Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.7 CrAccepted-AOC | ₹2.7 Cr | 1 | Accepted-AOC Lowest-1 |
| 2 | 2₹2.8 Cr+₹11.1 L (4.09%)Rejected-AOC | ₹2.8 Cr+₹11.1 L (4.09%) | 2 | Rejected-AOC Lowest-2 |
Tender Value
₹2.4 Cr
EMD Value
₹4.9 L
Closing Date
6 Apr 2022, 11:00 amClosed
Executive Engineer
Office Of PHED Fatehabad
Thuiyan under JJM 243.15 lakhs 18076 dt. 02/3/22 recalled 2nd
2022_HRY_211256_2
Thuiyan under JJM 243.15 lakhs 18076 dt. 02/3/22
Open Limited
Civil Works
Works
90 days
Thuiyan
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
Yes
₹4.9 L
Yes
18 Apr 2022
25 Mar 2022
6 Apr 2022
25 Mar 2022
6 Apr 2022
25 Mar 2022
Amount
N.S. Item
Supply & erection of Horizontal spindle split casing type pumping sets minimum Four (4) Star rating duties coupled to AC squrrel cage induction type motor with 1440 RPM, 3 phase 50 Hz and accessories as described in Schedule No.II complete in all respect with priming arrangement with complete base frame. A) Raw water pump set Raw Water Pump set 800 LPM 12 Mtrs Head
Raw Water Pump set 400 LPM 12 Mtrs Head (for lifting of Raw Water)
Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900 mm having following items. (A) For Raw Water Pump set 800 LPM 12 Mtrs Head 2 Nos. a) Main switch as required 2 No.(L&T Siemens, ABB) b) Volt meter 100x100 mm range 0 to 500 volt 1 No.(AE/KAPPA/L&T) C) Amp meter 100X100mm range 0 to 100 Amp 2 Nos. (AE/KAPPA/L&T) D) CT 100/ 3 Nos. (AE/KAPPA/L&T) E) VSS 1 No.& ASS 2 No. each of approved make F) SPP 2 No. of approved make g) Motor starter, Star delta 2 No.for 800 LPM 12 Mtr H) Capacity KVAR as per site requirement 2 No. I) Indicating Lamp - One Set J) Change Over switch as required = 1 No.
(B) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900 mm having following items. (For lifting of Raw Water) (A) For Raw Water Pump set 400 LPM 12 Mtrs Head 2 Nos. a) Main switch as required 2 No.(L&T Siemens, ABB) b) Volt meter 100x100 mm range 0 to 500 volt 1 No.(AE/KAPPA/L&T) C) Amp meter 100X100mm range 0 to 100 Amp 2 Nos. (AE/KAPPA/L&T) D) CT 100/ 3 Nos. (AE/KAPPA/L&T) E) VSS 1 No.& ASS 2 No. each of approved make F) SPP 2 No. of approved make g) Motor starter, Star delta 2 No.for 400 LPM 12 Mtr H) Capacity KVAR as per site requirement 2 No. I) Indicating Lamp - One Set J) Change Over switch as required = 1 No.
(C) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900 mm and 400 mm deep having following items. (B) For Clear Water Pump set 1600 LPM 40 Mtrs Head 2 Nos. a) Main switch as per required capacity 2 No.(L&T Siemens, ABB) b) Volt meter 100x100 mm range 0 to 500 volt 1 No.(AE/KAPPA/L&T) C) Amp meter 100X100mm range 0 to 100 Amp 2 Nos. (AE/KAPPA/L&T) D) CT 100/ 3 Nos. (AE/KAPPA/L&T) E) VSS 1 No.& ASS 2 No. each of approved make F) SPP 2 No. of approved make g) Motor starter, Star delta 2 No.for 1600 LPM 40 Mtr H) Capacity KVAR as per site requirement 2 No. I) Indicating Lamp - One Set J) Change Over switch as per required capacity = 1 No.
Supplying erection, testing of ISI marked copper wire for 6 Nos. motors with under ground system in PVC and flexible pipes copper wire size 6 sq. mm complete in all respects with accessories like thimble etc. complete in respects.
Supplying erection, testing of ISI marked copper wire for 6 Nos. motors with under ground system in PVC and flexible pipes copper wire size 10 sq. mm complete in all respects with accessories like thimble etc. complete in respects.
Supply erection testing of light fittings including wire in the pump chamber with materail upto 10 points including switch button plug PVC conduit pipe & copper wire etc.as per approved specifications complete in respect.
Providing & fixing of 16" dia Gate Valve of M.S Sheets including Cost of Channel & Other Material & Painting etc. Complete in all respect.
Supply erection testing of reputed make LED light 100 watts with fittings and accessories complete in respect.
Operation and maintenance for the complete scope of work mention in the DNIT (Disinfection material supplied by the PHED) as per schedule IV for a period of 5 years after 12 months during defect liability period 3 months trial run (Will be charged to the A/Mtc. estimate. Operation and Maintenance of during defect liability (Operation Only) Operation and Maintenance of during the 1st year defect liability period
Operation and Maintenance of during the 2nd year
Operation and Maintenance of during the 3rd year
Operation and Maintenance of during the 4th year
Operation and Maintenance of during the 5th year
Operation and Maintenance of during the 6th year
Credit of brick /brick bats Taking 30% bricks & 30% Brick bats & 20% Westage Bricks = 440 x 30/100 x 480
Less Credit for Bricks Bats = 440 x 30/100
Less Credit for old Machinary Raw Water = 2 x 900 LPM x 12 Mtr Head x 10 BHP
Less Credit for old Machinary Clear Water = 2 x 1600 LPM x 45 Mtr Head x 20 BHP
Bidder Name
Amount
ONKAR SINGH(GSTN-06CXXPS4617M1ZH)
VINOD KUMAR KHANNA(GSTN-NA)
VINOD KUMAR KHANNA
VINOD KUMAR KHANNA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .