Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹15,000
Closing Date
10 Jul 2020, 3:00 pmClosed
Project Director
DRDA, Ariyalur
Providing Alternative Borewell, Power Pump, Pump Room and Pipeline at Oriyur in Pungankuzhi Panchayat in Ariyalur Block of Ariyalur District under 80 Percent Capital Grant Fund 2017-18
2020_RDTN_169794_1
A4/1802/2020,Dated.24.06.2020
Open Tender
Civil Works - Water Works
Works
90 days
DRDA
As per Tender Document
4 documents required · 4 mandatory
₹0
₹15,000
3 Aug 2020
26 Jun 2020
10 Jul 2020
26 Jun 2020
10 Jul 2020
26 Jun 2020
Amount
Geo-physical survey charges including transportation of Geo-physical instrument and other accessories etc. complete.
Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site (Site will be shown by the Departmental Officers) including construction of mud pit.
Upto 60 m Depth ending below ground level
From 60 m upto 90 m Depth ending from ground level
From 90 m upto 120 m Depth ending from ground level
From 120 m upto 150 m Depth ending from ground level
Reaming 200 mm dia pilot bore to 350mm dia bore as directed by the Departmental Officer.
Upto 60 m depth ending below ground level
From 60 m depth and upto 90 mt depth ending below ground level
From 90 m upto 120 m depth ending below ground level
From 120 m upto 150 m depth ending below ground level
Supply and Delivery Conveyance of following PVC casing Pipes & Specials
200mm OD PVC Plain pipe
200mm OD PVC Ribbed Screen pipe
200mm OD PVC Threaded Dummy
Labour Charges for inserting 200mm dia (M.S. Casing pipes assembly with slots or with out slots) in the drilled hole including welding the joints etc., complete and supplying and packing the annular space with pebbles of size and quality as approved by the Departmental Officers
Charges for developing the Borewell with air compressor of 600 CFM capacity (Minimum 8 Hours) including transportation, labour and fuel charges for compressor as directed by Departmental Officers and conducting yield test by 'V' notch method.
Supply & Delivery and fixing of MS Borewell cover using MS flat of 10mmx3mm and MS Sheet 12 Gauge on top bolting arrangements securing the cap in position
Supply, Delivery of Submersible Pumpset suitable for Bore Well conforming to I.S.Specification for the following duty conditions 10HP X100 LPMX 250M three Phase
Supply, Delivery of Pannel Board with necessary fittingssuitable for Submersible Pumpset for the following duty conditions.For 10.00Hp
Supply, Delivery of the following size of the flat PVC 4core Copper conducted cable conforming to I.S.694/90 suitable for submersible pumpset 6.00 Sq.mm 3core flat copper cable
Supply & Delivery of G.I.Medium class pipes & specials as per relavant I.S.Specification
80mm G.I.Pipe
75 mm HDPE Pipe( PN10)
80 mm G.I.Elbow
80 mm Gate Valve
MS clamp set
Labour charges for erection of 10.00H.P.Submercible Pumpset in including fixing and jointing the cable with clamps, twin earthing trial run etc. complete
Earth work excavation and depositing on bank with in initial lead of 10 m and initial lift of 2m in hard stiff clay, stiff black cotton soil, hard red earth, earth mixed with small sized boulders and hard gravelly soil as per SS 20B for foundation
Pump Room
Supplying and Filling with good river sand including cost and conveyance to the site and all labour charges etc., complete
Pump Room
Cement concrete 1:4:8 mix using 40mm ISS HBG metal including cost and conveyance of all materials to site and all labour charges for mixing, laying and curing etc complete
Pump Room
Brick work in cement mortar 1:5 mix using country bricks of Size 83/4"x41/4"x21/4" and conveyance of all materials to site and all labour charges etc., complete
Pump Room
Supplying and erecting steel centering for sides and soffits etc complete complying with standard specifications (Below Ground level)
Pump Room
Supplying and erecting steel centering for sides and soffits etc complete complying with standard specifications (Below Ground level)
Pump Room
Supplying and fabrication of steel including cost and conveyance of steel to site and all labour charges for straightening, cutting to length, bending to shape and tying in position and forming grills for all R.C.C works
Pump Room
Reinforced cement concrete 1:1.5:3 mix using 20mm ISS metal including cost and conveyance of all materials to site and all labour charges for mixing, laying, and curing etc complete
Pump Room
Plastering with cement mortar 1:3 mix to 10 mm thick including cost and conveyance of all materials to site and all labour charges etc., complete
Pump Room
Plastering with cement mortar 1:5 mix to 12 mm thick including cost and conveyance of all materials to site and all labour charges etc., complete
Pump Room
Painting two coats of new plastered surface with best approved first quality of Emulsion paint of approved colour over the existing Priming coat etc., Complete complying with standard Specifications
Pump Room
Painting two coats over new iron works using ready mixed enamel paintincluding cost and conveyance of paint and all labour charges etc complete
Pump Room
Cost and Supply of Mild Steel Door of size 0.90x2.10m
Pump Room
Cost and Supply of RCC Jolley of Size 0.45x0.30m
Pump Room
Wiring with 2x2.5 sq.mm PVC unseathed SC aluminium cable of 650v grade in suitable PVC Rigid pipe on wall and ceiling with PVC accessories withT.W.Switch box inflush with wall covered with hylum sheet with pointing of suitable colour for open PVC light point. (SD No. 24, less cost of T.C.wire)
Pump Room
Supply and fixing of WT Bulk head fitting with guard for inflorescent lamp with guard and Tube light (SD NO.87)
Pump Room
Supply and fixing of 8way DB of 15A with DPK switch of 500v P&N on suitable angle iron frame work with turn-king box MS cable entry box with PWD Earthing (SD NO.141) - SWITCH BOX
Pump Room
Supply and run off 2 of 6sqmm polythene insulated sheated (heavy duty) SC Aluminium cable of 1100 v grade on bearer on service connection mains.(SD NO.60)
Pump Room
Supply and run off 2 of 6sq.mm polythene insulated sheated (heavy duty) SC Aluminiumm cable of 1100v grade insuitable 25mm G.I.Pipe suitable bend at both ends with necessary angle iron upright and end supports for mains.(SD NO 70) -G.I.SERVICE PIPE
Pump Room
Supply and fixing of 16"x12" TW meter board suitable for fixing of single phase watt hour meter with supply and fixing 1 no of 32A fuse unit copper earth plate with bolt and nut without watt hour meter. - METRE BOARD
Pump Room
Earth work excavation and depositing on sides with initial lead and lift in hard stiff clay, hard red earth and hard gravelly soil
Pipe line
Towards the supply of PVC pipes with specials including cost and conyence of all material etc. completed As per Shedule of Rate is Aproval
90 mmPVC Pipe for Pipe line
Provision for EB Deposit
Provision for Name Board
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
G.MURUGAN
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .