Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC C O AKBAR FURNITURE HOUSE MALHAR MORH GARHI UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹16.0 L+₹4.1 L (34.4%)Rejected-Finance | L2 | Rejected-Finance Not being L1 bidder | |
| 3 | L3₹16.0 L+₹4.2 L (35.1%)Rejected-Finance | L3 | Rejected-Finance Not being L1 bidder | |
| 4 | L4₹24.6 L+₹12.8 L (107.4%)Rejected-Finance NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance Not being L1 bidder | |
| 5 | L5₹28.5 L+₹16.6 L (139.9%)Rejected-Finance | L5 | Rejected-Finance Not being L1 bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
1 Aug 2023, 6:00 pmClosed
GARRISON ENGINEER SOUTH UDHAMPUR
GE SOUTH UDHAMPUR
CA NO GE S U 34 2023 24 REPAIR TO BOUNDARY WALL, DRAIN, PATH CLEANING OF SEWAGE LINE AND OTHER MISC WORK IN MD ACCN AT BIKRAM ENCLAVE UNDER AGE BR II, GE SOUTH UDHAMPUR
2023_MES_606757_1
GE/S(U)-34/2023-24
Open Tender
Civil Works
Works
330 days
GE SOUTH UDHAMPUR
As per NIT
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹70,000
17 Oct 2023
30 Jun 2023
2 Aug 2023
30 Jun 2023
1 Aug 2023
14 Jul 2023
Amount
Desluding/Dewatering of septictank/ soakage wells/drain including intel/outlet chambers removing out all scum, siltresiduals sludge (both) organic/ inorganic nature) after plugging the incomming sewage lines through combined high pressure water jetting cum suction (vaccum) type machine mounted on LCV/HCV facility of high pressure vaccum and removing the same in the tank to a place outside MOD load meant for the purpose by local municipality complete all as specified and as directed.
Removal of blockage and cleaning of sewage lines of 100 mm bore by roding from manholes to manholes or manholes to cleaning eyes, taking out all debris, sludges and solid materials from sewage lines and removing out side MOD land not less than 1000 metres and well flushing with water complete all as specified and as directed.
All as per ser item No 2 above but 150 mm bore complete all as specified and as directed.
All as per ser item No 2 but 200 mm bore complete all as specified and as directed.
Cleaning of cast iron pipes 100mm/75mm bore pipes by roddimg with jute bags and well flushing after cleaning complete all as specified and as directed.
Cleaning of man holes n.exc 1.5m deep and removing sludge/waste material to distance n.exc 500m and burying in pits and refilling the same complete all as specified and as directed.
All as per Item No 6 above but exceeding 1.5m deep and 3.0m deep complete all as specified and as directed.
Cleaning of floor traps and removing waste material etc to a distance not exceeding 50 m and burring in pits and re-filling the same complete all as specified and as directed.
Removal of blockage/waste and cleaning gully traps and Nahani traps of any description and size and waste material etc to a distance not exceeding 50 m and burrying in pits and re-filling the same complete all as specified and as directed.
Cleaning of blocked WC any type and removing waste material etc to a distance not exceeding 50m and burring in pits and re-filling the same complete all as specified and as directed.
Cleaning of shurbs/ bushes around septic tank, filter bed,manholes and along the sewage line etc complete all as specified and as directed.
Excavation in trenches n exc 1.5m wide and n exc 1.5 m deep and getting out in any type of soil complete all as specified and as directed.
Returning filling in including spreading levelling watering and well ramming in layers n exc 25cm thickness complete all as specified and as directed.
Removing excavated soil to a distance n exc 50m and depositing at a level n exc 1.5m above the starting point complete all as specified and as directed.
Demolition of cement concrete in ground floor and pavings nexc 15 cm thick below or above ground level complete all as specified and as directed.
PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as mass concrete and filling of foundation complete all as specified and as directed.
Demolition and breaking up drain pipes 100 mm dia (Salt glazed ware, AC or reinforced concrete), set in cement mortar complete all as specified and as directed.
Demolition and breaking up drain pipes 150 mm dia (Salt glazed ware, AC or reinforced concrete), set in cement mortar complete all as specified and as directed.
Demolition and breaking up drain pipes 200 mm dia (Salt glazed ware, AC or reinforced concrete), set in cement mortar complete all as specified and as directed.
Salt glazed stone ware drain pipe 100mm bore in trenches and jointed complete all as specified and as directed.
Salt glazed stone ware drain pipe 150mm bore in trenches and jointed complete all as specified and as directed.
Salt glazed stone ware drain pipe 200mm bore in trenches and jointed complete all as specified and as directed.
Cement Concrete 1:4:8 type C2 using 40mm graded crushed stone aggregateas in bed to 100mm drain pies incl packing under and haunching against the sides pipes after they are laid and tested for complete all as specified and as directed.
Cement Concrete 1:4:8 type D2 using 40mm graded crushed stone aggregate as in bed to 150mm drain pies incl packing under and haunching against the sides pipes after they are laid and tested for complete all as specified and as directed.
Cement Concrete 1:4:8 type D2 using 40mm graded crushed stone aggregate as in bed to 200mm drain pies incl packing under and haunching against the sides pipes after they are laid and tested for complete all as specified and as directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc complete all as specified and as directed.
Brick work with sub class 'B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed.
Walling of random rubble masonary , rectangular coursed, well bonded, bedded and solidly hearted, built in CM (1:6) complete all as specified and as directed.
Taking down cement plaster on brick or stone masonry wall etc incl racking out joints haking for key, scrubbing down with water etc as in external surfaces of man holes, septic tank, filter bed etc incl removing of debrics complete all as specified and as directed.
Rendering 15mm thick on brick or concrete surfaces of walls in CM (1:4) including finishing the surfaces even and smooth without using extra cement as in manholes, septic tank, filter bed out let drain etc complete all as specified and as directed.
Flush pointing to Square rubble masonry coursed or uncoursed in CM (1:3) complete all as specified and as directed.
PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregates as in coping ,benching and the like including form work complete all as specified and as directed.
Demolation of reinforced cement concrete not exeeding 15 CM thickness (below or above ground level) complete all as specified and as directed.
Reinforced cement concrete type B-1 (using 20mm graded crushed stone aggregate work as in slabs supported on walls , beams etc complete all as specified and as directed.
RCC 1:2:4 type B1 using 20mm graded crushed stone aggregates for precast cement concrete slabs as in manhole covers etc set in cement mortar 1:4 complete all as specified and as directed.
Form work to soffits of suspended slabs and similar work not exceeding 200mm thick complete all as specified and as directed.
Mild Steel TMT bars 10MM dia and over cut to length bent to shape required, including cranking ,bending spirally for hooping columns hooking ends and binding with mild steel wire annealed not less than 0.9 mm dia complete all as specified and as directed.
Cutting in to existing manholes for forming new drains and making good to pipe and making good to pipe and rendering ,cutting out existing benching in cement concrete 1:2:4 type B1(in 1/2 or 3/4 round in section) and re-forming benching as required for 150mm bore pipe complete all as specified and as directed.
PVC (SWR) junction double,(Single T), equal or unequal 110 mm dia complete all as specified and as directed.
PVC (SWR) junction double,(double T), equal or unequal 110 mm dia with access door complete all as specified and as directed.
PVC (SWR) vent cowl 110 mm dia complete all as specified and as directed.
CI floor trap with grating including jointing to waste pipe with dia of outlet 75mm in repair complete all as specified and as directed.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required of internal dia of pipe 50/75/100 mm complete all as specified and as directed.
Sand cast cast iron soil, waste and vent pipes in any length with or without ears, with cement joints fixed to walls bore of pipe 100mm dia complete all as specified and as directed.
Sand cast cast iron soil, waste and vent pipes in any length with or without ears, with cement joints fixed to walls bore of pipe 75mm dia complete all as specified and as directed.
CI bends diminishing pieces or tapers bore of pipe 100mm complete all as specified and as directed.
CI bends diminishing pieces or tapers bore of pipe 75mm complete all as specified and as directed.
CI branch pieces, single (equal or unequal) ordinary or inverted (size or socket type) or with parallel branches with oval access door bore of pipe 100mm complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
300mm x 200mm x 7 mm thick coloured glazed ceramic tiles as in skirting/dado set and jointed in neat cement slurry and pointed in coloured cement to match the surface complete all as specified and as directed.
Rendering 10 mm thick on fair faces of brick /concrete surfaces in cement mortar 1:4 and finished even and fair complete all as specified and as directed.
Non skid coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and as directed.
Screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and as directed.
Plain cement concrete 1:2:4 type B1( using 20mm graded crushed stone aggregate) 100mm thick as in floor, complete all as specified and as directed.
Chequered cement concrete (glossy finish) tiles 300 mm x 300 mm x 25 mm thick set jointed and pointed in neat cement slurry in floor with grey cement and pigment and including 20 mm thick screed bed cement mortar 1:6 complete all as specified and as directed.
Screed bed or bedding layer of mortar 20mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed.
Machine pressed precast concrete interlocking paver block (glossy finish)of approved shape and size confirming to IS 15658-2006 of 60 mm thickness with grey cement and no pigment, M-35 Grade of approved colour and design complete all as specified and as directed.
75 mm thick plain cement concrete 1:4:8 type D-2 (40 mm graded crushed stone aggregates) as in sub base complete all as specified and as directed.
Sand cushioning 20 to 30mm thick for fixing of inter locking tiles complete all as specified and as directed.
10 ltr capacity PVC low level flushing cistern symphonic action type white with inlet valve float and handle including brackets, fixed in repairs complete all as specified and as directed.
Flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level cistern complete all as specified and as directed.
Vitreous China squatting pan, 'Orissa' pattern, size 580x 440 mm white, with integral foot rests including a provision of concrete bedding but fixed in repair complete all as specified and as directed.
Cast iron 'P' or 'S' trap for bore of pipe 100mm complete all as specified and as directed.
PCC 1: 5:10 type E-2 using 40 mm graded brick aggregate as in filling under sunken floors etc complete all as specified and as directed.
Note :- (a) Contractors/Contractor representative/ Engineer will report to Bikram complaint cell/ concern JE daily in morning 09:00 AM to collect complaints for routine/urgent works related to day to day maintenance till completion of contract. (b) All routine/urgent jobs received on docket slip shall be attended within 24hrs, if contractor not complete the complaints then he will be charged penalty of Rs 450 per complaint per day.
khajuria builders
sohtra and co
SINGH CONST CO
M/S PARDEEP KUMAR
VIRINDER SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .