Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 LAccepted-AOC | ₹33.9 L Quoted ₹34.5 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹35.8 L+₹1.3 L (3.91%)Rejected-Finance 27 WESTERN STREET ROOM NO 307 KOLKATA 700012 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700012 | ₹35.8 L+₹1.3 L (3.91%) | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹36.7 L+₹2.2 L (6.50%)Rejected-Finance | ₹36.7 L+₹2.2 L (6.50%) | L3 | Rejected-Finance Not Being Lowest |
| 4 | L4₹37.6 L+₹3.1 L (9.12%)Rejected-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | ₹37.6 L+₹3.1 L (9.12%) | L4 | Rejected-Finance Not Being Lowest |
| 5 | L5₹38.0 L+₹3.5 L (10.3%)Rejected-Finance PASCHIM BHAGABANPORE DARUA CONTAI PURBA MEDINIPUR 721401 | PURBA MEDINIPUR | PURBA MEDINIPUR | WEST BENGAL | 721401 | ₹38.0 L+₹3.5 L (10.3%) | L5 | Rejected-Finance Not Being Lowest |
| Sl No | Description | Qty | Unit | KRISHNA ENTERPRISES L4 | chauhan syndicate L7 | ELECTRO COMMERCIAL CO L2 | RPL SYNDICATE CO L9 | Bansal And Co L3 | MS SHIVA DURGA ENTERPRISES L1 | J B NATH AND SON L6 | RANA ENTERPRISES L5 | DS ENTERPRISES L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/aluminum point wiring (Light fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators socket, light fittings etc removing materials for taking credit and making good disturbed surfaces of wall, floor, etc. | 850 | Per Point | 180 ₹1,53,000 | 155 ₹1,31,750 | 60 ₹51,000 Lowest | 175 ₹1,48,750 | 120 ₹1,02,000 | 150 ₹1,27,500 | 165 ₹1,40,250 | 122 ₹1,03,700 | 100 ₹85,000 |
| 2.00M&L for point wiring with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable 1.5 sqmm (Phase - R,Y,B, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting of switches, sockets, fan regulators complete including making good the wall surfaces with matching colour on wall for the following. Note : Including Cutting chases, pinning in making good for facings where required and pointing the cement mortar 1:3 to ends or edges of landings,steps,cills,sun shades, shelves,lintels etc and cutting chases for concealed conduit wiring etc and making good, cutting not exceeding 10cm grith complete all as specified and directed by Engr-In-Charge for the following. | ||||||||||||
| 2.01 | One light point controlled by one switch. | 150 | Per Point | 1,450 ₹2,17,500 | 1,200 ₹1,80,000 | 1,300 ₹1,95,000 | 1,300 ₹1,95,000 | 1,200 ₹1,80,000 | 992 ₹1,48,800 Lowest | 1,195 ₹1,79,250 | 1,250 ₹1,87,500 | 1,200 ₹1,80,000 |
| 2.02 | One fan point/Exhaust controlled by one switch. | 70 | Per Point | 1,450 ₹1,01,500 | 1,185 ₹82,950 | 1,300 ₹91,000 | 1,290 ₹90,300 | 1,200 ₹84,000 | 992 ₹69,440 Lowest | 1,195 ₹83,650 | 1,225 ₹85,750 | 1,200 ₹84,000 |
| 2.03 | One bell point controlled by one bell push. | 5 | Per Point | 1,300 ₹6,500 | 1,185 ₹5,925 | 1,225 ₹6,125 | 1,285 ₹6,425 | 1,175 ₹5,875 | 992 ₹4,960 Lowest | 1,200 ₹6,000 | 1,200 ₹6,000 | 1,200 ₹6,000 |
| 2.04 | One socket outlet 5/6 Amp controlled by one switch on the same board with other switches. | 100 | Per Point | 165 ₹16,500 | 200 ₹20,000 | 150 ₹15,000 | 200 ₹20,000 | 100 ₹10,000 Lowest | 284 ₹28,400 | 220 ₹22,000 | 120 ₹12,000 | 100 ₹10,000 Lowest |
| 2.05 | One socket outlet 5/6 Amp controlled by one switch on indepdendent board. | 50 | Per Point | 1,450 ₹72,500 | 1,250 ₹62,500 | 1,300 ₹65,000 | 1,290 ₹64,500 | 1,320 ₹66,000 | 1,070 ₹53,500 Lowest | 1,235 ₹61,750 | 1,400 ₹70,000 | 1,300 ₹65,000 |
| 2.06 | One light point controlled by two, two way switches. | 2 | Per Point | 2,400 ₹4,800 | 2,100 ₹4,200 | 1,825 ₹3,650 | 2,300 ₹4,600 | 1,900 ₹3,800 | 1,397 ₹2,794 Lowest | 2,000 ₹4,000 | 2,000 ₹4,000 | 2,000 ₹4,000 |
| 3.00 | All as per item No. 2 above but for 15/16 Amps switch socket out let point by using 4 Sqmm FRLSH grade, PVC insulated, stranded copper, conductor and 4 Sqmm FRLSH grade PVC insulated, stranded copper conductor as earth continuity conductor all as specified and directed by Engr-In-Charge.. | 50 | Per Point | 2,500 ₹1,25,000 | 2,200 ₹1,10,000 | 2,200 ₹1,10,000 | 2,385 ₹1,19,250 | 2,300 ₹1,15,000 | 1,835 ₹91,750 Lowest | 2,155 ₹1,07,750 | 2,000 ₹1,00,000 | 2,000 ₹1,00,000 |
| 4.00M&L for point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - R,Y,B, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including PVC casing-caping not less than 32x12 mm ISI marked ivory colour with all fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators complete all as specified and directed by Engr-In-Charge for the following. | ||||||||||||
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
5 Sept 2025, 6:00 pmClosed
Garrison Engineer
GE (I) R and D Chandipur, Post-Chandipur, PIN-756025
REPAIR REPLACEMENT OF POINT WIRING SUB MAIN WIRING PANELS AND DBS MCCBS MCBS LED LIGHT FITTINGS EARTHING REPAIR TO FANS AND ALLIED WORKS AT OTM BLDGS ITR TECHNICAL AREA UNDER AGE EM CHANDIPUR
2025_MES_724332_1
8198/A/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chandipur
As per tender document
9 documents required · 9 mandatory
₹500
GE (I) R and D Chandipur
₹70,000
Yes
15 Oct 2025
4 Aug 2025
6 Sept 2025
4 Aug 2025
5 Sept 2025
19 Aug 2025
Amount
Taking down carefully copper/aluminum point wiring (Light fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators socket, light fittings etc removing materials for taking credit and making good disturbed surfaces of wall, floor, etc.
M&L for point wiring with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable 1.5 sqmm (Phase - R,Y,B, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting of switches, sockets, fan regulators complete including making good the wall surfaces with matching colour on wall for the following. Note : Including Cutting chases, pinning in making good for facings where required and pointing the cement mortar 1:3 to ends or edges of landings,steps,cills,sun shades, shelves,lintels etc and cutting chases for concealed conduit wiring etc and making good, cutting not exceeding 10cm grith complete all as specified and directed by Engr-In-Charge for the following.
One light point controlled by one switch.
One fan point/Exhaust controlled by one switch.
One bell point controlled by one bell push.
One socket outlet 5/6 Amp controlled by one switch on the same board with other switches.
One socket outlet 5/6 Amp controlled by one switch on indepdendent board.
One light point controlled by two, two way switches.
All as per item No. 2 above but for 15/16 Amps switch socket out let point by using 4 Sqmm FRLSH grade, PVC insulated, stranded copper, conductor and 4 Sqmm FRLSH grade PVC insulated, stranded copper conductor as earth continuity conductor all as specified and directed by Engr-In-Charge..
M&L for point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - R,Y,B, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including PVC casing-caping not less than 32x12 mm ISI marked ivory colour with all fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators complete all as specified and directed by Engr-In-Charge for the following.
One light point controlled by one switch.
One fan point /Exhaust fan point controlled by one switch.
One socket outlet 5/6 amp controlled by one switch on the same board with other switches.
One socket outlet 5/6 amp controlled by one switch on indepdendent board.
One bell point controlled by one bell push.
One light point controlled by two, two way switches.
M&L for point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 4 sqmm (Phase - R,Y,B, Neutral - Black) and earth continuity conductor 4 sqmm (Green) drawn into and including PVC casing-caping not less than 32 x12 mm ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover complete for one 16 amp socket outlet controlled by one switch on independent board Cable complete all as specified and directed by Engr-In-Charge
S&F for repair/replacement including connection of switch piano flush button type single pole one way 5/6 amp complete all as specified and directed by Engr-In-Charge
S&F for repair/replacement including connection of switch piano flush button type, single pole one way 15/16 amp complete all as specified and directed by Engr-In-Charge
S&F for repair/replacement Including connection of switch piano flush button type, 5/6 amp, single pole, two way complete all as specified and directed by Engr-In-Charge
S&F for repair/replacement Including connection of bell push, flush type, 5/6 amp 240 volts complete all as specified and directed by Engr-In-Charge
S&F for repair/replacement Including connection of socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete all as specified and directed by Engr-In-Charge
S&F for repair/replacement Including connection of socket outlet 2 in 1, 2 & 3 pin, 5/6 amp, flush type complete all as specified and directed by Engr-In-Charge
S&F for repair/replacement Including connection of ceiling rose 3 plates polycarbonate body complete all as specified and directed by Engr-In-Charge
S&F for repair/replacement Including connection of hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete all as specified and directed by Engr-In-Charge
M&L Modular Point wiring with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable 1.5 sqmm,and earth continuity conductor 1.5 sqmm (Phase - Red,yellow,Blue, Neutral - Black, Earth - Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and all as including suitable Modular white plate with frame and Modular metal flush box, top cover of same make, switches,sockets,fan regulators complete all as specified and directed by Engr-In-Charge for the following
One light point controlled by one switch.
One fan point /Exhaust fan point controlled by one switch.
One socket outlet 6 amp controlled by one switch on the same board with other switches.
One socket outlet 6 amp controlled by one switch on indepdendent board.
One bell point controlled by one bell push.
M&L for Modular point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 4 sqmm (Phase - R,Y,B, Neutral - Black) and earth continuity conductor 4 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings suitable Modular white plate with frame and Modular metal flush box, top cover of same make, switches,sockets complete all as specified and directed by Engr-In-Charge.
S&F for repair/replacement Including connection of modular switch one way 6 amp 1 module complete all as specified and directed
S&F for repair/replacement Including connection of modular switch one way 16 amp 1 module complete all as specified and directed
S&F for repair/replacement Including connection of modular bell push, 6 amp, 1 module complete all as required at site or directed.
S&F for repair/replacement Including connection of door bell, AC, 240 volts, single pole complete all as specified and directed
S&F for repair/replacement Including connection of modular socket 6/16 - 2/3 pin combined 2 module complete all as specified and directed
S&F for repair/replacement Including connection of modular socket 6 amp 2/3 pin combined 2 module complete all as specified and directed
S&F for repair/replacement Including connection of modular hum free electronic step fan regulator, 100 watt 2 module complete all as specified and directed
Taking down Sub main /Sub circuit wiring of any type and size including conduit / casing capping / batten wiring complete all as specified and directed
M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, stranded, copper conductor cable of size 4 Sqmm to be drawn in and including PVC conduit 25mm dia. (Note: Three runs of 4 Sqmm copper wire shall be measured as one unit.)
All as per item No. 24 above here in before but 3 runs of 6 sqmm
All as per item No. 24 above, but using 4 runs of 6 Sqmm and two run of 6 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, copper wire to be drawn in and inclusing PVC conduit medium grade of size 32 mm dia complete all as specified and directed (Note : Four runs of 6 Sqmm copper wire with two run of 6 Sqmm copper wire shall be measured as one unit.)
All as per item No. 24 above, but using 4 runs of 10 Sqmm and two run of 10 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, copper wire complete all as specified and directed
Supply and fix in repair Vertical TPN MCCB DB 8 way with 200 Amps rated busbar, double door type including provision for fixing MCCB 4 pole 100 Amps, 25 KA complete including taking down old DB and making disturbed surafce good to match the existing surface complete all as specified and directed
S & F in repair MCB DB made of sheet steel phosphatised powder coated with bus bar, neutral link, earth bar and din rail, double door type, TPN 4 way 240v, fixed in wall including making good disturbed surfaces including taking down old unserviceable complete all as specified and directed
All as per in Item No. 29 here-in-before but of SPN 8 way,240Volts double door as in repair.
All as per in Item No.29 here-in-before but of SPN 12 way,240Volts double door as in repair.
S&F in repair MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 25 kA, 415 Volts, 100 Amps complete all as specified and directed
All as per item No. 32 above but of capacity 63 Amps, 4 Pole, 16 KA.
S&F in repair MCB, SPN 40-63 Amps, 'C' series,10 kA.
S&F in repair , MCB, TPN, 415 V, 50Hz, 10kA, 'C' series, 63 Amps
S&F in repair , MCB, TP, 415 V, 50Hz, 10kA, 'C' series, 25 to 63 Amps
S&F in repair MCB, SP, 6 to 32 Amps, 'C' Series, 10 kA,
Supply and fix in repair/replacement of LED batten fitting of 1 x 20W with polycarbonate housing and integrated electronic driver complete with wiring and fixing accessories complete all as specified and directed
Supply and fix repair/replacement of LED batten fitting of 1 x 10W with polycarbonate housing and integrated electronic driver complete with wiring and fixing accessories complete all as specified and directed
Supply & fix repair/replacement of LED luminaire 600 mm x 600mm 35/36 watt 220 volts AC recessed type with driver including connection up three core flexible copper conductor case of suitable size complete all as specified and directed.
Supply and fix repair/replacement of LED 20W Glass T8 tube (LGT8) with in built driver and efficacy of 100 lm/W. LED and fixing accessories complete all as specified and directed
S&F in repair Sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP of 20 Amps complete all as specified and directed
M&L Earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm buried directly in ground connected to galvanized earth lead strip of size 25 mm x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron including 40mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe light grade 20mm dia, charcoal or coke and common salt in alternative layers of 15 cm compacted thickness all around the electrode with concrete earth pit with PCC type C1 , 1:3:6 (using 20 mm graded stone aggregate), 50mm thick precast RCC type B1, (1:2:4)(using 20 mm graded stone aggregate) pit cover reinforced with 8mm dia deformed bar and suitable handle made of 10mm dia round bar including galvanised strip of size 25mm x 4mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a distance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No.3 of SSR Part-I, 2009 and all as directed including taking down old unserviceable one. (Note : GI strip upto 7.5 m length shall be deemed to include in the cost of above item.
M&L Earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm buried directly in ground connected to galvanized earth lead connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron including 40mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe light grade 20mm dia, charcoal or coke and common salt in alternative layers of 15 cm compacted thickness all around the electrode with concrete earth pit with PCC type C1 , 1:3:6 (using 20 mm graded stone aggregate), 50mm thick precast RCC type B1, (1:2:4)(using 20 mm graded stone aggregate) pit cover reinforced with 8mm dia deformed bar and suitable handle made of 10mm dia round bar including galvanised strip of size 25mm x 4mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a distance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No.3 of SSR Part-I, 2009 and all as directed including taking down old unserviceable one. (Note : GI strip upto 7.5 m length shall be deemed to include in the cost of above item.
Disconnecting electrically and dismantling of ceiling fans of any make capacity and type, washing thoroughly of bearing /bush, fan blades and body of fan by kerosene /petrol etc and greasing for smooth functioning. Replacement of worn out/defective unserviceable parts (where ever necessary), reassembling the same including provision of three core flexible copper wire 1.5m long, including one coat of synthetic enamel paint (first quality) with super glossy finish to fan body and blades refixing the same to its original position including testing complete all as directed by Engineer-in-Charge. (NOTE : Replacement of worn out/ defective/unserviceable parts, flexible copper wire and rewinding shall be measured and paid separately under relevant items of these schedule).
All as per item No. 45 here-in-before but for Exhaust fans of any size and make.
All as per item No. 45 here-in-before but for air circulator fans/wall mounting fans of any size and make.
M&L Rewinding the motor of AC ceiling fan of any make and size (1200/1400mm) with super enamelled copper wire of adequate size/gauge including all insulation materials, varnishing etc complete all as directed by Engineer-in-Charge.
All as per item No.48 here-in-before but for exhaust fans of 300/380mm sweep of any make.
All as per item No. 48 here-in-before but for air circulators/wall mounting fans of any make and size.
Supply only Ball bearing of suitable size for any type/make of ceiling fan
All as per item No. 51 here-in-before but for Exhaust fans of any type/size/make.
All as per item No. 51 here-in-before but for air circulators/ wall mounting fans of any type/size/make.
Supply only capacitor 220 volts, 2.5 mfd suitable for ceiling fan
Supply only capacitor 220 volts,4 mfd suitable for ceiling fan
S&F in repair Hanging clamp for ceiling fan of adequate size including rubber reel, nuts, bolts and washers etc complete including taking down old unserviceable one, all as directed by Engineer-in-Charge.
S&F in repair LED Bldg security light fitting 30 Watt with all accessories, (with extra driver) attractively styled high pressure die cast housing acting as a heat sink housing epoxy powder coated in dark graphite grey colour suitable for mounting bracket of 40mm bore GI pipe light grade complete with all accessories complete all as specified and directed
ELECTRO COMMERCIAL CO (BID ID -3406117)
Bansal And Co (BID ID -3406518)
KRISHNA ENTERPRISES (BID ID -3404754)
RANA ENTERPRISES (BID ID -3405589)
J B NATH AND SON (BID ID -3406576)
chauhan syndicate (BID ID -3405831)
DS ENTERPRISES (BID ID -3404531)
RPL SYNDICATE CO (BID ID -3406307)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .