Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹82.6 LAccepted-AOC NEAR NATRAJ MANDIR NEW INDIA COLONY PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest and reasonable | |
| 2 | L2₹84.1 L+₹18,211.30 (0.22%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹1.0 Cr+₹18.0 L (21.5%)Rejected-Finance 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Other than Lowest | |
| 4 | Rejected-Technical 1ST FLOOR GURJEET MARKET DHANGU ROAD | - | Rejected-Technical Rejected for NO in WLR QE Sep 2023 HQ ADGNJ |
Tender Value
₹98 L
EMD Value
₹1.4 L
Closing Date
25 Nov 2023, 6:00 pmClosed
CWE (AF) Jammu
Headquarters, CWE (AF) Jammu Near Gurdwara Sahib and Mandir Airforce Station Satwari, Jammu Pin 180 003
SPECIAL REPAIR TO ATC AND ASSOCIATED BUILDINGS AT GE AIR FORCE STATION PATHANKOT
2023_MES_622015_1
CWEAFJ-20/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Pathankot
All as Per Tender Documents
9 documents required · 9 mandatory
₹1,000
GE (AF) Pathankot
₹1.4 L
Yes
16 Jan 2024
6 Oct 2023
28 Nov 2023
6 Oct 2023
25 Nov 2023
11 Nov 2023
Amount
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any motar complete all as specified and directed by Engr-in-Charge.
S&F Non-skid ceramic tiles 7 to 8mm thick (square / rectangular ) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thck screed bed in CM 1:4 complete all as specified and directed by Engr-in-Charge.
S&F coloured Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thck screed bed in CM 1:4 complete all as specified and directed by Engr-in-Charge.
S&F coloured Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in skirting, including 10 mm thck screed bed in CM 1:3 complete all as specified and directed by Engr-in-Charge.
S&F coloured Glazed ceramic tiles (Decorative pattern) in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick plaster in CM 1:4 complete all as specified and directed by Engr-in-Charge.
M&L for 15-20mm thick Granite(of any type) work (table rubbed and polished) in window cills / counter for WHB or steel sink after cutting as required size for WHB & Sink set in cement mortar (1:4) including pointing using marble dust with admixture of pigment to match with shade of granite including 20 mm thick screed bed in CM 1:4 complete all as specified and directed by Engr-in-Charge.
M&L for Machine cut kota stone slab flooring 20-25mm thick over 20 mm thick CM 1:3 bedding layer laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engr-in-Charge.
M&L for Kota stone 15 to 18 mm-ditto- but Skirting over 10 mm thick 1:3 screed bed complete all as specified and directed by Engr-in-Charge.
M&L for 20-25 mm thick Machine cut & double side polished Kota stone slab as in partetion and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and fixing in position after all necessary arrangements complete all as specified and directed by Engr-in-Charge.
Demolition of reinforced Concrete in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed by Engr-in-Charge.
M&L for Reinforced cement concrete (nominal mix) type B1 1:2:4 in chajjas complete all as specified and directed by Engr-in-Charge.
M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges on flat surface complete all as specified and directed.
Demolition of Brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engr-in-Charge.
Taking down Doors chowkat or frame n exc 1.5 Sqm but with shutters (without taking off shutters from the frames) and removing out of site complete all as specified and directed by Engr-in-Charge.
Taking down steel/wooden door chowkat or frames exc 1.5 Sqm but n exc 4 Sqm each. but with shutters (without taking off shutters from the frames)
Taking down steel/wooden window or ventilators with chowkat or frames exc 1.5 Sqm but n exc 4 Sqm each. but with shutters (without taking off shutters from the frames) complete all as specified and directed by Engr-in-Charge.
Taking down steel/wooden window or ventilators with chowkat or frames n.exc 1.5 Sqm each. but with shutters (without taking off shutters from the frames) complete all as specified and directed by Engr-in-Charge.
M&L preparation of old untreated Steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
M&L removing all previous treatment and preparation of old painted wooden surfaces of any description not otherwise described over 10 cm width or girth and applying wooden filler liquid transparent under two coats of varnish complete all as specified and directed.
Demolition of cement (un-reinforced) in any position not otherwise specifically provided complete all as specified and as directed
M&L 75 mm thick Cement concrete type C-2, 1:3:6 (40 mm graded aggregate) as in plinth protection complete all as specified and directed by Engr-in-Charge.
Forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade A complete all as specified and directed by Engr-in-Charge.
Taking down cement plaster on brick/stone or concrete surfaces including racking out joints, hacking for key,scrubbing down with water to receive plaster complete all as specified and directed by Engr-in-Charge. Note: The lead and lift as required including provision of standard steel scaffolding upto a height of 20m. shall deemed to have been included in the quoted rate and no extra shall be admitted at a laterdate in this respect.
Rendering 10 mm thick on fair faces of concrete surfaces as fin, facia upward or down ward of any height of ceiling , bottom of chhajja, roof projection etc in CM 1:3 with liquid water proofing @ 200 ml per 50 kg of cement finished even and smooth without using extra cement upto the height of 20 mtr complete all as specified & directed by Engr-in-Charge . Note: The lead and lift as required including provision of standard steel scaffolding upto a height of 20 M. shall deemed to have been included in the quoted rate and no extra shall be admitted at a laterdate in this respect complete all as specified and directed by Engr-in-Charge. Water proofing shall be measured and paid seprately
Supply only liquid water proofing compound complete all as specified and directed by Engr-in-Charge.
M&L for 10 mm thick in CM 1:6 on fair faces of brick or concrete complete all as specified and directed by Engr-in-Charge.
M&L for preparation of New plastered surfaces by washing, rubbing down and stopping of distempered surfaces and applying two coat of oil emulation distemper on wall surface over primer etc complete all as specified and directed by Engr-in-Charge.
Complete removal of existing treatment and Preparation of old painted wall surface and applying two coat of white wash complete all as specified and directed by Engr-in-Charge.
Complete Removal of existing treatment on wall and applying two coats of oil bond distemper over a coat of 3mm thick wall care putty on one coat of alkali resistant priming paint over wall or ceiling complete all as specified and directed by Engr-in-Charge.
Complete removal of existing treatment and Preparation of new ceiling surface and applying two coat of white wash complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new plastered ceiling surfaces and applying three coat of white wash on ceilingl surface over primer etc complete upto the height of 20 m including necessary scafolding and formwork complete all as specified and directed by Engr-in-Charge.
M&L for rendering 15 mm thick rendering in CM 1:4 on the surfaces of Brick/concrete in two layers 5 mm thick 1:4 over 10 mm thick 1:6 finishing fair and even without using extra cement with WPC @3% by the weight of cement WPC compound will be measured and paid saperatly complete all as specified and directed by Engr-in-Charge. Note: The lead and lift as required including provision of standard steel scaffolding upto a height of 20 M. shall deemed to have been included in the quoted rate and no extra shall be admitted at a laterdate in this respect .
Supply only Water proofing compound complete all as specified and directed by Engr-in-Charge.
M & L for preparation of new plastered or unplastered surfaces of walls any width or girth etc and applying two coats of exterior weather coat paint (apex Ultima) in any pattern over a coat of exterior wall care putty and a coat of primer complete all as specified and directed by Engr-in-Charge. Note: The lead and lift as required including provision of standard steel scaffolding upto a height of 20 M. shall deemed to have been included in the quoted rate and no extra shall be admitted at a laterdate in this respect.
M & L for Complete romoval of existing treatment on wall and priming plastered and other surface with alkali resistant and applying two coats of exterior emulsion paint over coat of exterior wall care putty complete all as specified and directed by Engr-in-Charge. Note : The lead and lift as required including provision of standard steel scaffolding upto a height of 20 M. shall deemed to have been included in the quoted rate and no extra shall be admitted at a laterdate in this respect
S&F in repairs SS Sinks kitchen or laboratory with plugs, washers and wastes; including beding in cement mortar on to dwarf walls, or including fixing cantilever brackets and connecting union to waste pipe; upto 0.5 sqm each after removing old U/S glazed fine clay sinks and fixing over granite plateform after cutting the granite complete all as specified and directed by Engr-in-Charge.
S&F in repairs PVC(SWR) pipe 110 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engr-in-Charge..
S&F in repairs PVC(SWR) pipe 75 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engr-in-Charge..
S&F in repairs PVC(SWR) bend any radius, 110 mm dia complete all as specified and directed by Engr-in-Charge..
S&F in repairs PVC(SWR) bend any radius, 75 mm dia complete all as specified and directed by Engr-in-Charge.
S&F in repairs 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent complete all as specified and directed by Engr-in-Charge..
S&F in repairs CP Pillar taps long body 15 mm dia, fancy type, chromium plated , screwed down high pressure ,with long screwed shanks and fly-nuts , screwed for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
S&F fancy type CP bib taps , 15 mm bore with crutch or , screwed down, fixed as in repairs complete all as specified and directed by Engr-in-Charge.
S&F Stop valves chromium plated 15 mm dia screwed down, high pressure with crutch or butter fly handle, screwed both ends, fixed with PVC connections 15 mm size with PTMT nuts of length 600mm as in repairs complete all as specified and directed by Engr-in-Charge.
S&F Soap dish any type fixed to plugs with chromium plated brass screws.in repairs complete all as specified and directed by Engr-in-Charge.
S&F Waste fittings,32mm brass , chromium plated for glazed ware sinks , basins , etc. with long screwed shanks and fly -nuts , flange end bedded in red lead cement and other end fixed in repairs complete all as specified and directed by Engr-in-Charge.
S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding flushing cistern and flush pipe) with Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed by Engr-in-Charge.
S&F Tubular towel rail, brass CP 20mm dia, D type, 60cm long between flanges in repairs complete all as specified and directed by Engr-in-Charge.
S&F Vitreous china squatting pan, 'Orrisa' pattern , size 580x440 mm white, with integral foot rests ( excluding flushing cistern and flush pipe) complete all as specified and directed by Engr-in-Charge.
S&F PVC valveless syphonic action type ,flushing cistern Low level white,with,with inlet ball valve ,float and handle 10 Ltr capacity including brackets.in repairs complete all as specified and directed by Engr-in-Charge.
M&L Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. Or securing with complete all as specified and directed by Engr-in-Charge.
All as per above srl No. 51 but 6 to 8mm dia complete all as specified and directed by Engr-in-Charge.
Removal of all loose/ unsound/ bad/ damaged concrete or plaster existing RCC structure of slab/beams/walls by using chesel/hammar .Cut and remove unsound reinforcement bars, wires etc without damaging the sound reinforcement . clean loose rust from bars manually with brush . fixing mild steel welded fabric of weight exceeding 3.5 kg but n- exc 4kg /Sqm with existing bars or by welding on it (supplementary bars wiil be measured and paid separately). Applying eppoxy bonding agent and making good with polymer modified plaster and micro concrete as required thickness over a coat of rust removing alkaline primer and match the finishing to the existing surface including necessary form work The lead and lift as required including provision of standard steel scaffolding upto a height of 20m. shall deemed to have been included in the quoted rate and no extra shall be admitted at a laterdate in this respect complete all as specified and directed by Engr-in-Charge.
Dismantling unframed timber scantlings 40 sq. cm and over in section, in any position from the walking way of ATC tower complete all as specified and directed by Engr-in-Charge.
M&L for 30 mm thick second class hardwood in Planed one side, with butt joints and fixed with screws complete all as specified and directed.
Taking down all existing roof treatment and demolition of cement concrete padding/levelling course incl wire brushing and cleaning loose dust etc from surfaces of RCC roof incl flashing and juntion of parapet complete all as specified and directed by Engr-in-Charge.
M&L for water proofing treatment to non assessible RCC roofs by applying one coat of bitumenous primer @ 0.30 ltr/sqm on the prepared surface of plaster after drying of plaster apply a coat of hot blown 85.25 grade bitumen @ 1.2 kg /Sqm and providing & laying APP based polymeric modifed membrane with polyster non woven reinforced of weight not less than 3kg/Sqm 5 layered 3 mm thick with polythene finished sealing with side overlaps of 75mm & 100 mm laps at the ends of membrane by torch application method and binded with fine sand in dry condition @ 0.5 kg/Sqm dusted over the bitumen coat complete all as specified and directed by Engr-in-Charge.
M&L for rendering 15 mm thick avg in CM 1:3 on roof top finished even and smooth without using extra cement complete all as directed by Engr-In-Charge
M&L for Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in setting in CM 1;6 complete all as specified and directed by Engr-in-Charge.
M&L for Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1;4 complete all as specified and directed by engr in charge
Dismantling false ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs any thickness complete all as specified and directed by Engr-in-Charge.
M&L for Gl powder coated frame work for seamless ceiling comprising of Gl powder coated perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. and Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long with 6 mm thick fibre cement building boards (E-Board) acaustic false ceiling fixed or laid/ inserted to timber/GI/Aluminium framework on flat ceiling complete all as specified & as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in-Charge..
S&F MS works framed work such as framed guard bars ,barred iron doors , ladders , framed balusters , railings,frame work of water tanks and similar work conforming Fe 290 , Gde -E -165 , for ornamental and intricate design complete all as specified and directed.
Taking out old serviceable glass of any description, from old wooden or metal frames, or stone, concrete or brick surrounds, any thickness or size; hacking out old putty or removing beads etc, including making good breakages in taking out and handling removing to store or stacking for reuse complete all as specified and directed by Engr-in-Charge.
S&F in repairs Vitreous China half stall urinal complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe and complete connecting items as per existing complete all as specified and directed by Engr-in-Charge.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed by Engr-in-Charge.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and directed by engineer in charge.
S&F in 25 mm thick lnsulated PVC Wall Lining consisting of PVC Insulated Panel with Single Side Prelam PVC sheet stuck to 2mm thick plain colour PVC sheet duly fitted into the wall as per specifications and drawing complete all as specified and directed by Engr-in-Charge.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed by Engr-in-Charge.
S&F Pre-painted galvaume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of camouflage colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
S&F 4 mm thick PVC tiles/ sheets, laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors complete all as specified and directed by Engr-in-Charge.
Taking down roof trusses, coupled rafters or trussed beams exc 4 mtr upto 8 mtr complete all as specified.
Dismantling unframed timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed by Engr-in-Charge.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing MS chequered plate 6 to 8mm thick plain, cut to shape forming holes and welded to truss and verticle post all as required, complete confirming to Fe 410-W(Gde- 250) quality-B complete and all as specified and directed by Engineer-in-Charge.
M&L for Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges , in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engr-in-Charge.
Dismantling Stone slabs and tiles laid dry of any description or thickness in floors, aprons etc. and set aside for relaying complete all as specified and directed by Engr-in-Charge.
M&L for 100 mm thick Cement concrete type C- 2, 1:3:6 (40mm graded aggregate) as in subabse for interlocking tiles complete all as specified and directed by Engr-in-Charge.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed by engr in charge.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to ( IS-15658-2006) of 80 mm thickness M-40 Grade. Except tiles Complete all as specified and directed. Note:- Paver blocks obtained from item No. 79 above shall be used.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade, Complete all as specified and directed. Make:- NTC / NITCO / ULTRA / JOHNSON / RUCHI INDUSTRIES, UDHAMPUR MOHINDRA [M/S MOHINDRA INDUSTRIES, PATHANKOT]
S&F Mild steel, plain, black sheet 2mm thick in Control pannel for ATC with 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed by Engr-in-Charge.
S&F Mild steel plain sheet 1.6 mm thick in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood r steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, complete all as specified and directed by Engr-in-Charge. Note :- The fabrication will be done at site as per requirement.
Supplying and fixing Neoprene/ EPDM rubber gasket in Aluminum ventilators fixed /openable type complete all as specified and directed by Engr-in-Charge.
Fixing only glass of any description in existing metal frames with necessary rubber gasket and beading carefully. Any damage to the glass will be bear by the contractor complete all as specified and directed by Engr-in-Charge..
Taking down doors chowkat or frame exc 1.5 Sqm & Not exc 4 Sqm but with shutters (without taking off shutters from the frames) and refixing at same opening after repair complete all as specified and directed.
Taking down 15 mm bore steel water tubing and connection from wall and floor complete all as per directed including cleaning for refixing or removal from site as in repairs complete all as specified and directed by Engr-in-Charge.
Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified. as in repairs complete all as specified and directed by Engr-in-Charge.
Taking down 20 mm bore steel water tubing and connection from wall and floor complete all as per directed including cleaning for refixing or removal from site as in repairs complete all as specified and directed by Engr-in-Charge.
Supply and laying of 25 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed by Engr-in-Charge.
S&F 20 mm outer dia Brass Elbow complete all as specified and directed by Engr-in-Charge.
S&F 20 mm outer dia Brass Elbow (3/4 X ½) complete all as specified and directed by Engr-in-Charge.
S&F 20 mm outer dia Brass Tee complete all as specified and directed by Engr-in-Charge.
S&F 20 mm outer dia Male Brass Threaded Adaptor (MTA/ MBTA) ) complete all as specified and directed by Engr-in-Charge.
S&F 20 mm outer dia Female Brass Threaded Adaptor (FTA/ FBTA) complete all as specified and directed by Engr-in-Charge.
S& F 25 mm outer dia Tank Adaptor complete all as specified and directed by Engr-in-Charge.
Cutting chases for concealed water tubing etc., and making good, cutting not exc 10 cm girth in stone or PCC wall complete all as specified and directed by Engr-in-Charge.
S&F one piece Vitreous China wash down water closet pan with cistern (670 x 365 x 705mm) complete all as specified and directed by Engr-in-Charge.
S&F ABS health faucet with wall hoock and 1 Mtr SS chrome finished Braded rubber hose complete all as specified and directed by Engr-in-Charge.
M&L cool roof SRI (Solar Reflective Index) tiles of size 300x300 mm 10mm thick of of colour as approved by GE laid over 15mm thick bedding in CM (1:4), joints grouted and flush pointed in CM (1:3) mixed with 5% crude oil by weight of cement complete all as specified and directed by Engr-in-Charge. Make:- Johnson/Orient Bell/Kajaria/Sun Heat
M&L for rendering 15 mm thick rendering in CM 1:6 on the top surface of APP membrane finishing fair and even without using extra cement with WPC @ 3% by the weight of cement WPC compound will be measured and paid saperatly complete all as specified and directed by Engr-in-Charge.
S&F solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tubes, as per specifications and drawing complete all as directed by Engineer-In-Charge.
S&F factory made Factory Made Solid PVC Moulded Door Shutter, with wood free EPS 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2 mm plain colour PVC sheet on back face, supplying & fixing in frame at site as & drawing complete all as specified and directed by Engr-in-Charge.
S&F 100 mm size MS butt hinges medium weight cold rolled fixed/ welded to frame complete all as specified and directed by Engr-in-Charge.
S&F 125mm long aluminium,anodised, barrel tower bolts of extruded section complete all as specified and directed by Engr-in-Charge.
S&F 125mm size aluminium handles,cast type, anodised complete all as specified and directed by Engr-in-Charge.
Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with mitlti chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Doortransmission gear made of mild sleel with multi point locking system with strikes. SS Hinges heavy duty complete all as specified and directed by Engr-in-Charge.
S&F Providing and fixing factory made UPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. and of approved quality with 6 mm thick figured glass and ss wire mesh of 0.36 mm nominal dia and average width of aperture 1.40 mm, complete all as specified and directed by Engineer-in-Charge. Note:- The rate shall also include making all damages/plastering repair, leveling and making good in plumb all the cills and jambs of opening before fixing windows and , shall deemed to have been included in the quoted rate and no extra shall be admitted at a laterdate in this respect.
S&F Supply and fixing factory made uPVC white colour fixed glazed window/ hung ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Note:- The rate shall also include making all damages/plastering repair, leveling and making good in plumb all the cills and jambs of opening before fixing ventelators and , shall deemed to have been included in the quoted rate and no extra shall be admitted at a laterdate in this respect.
S&F fire proof wall panneling with perforated Gypsum board with round or square hole (ECHOBLOC) bonded to the back side with glass wool/mat of standard board size 1200 x 2400 mm and 12.5 mm thick (Quattro 41) with the following specification and metal framing section:- (a) Perimeter channel of size 20x28x30x0.50x3660 mm (b) Fixing plug and screw on vertical section (c) Board to be laid on metal section as per manufacturer specification. Metal section comprising on wall of section 80x26x51x0.5x3660 mm (d) Insert insulation 50mm thick of density 24Kg/Cum glass wool into the assembled in framing system and covered with chicken wire mesh as approved by Engineer in Charge . (e) Board are jointed with gypsum based jointing compound and appying two coats of plastic emulsion paint (interior) of any tint/colour, design/pattern as approved over a coat of base primer including prepration of surface. Note :- (a) Wall paneling shall be provided as per design and pattern approved by Eng-in Charge. (b) Work shall be got executed through athourised dealer of firm as approved by GE.
S&F Accoustic false ceiling with perforated Gypsum board 12.50 mm thick round or square hole (ECHOBLOC) bonded to the back side with glass wool/mat of standard board size 1200 x 2400 mm and 12.5 mm thick (Quattro 41) with the following specification of Metal framming accessories section and gypsum board :- (a) Board to be laid on metal section as per manufacturer specification, Metal section comprising of ceiling section 80x26x51x0.5x3660 mm. (b) Board to be laid on metal section as per manufacturer specification . Metal section comprising of intermediate section 15x45x15x0.9x3660 mm . (c) Insert insulation 50mm thick of density 24Kg/Cum glass wool fire proof into the assembled in framing system then lay chicken wire mesh on glass wool as approved by Engineer-in-Charge. (d ) Gypsum connecting clip of size 2.64 mm dia. (e) Perimeter channel of size 20 x 28 x 30 x 0.50 x 3660 mm (f) L angle length 3050 mm and base metal thickness 0.55 mm (g) Board are jointing with gypsum base jointing compound (h) Applying two coats of plastic emulsion paint of any tint/colour, design/pattern as approved over a coat of base primer on Gypsum board including preparation. Note : (i) False ceiling to be provided in slope /oval/ zig zag pattern at any height as per design and pattern approved by Engineer-in Charge. (ii) Unit rate quoted by contractor shall deemed to include all necessary scaffolding for any height. (iii) Work shall be got executed through athourised dealer of firm as approved by GE.
Supply only ACP (Aluminum composite pannel) 4 mm thick as in sash/partetion in doors of UPVC complete all as specified and directed by Engr-in-Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engr-in-Charge..
Taking down sub main wiring complete including fitting and fixtures, removing materials to store or keeping in safe custody and making good the disturbed surfaces of walls, floors, roof etc.complete all as specified and directed by Engr-in-Charge.
Taking down carefully unserviceable DB any type/size disconnecting and making good disturbed surfaces complete all as specified and directed by Engr-in-Charge.
Taking down carefully unserviceable MCB SP/SPN/Isolator of any rating/size complete all as specified and directed by Engr-in-Charge.
Material and labour for point wiring with two single core 1.5 sqmm cable (nominal area) stranded copper conductor, PVC insulated unsheathed cable, 1100 V grade in and including concealed PVC conduit of size not less than 20mm dia with sunken type pressed steel terninal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes including all accessories and using single core 1.5 Sqmm (nominal area) stranded copper conductor, PVC insulated unsheathed cable as in earth wire (green colour) connected to common earth dolly complete all as specified and directed for following :- (a) One light point controlled by one switch.
One 3 pin switch socket outlet point 5 Amps on independent board.
One 3 pin switch socket outlet point 5 Amps on same board.
All as per item No. 123 here in before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size complete all as specified and directed by Engr-in-Charge.
Refixing of old serviceable switch piano flush type ,single pole 5/15 amp complete all as specified & directed by Engr-in-Charge.
S&F Switch piano flush type single pole, one way 5 Amps 230 Volts AC circuit complete all as specified & directed by Engr-in-Charge.
S&F switch piano flush type,15 Amps, Single pole, two way complete all as specified and directed by Engr-in-Charge.
Refixing of old serviceable socket oulet 5/15 amp 230 Volts AC circuit complete all as specified and directed by Engr-in-Charge.
S&F socket outlet 5 Amps, 5 Pin flush type multipurpose, 230 Volts AC circuit complete all as specified and directed by Engr-in-Charge.
S&F socket outlet 2 in 1, 3 Pin 5 & 15 Amps, 230 Volts AC circuit complete all as specified and directed by Engr-in-Charge.
S&F ceiling rose surface backlite 65x50mm 3 terminals complete all as specified and directed by Engr-in-Charge.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed by Engr-in-Charge.
S&F bell push 5 Amps 230 V, AC circuit complete all as specified and directed by Engr-in-Charge.
S&F call bell ding dong 230 V AC circuit complete all as specified and directed by Engr-in-Charge.
S&F switch piano flush type,15 Amps, Single pole, two way complete all as specified and directed by Engr-in-Charge.
Taking down old and U/S light fittings conventional type from wall surface / ceilling or any position and making good the disturbed surfaces complete all as specified and directed by Engr-in-Charge.
Refixing old serviceable any type, any size of LED fitting at old/new position as required complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.
Supply & fixing SLEEK surface mounted square downlight 15 W for soft diffused lighting ,powder coated CRCA sheet steel housing with high efficiency translucent acrylic in center complete fitting with all fixing arrangement complete including taking down with complete all as specified and directed by Engr-in-Charge.
Supply & fixing MCB DB VTPN 8 ways,with metal double door , IP-43 protection suitable for MCCB as incommer and MCB as out going,VTPN DB's 415 volt 3 phase complete with appropriate size copper bus bar and neutral link as required at site and including cutting chases to wall for fixing of DB and making good distrubed wall/surface all as required at site i.e complete all as specified and directed by Engr-in-Charge.
S&F sheet metal enclosure MCB DB VTPN double door 4 way suitable for 415 V with 200 amps rated bus bar including flushed on walls and making good disturbed surfaces including taking down the old DB. Model6077 50 complete all as specified and directed by Engr-in-Charge.
S&F sheet metal enclosure distribution board SPN, 12 ways 240 volts, with 200 amps rated bus bar, with IP- 43 protection and double door, suitable for mounting MCB's all as specified and as directed including taking down old MCB DB complete all as specified and directed by Engr-in-Charge.
S&F MCB single pole, 240 volts, 5 Amps to 32 Amps, complete all as specified and directed by Engr-in-Charge.
S&F MCB single pole and neutral, 240 volts, 5 to 30 Amps, complete all as specified and directed by Engr-in-Charge.
S&F MCCB Tripple pole and neutral, 415 volts,125 Amps,4 pole 16 KA complete all as specified and directed by Engr-in-Charge.
S&F MCCB Tripple pole and neutral, 415 volts, 63 Amps,4 pole 16 KA complete all as specified and directed by Engr-in-Charge.
S&F MCB Tripple pole , 415 volts,32 Amps, complete all as specified and directed by Engr-in-Charge.
S&F Single pole and neutral enclouser with two pin and earthplug and socket complete with one single pole MCB with 240 V 20 AMPs complete all as specified and directed by Engr-in-Charge.
S&F P 17 tempra plug and socket DB's for provision of FP RCCB's 32 A all as per Cat No 607871 of Legrand or Equivalent .all as per specifified or directed by Engr in charge.
M&L for dismentling and installation of existing split type AC 1.5TR/2TR capacity in the location as directed including provision of 45x45x5mm angle iron frame work for mounting of out door unit , fixing of indoor unit with the following :- (i) Fixing of condensor unit with one number compressor and blower / fan housed in cabinet shell of wheather proof factory made unit (ii) Fixing of wall mounted eavporator unit housed in PVC cabinet including blower and supply air grill (iii) Fixing of refrigerant piping made out of copper of 3/8" for discharge line and 5/8" for suction line duly insulated for required length as per site. (iv) Preparation of angle iron frame for condemsing unit and painting with two coats of bituminous paint over a coat of primer as per site requirement. (v) PVC pipe for the drain water removal from the room Note : Extra refrigerant pipe will be measured and paid seperately other than retrived against removed one
Supply & Fixing Suction and discharge copper tubing 3/8" and 5/8" for split type AC including provision of insulation on the tubing complete all as specified and directed by Engr-in-Charge.
M&L for PVC insulated flexible multistranded copper cable 3 core 2.5 sqmm complete all as specified and directed by Engr-in-Charge.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick wall all as directed by Eng-in-charge.
M & L Sub main wiring complete with 4 runs of 6 Sqmm single core PVC insulated unsheathed cable 1100 V grade with multistranded copper conductor ISI marked drawn throughn and including PVC rigid conduit/PVC casing capping and conduit accessories fixed on surface/wall/ celing etc including provision of 1 runs of 6 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity complete all as specified and directed by Engr-in-Charge. Note : Four runs of copper conducter and one runs of earth copper conducter shall be measured as one length complete all as specified and directed by Engr-in-Charge.
Sub main wiring complete with two runs of 6 sqmm single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories ,fixed to walls / roofs / floors etc., with one run of 6.00 Sqmm single core multistranded copper conductor as earth continuity conductor, all as specified inclduing dismantling unseriveable sub main wiring including accessories complete all as specified and directed by Engr-in-Charge. Note : Two runs of copper conducter and one run of earth copper conducter shall be measured as one length complete all as specified and directed by Engr-in-Charge.
Sub main wiring complete with two runs of 4 sqmm single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories ,fixed to walls / roofs / floors etc., with one run of 4.00 Sqmm single core multistranded copper conductor as earth continuity conductor, all as specified inclduing dismantling unseriveable sub main wiring including accessories complete all as specified and directed by Engr-in-Charge. Note : Two runs of copper conducter and one run of earth copper conducter shall be measured as one length complete all as specified and directed by Engr-in-Charge.
S&F rigid non metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. of 25mm dia all as directed by Eng-in-charge.
S&F junction box 1 to 4 way suitable for 25mm dia conduit complete all as specified and directed by Engr-in-Charge. Note : Two runs of copper conducter and one runs of earth copper conducter shall be measured as one length.
Taking down the defective ceiling fan of any sweep and make after disconnecting electrically & mechanically and transporting to the work shop dismantling, examine & carry out the repairs as required and brought back to site, re-fixing, testing in all respect for smooth running and comprising of the following:- (a) Servicing/ overhauling the ceiling fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing.
All as per item No 159 here in before, but re-winding the burnt/short circuited winding with same guage supper enameled copper wire to maintain speed at load.
All as per item No 159 here in before but applying two coats of synthetic enamel paint after preparation of surface complete.
Taking down the repairable exhaust fan of any size sweep, any make, single phase, 230 volts, 50 hz, AC after disconnecting electrically and mechanically and transporting to the work shop dismantling, examine & carry out the repairs as required and brought back to site, re-fixing, testing in all respect for smooth running and comprising of the following:- (a) Servicing/overhauling the exhuast fan by thoroughly clelaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing.
All as per item No 160 here in before, but re-winding the burnt/shourt circuited winding with same cauge supper enameled copper wire to maintain speed at load.
All as per item No 160 here in before but applying two coat of synthetic enamel paint after preparation of surface complete.
Supply and fixing bus bar chambers factory febricated suitable for 3 Phase & neutral iron clad with 4 Nos 200 amp rated copper strips with two Nos Earthing connection bolt with locking arrangement front door operated complete fixed flush in wall and making good the disturbed wall surfaces complete all as specified and directed by Engineer-in-charge.
Cutting / cheasing of existing brick wall / any type of wall for inserting PVC/ Steel conduit upto 40mm and making good the disturbed surface to match with the existing wall complete all as specified and directed by Engineer-in-charge.
Supply and fixing in wall PVC conduit of 40 mm size duly fixed in wall or clamped on wall/ surface complete all as specified and directed by Engineer-in-charge.
Supply and fixing in wall PVC conduit of 25 mm size duly fixed in wall or clamped on wall/ surface complete all as specified and directed by Engineer-in-charge.
Excavation in trenches not exc 1.5 m wide and not exc 1.5m deep for foundation etc or for laying of cable etc and getting out in any type soil, complete all as specified and directed by Engr-in-Charge
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm in any type soil, complete all as specified and directed
Removing excavated soil to a distance exc 50m and not exc 250 m and depositing where directed at a level not exceeding 1.5m above the starting point , complete all as specified and directed by Engr-in-Charge
Sand cushioning to the under ground electric cable complete all as specified considering 19.75 of SSR part -I complete all as specified and directed by Engr-in-Charge
M&L for Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified and directed by Engr-in-Charge
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 120 sqmm, 3.5 core including cable lugs, jointing materials,GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engr-in-Charge.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 70 sq mm, 3.5 core including cable lugs, jointing materials,GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engr-in-Charge.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 35 sq mm, 3.5 core including cable lugs, jointing materials,GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engr-in-Charge.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 16 sq mm, 4 core including cable lugs, jointing materials,GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engr-in-Charge.
Material and labour for renewal earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel wire 4 mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 15 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion, complete all as specified and directed by Engr-in-Charge. Note:- (i) If the desired earth resistance is found within limit shall be redone by contractor at no extra cost. (ii) Quoted rates shall be deemed to include for earth wire with protection pipe up to 7.5 M length.
Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel strip of size 25 x 4 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 32 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion, complete all as specified and directed by Engr-in-Charge.
S&F DLP PVC trunking system of size 32x20mm complete with and caps, chargeble internal and external angles, flat joints white cover joint etc, complete all as specified and directed by Engr-in-Charge
S&F GI tubing, 50mm bore medium grade with and including all fitting and fixtures laid in trenches complete all as specified and directed
S&F GI tubing, 80mm bore medium grade with and including all fitting and fixtures laid in trenches complete all as specified and directed
M&L for Breaking road, pavement, hard standing, tiles of any type, including excavation of subbase, soil upto the depth of 0.60 mtr and width 0.45 mtr by mechanical means for laying new pipeline and remove old pipe lines and including making good to the disturbed surfaces matching with existing after laying of new pipeline including removal of surplus material to nearby dumping point complete all as specified and directed by Engr-In-Charge.
pardeep singh marwaha
JCC ENGINEERS PRIVATE LIMITED
Bidder Name
pardeep singh marwaha
D R CONTRACTORS
JCC ENGINEERS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .