| 1 | L1₹31.0 LAccepted-AOC NEW ABADI KISHANPURA SURATGARH 335804 DISTT SRIGANGANGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | l2₹32.2 L+₹1.2 L (3.78%)Rejected-Finance BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | l2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹34.4 L+₹3.4 L (11.0%)Rejected-Finance RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L3 | Rejected-Finance Other than lowest bid | |
| 4 | l4₹35.1 L+₹4.0 L (13.0%)Rejected-Finance | l4 | Rejected-Finance Other than lowest bid |
Tender Value
Refer Docs
EMD Value
₹57,000
Closing Date
9 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Priyesh Srivastava
GE (AF) SURATGARH
PROVN OF CERTAIN REVENUE AND MINOR WORKS AT AF STN SURATGARH
2023_MES_612240_2
8098/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SURATGARH
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE (AF) SURATGARH
₹57,000
Yes
6 Nov 2023
18 Sept 2023
11 Oct 2023
18 Sept 2023
9 Oct 2023
25 Sept 2023
Amount
BOQ ( PROVN OF CERTAIN REVENUE AND MINOR WORKS AT AF STN SURATGARH)
Supply, installing, testing and commissioning factory made AMF Panel CPRI approved for 82.5 KVA capacity DG set indoor type platform mounted, suitable for accomodating all MCCBs with input voltage 415 volts 3.5 phase 4 wire, 50 Hz AC supply system complete all as specified and directed having aluminium bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 2 mm thick CRCA MS sheet with front and rear opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish over a coat of red oxide, primer on outside and two coats of red oxide primer on inside surface. The panel is installed over a platform of suitable size PCC 1:3:6 type C-2 using with 40mm crushed stone aggregate 20cm in thick foundation and of height upto 0.5 mtr all as directed at site . All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN aluminium bus bar of rating not less than 1.5 times rated capacity of individual MCCB and should be insulated with shrinkable PVC sleeves. The MCCB should be adjustable type. The scope of work includes provision of following . Note:- The Item includes control cabling from DG set to AMF Panel as per requirement)
Supply, installing, testing and commissioning factory made LT Panel CPRI approved feeder pillar box indoor type platform/Wall mounted, suitable for accomodating all MCCBs with input voltage 415 volts 3.5 phase 4 wire, 50 Hz AC supply system complete all as specified and directed having aluminium bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 2 mm thick CRCA MS sheet with front opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish over a coat of red oxide, primer on outside and two coats of red oxide primer on inside surface. The panel is installed over a platform of suitable size with PCC 1:3:6 type C-2 using with 40mm crushed stone aggregate 20cm thick in foundation and of height upto 0.5 mtr or has to mount on wall with proper fixing arrangement all as directed at site . All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN aluminium bus bar of rating not less than 1.5 times rated capacity of individual MCCB and should be insulated with shrinkable PVC sleeves. The MCCB should be adjustable type. (Location- DG Room)The scope of work includes provision of following. Note: All MCCBs should have adjustable thermal and magnetic settings
Incomer : (i) MCCB 4 pole 36 kA 150 Amp with thermal settiing 80-100% - 01 No. Outgoing : (ii) MCCB 4 pole 25 kA 63 Amp- 02 Nos . (iii) TPN 32 Amp- 02 Nos. Independent : (iv) TPN 16 Amp - 02 Nos (v) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of appropriate size . (vi ) Digital Voltmeter & Ammeter with necessary CT's.Make : AE/Conserve/Rishabh (vii) Spare chambers for future extension of MCCBs as per requirement - 01 spare compartment. (viii) Phase indiacting lamps (R-Y-B) - 01 set. (Make of MCCB/MCB/Contactor/Changeover switch:-ABB/ Legrand/ L&T/Schneider/Havells)
Supply, installing, testing and commissioning factory made LT Panel CPRI approved feeder pillar box indoor type platform/Wall mounted, suitable for accomodating all MCCBs with input voltage 415 volts 3.5 phase 4 wire, 50 Hz AC supply system complete all as specified and directed having aluminium bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 2 mm thick CRCA MS sheet with front opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish over a coat of red oxide, primer on outside and two coats of red oxide primer on inside surface. The panel is installed over a platform of suitable size with PCC 1:3:6 type C-2 using with 40mm crushed stone aggregate 20cm thick in foundation and of height upto 0.5 mtr or has to mount on wall with proper fixing arrangement all as directed at site . All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN aluminium bus bar of rating not less than 1.5 times rated capacity of individual MCCB and should be insulated with shrinkable PVC sleeves. The MCCB should be adjustable type. (Location- UPS Room)The scope of work includes provision of following. Note: All MCCBs should have adjustable thermal and magnetic settings
Incomer : (i) MCCB 4 pole 25 kA 63 Amp - 01 No. Outgoing : (ii) TPN 16 Amp- 03 Nos . (iii) SPN 6 Amp- 01 Nos. (iv) MCCB 4 pole 25 kA 63 Amp - 01 No Independent : (iv) MCCB 4 pole 25 kA 63 Amp - 02 Nos (v) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of appropriate size . (vi ) Digital Voltmeter & Ammeter with necessary CT's.Make : AE/Conserve/Rishabh (vii) Spare chambers for future extension of MCCBs as per requirement - 01 spare compartment. (viii) Phase indiacting lamps (R-Y-B) - 01 set. (Make of MCCB/MCB/Contactor/Changeover switch:-ABB/ Legrand/ L&T/Schneider/Havells)
Supply, installing, testing and commissioning factory made LT Panel CPRI approved feeder pillar box indoor type platform/Wall mounted, suitable for accomodating all MCCBs with input voltage 415 volts 3.5 phase 4 wire, 50 Hz AC supply system complete all as specified and directed having aluminium bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 2 mm thick CRCA MS sheet with front opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish over a coat of red oxide, primer on outside and two coats of red oxide primer on inside surface. The panel is installed over a platform of suitable size with PCC 1:3:6 type C-2 using with 40mm crushed stone aggregate 20cm thick in foundation and of height upto 0.5 mtr or has to mount on wall with proper fixing arrangement all as directed at site . All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN aluminium bus bar of rating not less than 1.5 times rated capacity of individual MCCB and should be insulated with shrinkable PVC sleeves. The MCCB should be adjustable type. (Location- RADAR Control Room)The scope of work includes provision of following. Note: All MCCBs should have adjustable thermal and magnetic settings
Incomer : (i) MCCB 4 pole 25 kA 63 Amp - 01 No. Outgoing : (ii) SPN 16 Amp- 01 Nos . (iii) SPN 6 Amp- 02 Nos. (iv) MCCB 4 pole 25 kA 63 Amp - 01 No (v) TPN 32 Amp-02 Nos. (vi) TPN 25 Amps-01 No. Independent : (vii) SP MCB 6-32 Amp -03 Nos. (v) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of appropriate size . (vi ) Digital Voltmeter & Ammeter with necessary CT's.Make : AE/Conserve/Rishabh (vii) Spare chambers for future extension of MCCBs as per requirement - 01 spare compartment. (viii) Phase indiacting lamps (R-Y-B) - 01 set. (Make of MCCB/MCB/Contactor/Changeover switch:-ABB/ Legrand/ L&T/Schneider/Havells)
M & L for point wiring (concealed) complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 4 sq mm (nominal area) multi stranded copper conductor cable drawn through in and including non metallic medium grade rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls/floors/ceilings etc by cutting chases using machine and making good the disturbed surface, with and including sunken type pressed steel/welded MS terminal box 1.2 mm thick bakelite laminated sheet top cover 3 mm thick/with flush type metal boxes modular type and 2.5 sq mm copper earth continuity wire connected to earth dully complete including modular sheets for modular switch and blanking sheet for the following complete all as specified and as directed by Engr-in-charge.
One 3 pin socket outlet, 15 Amps on independent board.
S & F socket modular type 16 Amps, 3 pin combine, 2 module,240 volts all as specified and as directed.
S & F switch modular type 16 Amps, 1 module,240 volts all as specified and as directed.
Supply, fixing ,laying and testing cable PVC sheathed unarmoured, electric cables 1100 Volts grade with multistranded copper conductor of size 4 sq mm 4 core all as specified and directed by Engineer In charge.
Supply, fixing ,laying and testing cable PVC sheathed unarmoured, electric cables 1100 Volts grade with multistranded copper conductor of size 16 sq mm 4 core all as specified and directed by Engineer In charge.
S & F Galvanised Tube 100 mm bore, 'Medium grade', ISI marked as per IS 1239 part-I with all fittings ISI marked including cutting, threading etc as per site requirement and drilling holes/fixing clamp set for taking branch connection from main pipe line in trenches/road/ nallah & fixed along walls/polls including mild steel clamps, screws etc, complete all as specified and directed by Engineer-in-Charge. Note: Earthwork shall be measured and paid seperately
S & F Galvanised Tube 50 mm bore, 'Medium grade', ISI marked as per IS 1239 part-I with all fittings ISI marked including cutting, threading etc as per site requirement and drilling holes/fixing clamp set for taking branch connection from main pipe line in trenches/road/ nallah & fixed along walls/polls including mild steel clamps, screws etc, complete all as specified and directed by Engineer-in-Charge. Note: Earthwork shall be measured and paid seperately
S & F Galvanised Tube 25 mm bore, 'Medium grade', ISI marked as per IS 1239 part-I with all fittings ISI marked including cutting, threading etc as per site requirement and drilling holes/fixing clamp set for taking branch connection from main pipe line in trenches/road/ nallah & fixed along walls/polls including mild steel clamps, screws etc, complete all as specified and directed by Engineer-in-Charge. Note: Earthwork shall be measured and paid seperately
Supply and fixing of Gun-metal, globe or gate valves screwed down high pressure, heavy duty (ISI marked), with iron wheel head, screwed both ends for iron pipe or for unions suitable for 25 mm bore pipe, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Gun-metal, globe or gate valves screwed down high pressure, heavy duty (ISI marked), with iron wheel head, screwed both ends for iron pipe or for unions suitable for 50 mm bore pipe, complete all as specified and directed by Engineer-in-Charge.
Material and labour for cutting of road ,cutting chases pining in making good to facing where required to edges of landing road,hard standing,etc,and cutting chases for concealed water tubing making good exc 20 cm but not exc 60 cm width and digging of excavation40 cm but not exc 1m depth in bituminous road /concrete surface and making good as existing surface by using 0.63 mm hard core as required including premixed high performance cold mix patching material ideal for instant as require high quality repairs to bituminous as well as concrete surface complete all as specified and directed.
Excavation in trenches loose/soft soil not .exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundations, laying water mains, pipes, cables, etc getting out and formaing bottom surface to required gradient complete all as specified and directed.
Returing filling in incl spreading leveling, watering and well ramming in layer not less than 25 cm each layer complete all as specified and directed.
Removing excavated material to a distance not exc 50M and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
Demolition of brick work or stone/boulder masonary built in cement mortar including all quions arches pillars etc, but excluding ashlar facings dressed stone work and precast concrete articles complete all as specified and directed.
Brickwork with subclass B bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Material and labour for plastering, Rendering 10mm thick on fair faces of brick work or concrete surfaces 1:4 complete all as specified and directed.
Construction of brick masonry valve pit of size 90cmx90cmx90cm (Type 'B') (internal dimensions) of chamber, depth of chamber to be reckoned from the top of PCC in foundation to top of MS cover and including MS sheet cover fabricated from 3.15mm thick MS sheet and frame of angle iron 50x50x6mm with fixing arrangement, hinges and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide on MS cover and frame including necessary excavation earth work in any type of soil returning, filling in, disposal of surplus soil, PCC (1:2:4) work, complete all as specified. (Ref drawing : CE AF/STD-28/94 sheet no 1/2 & 2/2 dated 01.02.94.
S&F ductile Iron pipes of 100mm bore with spigot and socketed ends, Class “K-7”, suitable for and including rubber tyton joints complete all as specified and directed.
Supply and fixing Cast iron sluice valve of size 100 mm bore both end flanged, long body, class PN-1.6 conforming to IS 14846 (ISI marked) with iron wheel and stainless steel spindle and fly nut, bolts, washers and rubber gasket etc, complete all as specified and directed by Engineer-in-Charge.
Construction of brick masonry valve pit of size 120cmx120cmx120cm (Type 'B') (internal dimensions) of chamber, depth of chamber to be reckoned from the top of PCC in foundation to top of MS cover and including MS sheet cover fabricated from 3.15mm thick MS sheet and frame of angle iron 50x50x6mm with fixing arrangement, hinges and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide on MS cover and frame including necessary excavation earth work in any type of soil returning, filling in, disposal of surplus soil, PCC (1:2:4) work, complete all as specified. (Ref drawing : CE AF/STD-28/94 sheet no 1/2 & 2/2 dated 01.02.94.
Material and labour for DI specials such as tees, bends of any size and radius, tapers, collars, tail pieces, caps and plugs etc complete all as specified and directed.
Supply, fixing,testing and commissioning of 5 HP three phase open well submersible pump along with required base frame with approved make and OEM reccomended size pipe connection as per the site requirement and as directed by Engineer In Charge. Make : Kirloskar KOS-520+ /Havells /Oswal.
Supply, fixing and testing 50mm dia pressure release/ relief valve in the delivery side of pump in any size of pipe complete all as specified and directed.
Supply & Fixing PVC insulated & PVC sheathed industrial cable for submersible pump motors, flat three core of nominal area of conductor 10 sqmm, 1100 volts, confoRMing to IS : 693, complete all as specified and directed.
Supply, laying/ fixing and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core including necessary saddles and clamping tools complete all as specified and directed.
Supply, installing, testing and commissioning factory made LT Panel CPRI approved feeder pillar box indoor type Wall mounted, suitable for accomodating all MCCBs and motor starters with input voltage 415 volts 3.5 phase 4 wire, 50 Hz AC supply system complete all as specified and directed having aluminium bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 2 mm thick CRCA MS sheet with front opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish over a coat of red oxide, primer on outside and two coats of red oxide primer on inside surface. The panel is installed over a platform of suitable size with PCC 1:3:6 type C-2 using with 40mm crushed stone aggregate 20cm in thick in foundation and of height upto 0.5 mtr or has to mount on wall with proper fixing arrangement all as directed at site . All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN aluminium bus bar of rating not less than 1.5 times rated capacity of individual MCCB and should be insulated with shrinkable PVC sleeves. The MCCB should be adjustable type. The scope of work includes provision of following.
Note: All MCCBs should have adjustable thermal and magnetic settings. Incomer : (i) MCCB 4 pole 25 kA 63 Amp - 01 No. Outgoing : (ii) TPN 32 Amps-02 No. (iii) DOL starters of approved make suitable up to 7.5 HP motors -02 Nos. Make L&T, Havells or equivalent. (iv) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of appropriate size . (v) Digital Voltmeter & Ammeter with necessary CT's.Make : AE/Conserve/Rishabh (vi) Phase indiacting lamps (R-Y-B) - 01 set. (Make of MCCB/MCB/Contactor/Changeover switch:-ABB/ Legrand/ L&T/Schneider/Havells)
Contract Amount shall be derived after affecting the amount of Schedule of Credit in General Summary on serial page No 17 of tender documents.
M/S Shree Ram Enterprises
SRI SAI CONSTRUCTION COMPANY
MISHRA CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .