| 1 | L1₹33.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹38.3 L+₹4.5 L (13.4%)Rejected-Finance BANKIM CHANDRA ROAD HAKIMPARA SILIGURI DIST DARJEELING PIN 734001 W B | JALPAIGURI | WEST BENGAL | 734001 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹38.8 L+₹5.0 L (14.7%)Rejected-Finance HO MALLAGURI NORTH P O CHAMPASARI PS PRADHAN NAGAR VILL PRADHAN NAGAR DISTT DARJEELING W B PIN 734003 | DARJEELING | WEST BENGAL | 734003 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹41.7 L+₹7.8 L (23.2%)Rejected-Finance CHOWDHARY APARTMENT BLOCK II FLAT NO 7 3RD FLOOR PUNJABIPARA SEVOKE ROAD SILIGURI DIST DARJEELING 734001 | JALPAIGURI | WEST BENGAL | 734001 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹41.7 L+₹7.9 L (23.2%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹41.8 L
EMD Value
₹83,540
Closing Date
1 Oct 2024, 6:00 pmClosed
GE SEVOKE ROAD
GE Sevoke Road Post Salugara Dist Jalpaiguri PIN 734008
SPECIAL REPAIR TO FLOORING AND INTERNAL ELECTRIFICATION WORK OF CERTAIN BUILDINGS AT SEVOKE ROAD MIL STN UNDER GE SEVOKE ROAD
2024_MES_670612_1
8387/SEV OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
GE SEVOKE ROAD
AS PER TENDER DOCUS
7 documents required · 7 mandatory
₹0
₹83,540
Yes
13 Nov 2024
3 Sept 2024
4 Oct 2024
3 Sept 2024
1 Oct 2024
18 Sept 2024
4 Sept 2024 - 14 Sept 2024
Amount
Demolition of cement concrete (un reinforced) of any description and in in any position not otherwise specifically provided for, removing rubbish off the premises etc complete all as specified and directed.
Materials and labour for Pavement Quality Concrete(PQC) of minimum 28 days field Flexural strength of 45Kg/ Sqcm or 4.5 Mpa, aggregate gradation as per Table 3 of IRC 15 2017, coarse aggregate of clean , hard strong, dense non-porous and durable pieces of crushed stone or gravel, fine aggregates of clean natural sand crushed stone sand or combination of both using minimum 360 kg/cum of cement with non-circular virgin synthetic fibre of 12-18 mm length, specific gravity 1.34 to 1.39, UV stable, alkali resistant, with equivalent dia 15-40 micron, minimum melting temperature as 240°C and minimum tensile strength of 300 Mpa and at the rate as specified by the manufacturer. PQC laid, spread and compacted with slip-form paver of minimum 7.50 m width , including curing and tining by Texturing cum Curing Machine complete all as specified and directed. Required surface texturing to be done as specified in IRC 15-2017complete all as specified and directed
Materials and labour for repairing of old damaged PCC floor of hangar using Structural Grade Repair mortar after preparation of surface and application of bonding agent including repair to contruction joints, surface preparation and allied works complete all as directed by the Engr-in-Charge
Supplying and applying 2mm thick cementitious Underlay complete with following stages of work:- (i) The concrete surface shall be prepared free from dust, laitance, oil and grease. Light Grinding can be done to in case there is deposition on the floor. (ii) Cleaning the surface , making it absolutely free from dust, oil or any type of deleterious materials etc by Mechanical grinding, and chipping off the loosely adhered mortar. The cleaning and preparation of the RCC surface must be carried out thoroughly to leave a sound base for the application. Release oil and other contaminants which may impair adhesion must be removed prior to the application of the primer, use of surface grinder is must. If any surface crack observed that shall be cut “V” groove & be packed with polymer modified mortar. (iii) Supply and application of primer to the prepared surface , followed by supply and application of cement based, trowel applied two component heavy duty flooring @ 2mm thickness using materials of approved make. The cementitious underlay should achieve the following properties ,Compressive strength 7 days >30 N/mm2, 28 days >40 N/mm2, Flexural Strength 28 days >7 N/mm2, Adhesion Strength 28 days 1.5 N/mm2, Mixed Density 3250 Kgs/m3, Polymer : Powder ratio 0.25. Note:- Work shall be executed as per manufacturers instruction through authorised applicator only.)
Materials and labour for painting lines, dashes arrows ,letter etc on road pavements etc not exc. 15 cm width with road marking paint white or golden yellow including preparation with adequate numbers of coats, complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
Taking down ceiling fans/exhaust fan of any size,dismantling blades and removing fan and blades to MES store complete all as specified and directed.
Materials and labour for concealed point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead, drawing through in and including PVC rigid conduit of size not less than 20mm, with all fittings & accessories including provn of MS sunk terminal box of appropriate size suitable for switch fixed flush to wall for mounting switch, sockets, fan regulators etc with 3mm thick hylum sheet top cover with screws & cup washers for one light / fan point / call bell complete. NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates. all as specified and directed.One light/fan/call bell point controlled by one switch one way 5 Amps
All as per Item No.8 above but for One 2/3 pin socket outlet 5/6Amps on independent board
All as per Item No.8 above but for One 2/3 pin socket outlet 5/6 Amps on the same board with other switches.
All as per Item No.8 above but for one switch socket combination 15/16 Amps on independent board with cable 2.5 sq mm size and earth wire 2.5 sqmm
All as per Item No.8 above but for one switch socket combination 15/16 Amps on independent board with cable 4 sq mm size and earth wire 4 sqmm
Materials and labour for point wiring as required for height of ceiling upto 15 m from floor as per site requirement with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 2.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 2.5 sqmm green in colour as earth lead, drawing through in and including PVC rigid conduit of size not less than 20mm, with all fittings & accessories including provn of MS sunk terminal box of appropriate size suitable for switch fixed flush to wall for mounting switch, sockets, fan regulators etc with 3mm thick hylum sheet top cover with screws & cup washers for one light / fan point / call bell complete. NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface and necessary scaffolding with safety measures for additional height is deemed to be included in the unit quoted rates all as specified and directed.One light/fan/call bell point controlled by one switch one way 5 Amps
Supply and fixing Switch piano, flush type, single pole, one way switch 5 Amps.
Supply and fixing Switch socket combination 2 in 1, 5 Amps flush type.
Supply and fixing Switch socket combination multipurpose 5 A/16 Amps,5 in 1, flush type.
Supply and fixing Ceiling rose surface PVC 3 terminals 50x25mm all as directed.
Supply and fixing Socket outlet 3 Pin, 5 Amp flush type universal, 240 volts, complete all as specified all as directed.
Supply and fixing Bell Push Flush type 5 Amp, 240 volt all as specified.
Supply and fixing Bell Ding-Dong AC 230 V Single Pole complete all as specified and as directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete alongwith remote control and fan hanging bolt with fushner all as specified and as directed.
Supply and fixing electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200 sweep/1400 mm, 120 Watt complete all as specified and directed.
Supply, fixing and connecting exhaust fan steel body AC single Phase. 230V of size 600m sweep with, blades, and frame and louvers complete all as specified and as directed.
Supply, fixing and connecting exhaust fan made of polycarbonate/sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and as directed.
Supply, fixing and connecting in repair exhaust fan metal body with louvers shutter, voltage 230V, 50 Hz, Copper winding of sweep 450mm, including drilling holes in wall for fixing and connecting with suitable size copper wire complete all as specified and as directed.
Taking down existing unserviceable light fitting and Supply and fixing energy saving and environmental friendly long life LED security/street Light fittings 35 watts, made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover, IP 66 protection, inbuilt driver, connecting with suitable size copper wire, with 25mm bore 1.5 m long medium grade GI bracket made to shape complete all as specified and as directed.
Taking down existing unserviceable light fitting and Supply and fixing energy saving and environmental friendly long life LED security/street Light fittings 25 watts, made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover, IP 66 protection, inbuilt driver, connecting with suitable size copper wire, with 25mm bore 1.5 m long medium grade GI bracket made to shape complete all as specified and as directed.
Taking down existing unserviceable light fitting and Supply and fixing new decorative box type surface and wall mounted 20 Watt LED light fittings, 4 feet long, with aluminium housing and integrated electronic driver, fixed to walls/ceiling, environmental friendly, energy efficient ready to use pack .
Taking down existing unserviceable light fitting and Supply and fixing new decorative box type surface and wall mounted 9/10 Watt LED light fittings, 2 feet long, with aluminium housing and integrated electronic driver, fixed to walls/ceiling, environmental friendly, energy efficient ready to use pack .
Supply and fixing in repair highbay light fitting having LED light source of 120 Watts, lumen efficiency upto 130LPW, IP 65/66 protection with front toughened glass including necessary connecting arrangement upto height of 15 m as per site requirement complete all as specified and directed. by Engineer-in-charge.
Supply and fixing in repair MCB distrubution board TPN 4way, double door, IP 43, IK-09, sheet steel, phosphatised,powder coated with 200 amps rated bus-bar,neutral link,earth bar and din rail, 415 V, including taking down existing unserviceable DB with MCBs complete all as specified and directed. by Engineer-in-charge.
Supply and fixing in repair MCB distrubution board SPN 12 way, double door, IP 43, IK-09, sheet steel, phosphatised, powder coated with 200 amps rated bus-bar,neutral link, earth bar and din rail, 240 V, including taking down existing unserviceable DB with MCBs complete all as specified and directed. by Engineer-in-charge.
Supply and fixing in repair MCB distrubution board SPN 8 way, double door, IP 43, IK-09, sheet steel, phosphatised, powder coated with 200 amps rated bus-bar,neutral link, earth bar and din rail, 240 V, including taking down existing unserviceable DB with MCBs complete all as specified and directed. by Engineer-in-charge.
Supply and fixing MCB Tripple pole and neutral (TPN), 415 volts 63 Amps 10 KA rupturing capacity, C series
Supply and fixing MCB Single pole and neutral (SPN), 240 volts 32 Amps 10 KA rupturing capacity, C series
Supply and fixing MCB Single pole (SP), 240 volts 5 to 32 Amps 10 KA rupturing capacity, C series
Materials &Labour for submain wiring with two single core PVC insulated, unsheathed, stranded copper conductor, FRLSH, of size 2.5 Sqmm and one single core PVC insulated, unsheathed stranded copper conductor FRLSH, of size 2.5 Sqmm green in colour as earth continuity conductor connected to existing main switch board / distribution board of each building / qtr as ordered, drawn into and including 20 mm dia PVC conduit (medium grade) with all fitting & accessories and testing on completion including taking down old unserviceable sub-main wiring complete all as specified and directed by Eng-in-Charge . (Note: Two runs of 2.5 Sqmm cable and one run of 2.5 Sqmm earthing cable along with conduit altogether shall be measured as one unit.)
Materials &Labour for submain wiring with two single core PVC insulated, unsheathed, stranded copper conductor, FRLSH, of size 6.0 Sqmm and one single core PVC insulated, unsheathed stranded copper conductor FRLSH, of size 6.0 Sqmm green in colour as earth continuity conductor connected to existing main switch board / distribution board of each building / qtr as ordered, drawn into and including 20 mm dia PVC conduit (medium grade) with all fitting & accessories and testing on completion including taking down old unserviceable sub-main wiring complete all as specified and directed by Eng-in-Charge . (Note: Two runs of 6 Sqmm cable and one run of 6 Sqmm earthing cable along with conduit altogether shall be measured as one unit.)
Materials &Labour for submain wiring with two single core PVC insulated, unsheathed, stranded copper conductor, FRLSH, of size 10 Sqmm and one single core PVC insulated, unsheathed stranded copper conductor FRLSH, of size 10 Sqmm green in colour as earth continuity conductor connected to existing main switch board / distribution board of each building / qtr as ordered, drawn into and including 20 mm dia PVC conduit (medium grade) with all fitting & accessories and testing on completion including taking down old unserviceable sub-main wiring complete all as specified and directed by Eng-in-Charge . (Note: Two runs of 10 Sqmm cable and one run of 10 Sqmm earthing cable along with conduit altogether shall be measured as one unit.)
Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, etc, or for shafts, wells, cesspits, manholes, pier holes, cable trench etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed.
Supply and laying or fixing or passing through pipe and connecting UG, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core in replacement of existing cable complete all as specified.
Supply and laying or fixing or passing through pipe and connecting UG, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core in replacement of existing cable complete all as specified.
Materials and labour for GI pipe medium grade grouted in ground all as specified for 40 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified and directed.
Supply & laying 63 mm outside dia double wall corrugated pipe(DWCPE) for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed.
Materials and labour for boring holes upto 2mtr deep in soil under roads/PCC as directed for cable passing through pipes of required size and disposal of soil to a distance not exc. 50m. (Note: Connected items like Pipes is measured and paid seperately under relevant items).
Materials and labour for PCC (1:3:6) type C-2 (using 40 mm graded aggregate) as in filling, repair to path etc., finished even and smooth at road and broken PCC repair without using extra cement all as directed.
Supply and fixing as in repairs MCCB four pole , 415 Volt, 100 Amps,25 KA , with thermal magnetic protection complete all as specified and directed .
Supply and fixing as in repairs MCCB four pole , 415 Volt, 63 Amps,25 KA , with thermal magnetic protection complete all as specified and directed .
Supply and fixing electric water heater (Geyser),storage type, steel body, with copper inner tank and heating element upto 3 KW, 50 lits capacity, BEE 5 star rating, complete all as specified and directed.
Materials and labour for earthing complete with galvanized steel pipe electrode 40mm bore , medium grade, 2.5 meters length, buried directly and preferably vertically in ground with top edge not less than 1.25 meters below ground level connected with earthing lead galvanized iron strip of size 25x5 mm connected to galvanized earth pipe by means of bolts, nuts, checknuts and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanized steel tube for watering with one end fix with cast iron funnel and wire-mesh , with protection pipe of 32 mm dia light grade galvanized steel tubing upto 7.5 meters length for drawing earthlead including common salt, charcol , bentonite in alternate layers etc, complete all as shown in EP number 2 of SSR part-1 including testing on completion and including taking down old u/s earthing & testing complete all as specified and as directed.
M/S ASHWIRBAD WOODCRAFT (BID ID -3109566)
M/S STANDARD CONSTRUCTION CO (BID ID -3099362)
ASSOCIATED TRADING CORPORATION (BID ID -3111584)
M/S L N CHOWDHURY (BID ID -3121358)
D.D. BROTHERS (BID ID -3105937)
LIBERAL ENGINEER CONSTRUCTION (BID ID -3106106)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .