Cable STH at various site complete in all respect as per respo Norms.
Fixing and Installation of 11 kv Fuse Set D/O at various site complete in all respect as per respo Norms.
Fixing and Installation of Stay Set Complete at various site complete in all respect as per respo Norms.
Fixing and Installation of GI Wire 5mm 6 SWG at various site complete in all respect as per respo Norms.
Fixing and Installation of GI Wire 8 SWG at various site complete in all respect as per respo Norms.
Fixing and Installation of 11 KV V Type Steel Cross Arm at various site complete in all respect as per respo Norms.
Fixing and Installation of 11 KV Composite Disc Insulator at various site complete in all respect as per respo Norms.
Fixing and Installation of 11 KV Polly Disc Insulator with fitting at various site complete in all respect as per respo Norms.
Fixing and Installation of 11 KV Pin Insulator With Pin at various site complete in all respect as per respo Norms.
Fixing and Installation of 11 KV Polly Pin Insulator at various site complete in all respect as per respo Norms.
Fixing and Installation of 11 KV Polly Pin Insulator With Pin at various site complete in all respect as per respo Norms.
Fixing and Installation of 11KV Polymeric Disc Insulator at various site complete in all respect as per respo Norms.
Supply & Fixing of M.S Channel 100x50x6 mm at various site complete in all respect as per respo Norms.
Supply & Fixing of M.S Angle 65x65x6 at various site complete in all respect as per respo Norms.
Supply & Fixing of Bracing Set(4.3m X 4.3m) angle Iron 65x65x6 with clamp at various site complete in all respect as per respo Norms.
Supply & Fixing of E Bracket For 11 Kv at various site complete in all respect as per respo Norms.
Supply & Fixing of Danger Board at various site complete in all respect as per respo Norms.
Supply & Fixing of Number Plate With Clamp And Nut & Bolt at various site complete in all respect as per respo Norms.
Supply & Fixing of Nut & Bolt with Washer off size at various site complete in all respect as per respo Norms.
Supply & Fixing of Stone Pad 300x300x75 at various site complete in all respect as per respo Norms.
Supply & Fixing of PCC Holding Clamp at various site complete in all respect as per respo Norms.
Supply & Fixing of Clamp & Nut Bolt For 11 KV V type Cross Arm at various site complete in all respect as per respo Norms.
Supply & Painting of Alluminium Paint at various site complete in all respect as per respo Norms.
Supply & Fixing of Alluminium Winding wire at various site complete in all respect as per respo Norms.
Supply & Painting of Red Oxide Paint at various site complete in all respect as per respo Norms.
Supply & Fixing of Earthing Rod at various site complete in all respect as per respo Norms.
Supply & Fixing of Cable Root Marker at various site complete in all respect as per respo Norms.
Supply & Fixing of Lug for ACSR Dog at various site complete in all respect as per respo Norms.
Supply & Fixing of P.G. Clamp Dog to Dog at various site complete in all respect as per respo Norms.
Supply & Fixing of Alluminium Jointing Sleaves at various site complete in all respect as per respo Norms.
work of Tree Cutting under EUDD-9 complete in all respect as per respo Norms.
Supply & Fixing of 11 KV 3x185 XLPE Cable Holding at various site complete in all respect as per respo Norms.
Supply & Fixing of GI Wire 6SWG at various site complete in all respect as per respo Norms.
Supply & Fixing of GI Barbed Wire at various site complete in all respect as per respo Norms.
Supply & Fixing of GI Pipe 6" Dia 1.5 mm at various site complete in all respect as per respo Norms.
All other Remainings works Shall have to complete in all respect as per site requirement.
NAVITECH ENGINEERS (BID ID -5540533)
Saraswati Electricals & Contractors (BID ID -5540641)
B.Dayal (BID ID -5540638)
Nutech Air Projects (BID ID -5540100)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.54 MB
TD09F.pdf
Tender Documents • 0.93 MB
BOQ_1959324.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .