Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-AOC H NO 831 1 HINDU NAGAR TILAKWADI BELGAUM 590006 | BELGAUM | BELGAUM | KARNATAKA | 590006 | L1 | Accepted-AOC Lowest quoted amount overall reasonable | |
| 2 | L2₹10.3 L+₹6,680 (0.66%)Rejected-AOC | L2 | Rejected-AOC 2nd lowest hence rejected | |
| 3 | L3₹13.3 L+₹3.1 L (30.1%)Rejected-AOC THEERTHAM NADUVILEMURI PADANILAM POST NOORANAD ALAPPUZHA DIST KERALA 690529 | ALAPPUZHA | KERALA | 690529 | L3 | Rejected-AOC 3rd lowest hence rejected |
| Sl No | Description | Qty | Unit | DHAIRYASIL RAMAKANT DESAI L1 | M/s. VIJAY ELECTRICALS L2 | Green Ray Enterprises L3 |
|---|---|---|---|---|---|---|
| 1.00 | Repair / Maintenance of window/ split type air conditioner, water cooler etc., any capacity any size, testing all the components / parts, identifying the defective parts & reporting to Engineer-in-Charge, cleaning the filter, cooling system, checking of wiring, condenser / evaporator cleaning the unit with blower motor, with and including replacement of minor parts such as wires, bolts, nuts, pads, checking air flow, temperature, working condition for smooth functioning, sealing the pipe hole, checking drain pipe etc., and maintaining properly the record, complete all as specified and as directed by Engineer-in-Charge. Note: Quoted rate shall be inclusive for rectifying all the defects and make the unit functional and in working condition. | 250 | EACH JOB | 100 ₹25,000 Lowest | 150 ₹37,500 | 250 ₹62,500 |
| 2.00 | Servicing of Split type Air conditioner of 1.5 TR/2.0TR capacity by disconnecting all the electrical connections, servicing and cleaning the indoor unit & outdoor unit using power jet spray only (external) with suitable foam type cleaning agent duly securing the indoor unit with waste water collecting bag to avoid the spread of water in the working area and out door unit, complete all as specified and as directed by Engineer-in-Charge. | 116 | EACH JOB | 400 ₹46,400 | 150 ₹17,400 Lowest | 500 ₹58,000 |
| 3.00 | S&F PVC flexible drain pipe, corrugated type including bends, saddles etc., for split type ACs as per existing size, fixed on wall, with and including taking down existing u/s drain pipe of any length, complete all as specified. | 200 | Running Metre | 10 ₹2,000 Lowest | 300 ₹60,000 | 10 ₹2,000 Lowest |
| 4.00 | S&F Factory made sealed reciprocating Compressor of Copper Condenser type, pre-charged with suitable refrigerant gas as per manufacturers instructions, suitable for window / split type AC 1.5 TR capacity of any model /make, with mounting assembly such as rubber, springs, etc., fixing after disconnecting all electrical connections, bragging the suction / discharge line, pressure leak proof testing, with and including taking down existing u/s compressor of any type, complete all as specified and as directed by Engineer-in-Charge. | 15 | EACH | 5,000 ₹75,000 Lowest | 7,000 ₹1,05,000 | 9,000 ₹1,35,000 |
| 5.00 | S&F Factory made sealed reciprocating Compressor of Copper Condenser type, pre-charged with suitable refrigerant gas as per manufacturers instructions, suitable for window / split type AC 2.0TR capacity of any model /make, with mounting assembly such as rubber, springs, etc., fixing after disconnecting all electrical connections, bragging the suction / discharge line, pressure leak proof testing, with and including taking down existing u/s compressor of any type, complete all as specified and as directed by Engineer-in-Charge. | 6 | EACH | 7,000 ₹42,000 Lowest | 8,000 ₹48,000 | 10,000 ₹60,000 |
| 6.00 | S&F Solid drawn copper pipe of 1/4" inch outer dia, with and including necessary brazing, soldering, flaring, fittings, pipe supports, with all accessories as per manufacturers instructions, connecting the discharge lines of indoor & out door units, with and including taking down existing u/s copper pipe of any type, complete all as specified and as directed by Engineer-in-Charge. | 70 | Running Metre | 60 ₹4,200 Lowest | 250 ₹17,500 | 80 ₹5,600 |
| 7.00 | All as per Serial Item No. 6 here-in-before but for copper pipe of 3/8" inch outer dia, complete all as specified. | 50 | Running Metre | 65 ₹3,250 Lowest | 250 ₹12,500 | 90 ₹4,500 |
| 8.00 | All as per Serial Item No. 6 here-in-before but for copper pipe of 1/2" inch outer dia, complete all as specified. | 50 | Running Metre | 75 ₹3,750 Lowest | 250 ₹12,500 | 95 ₹4,750 |
| 9.00 | All as per Serial Item No. 6 here-in-before but for copper pipe of 5/8" inch outer dia, complete all as specified. | 50 | Running Metre | 95 ₹4,750 Lowest | 340 ₹17,000 | 110 ₹5,500 |
| 10.00 | S&F Round flexible electric cable of size 3core x 2.5 sqmm, PVC insulated, PVC sheathed, multistranded copper conductor cable, 1100 Volts, FRLS Grade, ISI marked, with and including taking down old u/s cable of any type, complete all as specified. | 100 | Running Metre | 35 ₹3,500 Lowest | 140 ₹14,000 | 45 ₹4,500 |
Tender Value
₹13.5 L
EMD Value
₹27,000
Closing Date
29 Jul 2025, 6:00 pmClosed
Garrison Engineer
Military Engineer Services, Garrison Engineer, Laxmi Tek, Camp Belgaum
COMPREHENSIVE MAINTENANCE AND REPAIR TO COOLING APPLIANCES, AIR CONDITIONING AND UPS UNDER GE BELGAUM
2025_MES_716863_1
8642/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Belgaum
Please refer tender documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Belgaum
₹27,000
16 Sept 2025
26 Jun 2025
31 Jul 2025
26 Jun 2025
29 Jul 2025
10 Jul 2025
Amount
Repair / Maintenance of window/ split type air conditioner, water cooler etc., any capacity any size, testing all the components / parts, identifying the defective parts & reporting to Engineer-in-Charge, cleaning the filter, cooling system, checking of wiring, condenser / evaporator cleaning the unit with blower motor, with and including replacement of minor parts such as wires, bolts, nuts, pads, checking air flow, temperature, working condition for smooth functioning, sealing the pipe hole, checking drain pipe etc., and maintaining properly the record, complete all as specified and as directed by Engineer-in-Charge. Note: Quoted rate shall be inclusive for rectifying all the defects and make the unit functional and in working condition.
Servicing of Split type Air conditioner of 1.5 TR/2.0TR capacity by disconnecting all the electrical connections, servicing and cleaning the indoor unit & outdoor unit using power jet spray only (external) with suitable foam type cleaning agent duly securing the indoor unit with waste water collecting bag to avoid the spread of water in the working area and out door unit, complete all as specified and as directed by Engineer-in-Charge.
S&F PVC flexible drain pipe, corrugated type including bends, saddles etc., for split type ACs as per existing size, fixed on wall, with and including taking down existing u/s drain pipe of any length, complete all as specified.
S&F Factory made sealed reciprocating Compressor of Copper Condenser type, pre-charged with suitable refrigerant gas as per manufacturers instructions, suitable for window / split type AC 1.5 TR capacity of any model /make, with mounting assembly such as rubber, springs, etc., fixing after disconnecting all electrical connections, bragging the suction / discharge line, pressure leak proof testing, with and including taking down existing u/s compressor of any type, complete all as specified and as directed by Engineer-in-Charge.
S&F Factory made sealed reciprocating Compressor of Copper Condenser type, pre-charged with suitable refrigerant gas as per manufacturers instructions, suitable for window / split type AC 2.0TR capacity of any model /make, with mounting assembly such as rubber, springs, etc., fixing after disconnecting all electrical connections, bragging the suction / discharge line, pressure leak proof testing, with and including taking down existing u/s compressor of any type, complete all as specified and as directed by Engineer-in-Charge.
S&F Solid drawn copper pipe of 1/4" inch outer dia, with and including necessary brazing, soldering, flaring, fittings, pipe supports, with all accessories as per manufacturers instructions, connecting the discharge lines of indoor & out door units, with and including taking down existing u/s copper pipe of any type, complete all as specified and as directed by Engineer-in-Charge.
All as per Serial Item No. 6 here-in-before but for copper pipe of 3/8" inch outer dia, complete all as specified.
All as per Serial Item No. 6 here-in-before but for copper pipe of 1/2" inch outer dia, complete all as specified.
All as per Serial Item No. 6 here-in-before but for copper pipe of 5/8" inch outer dia, complete all as specified.
S&F Round flexible electric cable of size 3core x 2.5 sqmm, PVC insulated, PVC sheathed, multistranded copper conductor cable, 1100 Volts, FRLS Grade, ISI marked, with and including taking down old u/s cable of any type, complete all as specified.
S&F Round flexible electric cable of size 4core x 2.5 sqmm, PVC insulated, PVC sheathed, multistranded copper conductor cable, 1100 Volts, FRLS Grade, ISI marked, with and including taking down old u/s cable of any type, complete all as specified.
Dismantling the chocked or leaked condenser of the air conditioner of capacity of any type & any capacity, leak testing with dry nitrogen gas, cutting, brazing & testing the refrigerant flow system and cleaning and testing the same with nitrogen gas and necessary gas welding for any leakages and including testing the system after rectification of leaks, complete all as specified and as directed. Note: Refrigerant charging shall be measured and paid separately under respective item.
Supply and charging / top up of new refrigerant gas R-22, complete all as specified.
Supply and charging / top up of new refrigerant gas R-32, complete all as specified.
Supply and charging / top up of new refrigerant gas R-134A, complete all as specified.
Supply and charging / top up of new refrigerant gas R-600, complete all as specified.
S&F Sheet metal clad SPN enclosure (20Amps) with a 2 pin and earth plug & socket type, with and including one single pole MCB 25/32Amp, SP, 10kA, C series, 240Volt with connections, with and including taking down old u/s enclosure, complete all as specified and as directed.
S&F Mild Steel work such as angle iron, flat etc., with and including fabricating / moulding /welding etc., for base frame work of cooling appliances, complete all as directed.
S&F Blower motor for indoor unit suitable for split AC of any model /make of capacity 1.5/2TR, with and including taking down old u/s motor, complete all as specified and as directed.
S&F Blower drum for indoor unit suitable for split AC of any model /make of capacity 1.5/2TR, with and including taking down old u/s drum, complete all as specified and as directed.
S&F Power Contactor, 2 pole, suitable for split AC of any model /make of capacity 1.5/2TR, with and including taking down old u/s contactor, complete all as specified and as directed.
S&F NO / NC multi contactor, 240Volt, suitable for split AC of any model /make of capacity 1.5/2TR, with and including taking down old u/s contactor, complete all as specified and as directed.
S&F Swing motor suitable for split AC of any model /make of capacity 1.5/2TR, with and including taking down old u/s motor, complete all as specified and as directed.
S&F voltage stabilizer 5KVA, single phase, 230Volt, 50 Hz, capacity wall mounting type suitable for 1.5 TR air conditioners with low/ high voltage cut off and intelligent time delay 3 minute +/- 20 seconds of working voltage range input and output voltage 230V, +/- 2%, (170V - 270V), with and including taking down old u/s stabilizer, complete all as specified and as directed.
S&F condenser fan motor (copper wound type) for outdoor unit, suitable for split AC of any model /make of capacity 1.5/2TR, with and including taking down old u/s condenser fan motor, complete all as specified and as directed.
S&F condenser fan motor (copper wound type) suitable for window type AC of any model /make of capacity 1.5/2TR, with and including taking down old u/s condenser fan motor, complete all as specified and as directed.
S&F condenser fan motor (copper wound type) suitable for water cooler of any model /make of capacity 40/80Ltrs, with and including taking down old u/s condenser fan motor, complete all as specified and as directed.
S&F condenser fan motor (copper wound type) suitable for water cooler of any model /make of capacity 60/120Ltrs, with and including taking down old u/s condenser fan motor, complete all as specified and as directed.
S&F Copper capillary tube with filter / strainer, necessary cutting / brazing etc., suitable for Split/Window type ACs 1.5/2Ton, water cooler of any model /make of capacity, with and including taking down old u/s capillary tube, complete all as specified and as directed.
S&F Relay Assembly suitable for Split/Window type ACs 1.5/2Ton of any model /make, reconnecting the same with all electrical connections, with and including taking down old u/s relay assembly, complete all as specified and as directed.
S&F Relay Assembly suitable for Water Coolers of capacity 40/80Ltrs & 60/120Ltrs of any model /make, reconnecting the same with all electrical connections, with and including taking down old u/s relay assembly, complete all as specified and as directed.
S&F Starting Capacitor 80 to 100Mfd suitable for compressor of Split / Window ACs / Water Coolers of any capacity & any model /make, reconnecting the same with all electrical connections, with and including taking down old u/s capacitor, complete all as specified and as directed.
S&F Running Capacitor 50±2 Mfd suitable for compressor of Split / Window ACs / Water Coolers of any capacity & any model /make, reconnecting the same with all electrical connections, with and including taking down old u/s capacitor, complete all as specified and as directed.
S&F Running Capacitor 45 to 50Mfd suitable for compressor of Split / Window ACs / Water Coolers of any capacity & any model /make, reconnecting the same with all electrical connections, with and including taking down old u/s capacitor, complete all as specified and as directed.
S&F Running Capacitor 36Mfd suitable for compressor of Split / Window ACs / Water Coolers of any capacity & any model /make, reconnecting the same with all electrical connections, with and including taking down old u/s capacitor, complete all as specified and as directed.
S&F Fan Motor Capacitor suitable for Split ACs 1.5/2TR capacity of any model /make, reconnecting the same with all electrical connections, with and including taking down old u/s capacitor, complete all as specified and as directed.
S&F Fan Motor Capacitor suitable for Water Coolers of capacity 40/80 & 60/120Ltrs of any model /make, reconnecting the same with all electrical connections, with and including taking down old u/s capacitor, complete all as specified and as directed.
M&L for Internal Control Wiring with PVC insulated copper wire single core with clips, terminal connections etc., and testing after re-wiring, suitable for split AC of any model /make of capacity 1.5/2TR, with and including taking down old u/s control wiring, complete all as specified and as directed.
S&F Remote Circuit PCB Board suitable for Split / Window type AC of 1.5/2TR capacity & any model /make, reconnecting the same with testing for its working condition, with and including taking down old u/s circuit PCB board, complete all as specified and as directed.
Taking out carefully by disconnecting all connections unserviceable remote circuit PCB Board of 1.5/2.0TR capacity split/window type air conditioners and taking to a reputed workshop & replacing all faulty components, making complete functional and testing all functions of remote control, complete to the entire satisfaction of Engineer-in-Charge.
S&F Acoustic ('U' foam) padding suitable for the split type air conditioners of 1.5/2.0Ton Capacity, with and including taking down the old u/s acoustic padding, complete all as directed.
Taking down and shifting of indoor/outdoor unit of split type AC 1.5/2.0TR after disconnecting all electrical connection and Refrigerant copper piping of suction and discharge after pumping down the refrigerant and fixing it in new location at approximate height of 12mtrs with necessary fixing arrangement, with and including replacing the electric cable and testing complete unit, complete all as specified and as directed. Note: (i) Required copper pipe and Refrigerant Gas will be measured and paid separately. (ii) The cost of transportation, crane/fork for lifting required to shift the outdoor/ indoor units are deemed to be included in the quoted rate.
S&F Cooling Coil with 100% copper tubing with aluminium fins & anti-corrosion coating, suitable for split type AC of any model /make of capacity 1.5 /2TR, with and including taking down existing u/s coil, complete all as specified and as directed. Note: Refrigerant Gas will be measured and paid separately.
S&F AC Stand for wall mounting outdoor unit suitable for split type air conditioners of 1.5/2.0Ton Capacity, with and including taking down the old u/s stand, complete all as directed.
S&F Thermostat Assembly suitable for Split/Window type ACs 1.5/2Ton of any model /make, reconnecting the same with all electrical connections, with and including taking down old u/s thermostat assembly, complete all as specified and as directed.
S&F Thermostat Assembly suitable for Water Coolers of capacity 40/80Ltrs & 60/120Ltrs of any model /make, reconnecting the same with all electrical connections, with and including taking down old u/s thermostat assembly, complete all as specified and as directed.
M&L for Servicing of water coolers any capacity and size by disconnecting all electric connections, cleaning all the components with cleaning agent, removing dirt / scales / rust and spraying clean water twice, re-fixing back duly checking the foundation nuts and bolts of condenser / blower, checking the wiring of blower motor, motor fan belt, rubber gaskets of tank door, cleaning the unit and storage tank properly, complete all as specified and as directed.
S&F Stainless Steel drain tray with PVC flexible pipe, suitable for Water Coolers of capacity 40/80Ltrs & 60/120Ltrs of any model /make, reconnecting the same with inlet pipe with holding clamps, with and including taking down old u/s drain tray, complete all as specified and as directed.
S&F Factory made sealed Compressor of Copper Condenser type, pre-charged with suitable refrigerant gas as per manufacturers instructions, suitable for water coolers of 40/80Ltrs capacity and any model /make, with mounting assembly such as rubber, springs, etc., fixing after disconnecting all electrical connections, bragging the suction / discharge line, pressure leak proof testing, with and including taking down existing u/s compressor of any type, complete all as specified and as directed by Engineer-in-Charge.
S&F Factory made sealed Compressor of Copper Condenser type, pre-charged with suitable refrigerant gas as per manufacturers instructions, suitable for water coolers of 60/120Ltrs capacity and any model /make, with mounting assembly such as rubber, springs, etc., fixing after disconnecting all electrical connections, bragging the suction / discharge line, pressure leak proof testing, with and including taking down existing u/s compressor of any type, complete all as specified and as directed by Engineer-in-Charge.
S&F Chromium Plated Push cock / Lifting cock, fancy type, suitable for 15mm bore dia pipe, suitable for Water Coolers of capacity 40/80Ltrs & 60/120Ltrs of any model /make, with and including taking down old u/s push cock, complete all as specified and as directed.
S&F Float / Ball Valve, CP, fancy type, suitable for 15mm bore dia pipe, suitable for Water Coolers of capacity 40/80Ltrs & 60/120Ltrs of any model /make, with and including taking down old u/s Ball valve, complete all as specified and as directed.
S&F PVC connection 450mm long with heavy duty ferrules, suitable for 15mm bore dia pipe, suitable for Water Coolers of capacity 40/80Ltrs & 60/120Ltrs of any model /make, with and including taking down old u/s PVC connection, complete all as specified and as directed.
S&F Fibre / Metalic fan blade for condensing blower motor of Split/Window type ACs 1.5/2Ton of any model /make, reconnecting the same with all electrical connections, with and including taking down old u/s fan blade, complete all as specified and as directed.
S&F Fibre / Metalic fan blade for condensing blower motor of Water Coolers of capacity 40/80Ltrs & 60/120Ltrs of any model /make, reconnecting the same with all electrical connections, with and including taking down old u/s fan blade, complete all as specified and as directed.
M&L for Spray painting with synthetic enamel paint of approved tint & colour, with and including preparation of old surfaces of Water Coolers of capacity 40/80Ltrs & 60/120Ltrs of any model /make, complete all as specified and as directed.
S&F Plug top, 3Pin 5Amp, 240Volts, single phase, ISI marked, suitable for water coolers/ACs with and including taking down old u/s Plug Top, complete all as specified and as directed.
S&F Plug top, 3Pin 15Amp, 240Volts, single phase, ISI marked, suitable for water coolers/ACs with and including taking down old u/s Plug Top, complete all as specified and as directed.
S&F Cordless Remote with cell of size AAA, 1.5V, wall fixing clamp, suitable for Split AC of 1.5/2TR for existing Model /Make with and including taking down old u/s remote, complete all as specified and as directed.
S&F Air Filters suitable for Window / Split tyype AC of 1.5/2TR capacity for existing Model /Make with and including taking down old u/s remote, complete all as specified and as directed.
S&F Fiber Glass insulation sleeves of sizes 5/6/8/10 mm for thermal protection of suction discharge pipes, with and including taking down existing u/s insulation sleeves, complete all as specified and as directed.
S&F Foam heat insulated nitrile tubes of size 1/2" inch dia, including all accessories, with and including taking down existing u/s old tubes, complete all as specified and as directed.
S&F Foam heat insulated nitrile tubes of size 1/4" inch dia, including all accessories, with and including taking down existing u/s old tubes, complete all as specified and as directed.
S&F Poly Vinyl Self adhesive & water proof type name flex sheet of minimum size 4"x3" inches, duly marked / printed the Srl No. & the word "Maintained by GE Belgaum" shape & colour as detailed by Engineer-in-Charge, complete all as specified and as directed.
S&F Battery 12Volt, 80AH for solar power plant, with and including taking down old u/s battery, complete all as specified and as directed.
M/s. VIJAY ELECTRICALS (BID ID -3375526)
Green Ray Enterprises (BID ID -3366892)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .