Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹41.0 LAccepted-AOC HOUSE NO 105 PANTHEERMA VILLAI NEAR NELLIKKAVILLAI CSI CHURCH VELLAYAMBALAM VENCODE P O KANYAKUMARI DIST TAMIL NADU 629 171 | VENCODE | KANYAKUMARI | TAMIL NADU | 629171 | 1 | Accepted-AOC Being L1 with reasonable rates | |
| 2 | 2₹41.8 L+₹51,433.76 (1.25%)Rejected-Finance | 2 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 3 | 3₹45.3 L+₹4.1 L (9.82%)Rejected-AOC NO 3 JAMI JAM KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | 3 | Rejected-AOC Not accepted as not being L1 | |
| 4 | 4₹48.4 L+₹7.1 L (17.3%)Rejected-Finance | 4 | Rejected-Finance NOT BEING LOWEST TENDERER |
Tender Value
₹46.8 L
EMD Value
₹93,600
Closing Date
15 Mar 2024, 6:00 pmClosed
GE CHENNAI
GE CHENNAI FORT ST GEORGE CHENNAI-09
SPECIAL REPAIRS TO BLDG NO II, II/10, ADDN/ ALTN TO BLDG NO XVI AND PROVN OF HARD STANDING AT CERTAIN AREA UNDER GE CHENNAI
2024_MES_642690_1
8726
Open Tender
Civil Works
Item Rate
183 days
CHENNAI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE CHENNAI
₹93,600
Yes
10 Apr 2024
16 Feb 2024
22 Mar 2024
16 Feb 2024
15 Mar 2024
1 Mar 2024
Amount
Complete removal of existing roof treatment any type and demolition of cement concrete padding at roof slab n exc 15cm thickness all specified and directed by Engr-in-Charge
M&L for plain cement concrete in roof kerbs or mud stops, rounded or chamfered on edges as roof padding type B1, 1:2:4 (20mm graded aggregate) finished fair and even over concrete surface on roof top, and finished even and smooth complete all as specifie and directed.
M&L for 10mm thick cement plaster in CM 1:4 mixed with WPC @ 200 ml per bag, when the concrete is green including finished the surfaces smooth and even without using extra cement all as per manufacturer instructions all as specified and as directed. Note: Water proofing compound will be paid under measured seperately
M&L for 10mm thick cement plaster in CM 1:3 on walls including finished the surfaces smooth and even without using extra cement mixed with WPC @ 200 ml per bag, all as per manufacturer instructions all as specified and as directed. Note: Water proofing compound will be paid under measured seperately
Supply only Liquid water proofing compoud
Cleaning and preparation of newly plasteres roof surfaces and applying the water proofing treatment as under. (a) Applying 1st course of bituminious (oil based) primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed. (b) Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm. (c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap by forced / torch application as per manufactures instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane, (e) Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on roof surfaces complete all as specified and directed.
Cleaning and preparation of newly plastered wall surfaces and applying the water proofing treatment as under. (a) Applying 1st course of bituminious (oil based) primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed. (b) Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm. (c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap by forced / torch application as per manufactures instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane, (e) Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on wall surfaces complete all as specified and directed.
M&L providing plain cement concrete 1:2:4, type B1 (using 20 mm graded aggregate) as in cills, steps, bands, copings, bed plates , etc including necessary form work, all as specified and as directed
Cutting down vegetation growths like plants/ trees of girth n. exc 15cm from roof tops/ sides, external walls of bldgs, chajjas, wall juctions at junction of rain water/ CI waste water pipe junctions including removal of roots and taking out carefully possible quality of concrete in roofs embedded in walls/ slab surfaces making good affected locations and applying TUFALO chemical (herbal medicine or Glyphosate Herbicide/equivalent) to arrest further growth and making good the distrubed surfaces with PCC (1:2:4) type B-1 or CM 1:2 all as specified and directed by the Engr-in-Charge. Note : The unit rate quoted shall be deemed to include the cost of scaffoloding/ staging etc.,
M&L for PVC (SWR) pipes 110mm single socketed , in any length with rubber ring joints ,fixed to walls /floor complete including dismantling existing pipes of any description all as specified and directed.
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:3 on ceiling area in patches not exceeding 5.00 sqm, finished even and smooth without using extra cement all as specified and directed.
M&L Rendering 15mm thick in CM 1:6 on fair face of brick work suraces finished even and smooth without using extra cementall as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick work in two layers, first layer 10mm thick in CM 1:6 and second finishing coat 5mm thick in CM 1:4 mixed with water proofing compound as per manufacturers instructions and finished even and fair on external surfaces all as specified and as directed. Note: Water proofing compound will be paid under measured seperately
M&L for applying three coat of white wash as in ceiling incl preparation of newly plastered ceiling surfaces all as specified and as directed.
M&L for preparation of newly plastered wall surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed.
Material and labour for applying two or more coats of 100% premium acrylic mulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete including preparation of newly plastered surfaces of walls all as specified and as directed by the Engineer-in-Charge. Make : APEX of Asian or equivalent of shalimar / Nerolac/ Berger.
Forming square grooves in plaster n exc 12mm deep and n exc 15mm on face complete all as specified and directed.
Complete removal of existing treatment & Material and labour for applying two or more coats of 100% premium acrylic mulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete including preparation of old plastered surfaces of walls all as specified and as directed by the Engineer-in-Charge. Make : APEX of Asian or equivalent of shalimar / Nerolac/ Berger.
M & L for applying two coat of white wash as in ceiling incl preparation of old plastered surfaces all as specified and as directed.
M & L for complete removal of existing treatment on wall surfaces and washing, rubbing down and applying two coats of oil bound distemper oyer a coat of alkali resistant primer on old surfaces of wall all as specified and as directed.
M & L two coat of synthetic enamel paint on old steel surfaces including preparation of surfaces of any description , over 10cm width or girth not other wise described all as specified and as directed.
M & L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint.
Demolition of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets all as specified and as directed.
M & L for galvanised powder coated snap grid framework of size 605 x 605mm for false ceiling all as specified including vinyl laminated MPL gypsum panels ( GYPTECH) 9mm thick of size 60 x 60 cm fixing with stapples on snap grid by means of GI wires not less than 4mm dia hooks and raw plug etc centre of make. GYPTECH /ARMSTRONG or or its technocommercial equivalent makes as specified here in after as approved by GE
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as specified and as directed.
S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
S&F Pre-painted galvalumealuminum zinc coating GIbased Plain steel sheet0.50mm thick of anycolour having tensilestrength of 550 Mpa as in roof covering/cladding towall, fixed with selftapping screws all as specified and as directed.
Demolition of Stone slabs and tiles of anydescription or thickness in floors, aprons etc.laid bedded pointed in any mortar all as specified and as directed.
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing), removing unserviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.Brushing neat cement slurry with 3.0kg of cement per sq. metre
M&L screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in cm 1:6 complete all as specified and as directed
M&L 10mm thick Cement Mortar 1:4 for backing coat on walls complete all as specified and as directed .
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile complete all as specified and as directed.
M&L Glazed ceramic tiles in vertical surface 300x 200x 7 mm thick set andjointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed.
M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
All as per item no 36.00 above but in vertical surfaces.
M&L for 25 mm thick Cement concrete type B-1,1:2:4 (20mm gradedaggregate as in levelling coarse all as specified and as directed.
Material and labour for coloured Vitrified Ceramic tiles of grade B-I (a),10 mm thick (square/ rectangular) polished, light shade, area of each tile not exceeding 0.36 sqm, laid in floors of pattern as approved over and including 15 mm thick screed bed in Cement mortar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed.
Material and labour for coloured Vitrified ceramic tiles of grade B-I(a), 10mm thick of size matching to floor tile as approved by GE, fixed in vertical surfaces such as in skirting/dado set and jointed in neat cement slurry and pointed in white or coloured cement to match floor tile over a backing coat in Cement Mortar 1:3, 10mm thick on fair faces of brick or concrete surfaces all as specified and as directed by the Engineer-in-Charge.
M&L for glazed coloured ceramic Concept designer tiles of 7mm thick and area exceeding 0.11 sqm and not exceeding 0.18 Sqm as approved by GE, fixed in vertical surfaces such as in dado set and jointed in neat cement slurry and pointed in white or coloured cement to match floor tile over and including a backing coat in Cement Mortar 1:4, 10mm thick all as specified and directed.
Cutting chases, pinning inn brick /concrete. making good to facings where required and pointing in cement mortar 1:3 toends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed watertubing or concealed conduit wiring,etc., and making good, cutting , exc 10 cm but not exc 20 cm girth all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
Cutting holes into orthrough brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required superficial area exc 400 sq. cm but n exc 0.10 sq.m. all as specified and as directed.
Cutting holes into or through brick walls area n.exc 150 sqcm built in cement or lime mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required
Cutting holes into or through brick walls area exc 150 sqcm but n.exc 400 sqcm built in cement or lime mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required
M&L MS work in bands, straps, supports of stays, sunshade /chajja brackets, hook and spintle hinges clamps, hold fasts, guardbars, grills bolts etc and similar conforming to Fe-290, Gde E 165 all as specified and directed
M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates all as specified and as directed.
S&F for Plate girder or single stanchions,built up of one beam or channel section with flange plates, caps,bases. splices, angle brackets,cleats and other connectionsconfirming to Fe 410-W(Gde-E- 250)quality-B all as specified and as directed.
M&L for applying two coats of synthetic enamelled paint over a coat of red oxide on steel or iron surface based materials of any description , not other wise described over 10 cm width or girth including preparation of new surfaces.
M&L for applying evenly a tack coat of in dustrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces all as specified and as directed.
S&F 15mm dia bore Galvanised steel water tubing medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed to walls/ceilings or laid in floors etc., complete including taking up (or) down the existing GI pipe completely all as specified for following bore of pipes.
S&F for 15mm dia two way bib cock with flange, chromium plated as per cat No.8311, Make : Prayag or its techno commercial equivalent in Jaquar/ Parryware/ Prima
S&F in repairs 15mm dia chromium plated fancy type angle cock cast copper alloy screwed down high pressure fancy screwed both ends for pipe or for union
Cutting existing 15mm dia steel tubing for alterations or additions (Each cut measured) done in position without taking down complete all as specified and directed
Screwing existing 15mm dia steel tubing for alterations or additions (or lengthening screw on pipe to form connector) done in position without taking down complete all as specified and directed
S&F for health faucet (Hand shower) with 1metre flexible tube with wall hook, Chromium Plated as per Cat No BEA-87 Make : Prayag its technocommercial equivalent in Parryware/ Jaqura/ Prima all as specified and as directed by the Engineer-in-Charge.
Refixing of existing wash hand basin in to different position including removing and installation of new brackets.
S & F of Vitreous china wash down water closet (pedestal pattern ) white (excluding fixing bolts flushing cistern and flush pipe )complete all as specified and directed.
S&F of PVC low level flushing cistern 10 ltrs capacity with complete accessories, PVC flush pipe, PVC over flow pipe, etc...and connected to water closet as per manufactures instruction and as directed by the Engineer in charge including removal of existing cistern etc... all as specified and directed.
S&Fin repair plastic water closet seat cover, white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device of make fixed with CI brackets as per cat No.513, Make Prayag its technocommercial equivalent in Parryware/ Jaqura/ Prima. all as specified and directed.
S&F Vitreous china Wash Hand Basin, white, flat back of size 550x400mm excluding taps, waste, chain and plug and porcelain stopper out including brackets complete all as specified and directed.
S&F in PVC waste pipe for wash hand basin (size 31/32mm x 800mm length) Make : Prayag Cat No.327 or its technocommercial equivalent in Parryware/ Jaqura/ Prima all as speified and directed
S&F PVC (SWR) pipes 110mm single socketed , in any length with rubber ring joints ,fixed to walls complete all as specified and directed.
S&F PVC (SWR) bends with oval access door 110mm fixed in repairs complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm fixed in repairs complete all as specified and directed.
S&F PVC (SWR) juncton single (single T ) equal or un equal with access door110mm fixed in repairs complete all as specified and directed.
S&F 110 mm dia PVC (SWR) branch piece, double (double Y) equal or unequal complete all as specified and directed.
S&F PVC (SWR) pipes 110mm single socketed , in any length with rubber ring joints ,fixed to floors complete all as specified and directed.
S&F 110mm PVC (SWR) WC connector bent type complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil all as specified and directed.
M&L for PCC 1:4:8 type D-2 in foundations, filling and mass concrete complete all as specified and directed.
M&L for Brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
M&L plain cement concrete Type B-0, 1:2:4 (12.5 mm graded aggregte), 40 mm thick, laid in drain, finished even and smooth with out using extra cement complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard dense soil
Removing excavated material exc. 50m n.exc 1000m and depositing where directed at a level n exc. 1.5 m above the starting point
S&F 150 mm dia reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed.
Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate for 150mm dia bore pipes all as per SSR Part-I specifications, complete all as specified and directed.
Cutting into existing manholes for connecting new drains (internal dia of pipe 150mm), making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
Dismantling aluminium partions including doors of any description
S&F Sheet glass 5.5mm thick, tinted glass glazing with glazing clips in square exc 0.5 sq.m in each pane fixing to aluminium frame work , all as specified and as directed
S&F aluminium powder coated (Minimum thickness of powder coating 50 micron) frame for doors/windows/ventilator/partition, glassing clipswith one or more tracks including joining cleats fot fixing complete all as directed by Engr-in-Charge.
S & F in repairs 9mm thick Prelaminated Particle board interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with glazing clips and screws as in repair all as specified
S&F for fully glazed shutters made out of toughened glass 12 mm thick shutter suitable for opening n.exc 1.2m wide as approved by GE, drillig holes for fixing handles incl provision of stainless steel matt finish handle 400mm-02nos, suitable locking arrangements , center lock, stainless steel floor spring, patch fittings consist of bottom patch, top patch and top pivot with stainless steel fixing plate etc. complete incl taking down old unserviceable glass door all as dircted by Engr-in-charge. Note:- The unit rate quoted shall deemed to include all necessary builders hardware except door closure.
S&F of Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steelheavy duty and fixed including removing of old floor spring complete .
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out soft and loose soil complete alll as specified and as directed.
Hardcore of gauge n exc 63 mm , broken stone or boulders deposited, spread and levelled in layers n.exc. 15 cm thick, watered and rammed true to surface complete all as specified and as directed.
Plain cement concrete 75 mm thick, type E-2, 1:5:10 (40 mm graded aggregate)as in subbase complete all as specifed and as directed.
Sand filling under paver blocks including watering and consolidation all as specifed and as directed.
M & L for rubber mould machine pressed precast concrete interlocking paver block, any shape and size confirming to IS-15658-2006 of 60 mm thickness, M-35 grade with grey cement and no pigment all as specified and as directed.
Providing plain cement concrete 1:2:4, type B1 (using 20 mm graded aggregate) as in kerbs to pack paver block including necessary formwork all as specified and as directed.
Preperation of newly plastered wall surface and applying two coats of cement based paint complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring light, fan, socket or power complete with fittings such as switches, ceiling roses,regulators sockets etc and making good disturbed surfaces of walls, floors to match with the existing surface complete all as specified
Taking down carefully by unservicable fittings of different size and capacity complete and making good disturbed surfaces of walls, floors to match with the existing surface complete all as specified
M&L for point wiring of size 1.5 sqmm with PVC insulated unsheathed multistranded copper conductor cable of 1100V grade drawn through new non metallic rigid PVC conduit including accessories, concealed in wall/floor and fixed on ceiling/roof etc, including pressed steel terminal boxes concealed in walls for housing modular switchs,sockets, fan regulators etc., incl provn of 1.5 sqmm PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dolly complete for complete for :-
one light point controlled by one switch
one fan point controlled by one switch
one 3 pin socket outlet 5 amps on the same board controlled by one switch.
one 3 pin socket outlet 5 amps on independent board controlled by one switch.
As per above items No 96.00 for one socket outlet three pin 15 amps control by one switch independent board with cable 2.5 sqmm size complet all as specified and directed.
M&L for point wiring of size 1.5 sqmm (two run) with PVC insulated unsheathed multistranded copper conductor cable of 1100V grade drawn through non metallic rigid Existing PVC conduit , in wall/floor and fixed on ceiling/roof etc, including pressed steel terminal boxes concealed in walls for housing mocular switchs,sockets, fan regulators etc., incl provn of 1.5 sqmm PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dolly complete
one light point controlled by one switch
one fan point controlled by one switch
one 3 pin socket outlet 5 amps on the same board controlled by one switch.
one 3 pin socket outlet 5 amps on independent board controlled by one switch.
one bell/buzzer point controlled by one bell push
As per above items No 98.00 for one socket outlet three pin 15 amps control by one switch independent board with cable 2.5 sqmm size complet all as specified and directed.
S& F for modular cover plate with frame 2 module complete all as specified and directed by Engr-in-Charge
S& F for modular cover plate with frame 4 module complete all as specified and directed by Engr-in-Charge
S& F for modular cover plate with frame 6 module complete all as specified and directed by Engr-in-Charge
S&F modular switches suitable for type AC 240V, 6 amps 1 module complete all as specified and directed by Engr-in-Charge
S&F modular sockets suitable for type AC 240V, 6 amps 2 module complete all as specified and directed by Engr-in-Charge
S&F modular switches suitable for type AC 240V, 16 amps 1 module complete all as specified and directed by Engr-in-Charge
S&F modular power sockets suitable for type AC 240V, 16 amps 2 module complete all as specified and directed by Engr-in-Charge
S&F modular fan regulator suitable for type AC 240V, 2 module complete all as specified and directed by Engr-in-Charge
S&F modular bell switch suitable for type AC 240V, 16 amps complete all as specified and directed by Engr-in-Charge
S&F call bell of multi music type A/C 230 volts complete all as specified and directed by Engr-in Charge
S&F ceiling rose , polycarbonate, isolated body with 2 to 3 terminals complete all as specified and directed by Engr-in Charge
Taking down ceiling fan carring out repairs by rewinding of ceiling fan with enameled copper wire with suitable gauge and insulating meterial including varnishing with suitable class of insulating varnish ,painting with two coats of synthetic enamel paint and writing MES number , including replacement bushes/bolt and nuts etc and conneting with twin core flexible cord from ceiling rose and testing complete all as specified
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Five star rated with brushless direct current motor
S&F lamp holder insulated body with back plate for batten fittings/angle holder
S&F of LED bulb 9 w high sutable for lamp holder complete all as specified and as directed by the Engineer-in-Charge. Make : Havells Cat No. LED PLUS 9W B22 CDL 2STAR LAMP or its technocommercial equivalent makes as specified here in after as approved by GE
Supply and fix 20Watts LED light fitting, basic all purpose surface and wall mounted LED batten 20Watts with aluminium housing and integrated electronic driver including 20W LED tube - 1No on surfaces of wall or ceiling including taking down the old fitting complete all as specified and as directed by the Engineer-in-Charge Make : Havells Cat No. LUMILINEPLUSNEOBS20WLED865SPCSSIND or its technocommercial equivalent makes as specified here in after as approved by GE
Supply and fix 36 Watts 2X2 ceiling light Environment friendly, new generation, aesthatically, ultra modern designed Recess mounting luminaire with high brightness SMD LEDs as light source suitable for Armstrong/Grid ceiling including taking down the old fitting completeall as specified and as directed by the Engineer-in-Charge Make Havells Cat No. VENUSNEO2X2PLR36WLED865G2 or or its technocommercial equivalent makes as specified here in after as approved by GE
Taking down sub main wiring any type and any size complete after taking proper disconneting of electric supply properly and making good surface complete all as specifided and directed
S&F sub main wiring complete with two runs of 4 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metalic rigid PVC conduit pipe concealed in wall alongwith accessories fixed on walls/floors/ceiling with one run of 4 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed by Engr-in-Charge. Note:- Two runs of PVC insulated cable 4 sqmm + one run 4 sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
Taking down AC box any type and any size complete after taking proper disconneting of electric supply properly and making good surface complete all as specifided and directed
S&F for modular 25 Amp motor starter AC switch with two module with socket 25 Amp including indication both red and green complete all as directed Make Legrand cat No 673031 or its technocommercial equivalent makes as specified here in after as approved by GE
Kaadosh Real Estates Pvt Ltd
G.L.THIRUMALAI NAIDU AND COMPANY
SRI VISHAKHA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .