Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.4 LAccepted-AOC H NO 21666 POWER HOUSE ROAD STREET NO 9 BATHINDA PB 151001 | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹47.9 L+₹1.5 L (3.24%)Rejected-Finance 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | L2 | Rejected-Finance Other than Lower Bidder | |
| 3 | L3₹47.7 L+₹1.3 L (2.81%)Rejected-Finance | L3 | Rejected-Finance Other than Lower Bidder |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
4 Apr 2022, 6:00 pmClosed
GE Kapurthala
GE Kapurthala
Repair/Replacement and Maintenance of external LT Network and allied works and water lines all type of pump sets and other allied works at Mil Stn Beas and Jandiala Guru under GE Kapurthala
2022_MES_512704_1
GE KPT-88/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Kapurthala
Please refer Tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Kaputhala
₹90,000
Yes
17 May 2022
9 Mar 2022
6 Apr 2022
9 Mar 2022
4 Apr 2022
16 Mar 2022
Amount
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for taking out and laying CI/GI pipe complete all as specified and directed by Engineer-in-Charge.
Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer complete all as specified and directed by Engineer-in-Charge.
Removal of surplus spoil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge.
Taking down GI pipe 20 mm bore medium grade and fitting and supply and fixing GI tubing medium grade 20 mm bore in any length with all fitting laid in trench and connecting up with water supply main complete all as specified and directed (Excavation and earthwork shall be measured and paid for separetely under approprite item)
All as per item ser No 4 above here in before but 25 mm bore
All as per item ser No 4 above here in before but 40 mm bore
All as per item ser No 4 above here in before but 50 mm bore
All as per item ser No 4 above here in before but 80 mm bore
Taking down old unserviceable GI/CI pipe 80 mm bore and supply, laying, jointing and testing new cast iron pipe 80 mm bore centrifugally cast class LA confirming to IS - 1536 spigot and socketed ends in any length laid in trenches complete all as specified and directed. (Note : excavation, earth work, CI fitting and new run lead joint shall be measured and paid for separetely under appropriate item of Sch 'A')
All as per item No 9 above here in before but 100 mm bore
All as per item No 9 above here in before but DI (K-7)100 mm bore
All as per item No 9 above here in before but 150 mm bore
All as per item No 9 above here in before but DI (K-7) 150 mm bore
M & L for disconnecting electric connection and pipe connection and taking out submersible pump & motor of capacity 12.5 to 17.5 HP from bore well and taking to workshop for repair and removal of burnt winding wire from motor and rewinding with new PVC insulated copper winding wire for submersible motor of same guage and weight to existing including replacement of , Motor bush, thrust plate coupling complete with key and alignment of motor stater's slote reassembnling the motor with pump and lowering it into bore well making it functional and testing complete all as specified.
All as per item 14 above here in before but capacity 25 to 30 HP
All as per item 14 above here in before but capacity 35 to 40 HP of turbine motor pump including replacerment of ball bearings.
All as per item 14 above here in before but capacity 100 HP of turbine motor pump including replacerment of ball bearings.
M & L for disconnecting submersible pump from electric motor and taking it to work shop for repair / replacment of unserviceable part of submersible pump capacity 12.5 to 17.5 HP such as gun metal bush impeller assembly remetaling/turning to shaft, locking key and MS nuts & bolts of existing size and reassembling the pump with motor and making it functional all as specified.
All as per item No 18 here in before but for submersible pump for capacity 25 HP to 30 HP.
All as per item No 18 here in before but for submersible pump for capacity 35 HP to 40 HP.
All as per item No 18 here in before but for submersible pump for capacity 100 HP.
Supply & Fixing Submersible pump set, Electric driven having dischage 1000 LPM at 84 mtr head including suitable capacity of electric motor not less than 30 HP suitable for operation of 415 volts 50 C/S AC supply Make: Crompton /KSB /kirlosker.
Supply & Fixing PVC insulated submersible cable 03 core 1100 Volt AC Supply stranded copper conductor of size 10 sqmm in replacement of old U/S cable Make : Rallison / Plaza/Fenolax.
Supply & Fixing PVC insulated submersible cable 03 core 1100 Volt AC Supply stranded copper conductor of size 16 sqmm in replacement of old U/S cable Make : Rallison / Plaza/Fenolax.
Supply and fix in replacment of gun metal globe or gate valve with iron wheel head screwed both ends suitable for galvanised pipe 20 mm bore complete all as specified.
All as per item ser No 25 above here in before but 25 mm bore
All as per item ser No 25 above here in before but 40 mm bore
All as per item ser No 25 above here in before but 50 mm bore
S&F GI coloumn pipe 100mm dia heavy duty 'C' class with flanged ends drill 3 meter including joining to exising main pipe line comlete al as specified and directed (the cost of nuts bolts washers packing materials and pressure gauge shall be deemed to include in unit rate quoted by the contracror.
Supply and fixing in replacement of old unserviceable water level indicator cum auto motor shutdown devies electronic type including PVC copper cable 2.5 Sqmm with GI steel for hanging and water level censor 04-05 Nos with copper PVC cable as required as per site complete all as specified Mke : SECO/L&T/CG/Photon/Hotron
Supply and fixing in replacement cast iron fitting such as bends, tapers, (any type, radius and angle) tapers any type,(straight, bend, increasing, decreasing or double socket etc.)Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs tee pieces, single branch for spigot and socket and flanged pipe up to 150 mm bore complete all as specified and directed.
Supply and fixing in replacement cast pipe 150 mm bore centrifugally cast class 'A' flanged both end in any length complete all as specified and directed.
Supply and fixing in replacement cast pipe 100 mm bore centrifugally cast class 'A' flanged both end in any length complete all as specified and directed.
M&L for lead joint suitable for CI pipe 80 mm bore complete for laying of new pipe line including rectification of leakage pipe line on daily complaint basis all as specified and directed.
M&L for lead joint suitable for CI pipe 100 mm bore complete for laying of new pipe line including rectification of leakage pipe line on daily complaint basis all as specified and directed.
M&L for lead joint suitable for CI pipe 150 mm bore complete for laying of new pipe line including rectification of leakage pipe line on daily complaint basis all as specified and directed.
Supply and fixing in replacment cast iron sluice valve 80 mm bore with flanged ends, ISI mark with Gun metal spindle, CI gate with brass ring and iron wheel handle with jointing material such as nuts /bolts washers and rubber insertion sheet etc including taking out old U/S sluice valve complete all as specified
All as per srl item No 37 here in before but 100 mm dia.
All as per ser item No 37 above here in before but 150 mm bore
M &L for earth work in trenches / pit and bailing out water to rectfying leaking joint of CI pipe spigot and socket type 80 mm bore including pouring extra lead chieseling and levelling the excavated material after rectifying the leakage complete all as specified.
All as per item ser No 40 above here in before but 100 mm bore
All as per item ser No 40 above here in before but 150 mm bore
Supply and fixing in replacment cast iron Non Return Valve 80 mm bore with flanged ends, ISI mark with jointing material such as nuts /bolts washers and rubber insertion sheet etc including taking out old U/S Non Return Valve complete all as specified.
All as per item ser No 43 above here in before but 100 mm bore
M & L for replacment existing cast iron double air release valve of size 80 mm bore replacment of worn out bolts, nuts gaskets if any complete all as specified and directed.
S& F in replacement unserviceable fully automatic star delta starter with all accessories in sheet steel enclosuer type , 3 phase 440 volt 50 Hz suitable for capacity 25 HP motor complete. Make : L&T/SIEMEN/Havells
S& F in replacement unserviceable fully automatic star delta starter with all accessories in sheet steel enclosuer type , 3 phase 440 volt 50 Hz suitable for capacity 35 HP motor complete. Make : L&T/SIEMEN/Havells
Repair to existing valve pits of internal dimensions 90cm x 90 cm x 90 cm making good disturbed/dismantled brick work in cement mortar (1:4) plastering surfaces in CM 1:6, 15mm thick and PCC coping in cement concrete 1:2:4 type B-1 and providing MS cover in replacement made out of MS sheet 3 mm thick duly welded to MS angle iron frame 35x35x5mm including frame work as per existing size with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.(a) M&L for brick work using sub class 'B' (old size bricks) in CM 1:4 (b) M&L for rendering 15 mm thick in CM 1:4 finishing even and fair (c) M&L for PCC 1:2:4 type B-0 (using cum 12.5 mm graded stone aggregate ) as in coping (d) M&L for any type of mild steel work such as frame sheet 3 mm thick including welding (e) M&L for painting two coats of synthetic enamel paint over a coat of red oxide primer to untreated steel surface & prep of surface.
All as per ser item No 48 above here in before but size 75 x 75 x 75 cms
Material & labour for cleaning & flushing of RCC over head reservoir of capacity 25000 gallons at 60 feet staging removing of silt and sludge etc deposited inside the tank and cleaning of entire internal surfaces of tank with bleaching powder incl flushing with water, writing the capacity of tank and date of cleaning with black and white paint complete all as specified and as directed by Engr-in-Charge.
All as per item ser No 50 here in before but reservoir of capacity 4000 gln at 14 ft staging.
S&F phase sequancer corrector with phase loss corrector system working on 415 Volt, 50 Hz, On/Off coil (switch) current capacity 18A, working voltage 12/24 Volt, Cut of voltage (Low) 330-370 (Adjustable), cut of voltage (High) 440-540 Voltage (Adjustable), Phase reversal System, Single phasing protection system, Time delay to start system 150 sec and Off switching time (two stop the system) for 10 HP submersible pump etc complete all as specified and directed.Make :- VOLT-ON/Supreme Power Tac/Runcon
All as per item No 52 here in before but current Capacity 32A,25HP
All as per item No 52 here in before but current Capacity 40A 30HP
All as per item No 52 here in before but cuurent Capacity 52A 40HP
Takeing down old u/s bleching dozing pump along with all accessories and Supply and install connecing. Testing and commissioning of High Pressuure single Head adjustable "AQUAFIT" Dosing system Model No VST 1005 and VST 1006 of the following specification. Adjustble High Pressure 5 Kg/Sq. cm. power input 230V, 50 Hz, 40 SPM 1/30 fractional Horsepower, Max output 10 Ltr with mandatory accessories like lead Tubing, connecting ferrules, check valves, etc (A) Preparation tank Model No VST 1005 of net capacity 100 Ltr, FRP dosing tank dia 650 x net Height 375 + conical 300. Gross height with stand 1000 mm consisting of : (i) Water inlet line (ii) Outlet with stainer (iii) Drain (iv) overflow (v) conical bottom for sludge depositing (vi) Pot hole with cover (vii) level gauge (viii) Agitator 120 watt 900 RPM single phase flange mounted motor with plastic shaft and impeller. (B) Service Tank Model No VST 1006 dia 480 x height 575 net capacity 100 Ltr consisting of (i) water inlet line (ii) Dosing pump inlet arrangement (iii) Drain (iv) Overflow (v) Level Gauge (vi) inspection port (vii) Agitator 120 watt 900 RPM Single Phase flange mounted moto with plastic shaft and impeller (ix) provision of mounting Pump on Lid/wall Make : VARIMA of equivalent CG.
Attending complaints by deploying sufficient labour (Skilled and helpers) for repair to leakage/blockage of wall/underground water carrying CI/DI pipes of sizes ,80mm to 150 mm bore of any description at any location including necessary excavation & earth work, cutting existing pipe lines, dewatering etc complete all as specified. NOTE:- (i) Complaint shall be notified to contractor on telephone, therefore it is mandatory for the contractor to mention his ‘Mobile Number’ while quoting the tender. (ii) Complaint shall be notified to contractor at any time between 0600 hrs to 2000 hrs and the same shall be immediately attended and defects rectified within six hrs from notification of complaint to the contractor. (iii) Confirmation of attendance & rectification of complaint shall be given in writing by the contractor and same shall be recorded in the ‘Register’ maintained for the purpose. The ‘Register’ shall be produced to this office along with RAR/Final Bill. (iv) In case the contractor fails to attend complaints within stipulated time (i.e. 6 hrs), a penalty shall be imposed @ Rs 300/- per complaint. (iv) Rates quoted by the contractor shall be deemed included the cost of necessary T& P required. (v) CI/DI Pipes, Fittings and cost of jointing shall be measured and paid separately under respective items.
Attending complaints by deploying sufficient labour (Skilled and helpers) for repair to leakage/blockage of wall/underground water carrying GI pipes of sizes ,20mm to 50 mm bore of any description at any location including necessary excavation & earth work, cutting existing pipe lines, dewatering etc complete all as specified. NOTE:- (i) Complaint shall be notified to contractor on telephone, therefore it is mandatory for the contractor to mention his ‘Mobile Number’ while quoting the tender. (ii) Complaint shall be notified to contractor at any time between 0600 hrs to 2000 hrs and the same shall be immediately attended and defects rectified within six hrs from notification of complaint to the contractor. (iii) Confirmation of attendance & rectification of complaint shall be given in writing by the contractor and same shall be recorded in the ‘Register’ maintained for the purpose. The ‘Register’ shall be produced to this office along with RAR/Final Bill. (iv) In case the contractor fails to attend complaints within stipulated time (i.e. 6 hrs), a penalty shall be imposed @ Rs 300/- per complaint. (iv) Rates quoted by the contractor shall be deemed included the cost of necessary fittings and T& P required. (v) GI Pipes shall be measured and paid separately under respective items.
Supply& Fixing bettery 12 volts 180AH Make Exide/Lumminus.
M&L for replacement on load change over rotery type 4 pole 415 volt 200 AmpMake :Standard/L&T/Indoasian
Supply only orthotolidine reagenet for chlorine test in 500 ml bottle of make - glaxo / SDS / Ran baxy
Supply and fixing in replacement of MCCB, 4 pole, 415 volt of cpacity. Adjustable type 400 Amp, short circuit breaking capacity 35/36 KA, thermal setting 70-100% confirming to IS, including thimbles, nuts, bolts, washers etc disconnecting from LT panel and making incoming, out going connections complete all as specified and directed. (Cost of copper thimbles, nut & bolts shall be included in the quoted rate) Make : HAVELLS/C&S/Legrand/L&T
-do- but capacity 300 to 350 Amps and breaking capacity 35/36 KA
Supply and fixing in replacement of MCCB, 4 pole, 415 volt of cpacity 200 Amp, short circuit breaking capacity 35/36 KA, thermal magnatic protection type confirming to IS, including thimbles, nuts, bolts, washers etc disconnecting from LT panel and making incoming, out going connections complete all as specified and directed. (Cost of copper thimbles, nut & bolts shall be included in the quoted rate) Make : HAVELLS/C&S/Legrand/L&T
-do- but capacity 160 Amps and breaking capacity 35/36 KA
-do- but capacity 250 Amps and breaking capacity 35/36 KA
Note for Item No 64 to 66 : Contractor will provide MCCBs as per site requirement/design of LT Panel (as per Make,model, type of existing MCCBs) for proper housing of MCCBs in existing LT Panels)
S&F aviation light LED type fixed on the top of OHT of any height including necessary fixing accessories complete all as specified and directed.
Material labour and services for taking sample water in sterlised bottles from various borewells for Analysis of water for the following parameters and obtaining sample test report from Govt Recognized Laboratories: (i) Physio Chemical Analysis of Water ( Colour , odour , pH Total solids, Dissolved Solids, Permanent hardness, temporary Hardness, Ammonia feree and salinbe, Ammonia Albuminoidal, Nitrites, Nitreates, Oxygen absorption at 15 Min, Iron , Fluoride) (ii) Microbiological Analysis ( Totral Choliforms , Eschirrchea Coli) Note : 1. A certificate of approval / certification of Lab by Goivt Of India / State Govt shall be submitted by the contractor to the deptt. 2. Sample shall be submitted to the Labortory within 24 Hrs of collection of sample
Supply of Chlorine test kit with coloured ample complete with all testing fitments and OT solution in Rexene finish Box Make - RMCO
Disconnect the electrical connection and water pipe connection of motor pump and taking out the motor pump from bore well and column pipe of 3 mtr long -10 nos with required T &P for carrying out the following works :-
Developing the borewell for six hours with air compressor machine of capacity 250 PSI and 550 Cfm till clear water is obtain from the borewell and all the blocked stainers are opened upto depth of 300 feet complete all as specified and directed by Engijneer in Charge .
Lowering of submersible pump set with column pipe of 80/100 mm dia 3 mtr long -10 Nos with required T & P and man power.
Supply and filling pea gravel of size 3 to 10 mm to a packed thickness into the side of existing bore well (which is hollow space between casing pipe and true bore ) all as directed by Engr-in-charge complete all as specified and directed.
S&F Ammeter,square type,0-200amps.Make:-AE/HPL.
--do-- but 0-100 amps.
--do-- but 0-60 amps.
S&F volt meter,square type ,0-500 volts. Make:-AE/HPL.
Supply only gland packing of size 10 mm to 16mm.
M&L for replacment of pressure gauge 0-100 PSI, dial type fixed on pumping line in various pumps all as specified.
Relaying of disconnected CI/DI pipe 80 to 150 mm bore dismantled including transporting to the new location as directed not more than 500 mtr distance, complete all as directed of the 350 mm sizes (Note: Jointing, fittings & earth work will be measured and paid separately)
Supply and fixing MS clamp of size 50x6 mm, MS flat iron with one No GI/MS socket of 20mm/15mm duly welded incl nut & bolts for taking branch connection/jointing of branch connection from 40 to 150mm bore line including boring in GI/CI pipe incl rubber packing all as directed.
M&L for painting of CI/GI pipe 80 mm to 150mm dia laid in open surface/wall with 2 coat of super enamelled black paint after cleaning, brushing the existing surface of pipe at Pump houses in various location of Beas and Jandiala all as specified and directed by Engr in Charge
M & L for brick protection using old size sub class 'B' bricks, laid flat dry but adjoining to each other laid lengh wise perpendicular to the axis of cable complete all as specified and directed.
Supplying, filling in trenches spreading, leveling sand cushioning 8 cm below and 15 cm above the cable for under ground cable complete all as specified & directed.
Supply laying, commissioning and testing XLPE insulated armoured heavy duty, electric cable with aluminium stranded conductor for working 1100 Voltage grade size 2 core, 16sqmm including taking out existing unserviceable cable complete all as specified and directed (Earth work, sand cushioning and brick protection shall be measured and paid for separetaly).
All as per item ser No 86 above here in before but 25 sqmm 4 Core
All as per item ser No 86 above here in before but 35 sqmm 3.5 Core
All as per item ser No 86 above here in before but size 3.5 core 70 sq mm
All as per item ser No 86 above here in before but size 3.5 core 95 sq mm
Note for Ser Item No 86 to 90 : Contractor will deposit old retrievd unsv XLPE LT Cable to MES Store Yard and will be taken on ledger charge as salvage.
Supply and layng in replacement GI pipe light grade 50 mm bore for cable porotection fixed to poles/along wall/floor/under road/preparation of GI bracket etc across the drain or nallah with clamps. Bolts, nuts & washers etc complete all as specified including taking down the old unsv (clamps. Bolts, nuts & washers shall be measured and paid seperatly)
-do-- but of 80 mm dia
Supply and erect in truly vertical position pretressed concrete pole 9.0 mtr long 102mm x 172mm at top and 102 mm x 279mm at bottom, class 10 including painting of pole upto 1.5 mtr height from coping of pole with synthetic enamelled paint black & White strips each of 30 cm height complete all as specified and directed including taking out the old unservicebale one.(Excavation, earth work, PCC shall be measured & paid seperatly)
Supply and Fixing in replacement, shackle type porcelain vitrous white, green or brown insulators for working pressure 1100 volts grade 90 mm dia x 75 mm height including galvanised MS straps, washers, insulator bolts, washers & nuts complete all as specified and directed.complete all as specified.
Supply & fixing in replacement pin type porcelain, vitrous white, brown insulator including one galvanised MS spindle and two galvanised iron washers and one galvanised MS nut, 100 mm height 65 mm dia for 1100 volt grade complete all as specified and directed.
Supply & fabricating and fixing in replacement cross arms (any type) supports bracing, stiffeners anticlimbing spikes etc made out of MS, MS channel, angle iron, flat of any size including drilling of holes, making of clamps, nut, bolts etc including painting with two coat of aluminium paint over a coat of red oxide primer after preperation of surface to all steel and iron surfaces complete all as specified and as directed by Engr-in-charge.
M & L in replacement earthing complete with GI or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically in a pit not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below level covered on all sides with alternative layers of charcol dust and common salt 15 cm thick connected to galvanised earth lead Galvanised Iron strip 32 x 6 cm by means of bolts, nuts, check nuts and washers of Galvanised Iron or steel with protection pipe earth wire protected by galvanized steel pipe light grade 40 mm bore from top of the earth plate electrode upto test point and watering pipe 20mm bore, GI light grade with funnel and wire mesh all as shawn in electrical plate No 3 of SSR Part-1 and connected to earthing test point all as specified or indiated and testing on completion, including PCC earth pit (1:3:6) type C-2 RCC covered with CI cover hinged with frame including excavation and earth work complete all as specified.
Supply and fix in replacement cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 25 to 50 sq mm indoor/outdoor type all as specified and directed by Engr in Charge.
-do- but for cable of size 70 to 95mSqmm
-do- but for cable of size 120 to 150 Sq mm
-do- but for cable of size 185 to 240 Sq mm
-do- but for cable of size 300 to 400 Sq mm
M & L for unbinding from insulators the ACSR conductor on pole and restretching the loose ACSR conductor of any size on LT poles and binding the same with 2 mm dia new alumunium binding wire complete all as specified and directed.
Labour only for cutting/pruning of tree branches 1.5 mtr all around the LT overhead lines of span n.exc 40 mtr and around the pole obstruction the overhead line & removing the branches to distance n.exc 50 mtr to be the entire satisfaction of Engineer-in-charge,
Labour only by providing a trained electrician with helper for servicing, repair/maint, replcement of unservicable components like changeover, MCCBs, Volt meter, Ammeter etc , cutting/drilling/welding wk etc ,replacement of copper/alumn bus bar , thimbles, changing of connection copper wire lead etc all as specified and directed by Engr in Charge. (The above job also includes replacement of following component in existing LT Panel Boards including disconnecting and taking down the UNSV components at different locations all as specified and directed by Engr in Charge :- (Items used will be measured and paid separately as mentioned below (a) to (k)
(a) Aluminium thimbles or lugs 35 sqmm
(b) Aluminium thimbles or lugs 50 sqmm
(c) Aluminium thimbles or lugs 70 sqmm
(d) Aluminium thimbles or lugs 95 sqmm
(e) Aluminium thimbles or lugs120 sqmm
(f) Voltmeter Digital type ,0-500 Volts
(g) Ammeter Digital type of 400 amps capacity
M&L for cleaning and preparation of old painted surface of HT/LT PCC pole 9/ 11 mtr long and painting with one coat of marking 30 cm high alternate black & white strips with synthetic enameled paint up to 1.5 mtr height and writing pole Nos and applying one coat of cement base paint on PCC coping complete all as specified and directed by Engr in Charge
M&L for preparation of old painted steel pole of 9 m long and painting with two coats of aluminium paint from top of the pole to 1.5 m above the bottom of the pole and painting with two coats of black bituminous paint over a coat of red oxide zinc chrome primer upto 1.5m from bottom of the pole complete all as specified and directed
Taking down existing old unsv LT panel and supply, fabricating, installation, commissioning, testing and electrically connected CPRI approved manufacturer LT panel out door cubical type, Double door, made of 3.15 mm thick CRCA sheet steel on angle iron frame 50mm x 50mm x 6 mm of size not less than 1.5m x1.5 m x.0.50 m with removable hinged doors on both side, locking arrangement, vermin proof, painted with 2 coats of synthetic enamel paint over a coat of red oxide (internal& external surface) with heat shrinkable sleeves on Copper bus bar 600 Amp capacity - 04 Nos for distribution, complete wiring with thimbles and other accessories using crimping tool including foundation for fixing over PCC (1:2:4) type B-1 using 20mm graded stone aggregate foundation complete all as specified and directed by Engr in Charge comprising the following :- Incoming:- (i) MCCB 4 pole, 415 volts Adjustable type,400 Amps ,36KA, , 50 C/S with spreader link - 01 Nos Make : Schneider/L&T/Legrand. Outgoing:- (i) MCCB 4 pole, 415 volts Adjustable type,250 Amps ,36KA, , 50 C/S with spreader link - 02 Nos Make : Schneider/L&T/Legrand. (i) MCCB 4 pole, 415 volts Adjustable type,200 Amps ,36KA, , 50 C/S with spreader link - 04 Nos Make : Schneider/L&T/Legrand. (i) MCCB 4 pole, 415 volts Adjustable type,100 Amps ,36KA, , 50 C/S with spreader link - 02 Nos Make : Schneider/L&T/Legrand. (iii) Indicating lamps, LED type, 230VAC - 3Nos. (iv) Digital Voltmeter , 3Phase -01 Nos (v) Digital Ammeter 3Phase - 1 Nos. (vi) CT coils - 3 Nos.
Taking down existing old unsv LT panel and supply, fabricating, installation, commissioning, testing and electrically connected CPRI approved manufacturer LT panel out door cubical type, Double door, made of 3.15 mm thick CRCA sheet steel on angle iron frame 50mm x 50mm x 6 mm of size not less than 1.5m x1.5 m x.0.50 m with removable hinged doors on both side, locking arrangement, vermin proof, painted with 2 coats of synthetic enamel paint over a coat of red oxide (internal& external surface) with heat shrinkable sleeves on Copper bus bar 600 Amp capacity - 04 Nos for distribution, complete wiring with thimbles and other accessories using crimping tool including foundation for fixing over PCC (1:2:4) type B-1 using 20mm graded stone aggregate foundation complete all as specified and directed by Engr in Charge comprising the following :- Incoming:- (i) MCCB 4 pole, 415 volts Adjustable type,400 Amps ,36KA, , 50 C/S with spreader link - 01 Nos Make : Schneider/L&T/Legrand. Outgoing:- (i) MCCB 4 pole, 415 volts Adjustable type,200 Amps ,36KA, , 50 C/S with spreader link - 02 Nos Make : Schneider/L&T/Legrand. (i) MCCB 4 pole, 415 volts Adjustable type,100 Amps ,36KA, , 50 C/S with spreader link - 06 Nos Make : Schneider/L&T/Legrand. (iv) Indicating lamps, LED type, 230VAC - 3Nos. (v) Digital Voltmeter , 3Phase -01 Nos(vi) Digital Ammeter 3Phase - 1 Nos (vii) CT coils - 3 Nos.
Dismantling and taking down old existing ACSR conductor of any size/type from LT electric pole with the help of suitable T&P and proper safety gears to clear the disturbed area due to wind/storm complete all as specified and directed by Engr in Charge
M&L in replacement ACSR conductor of any size including binding on existing LT poles or new poles with 2 mm dia aluminium binding wire complete including dismantling/taking down of old unsv ACSR conductor all as specified and directed. (Squirrel/Weasel type ACSR to be used)
Dismantling and taking out/ down old existing broken/ deshaped LT PCC poles 9 mtr including insulators from site by means of JCB/ Hydra machine/Typhor or suitable T&P with proper safety arrangements, providing proper stay wires etc to avoid damage to others poles/span of ACSR including depositing/collecting the pole a side in a proper way complete all as specified and directed by Engr in Charge. (Items includes dismantling of 4/2 pole structure also)
M&L for repalcement of Stay assembly comprising of GI stay bow 14 mm dia, 40 cm long (over all) galvanized steel stay rod 20 mm dia, 215 cm long with threaded ends GI nuts, bolts, washers, stay plate 30cmx30cmx6mm complete all as specified and directed.
Supply & Replacement of stay wire standard of 7/4 mm of GI wire complete all as specified and directed by Engineer-in-Charge.
Supply & Replacement of loop type insulators, vitreous porcelain brown or green large size with over all dimension 90 x 140 mm clearance of hole 25.5 mm all as specified.
J.K & Company
DUGGAL CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .