Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 CrAccepted-Finance | ₹4.0 Cr | L1 | Accepted-Finance As per system generated comparative statement |
| 2 | L2₹4.1 CrAccepted-Finance | ₹4.1 Cr | L2 | Accepted-Finance As per system generated comparative statement |
Tender Value
Refer Docs
EMD Value
₹4.2 L
Closing Date
10 Mar 2025, 12:20 pmClosed
Executive Engineer, Sangram division, PWD
O/o EE, Sangram division, PWD, Sangram, Kurung Kumey District, A.P.
C/o Circuit House at Sangram, Kurung Kumey District
2025_PWDAP_2174_1
SGMD/DRG-2/2024-25/991-92
Open Tender
Civil Works - Building
Item Rate
730 days
Sangram, Kurung Kumey District, A.P.
Tender Fee and EMD
4 documents required · 4 mandatory
₹2,000
EE PWD Sangram Division
₹4.2 L
Yes
11 Mar 2025
3 Mar 2025
10 Mar 2025
3 Mar 2025
10 Mar 2025
3 Mar 2025
3 Mar 2025 - 10 Mar 2025
Amount
SH1:- Site Development
Excavation in Soil with Dozer with lead upto 100 metres ( Excavation for road way in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 metres (average lead 50 metres), including trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections.)
Excavation in Ordinary Rock with Dozer with lead upto 100 metres (Excavation for roadway in ordinary rock by deploying a dozer, 80 HP including cutting and pushing the cut earth to site of embankment upto a distance of 100 metres ( average lead 50 metres ), trimming bottom and side slopes in accordance with the requirements of lines, grades and cross sections.)
SH2:-Circuit House
SH: i: EARTHWORK Earthwork in excavation in foundation and trenches etc. in all kinds of soil(excluding soil containing 50% or more of shingle or small size boulders upto 30cm size, lift upto 1.50 m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Re-filling of excavated earth in foundation and plinth etc in 15cm layer including ramming and watering etc complete
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
SH :ii - Cement Concrete Work Providing and laying in foundations and plinth cement concrete 1 : 4: 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering Concrete in Rectangular bed (PCC bed) of footing
Providing and laying cement concrete 1:2:4 excluding the cost of centering and shuttering in foundation and plinth In Foundation and Plinth
SH:iii - Damp proof course Providing and laying damp proof course 50mm thick with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 stone aggregate 20mm nominal size )
Applying a coat of hot bitumen ( mashphalte 80/100 or equivalent ) using 1.70 kg per Sq.m on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil .
SH :iv- RCC WORKS Reinforced concrete work in foundation, footings, bases of column etc and mass concrete excluding cost of centering, shuttering and reinforcement in a) M 20 (1 cement: 1.5 coarse sand : 3 stone aggregate) 20mm nominal size
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface. Ground floor
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface.
Reinforced cement concrete in suspended floors, roofs , landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1:3 (1 cement : 3 sand ) of thickness not exceeding 6mm to give a smooth and even surface but excluding the cost of centering and shuttering and reinforcemnt with M 20 and 20mm nominal size
Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete.
b) Column Pillars Struts. Column from footing to Ground Floor
c) Lintels, beams, girders, bressumers and cantilevers etc.
d) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
e) Stairs (excluding landings) except spiral stair cases.
Reinforcement of RCC work including bending, binding and placing in position complete. a) Mild Steel
SH:v- BRICKWORK Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand).
Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth.
SH:vi -WOODEN WORK Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws. a) 38 mm thick best available local wood, class - B I
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. a) Ornamental Grill.
FITTING FOR DOORS Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal
Providing and fixing aluminium butt hinges anodised ,transparent or dyed to required color or shade with necessary screws etc complete
Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. (a) 100mm
Providing and fixing MS Hooks and Eyes. (a) 150 mm.
Providing and fixing MS door latch with necessary screws etc complete
Providing and fixing aluminium Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete
SH :vii- FINISHING 20 mm cement plaster 1:3(1 cement:: 3 sand )
Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade.
Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade.
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
SH : viii: Railing work providing and fixing stainless steel railing made of hollow tubes ,channels, plates etc including welding,grinding,bufffing,polishing and making curvature and fitting the same with necessary stainless steel nuts and bolts complete ,i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc of required size ,on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer in charge
SH:IX - Iron Railing work providing and fixing hand rail of approved size by welding etc to steel ladder railing ,balcony railing ,staircase railing and similar works, including applying priming coat of approved steel primer
SH-X : Flooring providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.06 % and conforming to IS:15622, of approved make, in all colours and shades ,laid on 20mm thick cement mortar 1:4 ,including grouting the joints with white cement and matching pigments etc, complete
SH :XI- Drainage Construction of cement concrete drain 30 cm wide and 30cm deep in cement concrete 1 : 3 :6 (1 cement : 3 sand : 6 hard graded stone chips or aggrigate 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete.
SH: -XII- water supply Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 20mm nominal bore.
b)40mm nominal bore
Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). b) 40mm nominal bore
Providing and fixing brass bib cock of approved quality. a) 15mm nominal bore.
Providing and fixing brass stop cock of approved quality. a) 20 mm nominal bore
Providing and fixing PVC connection pipe with brass union 30cm length. a) 15 mm nominal bore
b) 25 mm nominal bore
SH :XIII- Sanitary installation Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvan a) Long Pan patten WC Pan
Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers.
Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. b) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality.
Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.
Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design.
Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement : 5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 :4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg), cement concrete 1 : 4 : 8.
SH 3: SEPTIC TANK
Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) 1 : 1.5 : 3 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
Reinforcement of RCC work including bending, binding and placing in position complete. a)Mild Steel.
Centring and shuttering including strutting, propping etc. and removal of form work for: a) Suspended floors, roofs, landing shelve and theirsupports, balconies and chajjas (3.50m height)
b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
12 mm thick cement plaster 1:3( 1 cement : 3 fine sand)
Neat cement punning
Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. a) 40 mm thick.
SH 4:FIRE HYDRANT INSTALLATION
Constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:5(1 cement : 5 fine sand) for fire hydrants with C.I surface box 350x350cm top and 165mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1 : 5 : 10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1 :3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design. With common burnt F.P.S (non-modular) bricks of class designation 7.5
Providing and fixing C.I sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separetely) 100 mm diametre Class- II
Providing and fixing G.I pipes complete with G.I fittings including trenching and refilling etc. (external) 50 mm dia Nominal bore
Providing and fixing G.I pipes complete with G.I fittings including trenching and refilling etc. Internal work exposed on wall 32 mm dia Nominal bore
Providing and fixing of Fire Extinguisher
Ms YARKUM AGENCY (BID ID -6547)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].