Tender Value
₹13.5 L
EMD Value
₹27,000
Closing Date
5 Apr 2021, 6:00 pmClosed
GE (AF) BHISIANA
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (AF), BHISIANA, BATHINDA-151201
Repair Maint of Elect Supply and External Water Supply Distribution System alongwith connected Works at Ferozepur under GE (AF) Bhisiana
2021_MES_429582_1
GE/BHI-58/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) BHISIANA
Please Refer Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) BHISIANA
₹27,000
Yes
16 Jun 2021
10 Mar 2021
7 Apr 2021
10 Mar 2021
5 Apr 2021
24 Mar 2021
Amount
Excavation in trenches n.exc. 1.5 mtr wide and n.exc 1.5m depth for foundation of poles/laying of cables/stay/strut etc n.exc 10 Sqm on plan and getting out in soft/loose soil.
Returning, filling including spreading, leveling watering and well ramming in layers not exceeding 25 cm as directed.
Removing excavated material (soil) n.exc 50m and depositing where directed at a level not exc 1.5 mtr above the starting point.
M&L for providing Fazilka river sand as in sand cushioning to under ground cable including punning down of sand in layers as specified and as directed.
M&L for brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick n.exc 10mm complete all as specified and directed.
M&L for making bore below the road for crossing the GI pipe light grade 50 mm dia for cable protection and fill the putty on both sides of the GI pipe after crossing the armoured cable to avoid the water inside complete all as specified and directed by Engr-in-Charge.
M&L for galvanized steel tubing 40 mm light garde (ISI marked) for protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
All as per item No. 7 above but having size 50 mm.
M&L for taking down unserviceable LT UG cable any type from trenches and removing the fault and relaying of LT UG cable after rectifing the fault and making cable in serviceable condition of 1100 V grade UG cable of size from 10 to 300 sqmm, 3½ core. Note : (i) Striaght throuigh joints measure and paid seaprately. (ii) Excavation, Returning, filling, removal, sand cushioning & brick protection will be measured and paid separately.
M&L for cable jointing kit for 1100 volts grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 10 to 50 sqmm, complete all as directed at site.
All As per Item No. 10 above but for cable of size 70 to 120 sqmm.
All As per Item No. 10 above but for cable of size185 to 300 sqmm.
Taking out U/S LT Cable from trench/on wall of 50 to 70 sqmm complete all as specified and directed by Engr in Charge.
Taking out U/S LT Cable from trench/on wall of 25 to 35 sqmm complete all as specified and directed by Engr in Charge.
Taking out U/S LT Cable from trench/on wall of 10 to 16 sqmm complete all as specified and directed by Engr in Charge.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade, heavy duty with aluminium conductor 70 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade, heavy duty with aluminium conductor 50 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade, heavy duty with aluminium conductor 35 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade, heavy duty with aluminium conductor 25 Sqmm 4 core laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade, heavy duty with aluminium conductor 16 Sqmm 4 core laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade, heavy duty with aluminium conductor 10 Sqmm 2 core laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified.
Dismantling/disconnection of LT connections from ACB by taking down proper shutdown, opening the ACB (Panel) installed at various locations for servicing, overhauling all moving contacts, fixed contacts, tripping coil including testing the insulation value of moving and fixed contacts and cleaning the carbon from contact point with petrol etc and greasing oiling the all moving parts including testing all meters/relay such as under voltage relay and servicing, shut trip coil etc including reassembling the ACB and testing after completion of work all as directed by Engr-in-Charge. Note : Complete servicing and maintenance will be carried out at site only.
Material and labour for preparation of old steel surfaces including welding work of doors of panels/feeder piller/Jn box, hinges with locking arrangement and applying one coat of synthetic enamel ivory paint/ (Smoke grey) to steel LT Panel/bus bar box and junction boxes surface after disconnecting the electrical connections and reconnecting LT cables after painting, complete as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 160 Amps, 4 Pole 16 Ka with thermal magnetic settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 200 Amps, 4 Pole 25/26 Ka with thermal magnetic settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 250 Amps,4 Pole 25/26 Ka with thermal magnetisettings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6.3mm thick burried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron strip of 32 x 6 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 mtr all as specified and shown in electrical plate No. 3 of SSR-2009 (Part-I) complete all as specified and directed.
Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC Tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire , one twin core cable flat or circular of size 10 Sqmm complete all as specified and directed.
Taking out U/S HT Cable from trench of any size complete all as specified and directed by Engr in Charge.
Supplying, laying, jointing and testing underground cable XLPE insulated screened armoured and PVC bedded HT 11000 volts grade (heavy duty) with aluminium conductor 3 core, 95 Sqmm, laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified.
Dismantling of HT cable Jointing Kit of any type and any size complete all as specified and directed by Engr in Charge.
M&L for Cable Jointing Kit for 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type end joint complete with jointing material and acessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and directed by Engr in Charge.
M&L for Cable Jointing Kit for 11 KV (Earthed) grade cable for indoor termination heat shrinkable type end joint complete with jointing material and acessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and directed by Engr in Charge.
M&L for Cable Jointing Kit for 11 KV (Earthed) grade cable for indoor termination heat shrinkable type straight throught joint complete with jointing material and acessories suitable foe 3 Core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and directed by Engr in Charge.
M&L for calibration/overhauling/servicing of relay any type voltage, current (e.g. Earth fault relay/Over current relay, etc) for 11 KVA HT panel. The setting of these relays should be as per the PSPCL norms so that individual breaker/feeder should be tripped and fault is not travelled back to MRS and subsequently to PSPCL power house. The calibration of relay is to be done by a reputed firm and it is to be submitted to to the AGE E/M. All the calibration should be done in the presence of Engineer-in-Charge. Note : Replacement cost of HRC fuses are included in quated rates.
M&L for disconnecting the existing servicing electric supply from HT 11KV system of any make type taking out switch gear from SF-6 circuit breaker (any type)/VCB/OCB, cleaning from inside and outside by using CRC-26 spray or any other cleaning agents which can improve the electrical conductivity or properties, greasing whereever required overhuling of switch gear, checking the fixed/moving contacts of all the 3 phases adjusting electrical/electronic/mechanical components all as per Mfg instruction manual and standard practice & reassembling the same after necessary servicing repair including testing and commissioning in its original position & necessary connection etc all as specified and directed. This work is to be get done from company authorised sales and supplier dealers and all as specified and directed.
Dismantling the existing defective Automatic voltage stabilizer oil/Air cooled type 3 Phase 415 Volts AC supply any cap/type including disconnection of electric connection and opening the stabilizer, removing the burnt parts and replacement of defective parts by providing new components/parts as per existing make and capacity. Prepare the old surface by using blow lamp/soft wire brush and spray painting with one coat primer and two coat of synthetic enamel paint, reassembling the same after necessary servicing repair including testing and commissioning in its original position & necessary connection etc all as specified and directed. Note : (i) The spare parts shall be measured and paid separately in appropriate item in schedule. (ii) Labour charges for repair/replacement of minor parts like item costing upto Rs 500/- are included in the above item.
M&L for online de-hyderation and filtration at site from the transformer of various capactiy, (till the di-electric strength reaches 40 KV to 60KV withstand for one minute is achieved) complete all as directed by Engineer-in-Charge. Note : Contractor will arrange filtration plant machine at site of transformer. Dehydration work will be carried out in working condition and electric supply will be taken from same transformer.
Supply & pouring of transformer oil with Di-electric strength not less than 50 KV di-electric strength in the sealed drum or filled in transformer/on site/workshop complete all as specified and directed by Engr-in-Charge.
M&L for Scrapping/cleaning of outer surfaces of transformer and spray painting (smoke grey colour) with two coats of best quality synthetic enamel paint over one coat of red oxide primer complete including writing of MES No (white colour paint) all as directed by Engineer-in-Charge upto 500 KVA capacity transformer of any make/shape/size.
Prepration of old steel surfaces and applying two coat of synthetic enamel white paint to steel tubular /PCC Pole and upto 1 mtr height from ground level alternative in yellow and black strips of 30 CM height each including numbering of Pole No with black paint complete all as specified and directed by Engr in Charge.
M&L for painting of old painted surfaces of cross arms , clamps etc worth on top of the LT / HT poles of 9/11 mtr height with one coat of aluminium paint after preparing the surface.
Trimming/cutting of trees branches, bushes obstructing the HT/LT lines making clear distance of 3 RM from the outer conductors of OH Lines all around and all substations fencing around pump house area, below surrounding of OHTs including removing of branches/ bushes of trees from site all as directed.
Material and labour for disconnection and dismantling of existing transformer of capacity from 63 to 500 KVA for repair work and refixing and reconnecting the same complete all as directed as under:- (i) Replacement of gasket, nuts bolts and washer. (ii) Replacement of neoprene rubber washer. (iii) Replacement of silica gel. (iv) Replacement of copper lugs including ACSR jumpers from HT OH line to primary side of TF. (v) Cleaning of bush insulator LT/HT side. (vi) Tightening of connection of earthing lead to neutral & body. (vii) Replacement of MS cable box cover as per requirement at site. (viii) Replacement of HT & LT bush. (ix) Replacement of HT & LT bush copper Rod. (x) Replacement of oil level indicator if required.
Dismantling/Taking down of street light/flood light of any capacity and any size complete all as directed.
Supply and fix 60 W LED based street light luminaries new generation energy saving & environment friendly light fitting high power LEDs as light sources. LED luminous efficiency should be > 60Lm/w. It should have active power factor correctio (APFC) electronic gear (electronic driver). Luminaire housing shall be of pressure die-cast aluminium alloy LM24 for gear and extruded aluminium lamp housing (Heat shrink for better heat transmission. It shall have epoxy powder coated grey finish phosphochromate treatment,IP-66 protection Class-I operating voltage range should be from 120 volt to 270 volt AC and frequency range 50Hz. fitting should be suitable for an ambient temparature from -40°C to 50 °C and humidity level 10% to 90% including connection with PVC unsheathed wire aluminium conductor 3 x 1.5 sqmm with OH line or PVC junction box complete all as specified and directed by Engr-in-Charge.
S & F 200 watt LED Flood light luminaire of epoxy powder coated CRCA MS housing with epoxy powder coated aluminium heat sink with system wattage with 120 degree view angle>200 lumen/watt, luman maintenance>70% at 50,000 Hrs, color temperature of >5000-6500K, color rendering and LM80 test compliance. The driver must be integral APFC and constant current type having THD<15% and power factor>0.95 with short circuit protection, open protection, reverse polarity protection, high voltage protection complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as directed at site.
Supplying and fixing 1100 Volts grade heavy duty cable one twin core cable flat or circular of size 10 Sqmm PVC insulated aluminium conductor, served with inner sheathing of PVC Tape and overall PVC sheathed in service connections all as specified and directed.
Taking out unserviceable broken aviation, obstruction light from tower, water reservoir for necessary replacement/repair.
Supply and fixing LED Aviation obstruction light, with light depended sensor, IP 65 Protected of capacity 6W with suitable lamp complete all as specified and directed.
M&L for removing normal earthing and M&L for commissioning, installation and testing of maintenance free UL approved copper bonded earth rod of 10 feet length, 17.2 mm dia made of high tensile low carbon steel rod, molecularly bonded with 99.9% electrolytic grade copper on outer surface (minimum copper bonding thickness - 250 microns) with exothermally jointed copper bus bar of 50 x 6 x 200 mm for connection. The rod and exothermic joint together successfully tested at 25 KA fault current by CPRI with 50 Kg eco friendly earth enhancing compound with each earth rod. The earth pit should be 125 mm dia the compound should comply to IEC:62561-7 having passed leaching, corrossion, sulphur and resistivity test as per IEC: 62651-7 by NABL accredit Lab with FRP earth pit cover of top size lockable Lid complete all as specified and directed by Engr-in-Charge. (a) The test result of each set of earthing is less than 1 Ohm. All earthing test will be carried out in presence of MES Rep, manufacturer Rep and test result will be recorded in a register with sign of manufacturer & Engr-in-Charge. (b) 5 Year gaurantee certificate from company for maintaining earth result less than 1 Ohm will be submitted by Contractor. (c) 1425 RTC SS Universal clamp of size 175 x 50 x 3mm. (d) Earth enhancing compound (PROCEM) ECS GB 25 tested as per IEC 62561-7-25Kg. (e) Chemical earthing will be installed by manufacturer Rep and purchase voucher of earthing will be produced before payment. Payment shall be made only after getting satisfactory result.
M&L for removing normal earthing and M&L for commissioning, installation and testing of maintenance free UL approved copper bonded earth rod of 10 feet length, 17.2 mm dia made of high tensile low carbon steel rod, molecularly bonded with 99.9% electrolytic grade copper on outer surface (minimum copper bonding thickness - 250 microns) with exothermally jointed copper bus bar of 50 x 6 x 200 mm for connection. The rod and exothermic joint together successfully tested at 25 KA fault current by CPRI with 50 Kg eco friendly earth enhancing compound with each earth rod. The earth pit should be 125 mm dia the compound should comply to IEC:62561-7 having passed leaching, corrossion, sulphur and resistivity test as per IEC: 62651-7 by NABL accredit Lab with FRP earth pit cover of top size lockable Lid complete all as specified and directed by Engineer-in-Charge. (a) The test result of each set of earthing is less than 1 Ohm. All earthing test will be carried out in presence of MES Rep, manufacturer Rep and test result will be recorded in a register with sign of manufacturer & Engr-in-Charge. (b) Chemical earthing will be installed by manufacturer Rep and purchase voucher of earthing will be produced before payment. Payment shall be made only after getting satisfactory result.
S&F test point terninal block made of of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed inlcuding 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and directed.
S&F of copper strip of size 20 x 3.15 mm on PVC/porcelain insulator at suitable distance with saddeles and fixing screw etc for roof/Wall conductors and down conductors above ground all joints of copper strip should be brazed properly complete all as specified and directed.
M&L for copper brazing for copper strips of various sizes laying on wall /roof etc with the help welding machine and skilled tradesmen by using welding rod etc by taking safety precaustions during brazing as directed by the AGE EM /users complete all as specified and as directed by Engr in Charge.
M&L for fixing the procelin cleat with the help of nut, bolts clamps etc to fix the strips of various size and types to separate from groung and wall as directed at site by Engr in Charge complete all as specified.
M&L for PVC conduit heavy duty of 40 mm dia size for the protection of the earthing strip on wall/roof with the help nuts, bolts clamps, PCC work etc as directed at site by Engr in Charge.
Taking out /down old unserviceable CI pipe of 150 mm dia including all fittings etc from trenches complete all as specified and directed. Note : Earth work shall be measured and paid seperately.
Taking out /down old unserviceable CI pipe of 100 mm dia including all fittings etc from trenches complete all as specified and directed. Note : Earth work shall be measured and paid seperately.
Taking out /down old unserviceable CI pipe of 80 mm dia including all fittings etc from trenches complete all as specified and directed. Note : Earth work shall be measured and paid seperately.
Taking out /down old unserviceable GI pipe of 40/50 mm dia including all fittings etc from trenches complete all as specified and directed. Note : Earth work shall be measured and paid seperately.
Taking out /down old unserviceable GI pipe of 25 mm dia including all fittings etc from trenches complete all as specified and directed. Note : Earth work shall be measured and paid seperately.
Taking out /down old unserviceable GI pipe of 20 mm dia including all fittings etc from trenches complete all as specified and directed. Note : Earth work shall be measured and paid seperately.
Supply, laying, jointing of CI Pipe spigot and socketed end pipes centrifugally class LA in any length of size 150 mm dia in trenches complete all as directed.
Supply, laying, jointing of CI Pipe spigot and socketed end pipes centrifugally class LA in any length of size 100 mm dia in trenches complete all as directed.
Supply, laying, jointing of CI Pipe spigot and socketed end pipes centrifugally class LA in any length of size 80 mm dia in trenches complete all as directed.
Supply and laying galvanised iron pipe, medium grade 50 mm bore with all new fittings, laid in trenches including jointing material etc complete all as specified and directed.
Supply and laying galvanised iron pipe, medium grade 40 mm bore with all new fittings, laid in trenches including jointing material etc complete all as specified and directed.
Supply and laying galvanised iron pipe, medium grade 25 mm bore with all new fittings, laid in trenches including jointing material etc complete all as specified and directed.
Supply and laying galvanised iron pipe, medium grade 20 mm bore with all new fittings, laid in trenches including jointing material etc complete all as specified and directed.
M&L for run lead joints for 150mm dia spigot and socketed CI pipe fittings including spun yarn etc.
M&L for run lead joints for 100mm dia spigot and socketed CI pipe fittings including spun yarn etc.
M&L for run lead joints for 80mm dia spigot and socketed CI pipe fittings including spun yarn etc.
Supply & fixing 150 mm dia sluice valve PN 1:6 ISI marked confirming to IS-14846, flanged and drilled, gun metal spindle and iron wheel including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as directed by Engineer-in-Charge.
Supply & fixing 80 mm dia sluice valve PN 1:6 ISI marked confirming to IS-14846, flanged and drilled, gun metal spindle and iron wheel including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as directed by Engineer-in-Charge.
Supply & fixing 100 mm dia sluice valve PN 1:6 ISI marked confirming to IS-14846, flanged and drilled, gun metal spindle and iron wheel including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as directed by Engineer-in-Charge.
S & F Gun metal globe or gate valve (ISI marked), with iron wheel head, screwed both ends, suitable for 50 mm bore iron pipe and fixed including testing complete all as specifed and directed by Engr-in-Charge.
S & F Gun metal globe or gate valve (ISI marked), with iron wheel head, screwed both ends, suitable for 40mm bore iron pipe and fixed including testing complete all as specifed and directed by Engr-in-Charge.
S & F Gun metal globe or gate valve (ISI marked), with iron wheel head, screwed both ends, suitable for 25 mm bore iron pipe and fixed including testing complete all as specifed and directed by Engr-in-Charge.
S & F Gun metal globe or gate valve (ISI marked), with iron wheel head, screwed both ends, suitable for 20 mm bore iron pipe and fixed including testing complete all as specifed and directed by Engr-in-Charge.
M&L for brick masonary valve pit (type B) of size 90 x 90 x 90 cm internal of chember) depth of chember to be reckoned from the top of PCC in foundation to top the MS cover as 1.5 mtr and including MS sheet cover fabricated from 3 mm thick MS sheet and frame of angle iron 40 mm x 40 mm 6 mm with fixing arrangement, hinges and locking arrangement and painting two coat of synethetic enamel paint over a coat of red oxide primer on MS cover and frame, inlcuding necessary excavation and earth work in any type of soil, returning, filling in approved soil disposal of surplus soil to a distance not exc 50 mtr, 150 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, brick work in cement motor (1:6) 15 mm thick plastering in cement mortoar (1:4) (both internally and externally) 100 mm thick PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in flooring complete all as directed.
M&L for brick masonary valve pit (type B) of size 60 x 60 x 60 cm (internal of chember ) depth of chember to be reckoned from the top of PCC in foundation to top the MS cover as 1.5 mtr and including MS sheet cover fabricated from 3 mm thick MS sheet and frame of angle iron 40 mm x 40 mm 6 mm with fixing arrangement, hinges and locking arrangement and painting two coat of synethetic enamel paint over a coat of red oxide primer on MS cover and frame, inlcuding necessary excavation and earth work in any type of soil, returning, filling in approved soil disposal of surplus soil to a distance not exc 50 mtr, 150 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, brick work in cement motor (1:6) 15 mm thick plastering in cement mortoar (1:4) (both internally and externally) 100 mm thick PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in flooring complete all as directed.
M & L for CI fittings for Spigot & Socketed pipe as bends, tapers, tee pieces any type angle/radius and straight connection pieces etc upto 150 mm dia pipe as in repair etc complete all as specified and directed.
Cleaning of RCC over head tank reservoir up to 1 lakh gallon capacity by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor and cleaning the inside and bottom surfaces of walls with help of wire brush and using specified dosage of Potassium permanganate and cleaned water than drain out completely material to the entire satisfaction of Engr in Charge with and including writting letters 5 CM height capacity of Tank and date of Cleaning of tank, with synthectic enamel paint on the other surface of the tank complete all as specified and directed.
Cleaning of Undergroung water tank up to 1 lakh gallon capacity by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor and cleaning the inside and bottom surfaces of walls with help of wire brush and using specified dosage of Potassium permanganate and cleaned water than drain out completely material to the entire satisfaction of Engr in Charge with and including writting letters 5 CM height capacity of Tank and date of Cleaning of tank , with synthectic enamel paint on the other surface of the tank complete all as specified and directed.
Cleaning of over head sintex tank of 10000 gallon capacity by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor and cleaning the inside and bottom surfaces of walls with help of wire brush and using specified dosage of Potassium permanganate and cleaned water than drain out completely material to the entire satisfaction of Engr in Charge with and including writting letters 5 CM height capacity of Tank and date of Cleaning of tank, with synthectic enamel paint on the other surface of the tank complete all as specified and directed.
M&L for rewinding of submersible pump capacity 20 HP three phase with super enameled copper wire of existing gauge including replacement of bush and nut and bolts, washer with condenser of existing Capacity etc complete all as specified and as directed by Engineer-in-Charge.
Physio-chemical bacteriological testing of water from the institute / lab as approved by the GE complete all as per IS : 10500 - 1991 including collection of water sample and submitting the same with institute / lab all as specified and directed by Engr-in-Charge. Note : The water testing parameters will be given by the department.
Radioactive test of drinking water (Borewell water) as per IS-10500:2012 (Parameters : Gross Alpha & Gross Beta test) at department of Atomic Energy, Board of Radiation & Isotope Technology, BARC/BRIT, Navi Mumbai all as specified and directed by Engr-in-Charge.
Arsenic test for drinking water from the institute / lab as approved by the GE complete all as per IS : 10500 - 1991 including collection of water sample and submitting the same with institute / lab all as specified and directed by Engr-in-Charge.
Repairs to Valve Masonry Pit (by means of internal plastering, replacement of angle iron, MS Sheet etc) of following size :-
M&L for stopping leakege of GI Pipe upto 100mm dia by replacing any type of (bend, tee, elbow, reducer, end plug, taper, union, nipple, socket etc) all as specified and directed by Engr-in-Charge (Excavation deemed to be included in quoted rate):-
50mm dia GI Pipe.
40mm dia GI Pipe.
25mm dia GI Pipe.
Dismantling/taking down the centrifugal pump set of capacity 10 HP from foundation after disconnecting of discharge, suction and induction motor connection and shifting to the same to civil work shop at Bathinda for the following repair:- (a) Dismantling the complete pump and taken out main shaft and impeller from the pump by disconnection of all nuts, bolts and washers and minor repair and balancing of main shaft and impeller by necessary lathe and machine work and replacement with complete new gasket and mild steel nut, bolt and washer complete all as directed. (b) Replacement of ball bearing NBC 6312 including providing of required grease complte 02 Nos. (c) Re-assembling the complete and fixing at site and connection of suction, discharge and the induction motor and testing the same on full load complete all as specified.
All as per item No. 93 above but having 5 HP pump.
M& L for Cleaning by antiscalent chemical and servicing of RO Plant of capacity 1000 Ltr/He with carrying out following repair:- (a) Repair to activated carbon filter with replacement of activted carbon of approx 80 Kg. (b) Repair to dual media filter with replacement of sand media of 100 Kg. (c) Repair/replacement of micron filter Qty-2. (d) Chemical washing of all RO membrane if required than replacment of Membrane Qty-04.
S&F DOL stater suitable for 5HP to 7.5HP electric motors including necessary electric connections complete all as directed.
S&F Star-Delta stater suitable for 10HP electric motors including necessary electric connections complete all as directed.
S&F Star-Delta stater suitable for 20HP electric motors including necessary electric connections complete all as directed.
Taking out U/S submersible motor from borewell of depth 500 ft with arrangement of manpower & chain pully & after repair refix the motor in same depth with the help of manpower & chain pully. Note: Any damage to motor, pipe and cable will be repaired by Contractor.
Chanana Engineers & Contractors
Aman Enterprises
Rasvinderpalandco
M/S Yashpaul Gulati
M/s Luxmi Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .