Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹10.9 LAccepted-AOC 5A 24 ANSARI ROAD DARYA GANJ NEW DELHI 110002 | CENTRAL | DELHI | 110002 | ₹10.9 L | L-1 | Accepted-AOC Work Awarded |
| 2 | L-2₹11.3 LRejected-Finance A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | ₹11.3 L | L-2 | Rejected-Finance L2 rejected |
| 3 | L-3₹11.9 LRejected-Finance | ₹11.9 L | L-3 | Rejected-Finance L3 rejected |
| Sl No | Description | Qty | Unit | SACHDEVA ELECTRICALS L3 | M/S. A.K. Electricals L2 | ACE ENGINEERS BUREAU L1 |
|---|---|---|---|---|---|---|
| 1.00DSR | ||||||
| 1.00 | OD10498/2023-2024: DSR-2022 (5.1) Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. | 7 | set | 3,150 ₹22,050 | 3,000 ₹21,000 Lowest | 3,000 ₹21,000 Lowest |
| 1.00 | OD10499/2023-2024:DSR-2022 (5.12)Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. | 14 | metre | 20 ₹280 | 2 ₹28 Lowest | 80 ₹1,120 |
| 1.00 | OD10500/2023-2024:DSR 2022(12.37) Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metre length along the pole for protection of under ground cable as required. | 7 | each | 1,111 ₹7,777 | 300 ₹2,100 Lowest | 750 ₹5,250 |
| 1.00 | OD10502/2023-2024:DSR 2022(14.16.1) Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. 63 mm dia (OD- 63mm & ID-51mm nominal). | 39 | metre | 100 ₹3,900 | 150 ₹5,850 | 70 ₹2,730 Lowest |
| 1.00 | OD10503/2023-2024:DSR 2022(7.6.1) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm | 160 | metre | 6 ₹960 | 2 ₹320 Lowest | 10 ₹1,600 |
| 1.01 | OD10504/2023-2024:DSR 2022 (7.5.1) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required .Upto 35 sq. mm | 60 | metre | 6 ₹360 Lowest | 35 ₹2,100 | 10 ₹600 |
| 2.00AR | ||||||
| 2.00 | 122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm | 220 | metre | 50 ₹11,000 | 2 ₹440 Lowest | 70 ₹15,400 |
| 2.00 | 122.2.19:Fabrication,Supplying,Installation,testing,Commissioning of 12 mtr high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick(Single dip ) inside & out sides &suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories For High Mast head frame ,2 point suspension system, 5*2.5 sqmm Cu conductor with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminaries symmetrically And its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the high mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c 4Nos S.P MCB,63Amp.DPIsolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS. | 7 | each | 1,35,500 ₹9,48,500 | 1,30,000 ₹9,10,000 | 1,16,800 ₹8,17,600 Lowest |
Tender Value
₹14.8 L
EMD Value
₹29,536
Closing Date
7 Nov 2023, 12:00 pmClosed
Ex. Engineer (Elect)-II
OFFICE OF THE Ex. ENGINEER (ELECT)-II, SHAHDARA (N) ZONE, KeshavChowk, Delhi-110053
Provision of Semi high mast light pole with 150 watt LED fitting at Mpl Gym ,A-8 Mansarover Park , Mpl Mother Dairy park, Mpl Shri Ram Park Ram Nagar, Mpl Apna Park Ram Nagar in Ward no-222 Ram Nagar East under Shahdara (North) Zone
2023_MCD_172694_1
EE(E)-II/SNZ/MCD/23-24/TC-23/2
Open Tender
Electrical Works
Item Rate
90 days
As per NIT
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
₹29,536
22 May 2026
31 Oct 2023
8 Nov 2023
31 Oct 2023
7 Nov 2023
31 Oct 2023
Amount
OD10498/2023-2024: DSR-2022 (5.1) Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
OD10499/2023-2024:DSR-2022 (5.12)Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
OD10500/2023-2024:DSR 2022(12.37) Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metre length along the pole for protection of under ground cable as required.
OD10502/2023-2024:DSR 2022(14.16.1) Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. 63 mm dia (OD- 63mm & ID-51mm nominal).
OD10503/2023-2024:DSR 2022(7.6.1) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
OD10504/2023-2024:DSR 2022 (7.5.1) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required .Upto 35 sq. mm
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
122.2.19:Fabrication,Supplying,Installation,testing,Commissioning of 12 mtr high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick(Single dip ) inside & out sides &suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories For High Mast head frame ,2 point suspension system, 5*2.5 sqmm Cu conductor with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminaries symmetrically And its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the high mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c 4Nos S.P MCB,63Amp.DPIsolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS.
122.2.25:Providing and fixing of Stainless steel name plate of size 6×8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required
122.2.30.a:SITC of 150W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =150 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
OD10506/2023-2024:Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh i/c MV danger plate and grounding the protection system in suitable quality of CC etc .
M/S. A.K. Electricals
SACHDEVA ELECTRICALS
Bidder Name
SACHDEVA ELECTRICALS
ACE ENGINEERS BUREAU
M/S. A.K. Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
GCC.pdf
Tender Documents • 14.54 MB
POSwardNo222.pdf
Tender Documents • 0.18 MB
BOQ_189195.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].