| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC KRISHNA SOCIETY OPP TODI XRAY AND DIAG CENTRE MAKUM ROAD TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹39.9 L+₹1.4 L (3.75%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹41.6 L+₹3.2 L (8.24%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 |
| Sl No | Description | Qty | Unit | pee kay construction L2 | Chander Mohan Arora Contractor L3 | ss enterprises L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down cement plaster on brick/ stone/ concrete walls / ceiling incl racking out joints etc,hacking for key, scrubing down with water etc & dispose off debris upto a distance n exc. 500 mtrs where directed complete all as specified and directed.
Note: Rate applicable upto 6 mtr height incling all scaffolding work | 2,140 | Sqm | 20 ₹42,800 Lowest | 20 ₹42,800 Lowest | 30 ₹64,200 |
| 2.00 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in CM 1:4. finishing even and fair complete all as specified and directed. (WPC shall be measuared seperatly and paid @ 200ML for 50kg cement bags or as per manufacturer's instructions).
Note : Rate applicable upto 6 mtr height including all scaffolding work | 1,500 | Sqm | 275 ₹4,12,500 | 200 ₹3,00,000 Lowest | 230 ₹3,45,000 |
| 3.00 | M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces on walls in CM 1:6. finishing even and smooth without using extra cement complete all as specified and directed. | 460 | Sqm | 275 ₹1,26,500 | 200 ₹92,000 Lowest | 220 ₹1,01,200 |
| 4.00 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces on ceiling in CM 1:3. finishing even and smooth without using extra cement complete all as specified and directed. | 180 | Sqm | 250 ₹45,000 | 240 ₹43,200 | 220 ₹39,600 Lowest |
| 5.00 | M&L for preparation of newly plastered surface of walls and applying two coat of oil bound distemper over a coat of chalk whitening over newly plastered surfaces of walls, pillars cornices etc complete all as specified and directed. | 460 | Sqm | 40 ₹18,400 | 35 ₹16,100 Lowest | 45 ₹20,700 |
| 6.00 | M&L for applying three coat of white wash on ceiling surfaces incl preparation of newly plastered ceiling surfaces complete all as specified and directed. | 180 | Sqm | 30 ₹5,400 | 15 ₹2,700 | 12 ₹2,160 Lowest |
| 7.00 | Material and labour for preparation of newly plastered surface on wall and applying two coats of Apex paint (Camouflage pattern) over a coat of alkali resistant primer at a height not exceeding 6m above or below GL in camouflaging pattern complete all as specified and directed. | 1,500 | Sqm | 60 ₹90,000 Lowest | 150 ₹2,25,000 | 65 ₹97,500 |
| 8.00 | Supply only liquid WPC complete all as specified and directed. | 55 | Ltr | 250 ₹13,750 | 100 ₹5,500 | 50 ₹2,750 Lowest |
| 9.00 | Demolition of cement concrete in ground floors and pavings inclding by mechanical means if required complete all as specified and directed. | 63 | Cum | 200 ₹12,600 | 300 ₹18,900 | 2 ₹126 Lowest |
| 10.00 | M&L nominal mix cement concrete (1:1½:3) type A-1 using 20mm graded stone aggregate as in floor and pavings etc finishing surfaces fair & even witout using extra cement complete all as specified and directed. | 58 | Cum | 6,000 ₹3,48,000 | 5,500 ₹3,19,000 Lowest | 7,000 ₹4,06,000 |
Tender Value
₹49.2 L
EMD Value
₹98,340
Closing Date
7 Aug 2025, 6:00 pmClosed
GE NAMS
GE NAMS Amritsar
SPL REPAIR TO ESH NO 05 AND 40, PROVN OF HARD STANDING FOR VEH PARKING NEAR CP-5, PROVN OF 01 X HIGH MAST SECURITY LIGHT AND PROVN OF 25 x GEYSERS AT BLDG NO P-3 (COOK HOUSE), P-6 (OR LINES) AND P-17 (JCO MESS) AT NAMS
2025_MES_719693_1
GE NAMS-64/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE NAMS
category a(i) b(i)
8 documents required · 8 mandatory
₹500
GE NAMS
₹98,340
1 Oct 2025
10 Jul 2025
14 Aug 2025
10 Jul 2025
7 Aug 2025
24 Jul 2025
Amount
Taking down cement plaster on brick/ stone/ concrete walls / ceiling incl racking out joints etc,hacking for key, scrubing down with water etc & dispose off debris upto a distance n exc. 500 mtrs where directed complete all as specified and directed. Note: Rate applicable upto 6 mtr height incling all scaffolding work
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in CM 1:4. finishing even and fair complete all as specified and directed. (WPC shall be measuared seperatly and paid @ 200ML for 50kg cement bags or as per manufacturer's instructions). Note : Rate applicable upto 6 mtr height including all scaffolding work
M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces on walls in CM 1:6. finishing even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces on ceiling in CM 1:3. finishing even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surface of walls and applying two coat of oil bound distemper over a coat of chalk whitening over newly plastered surfaces of walls, pillars cornices etc complete all as specified and directed.
M&L for applying three coat of white wash on ceiling surfaces incl preparation of newly plastered ceiling surfaces complete all as specified and directed.
Material and labour for preparation of newly plastered surface on wall and applying two coats of Apex paint (Camouflage pattern) over a coat of alkali resistant primer at a height not exceeding 6m above or below GL in camouflaging pattern complete all as specified and directed.
Supply only liquid WPC complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings inclding by mechanical means if required complete all as specified and directed.
M&L nominal mix cement concrete (1:1½:3) type A-1 using 20mm graded stone aggregate as in floor and pavings etc finishing surfaces fair & even witout using extra cement complete all as specified and directed.
M&L for 100 mm thick PCC 1:2:4 Type B-1 (using 20mm graded stone aggregate) as in flooring laid in panels incl finishing the cement concrete surface even and fair with using extra cement including necessary form work etc inclunding demolition of old cement concrete complete all as specified and directed .
S & F of Plastic dividing strips, 38mm x 1.5 mm thick inserted in position,confirm to design complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M & L for brick work with sub class 'B' bricks in CM (1:6) straight or curved on plan exc 6 mtrs mean radius, complete all as specified and directed.
Removing surplus excavated material (old PCC debries) to a distance exceeding 500 mtr n exc 1.00 Km and depositing where directed at a level n.exc 1.50 mtr above the starting point complete all as specified and as directed.
M & L for taking down of old MS iron framed doors (double leaf heavy weight) by dismantling of MS ironwork/ RCC/ brickwork in side wall/lintel beam/ floor beam etc and refixing the same after fixing of three nos of suitable pintle hinges in each leaf /or other suitable fixing arrangment i.e. MS Plates, Pintel, hinges, angle, tee, chanel section as per the site requirements including necessary welding rivettng etc and provn of heavy duty running rail at bottom of floor and necessary and adequete rolling arrangment to the gate for smooth opening and closing etc including fixing of rail, braces, gusset plates complete drilled for fixing of steel sheeting or other covering items fixing complete Including M&L for providing RCC 1:1.5:3 type A-1(using 20 mm graded stone agg) as in lintel beam, floor beams, pintle hinges etc including supply and fixing/ welding/ cutting of rusted bar and providng of suitable dia addl MS TMT bars & stirrups/ including necessary form work etc complete all as specified and directed by Engr-in-Charge. Note: (i) MS structural work only will be paid and measured separately. (ii) Necessary scaffolding/ errecting arrangement of Gates as required shall be inclusive in the rates.
S & F for MS work of any type such as frame work, pintel, hinges, and other shape as required or any type of frame work complele as in door or gates of angle and other section with gusset plates, rails, braces etc and similar work complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M & L for 50mm thick PCC (1:2:4) type B-0 (12.5 mm graded stone aggregates) mixed with liquid WPC as per manufacturer instructions as in sloping roof padding complete all as specified and directed. Note: WPC shall be measured and paid seperately.
M & L for applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including cleaning surfaces etc including APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid on roof and sunken portion on bitumen surfaces by forced application including chase cutting in roof and making good with CM(1:4) complete complete all as specified and directed.
Material and labour for repairing of RCC projection, chajjas, facia,bands, shelves, beams, RCC railing, balcony and similar works by dismantling of loose/ disintegrated portion of RCC at any height and in any situation floor (including provn of support, formwork and welding of reinforcement if required with wire mesh of weight 3 kg/ sqm and dubbing/ filling with PCC (1:2:4), type B-0, using 12.5 mm graded aggregate,15 to 25 mm thick after applying cement slurry @ 3 kg/sqm, finished even and smooth to desired shape and applying two coats of painting as existing in building to match with the existing surfaces complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as pecified and directed.
M&L Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, etc complete all as specified and directed.
M & L for Hard core, broken Broken stone boulders to gauge n exc 63mm complete all as specified and directed
M & L for 100 mm thick PCC 1:4:8 type D-2, using 40 mm graded stone agg as in sub base etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and any position not otherwise specifically provided complete all as specified and directed
M & L for factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and directed.
Taking down aluminium/copper point wiring from existing conduit / batten (light, fan, socket or power) complete such as switches, ceiling rose, pendent, regulators, socket, light fittings etc and removing material from site and making good the disturbed surface of wall / floor etc, complete all as specified and directed
M&L for Flame proof point wiring with FRLS multi-stranded copper conductor single core PVC insulated fire resistant cable 1.5 Sqmm size sheathed cable including 20 mm size steel conduit concealed/surface flame proof as per latest specification/IS all flame proof steel conduit fitting and accessories i.e junction box,ceiling rose, inner/outer corners and inner/outer bends, tees etc. with continuous 1.5 sqmm PVC insulated fire resistant copper earth cable (green color) FRLS conneted to common earth including cutting chases to wall making good the disturb suface to match with the exisitng specification complete all as specified and directed. Note: (i) Flame proof rotary switch will be measured and paid separately. (ii) All fittings junction boxes, condiut pipe and conduit accessories shall be Flame proof and totally enclosed IP-65 proction and certified by CMRI Dhanbad also included in above rates. (iii) all flame proof items shall be got tested and certified as "totally enclosed" as suitable for use in explosive buildings on completion by the "Director" central mining research institute (CMRI) Dhanbad. The testing charges and arranging tools, plants,testing equipments etc shall be the responsibility of contractor.
M & L for FLP/WP switch 10 amps single pole ON/OFF complete all as specifief and directed
M&L Flame proof switch, socket and plug combined in LM 6 cable termination box in LM 6, 16A, 250V, ON/OFF complete all as specifief and directed.
Supply & fix LED light fitting 40 watt flame proof,weather proof CMRI certified recommended for Gas/Vapor group of I,IIA & IIB Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
M&L XLPE Insulated, Armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 10sqmm. 2 core complete all as specifief and directed.
Supply and installation in repairs, commissioning and testing Polycarbonate ASTA CPRI approved OEM made main LT Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES including MCCBs and indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of protection against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of ASTA CPRI TEST REPORT IN POLYCARBONATE only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket shall be internally embedded made of polyurethane. The Panels builder shall submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The ASTA CPRI report shall have mention of following tests performed and passed out satisfactorily - Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits.
The board manufacturer shall submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self-extinguishing]. Make-Hensel/Rittal/Emitter/Schneider Incomer (i) MCCB 100 A 4P 25 KA , Thermal Magnetic Released with Spreader links - 1 No (ii) Copper Bus bar TPN 150A with colour coding sleve-1 sets (iii) LED Indicator lamp R,Y,B - 1 Sets Outgoings (i) 40/63 A, 2 Pole C curve MCB-02 Nos. (ii) 6-32 A, 1 Pole C curve MCB-04 Nos. (iii) 63A,3 POLE Curve MCB-01 Nos.
Supply & fixing flame proof diStribution board 8 way LM6 including 16 A MCB - 05 Nos & 32 Amp MCB - 01 Nos MCB SPN 40A -02 Nos complete all as specified and directed.
Supply and fix MCBs single pole (SP) 6 to 32 Amps with 10 KA breaking capacity of 'B' series in distribution boards complete all as specified and directed.
S & F in repair MCB SPN, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘C’ curve type complete all as specified and directed.
S & F in repair MCB single pole, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘C’ curve type complete all as specified and directed.
M & L for laying of LT cable of 1100 volt XLPE insulated and PVC sheathed of size 50 sqmm 3.5core with cable gland including taking down old unserviceble cable complete all as specified and directed.
Excavation in trenches in any type of soil n.exc. 1.5 mtr wide and n.exc 1.5 mtr in depth complete all as specified & directed.
Returning, filling in, any type of soil and spreading in layers n. exc 25cm thick each layer including watering & well ramming complete all as specified & directed.
Removal of surplus soil to a distance n.exc 50 mtr & depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified & directed.
Supply,laying & fixing double wall corrugated (DWC) pipes made of high density polyethylene (HDPE) with all accessories i.e. all type of joints,sockets,elbows,bends and end cap etc. of size 75 mm outer dia and 61 mm inner dia complete all as specified and directed.
Supply and Fix FLP/WP Bulk head fitting 40W LED complete all as specified and directed.
Earthing complete with copper earth plate electrode 600x600x3.15mm thick, burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth strip 20x3 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI medium grade protection pipe, 20mm dia GI light grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 40mm bore up to 5 mtr length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal to a distance not exc. 50m, testing on completion complete all as specified & directed .
Supply and erection of 16 mtr high mast having holding arrangement for 08 flood lights of capacity 200w carriage in symmetrical system , base & Top outer dia 360 & 150 , No of section 2 , thickness 3/3, base plate dia 850x30 , PCD 445 complete all as specified and directed. Note: any civil work such as excavation, pcc etc. Deemed to be included in the quoted rate.
Supply of high mast control panels all as specified and directed by Engr-in-charge. NOTE: The panel shall have MCCB as incomer and shall have MCB outgoing feeders for the lights plus two spare (Each Flood light of mast shall have one SP MCB in the high mast control panel). One number VIF meter shall be available on each panel to indicate the electrical parameters like wattage , current , voltage , aviation obstruction light shall be on a 24 Hour timer so that if operates daily independent of the operation of flood lights.
Supply and fix Aviation lilght( single dome) IP 66 complete all as specified and directed.
Supply & Fix flood Light Luminaire 200 watt with high power LED warm /cool light , supply voltage 220/240/50 Hz, light engine driver base pole adapter, pressure die cast polycarbonate, powder coated in IP 66 life of 50000 hrs incliding protection of O/C, S/C, O/V, over temperature and lightning protection inbuilt complete all as specified and directed.
Supply and laying, of LT underground cable XLPE insulated, inner PVC sheathed, galvanized steel strip armoured, PVC sheathed electric power cable with stranded compact aluminium conductor 1100 volts grade 25 Sq mm 4 core confirming to IS:7098 (Part-I) with latest amendements, suitable for earthed system laid in duct/trench/along pole etc
Labour for drilling hole under the road with the help of drilling machine without damaging the road horizonally for rod crossing including laying GI tubing of size 40mm dia light grade for cable protection complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade ) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil and connecting to earth up to 6 meter length complete all as shown in electrical plate no 3 of SSR PART 1 , with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switche, DBs) complete all as specified & testing on completion.
Supply and Fix Storage water heater (Geyser) of 25 litre capacity 230V AC, 50HZ having element of 2 KW of COPPER/INCOLOY alloy , Rust proof outer body,high density PUF insulation, BEE 5 Star Rated ,Inner tank of SS 304 which can sustain pressure of minimum 7 Bar working pressure and having multifunction safety valve plug top , making electric and water connection complete all as specified.
Supply and fixing of brass chormium plated angle valve, fancy type of size 15mm dia screwed down for high pressure, complete all as specified and directed.
Supply and fixing of PVC Connection with stainless steel nuts (Hot/cold) of size 15 mm x 600 mm complete all as specified.
Supply and fixing Brass chromium plated fancy type bib tabs of size 15 mm dia bore short body, screwed down for GI pipe or for brass ferrule and fixed complete all as specified
M & L for sub main wiring with 1100 volt grade two single core PVC insulated and unsheathed cable with stranded copper conductor 2.5 sqmm drawn into and including electrical grade PVC conduit not less than 20 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 2.5 sqmm multi - stranded copper conductor as earth wire in green colour complete all as specified and directed.
Supply & fixing of single pole and neutral sheet metal enclosures with two pin & earth plug and socket with top complete with one single pole MCB of 20 Amps complete all as specified and directed.
Supply and fixing galvanized iron steel tubing medium grade 15 mm bore with all fitting and fixed to walls, ceiling and laid in floor complete all as specified and directed. Note: Quoted rate will include the cost of making water connection from existing supply line and making good of the wall surface etc all as specified and directed.
pee kay construction (BID ID -3378289)
Chander Mohan Arora Contractor (BID ID -3386031)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .