| 3 | Rejected-Technical SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASPURA CV RAMAN NAGAR BANGALORE 560093 | BENGALURU URBAN | KARNATAKA | 560093 | - | Rejected-Technical Being not eligible as per firm declared as un-enlisted due to death of one of the partner however firm has not sumbitted documents applicable for un-enlisted dider |
| Sl No | Description | Qty | Unit | devan enterprises L2 | UNIVERSAL ENGINEERING L1 |
|---|---|---|---|---|---|
| 1.00 | Comprehensive maintenance of Central Chilled water type AC plant of capacity 140 TR (02 x 70 TR working and 01 x 70 TR standby),Chiller Unit 70 TR - 03 Nos, Chiller pump capacity 5.5 KW- 03 Nos, condensor pump capacity 7.5 KW - 03 Nos alongwith 03 AHUs of capacity (30000 CFM comprising of 1.5 KW heaters -12 Nos, 14000 CFM and 5000 CFM including 02 cooling towers of 90 TR each by OEM or autherised service person for a period of 11 months and technician should visit the AC plant every Quaterly & including emergency visits (as required )during contract period as and when required for the diagnosis of trouble, adjustment, minor repair of dust and cooling tower such as nuts bolts, washers and leakage of dusting parts etc or re-setting of control as well as maintenance of Central Chilled water type AC plant of capacity 140 TR (02 x 70 TR working and 01 x 70 TR standby),Chiller Unit 70 TR - 03 Nos, Chiller pump capacity 5.5 KW- 03 Nos, condensor pump capacity 7.5 KW - 03 Nos alongwith 03 AHUs of capacity (30000 CFM comprising of 1.5 KW heaters -12 Nos, 14000 CFM and 5000 CFM including 02 cooling towers of 90 TR each keeping the AC plant and the accessories in perfect and working condition with the repair/ replacement of all defective/wom out parts/ components, lubricating of the moving parts of the plant all as required without affecting normal functioning of the plant complete all as specified and as directed . | 11 | EACH JOB | 1,23,900 ₹13,62,900 | 1,12,500 ₹12,37,500 Lowest |
| 2.00Note : (a) The tenderers shall have to submit the copy of MOU with OEM M/s BLUE STAR Limited through its authorized service provider as a proof to carry out quarterly maintenance etc recommended by OEM immediatly after commencement of work and strictly follow the company maintenance recommendations. The rates quoted shall be deem to include all such maintenance cost. (b) The contractor shall submit the record of Monthly report for the Monthly maint service carried out by M/s BLUE STAR Limited along with recommendation of necessary repairs and maintenance procured alongwith documentary evidence for claiming payment. The contractor shall produce the "purchase order" issued to M/s Blue Star service provider for Annual Maintenance. (c) Contractors quoted rates shall be deemed to be inclusive of any replacement of miscellaneous or minor parts (costing less than Rs 500/ each part) , such as greasing, oiling, wires, toggle switch, lugs, nuts, cable gland, connector, thimbles, gland packing etc when required or as ordered by Engr in Charge for smooth and uninterrupted operation of the complete system except spares such as mentioned here in after in relevant items of this schedule. (d) The quoted rate is inclusive of descaling etc and including cleaning/washing filters at AHUs 03 Nos and connecting Units every Quaterly complete all as directed failing which a penalty @ Rs. 1000/- per month will be charged. (e) In contract period once Oil sample analysis of chiller compressor oil has to be carried out from M/s BLUE STAR Limited Factory for testing of oil parameters as mentioned in BLUE STAR chiller service mannual. As per the oil analysis report replacment of Oil & Oil Filter for smooth and efficient working of compressor is included in the quoted rate . | |||||
| 3.00(f) In case of any major break down the additional manpower if required will be arranged by the contractor to re-start the plant without any additional cost. (g) The rates quoted shall include extra labour for repairing and N2 pressure testing including N2 gas required for checking of leakage or repairing of compressor and overhauling. Refrigerant gas will be measured in relevant items and rate quoted is inclusive of checking/repair of LT Panel for minor damage in panel if any required as directed . (h) The rates quoted shall include checking of ducting & grill for leakages and repair the same, loose fitting /tightening of ducting etc to reduce vibration & noise and gland packing of pumps etc. make up water tank /expansion tank of hot water circuit and chilled water circuit, installed at the roof of the plant room (i).Monthly comprehensive maintenance inspection report along with nature of repairs carried out incl material consumed during every month shall be submitted to the dept duly signed by technician and contractor. (j) The OEM with proper qualification and experience shall check the plant working conditions as per existing parameters and maintenance of the entire AC Plant comprising of all equipments mentioned above will be done upto 100 % of full efficiency of the system at its optimal efficiency and ensure high uptime of the equipment and the same shall be deemed to be included in the quoted rate . | |||||
| 4.00 | Supply & Fixing in repairs Cast Iron butterfly valves, conforming to IS 13095 of size 125 mm dia complete all as specified and directed. | 3 | EACH | 10,900 ₹32,700 | 6,900 ₹20,700 Lowest |
| 5.00 | Supply & Fixing in repairs Cast Iron butterfly valves, conforming to IS 13095 of size 100 mm dia complete all as specified and directed. | 1 | EACH | 9,800 ₹9,800 | 7,200 ₹7,200 Lowest |
| 6.00 | Supply & Fixing in repairs Cast Iron butterfly valves, conforming to IS 13095 of size 80 mm dia complete all as specified and directed. | 1 | EACH | 6,700 ₹6,700 | 4,600 ₹4,600 Lowest |
| 7.00 | Supply & Fixing in repairs Cast Iron butterfly valves, conforming to IS 13095 of size 50 mm dia complete all as specified and directed. | 1 | EACH | 4,650 ₹4,650 | 2,800 ₹2,800 Lowest |
| 8.00 | Supply & Fixing in repairs Cast Iron Globe Valves, conforming to IS 210 of size 125 mm dia complete all as specified and directed. | 2 | EACH | 35,900 ₹71,800 | 23,000 ₹46,000 Lowest |
| 9.00 | Supply & Fixing in repairs Cast Iron Globe Valves, conforming to IS 210 of size 100 mm dia complete all as specified and directed. | 2 | EACH | 24,000 ₹48,000 | 14,800 ₹29,600 Lowest |
| 10.00 | Supply & Fixing in repairs Cast Iron Globe Valves, conforming to IS 210 of size 80 mm dia complete all as specified and directed. | 2 | EACH | 15,900 ₹31,800 | 9,000 ₹18,000 Lowest |
Tender Value
₹32.0 L
EMD Value
₹64,000
Closing Date
17 Jul 2026, 6:00 pmClosed
Ranjeet Kumar, IDSE, CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
COMPERHENSIVE MAINTENANCE OF AC PLANT (140 TR) AT FMS AT AFS YELAHANKA
2026_MES_773619_1
86238/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Yelahanka
As per Tender Document
8 documents required · 8 mandatory
₹500
GE (AF) Yelahanka
₹64,000
Yes
13 Aug 2026
20 Jun 2026
25 Jul 2026
20 Jun 2026
17 Jul 2026
4 Jul 2026
20 Jun 2026 - 24 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive maintenance of Central Chilled water type AC plant of capacity 140 TR (02 x 70 TR working and 01 x 70 TR standby),Chiller Unit 70 TR - 03 Nos, Chiller pump capacity 5.5 KW- 03 Nos, condensor pump capacity 7.5 KW - 03 Nos alongwith 03 AHUs of capacity (30000 CFM comprising of 1.5 KW heaters -12 Nos, 14000 CFM and 5000 CFM including 02 cooling towers of 90 TR each by OEM or autherised service person for a period of 11 months and technician should visit the AC plant every Quaterly & including emergency visits (as required )during contract period as and when required for the diagnosis of trouble, adjustment, minor repair of dust and cooling tower such as nuts bolts, washers and leakage of dusting parts etc or re-setting of control as well as maintenance of Central Chilled water type AC plant of capacity 140 TR (02 x 70 TR working and 01 x 70 TR standby),Chiller Unit 70 TR - 03 Nos, Chiller pump capacity 5.5 KW- 03 Nos, condensor pump capacity 7.5 KW - 03 Nos alongwith 03 AHUs of capacity (30000 CFM comprising of 1.5 KW heaters -12 Nos, 14000 CFM and 5000 CFM including 02 cooling towers of 90 TR each keeping the AC plant and the accessories in perfect and working condition with the repair/ replacement of all defective/wom out parts/ components, lubricating of the moving parts of the plant all as required without affecting normal functioning of the plant complete all as specified and as directed . | 11 | EACH JOB | 16 | ₹176 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
86238Tender.pdf
Tender Documents • 1.97 MB
BOQ_866230.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .