Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹39.6 LAdmitted-Finance | -5.54% | ₹39.6 L | L1 | Admitted-Finance |
| 2 | L2₹41.5 L+₹1.9 L (4.81%)Admitted-Finance | -1.00% | ₹41.5 L+₹1.9 L (4.81%) | L2 | Admitted-Finance |
| 3 | L3₹42.4 L+₹2.7 L (6.92%)Admitted-Finance | +1.00% | ₹42.4 L+₹2.7 L (6.92%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | - | Rejected-Technical VC ORDER |
| 5 | Rejected-Technical | - | - | - | Rejected-Technical VC ORDER |
Tender Value
₹42.0 L
EMD Value
₹84,000
Closing Date
11 May 2026, 5:00 pmClosed
VICE CHAIRMAN GHAZIABAD DEVELOPMENT AUTHORITY
GDA OFFICE VIKAS PATH GHAZIABAD
Work of installing fire detector, smoke detector and fire extinguisher in the Authority office.
2026_GDAUP_1142795_1
666/4/PA-T/2025-26 Dt. 24.04.2026 (S.no-02)
Open Tender
Miscellaneous Works
Percentage
60 days
GHAZIABAD
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,009
AS PER LINK PROVIDED IN TENDER DOCUMENT
₹84,000
3 Sept 2026
27 Apr 2026
13 May 2026
27 Apr 2026
11 May 2026
27 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required. DSR 2025 SI 28.2.9 | 2 | Nos | - | - |
| 2 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. DSR 2025 SI 28.2.7 | 25 | Nos | - | - |
| 3 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required DSR 2025 SI 28.2.5 | 20 | Nos | - | - |
| 4 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. DSR 2025 SI 28.2.14 | 30 | Nos | - | - |
| 5 | Supplying, installation, testing & commissioning of intelligent addressable programmable sounder complete as required. DSR 2025 SI 28.2.6 | 30 | Nos | - | - |
| 6 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. DSR 2025 SI 28.5.1 | 4,000 | metre | - | - |
| 7 | SMOKE DETECTOR
Supplying, installation, testing & commissioning of Analog addressable communication, Dual integrated LED for 360° visibilty, conforms to EN54-7, LPCB approved, Environment friendly - meets RoHS legislative requirements, Height: 52mm installed in B501AP base, Diameter: 102mm installed in B501AP base, Weight: 97g (inc base), Max wire gauge for terminals: 2.5mm², Color: White, Material: PC/ABS, Operating voltage range: 15 to 28Vdc, Maximum standby current: 200µA at 24Vdc (no communication), 300µA at 24Vdc (LED blink enabled, once every 5s), Isolation current: 15mA at 24Vdc, Maximum continous current: 1A(Swith closed), Remote output voltage: 22.5Vdc @ 24Vdc, Additional loop resistance: typ 80 mohm @ 24V (max 170mohm @15V), Additional loop resistance using the B501AP: typ 20mohm (max 30mohm), Temperature range : -
30°C to +70°C Humidity: 10 to 93% relative humidity (non-condensing), Approvals EN54-17:2005, EN54-7:2000+A1:2002+A2:2006. MR | 392 | Nos | 3,160 | ₹12,38,720 |
| 8 | ADDRESSABLE FIRE PANEL
Supplying, installation, testing & commissioning of 4-8 loop networkable, Panel in its basic configuration has 4 loops. With two further MA-LIB2 Boards, the panel can be expanded to up to 8 loops in the same box, It is possible to assign addresses from 1 to 99. Set via the rotary-switches on the addressed devices, on the same loop can be connected 99 detectors and 99input/output modules, Basic loop: 4, Additional 2 loop card: 2, Main Display: 7" touch screen, Physical key: 5, Virtual zonal LED: 40, Souder output: 1(monitored 1A, Balanced with resistor or diode, Output: 1 Fault(N)/NC), 3 output alarm-Usr1-Usr2, configurable (NO/NC or monitored 1A, Balanced with resistor or diode), User 24VDC Output: 1 max 1Amp, Loop power: 750mA, USB: 1, Serial port: 1RS485 isolated repeater, 1RS232/485 isolated (Printer or TPP), Power supply: 24V-200w, Battery: 2x12V-38A, Panel networking CAN-BUS, max 64 panels, max 128 loops, Color(Plastic, Metal): RAL 9002, Wall mount, Flush, Rack mounting, Dimension: (HxWxD) 398x483x217.5) (H=9 rack units), Cable hole on top 21, Operating temperature: -5°C to +40°C, Storage temperature: -10°C to +50°C, Humidity: 5%-95% non-condensing, IP: 30 MR | 1 | Nos | 4,10,200 | ₹4,10,200 |
| 9 | PVC Box | 396 | Nos | 95 | ₹37,620 |
| 10 | Supply & Fixing of Fire extinguisher (ABC 1kg) With MAP 40% MR | 69 | Nos | 1,770 | ₹1,22,130 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_2134207.xls
BOQ • 0.33 MB
666_2.pdf
Tender Documents • 1.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .