Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.1 LAccepted-AOC | ₹49.1 L | L1 | Accepted-AOC L1 |
| 2 | L2₹50.5 LRejected-AOC 1901 VIJAY NAGAR RAMPUR JABALPUR | JABALPUR | JABALPUR | MADHYA PRADESH | 482008 | ₹50.5 L | L2 | Rejected-AOC L2 |
| 3 | L3₹51.1 LRejected-AOC | ₹51.1 L | L3 | Rejected-AOC L3 |
| 4 | L4₹51.2 LRejected-AOC 301 2 PATEL MOHALLA RAMPUR JABALPUR | JABALPUR | JABALPUR | MADHYA PRADESH | ₹51.2 L | L4 | Rejected-AOC L4 |
| 5 | L5₹54.7 LRejected-AOC | ₹54.7 L | L5 | Rejected-AOC L5 |
Tender Value
₹83.6 L
EMD Value
₹1.7 L
Closing Date
2 Dec 2025, 3:30 pmClosed
CE (EHT-Construction)
Block No. 4, Shakti Bhawan, Rampur, Jabalpur
Civil works viz. Replacement of roof sheets, water harvesting system and other misc. RandM works etc. at HRDI premises Nayagaon Jabalpur. (ii).Civil works viz. Leveling, hume pipe culvert, Boundary Wall, Choukidar post,Toilet etc. AE TLM Jabalpur.
2025_MPPTC_461316_1
1178
Open Tender
Civil Works - Others
180 days
Jabalpur
As per tender
14 documents required · 14 mandatory
₹2,360
₹1.7 L
Yes
23 Apr 2026
10 Nov 2025
3 Dec 2025
10 Nov 2025
2 Dec 2025
10 Nov 2025
30122329.109.2 "Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete:..250x16 mm"
30114642.1Surface dressing of the ground including removing vegetation and in.equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. in all kinds of soil.
30113099.113.1 "Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:.125 mm"
301332615.6.1 "Demolishing brick work manually/ by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50 metres leadas per direction of Engineer-in- Charge...In lime mortar with old mughal bricks."
301332315.3Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge.
301335215.19.2 "Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in:..Channels, angles, tees and flats"
301336015.27.1 "Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 metres lead of:..G.S. Sheet"
301336115.27.2 "Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 metres lead of:..Asbestos/ Non asbestors sheet"
301253610.14.1"Steel work in built up M.S. tubularsection (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washersetc. complete...Hot finished welded type tubes"
30117776.5.2 "Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete...Cement mortar 1:6 (1 cement : 6 sand)"
301317014.3Fixing chowkhat in existing opening in brick / RCC wall with dash fasteners/ chemical fastener of appropriate size (3nos on each vertical member of door chowkhat and 2 nos. on each vertical member of window chowkhats) including cost of dash fasteners/ chemical fastener.
301307813.41Providing and applying white cement based putty of average thickness 1 mm, of approved brand over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete. Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of Chief Engineer will be required.
301302013.3.2"20 mm cement plaster of mix :..1:6 (1 cement : 6 sand)"
301316614.1Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and underincluding cutting the patch inproper shape, raking out joints and preparing and plastering the surface of the walls completeincluding disposal of rubbish tothe dumping ground within 50metres lead : With cement mortar 1:4 (1 cement : 4 sand).
301322414.36Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One or more coats on old work.
301324214.51.1 "Finishing walls with Acrylic Smooth exterior paint of required shade :..Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface).."
301457224.11"Providing and fixing Precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or .as desired by Engineer-in- charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and .trusses and including cutting to size and shape wherever required. "
301457324.12.1 Providing and fixing precoatedgalvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5- 7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self-drilling/ self-tapping screws complete :Ridges plain (500 - 600mm).
301385218.7.2 "Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipe and fittings with onestep CPVC solvent cement, trenching, refilling andtesting of joints complete as per direction of Engineer-in- Charge..External Work..20 mm nominal outer dia. Pipes.."
301385018.6.2.4 "Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in-Charge..Concealed work including cutting chases and making good the walls etc...32 mm nominal outer dia. Pipes."
301444421.1.2.2 "Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved .make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, .including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) .:For shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required .including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for .separately)..Powder coated aluminium (minimum thickness of powder coating 50 micron) ."
300748123.3.3Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm ).
301445621.5.2 "Providing and fixing double action hydraulic floor spring of approved brand and manufacture .conforming to IS : 6315, having brand logo embossed on the body /plate with double spring .mechanism and door weight upto 125 kg., for doors, including cost of cutting floors , embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge :.With brass cover plate - minimum 1.25 mm thickness. "
301271511.49Providing and laying Ceramic glazed floor tiles 300x300 mm or more (having thickness 6 to 7mm) of 1st quality conforming to IS : 15622 of approved make in any colours and shade laid on20 mm thick Cement Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching pigment etc., complete.
301259311.5Cement concrete pavement with Cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) including finishing complete.
301452822.23"Providing water proofing treatment over Roof, Wall, Chhajjas, Balcony with Rubberized elastomeric cold applied liquid waterproofing membrane blend of special resin and rubber with more than 1300% elongation (confirming ASTM-D2370-98), at leakage/seepage area consisting of the following operation. (i) Removal of damaged waterproofing treatment if any like bituminous membrane / plaster/ brick bat koba/screeding etc. .(ii) Surface preparation: Roughening of surface by scrubbing with steel wire/ Nylon brush/ Removing all dust particles and washing with adequate water to clean completely, opening of cracks in 'V' groove in size of 5mm x 10m (WxD), filling of cracks with elastomeric creak filler/PU sealent repair of potholes and holor making on roof surface by polymer mortar with adding SBR bonding agent. (iii) Providing and applying 1st coating of rubberized elastomeric liquid membrane as primer (ratio 1:2 1 part liquid membrane and 2 part water) by brush/ Roller/ Spray having minimum thickness of 70-80 micron. Allow the coating to set in natural air for minimum 2 hrs, then put reinforcement by laying 45gsm fibre glass mesh and applying 2nd coat of rubberized elastomeric liquid membrane .(Ratio: 1 part membrane and 20% water) with minimum thickness 100-120 micron. Allow the coating to set in natural air for minimum 12 hrs. (iv) Providing and applying 3rd coat of rubberized elastomeric liquid membrane .(Ratio: 1 part membrane and 10% water). Total DFT (Dry film thickness) thickness after 3rd coat must be 280-300 micron and consumption in three coats @ 6.5kg for 10sqm. (v) Providing and applying 4th and 5th coat .of High quality waterproof membrane in white colour, single component special synthetic resin based flexible thixotropic white color coating with excellent UV resistance (SRI - 144) with more than 300% elongation .(confirming ASTM D 412-98) in ratio: 1 part membrane and 10% water thickness of 200 micron DFT in two coats, with average consumption @ 5kg per 10 sqm. After application of fourth coat let it air dry for minimum 3 hrs before application of fifth coat. (vi) The treated area must be tested for water leakage/seepage by flooding with water for 48 .hrs (vi) Application of membrane coating shall be got done by authorized applicator of manufacturer. .(vii) 5 years of service guarantee to be provided. All above operations to be done in order as per direction on Engineer-in-Charge."
301353817.22.1"Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with allfittings and fixtures complete. 10 litre capacity..White"
301295712.62.2"Providing and fixing board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately):..Flat pressed 3 layer medium density particle board or graded particle board.(Grade I) IS: 3087 12 mm thick marked in ceiling with necessary nails etc. complete."
301539711.1.1.1.1"Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing concealed rigid conduit ISI marked of suitable size with PVC insulated FRLS copper earth continuity conductor of green colour, screwless connector for joints as per specification including earthing of regulator etc as required for :-..Light point/fan/ex-fan points...Short point..Using flush type normal accessories"
301539911.1.1.2.1 "Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing concealed rigid conduit ISI marked of suitable size with PVC insulated FRLS copper earth continuity conductor of green colour, screwless connector for joints as per specification including earthing of regulator etc as required for :-..Light point/fan/ex-fan points...Medium point ..Using flush type normal accessories"
301540111.1.1.3.1 "Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insu
lated cable FRLS with copper multi strand conductor ISI marked in existing concealed rigid conduit ISI marked of suitable size with PVC insulated FRLS copper earth continuity conductor of green colour, screwless connector for joints as per specification including earthing of regulator etc as required for :-..Light point/fan/ex-fan points...Long point.Using flush type normal accessories"
301540511.1.2.2.1 "Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing concealed rigid conduit ISI marked of suitable size with PVC insulated FRLS copper earth continuity conductor of green colour, screwless connector for joints as per specification including earthing of regulator etc as required for :-.3 Pin 6 Amp socket outlet on separate board..Medium point.. Using flush type normal accessories"
301540711.1.2.3.1 "Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing concealed rigid conduit ISI marked of suitable size with PVC insulated FRLS copper earth continuity conductor of green colour, screwless connector for joints as per specification including earthing of regulator etc as required for :-.3 Pin 6 Amp socket outlet on separate board..Long point.. Using flush type normal accessories"
301541311.1.3.3.1 "Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing concealed rigid conduit ISI marked of suitable size with PVC insulated FRLS copper earth continuity conductor of green colour, screwless connector for joints as per specification including earthing of regulator etc as required for :-.Call bell/buzzer points..Long point..Using flush type normal accessories"
301549118.3.4"Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-..6 Module PVC box"
301549218.3.5"Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-..8/9 Module PVC box"
301549318.3.6"Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-..12 Module PVC box"
30115894.3.1 "Centering and shuttering including strutting, propping etc. and removal of form work for :..Upto plinth: Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth."
301674937.36.1 "Supply and laying G.I. earth lead duly installed on wall or in G.I. Pipe including connection etc. complete as required...13 sq. mm. ( 4 mm dia )"
301628627.12.3"Supplying of approved make TPN MCB DB metal double door IP 43 protection with provision for FP MCB/ Isolator/ RCCB/ RCBO as incomer and SP MCBs as outgoing inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator):..6 Way (8+18) "
301638528.5.3"Labour charges for fixing sheet steel enclosure, MCB DB surface mounting type, as per accepted practice on 25x5mm flat iron clamp duly embedded in wall, cable connection etc. complete...For item no :-..27.12.3 to 27.12.4 & 27.13.1"
301368417.58.2"Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum wall thickness 3.2mm)..110 mm diameter"
4000328227 NSOR 2.4 M High Boundary Wall as per Standard drawings and details mentioned in SMB
301343616.1.4.2"Boring/drilling bore well of required dia perfectly vertical to receive casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer-in-Charge, upto 90 metre depth below ground level. ..Rocky strata including Boulders. Beyond 90 metre depth...150 mm dia. "
30113141.1.1.1"Transportation By Mechanical Transport including loading, unloading and stacking..Lime, moorum, building rubbish (for 1KM) "
30114732.7.1 "Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, Note:-Excavation of hard rock shall be the property of the contractor subject to recovery. excavated material has to shift from site within 15 days after instruction issued by Engineer-In.Charge otherwise after this penalty will imposed on contractor at the rate of Rs 50 per cum per day...Ordinary rock"
30115352.26"Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing complete.Note: - Maximum thickness of thislayer shall be 20 cm."
301346716.15Supplying, filling, spreading and leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in.charge.
301346816.16Supplying, filling, spreading and leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads and lifts, all complete as per direction of Engineer-in.Charge.
301346916.17Supplying, filling, spreading and leveling coarse sand of size range 1.5 mm to 2 mm inrecharge pit, in required thickness over gravel layer, for all leads and lifts, all complete as per direction of Engineer-in- Charge
301368417.58.2 "Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum wall thickness 3.2mm)..110 mm diameter"
Civil works viz. Leveling, P&F hume pipe culvert, Boundry Wall, Choukidar post, General Toilet and other misllaneous works at AE TLM Premises Nayagaon Jabalpur, 3013328, 15.6.3"Demolishing brick work manually/ by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50 metres leadas per direction of Engineer-in- Charge...In cement mortar."
301332315.3Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in.Charg
30122369.110.4 "Providing and fixing aluminium towerbolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:.200x10 mm"
30115804.1.2.3 "Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All
work upto plinth level :..With 40mm nominal size graded stone aggregate..M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate...."
30116335.1.1 "Providing and laying in position specified grade of reinforced cement concrete (nominal / design mix with 20mm nominal size graded stone aggregate) excluding the cost of centering,shuttering, finishing and reinforcement -All work up to plinth level :..M-20 Grade Concrete"
30116895.16.1 "Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detalingIS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3.Couplers shall be conforming to IS code on "Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification")..Mild steel and Medium Tensile steel bars. .."
30116945.16.6"Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detalingIS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3.Couplers shall be conforming to IS code on "Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification")..Thermo-Mechanically Treated bars.FE 500 D or more conforming to IS 1786.."
30116425.9.1 "Centering and shuttering in cluding strutting, propping etc. and removal of form for:..Foundations, footings, bases of columns, etc. for concrete upto plinth level"
30116565.9.6 "Centering and shuttering in cluding strutting, propping etc. and removal of form for:..Columns, P i l l a rs , Piers, Abutments, Posts and Struts."
30116435.9.2.1 "Centering and shuttering in cluding strutting, propping etc. and removal of form for:..Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc...Uptoplinthlevel"
30116355.2.1 "Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and upto floor two level excluding cost of centering, shuttering, finishing and reinforcement:..M-20 Grade Concrete"
30115854.2.1.3 "Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto floor two level, excluding the cost of centering, shuttering and finishing :..With 20mm nominal size graded stone aggregate..M-15 - Grade concrete."
30116715.9.16 "Centering and shuttering in cluding strutting, propping etc. and removal of form for:..Small lintels not exceeding 1.5m clear span, mouldingas incornices, window, sills, courses, bands, copings, bed plates, anchor blocks and the like.."
300014540 NSORBrickwork in plinth & foundation of Boundary wall with fly ash lime bricks (FALG bricks) having 75 Kg per sq cm average compressive strength conforming to IS:12894-2002, in cement mortar 1:6 , including cost of all material, labour, T&P, taxes, transportation ,curing etc. complete as per direction of Engineer in charge.
30117836.7.2.2 "Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor two level in :..Having 75 kg / cm2 average compressive strength...Cement mortar 1:6 (1 cement : 6 sand).."
301301813.2.2 "15 mm cement plaster on the rough side of single or half brick wall of mix..1:6 (1 cement : 6 sand) "
301250510.1Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
301302013.3.2 "20 mm cement plaster of mix :..1:6 (1 cement : 6 sand)"
301309213.53Finishing walls by any mechanical or manual means with Premium Acrylic Smooth exterior paint (Premium exterior) of required shade including all scaffolding. New work (Two or more coat applied @1.67ltr/10sqm over and including one coat undiluted exterior waterproofing coating @ 2.39 litre/10 sqm with crack bridging ability of upto 0.5mm on horizontal surfaces with an elongation of 150% and water proofing of upto 3 bars on vertical surface)
301257810.36Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer.in charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately).
300015045 NSORP&F Barbed wire (9.38 Kg per 100 M min.) to MS Angle Iron posts including screwing with GI tying wire staples or steel pins I/c cost of wire, staples pins etc. as per the direction of Engineer-In- Charge
301254710.22.2 "Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required...In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works."
30115764.1.1.3 "Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level :.With 20mm nominal size graded stone aggregate..M-15 - Grade concrete"
300014641 NSORProviding & Fixing 100 mm dia AC/PVC pipe with grating for weep holes in Brick masonary/ Plain/Reinforement cement concrete abutments , wing walls, retaining walls etc. extending through the full width of abutments , wing walls, retaining walls etc.with a slope of 1H: 20V including cost of all material, labour, T&P etc. complete as directed by Engineer in charge.
30115372.27.2 "Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete...Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming andcompacting (minimum compaction 95% of MDD) in layers not exceeding 15cm depth and dressing complete."
301274811.72.1 "Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc. of required colour strength, thickness pattern, surface texture (smooth/rough) and size/shape, conforming to 15658- 2006 made by table vibratory method using PU mould, laid in required colour and pattern over 50mm thick compacted bed of sand, compacting and proper embedding/ laying of inter locking paver blocks into the bedding layer through vibratory compaction byusing plate vibrator, filling the joints with sand and cutting of paver blocks as per required sizeand pattern, finishing and sweeping extra sand including locking with M15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturer's specifications and direction of Engineer-in-Charge...80 mm thick C.C. paver block of M-35 grade."
30120719.43.1 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
300014239a NSOR"Providing and laying in position Reinforced Cement Concrete NP 3 class / prestressed concrete hume pipe for culverts on first class bedding of granular material in single or double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling , concrete & masonary works in headwalls , parapets, , abutments, etc. but including cost of pipes, collars, cement mortar for jointing , placing in position, labour, transportation, etc complete as per direction of Engineer-in-charge..(b) Pipe Diameter 600mm"
301348917.3.1 "Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fittings and C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required :..W.C. pan with ISI marked white solid plastic seat and lid."
301349617.6.4 "Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including p
ainting of fittings and brackets, cutting and making good the walls and floors wherever required :..Range of four urinal basins with 10 litre white P.V.C. automatic flushing.cistern.."
301351517.11.9 "Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :..White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI marked..."
301414118.33Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards andweighing not less than 690 gm, 15 mm nominal bore
301414218.34Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore
301420018.67Providing and fixing in position best Indian Health Faucet with 8mm dia 1.2 meter long Flexible Tube and wall bracket with N. R. V. (non-return wall).
30151482.1.1.2.2 "Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid steel conduit ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit including painting, screwless connector for joints etc. as required as per specification for :-..Light point/fan points...Primary medium point..Using modular accessories"
30123529.173.1 "Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid door/window/ceosetory windows and other frames/chowkhat comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (woodpowder/ rice .husk/wheat husk) and non toxic additives (maximum toxicity indexof 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed S.S. screws having minimum density of 750 kg/m3 and screw withdrawal strength of 2200 N (Face) & 900 N (Edge), minimum compressive strength 58 N/mm2 , modulus of elasticity 900 N/ mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S. hold fast/lugs/S.S.dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/lugs or S.S. dash fasteners shall be paid separately)...Single or double rebate (125 mm X 65mm)"
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.30 MB
Document352.pdf
Tender Documents • 1.47 MB
Questionnaire.pdf
Other Document • 0.02 MB
BOQ_542567.xls
BOQ • 0.43 MB
AffidavitNew.pdf
Additional Documents • 0.18 MB
Download all tender documents and submit your bid