Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.3 LAccepted-AOC N NO 6 OLD NO 10 1ST STREET KASTHURI BAI NAGAR AVADI CHENNAI 600054 | CHENNAI | CHENNAI | TAMIL NADU | 600054 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹28.8 L+₹2.2 L (8.25%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest tenderer |
Tender Value
₹24.2 L
EMD Value
₹48,400
Closing Date
21 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Narinder Singh, IDSE, SE(SAG)
CWE Chennai Pallavan Salai Chennai-600002
PROVN OF GUARD ROOM AND CONNECTED SERVICES AT OTA UNDER GE STM CHENNAI
2022_MES_560643_1
86510/E8
Open Tender
Civil Works - Others
Item Rate
180 days
GE STM CHENNAI
As per Tender Documents and NIT
8 documents required · 8 mandatory
₹500
GE STM CHENNAI
₹48,400
Yes
20 Jan 2023
31 Oct 2022
26 Nov 2022
31 Oct 2022
21 Nov 2022
7 Nov 2022
31 Oct 2022 - 5 Nov 2022
Amount
BOQ UPLOADED ON 31 OCT 2022
SCH "A" PART-I (CIVIL WORKS)
Surface excavation not exceeding 30 cm deep averaging 15 cm deep and getting out in any type of soil complete all as specified and as directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and not exceeding 1.5m depth and getting out in any type of soil all as specified and as directed.
Earthwork is deemed to be carried out by manual method. However mechanised method may be adopted without any extra cost to the government.
Earthwork in excavation by mechanical means (hydraulic excavator) in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m in any type of soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.0m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed.
Earthwork is deemed to be carried out by manual method. However mechanised method may be adopted without any extra cost to the government.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and as directed.
Removing excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Hardcore of gauge not exceeding 63mm of broken stone aggregate, deposited, spread and levelled in layers not exceeding 150mm thick, watered and rammed to a true surface complete all as specified and as directed.
Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
Plain cement concrete, type B1, 1:2:4, using 20mm graded granite stone aggregate as in surface channels and drains complete all as specified and as directed.
Plain cement concrete, type B1, 1:2:4, using 20mm graded stone aggregate as in copings, bed blocks and the like including weathering, slightly rounded or chamfered angles and throating and necessary formwork complete all as specified and as directed.
Reinforced cement concrete, RCC M-30, (Design Mix), using 20mm graded stone aggregate as in plinth beam, footing, bases of columns etc., complete all as specified and as directed.
Reinforcement shall be measured and paid separately as applicable.
Reinforced cement concrete, RCC M-30, (Design Mix), using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, shelves and the like complete all as specified and as directed.
Reinforcement shall be measured and paid separately as applicable.
Reinforced cement concrete, RCC M-30, (Design Mix), using 20mm graded stone aggregate as in beams, lintels over 1.5m span complete all as specified and as directed.
Reinforcement shall be measured and paid separately as applicable.
Reinforced cement concrete, RCC M-30, (Design Mix), using 20mm graded stone aggregate as in columns, pillars etc., complete all as specified and as directed.
Reinforcement shall be measured and paid separately as applicable.
Brickwork with fly ash bricks, old size, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 of designation 50 complete all as specified and as directed.
Use and waste of formwork to sides of concrete foundations, plinth beams and similar work; vertical or to batter rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, shelves and similar work not exceeding 200mm thick (horizontal or sloping) rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to sides and soffits of floor / roof beams and similar items including edges rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to sides of columns, pillars, stancions and similar work; square, rectangular or polygonal rough finished surfaces of concrete complete all as specified and as directed.
Cutting holes in brick walls in cement mortar for inserting holdfasts, depth of embedded portion of holdfasts or lugs measured from the face of jamb into the wall exceeding half brick but not exceeding one brick and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and as directed.
Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, as in IInd class hardwood complete all as specified and as directed.
Factory made plain, framed, panelled shutters (any number of panels), of IInd class hardwood, 35mm thick with panels of wood particle board with commercial face veneers complete all as specified and as directed.
Factory made Glazed and skeleton shutters, of IInd class hardwood, 35mm thick open rebated and prepared to receive glass, gauze, etc. (with sash bars), edges of framing plain, divided into squares, with plain, chamfered or rounded. mitred and rebated sash bars for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and as directed.
Glass or wire cloth as required shall be measured and paid separately.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, fixed in opening as per relevant drawing in SSR Part-II complete all as specified and as directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, fixed in frames as per relevant drawing in SSR Part-II complete all as specified and as directed.
Aluminium anodised barrel tower bolts, of extruded section and fixed, length of bolt 150mm complete all as specified and as directed.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, length of bolt 300mm complete all as specified and as directed.
Butt hinges, stainless steel, with stainless steel hinge pin and fixed to frame of size 100mm complete all as specified and as directed.
Aluminium handles, cast type, anodised of size 125mm complete all as specified and as directed.
Tubular towel rail, anodised aluminium alloy, 20mm dia, D type, 600mm long between flanges complete all as specified and as directed.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Mild steel as in framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors and similar work conforming to Fe-290, Gde-E-65 complete all as specified and as directed.
Mild steel as in small articles such as hold fast and like conforming to Fe-290 Grade-E-165 complete all as specified and as directed.
Mild steel TMT bars 10mm dia & over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in main reinforcement complete all as specified and as directed.
Mild steel TMT bars but 5mm dia and over upto and including 10mm dia, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups, spacers & binders complete all as specified and as directed.
Aluminium frame for doors, windows, ventilators with one or more rebates including ioining cleat for fixing etc. powder coated to minimum 50 micron thickness complete all as specified and as directed.
Aluminium sections powder coated powder coated to minimum 50 micron thickness as in styles and rails and handle of aluminium door / window shutters, except fixing complete all as specified and as directed.
(a) Rubber packing, screws etc. as required shall be measured fixing of shutters.
(b) Glass or wire cloth as required shall be measured and paid separately.
Fixing only aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary ioining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, and provision of anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21, 100mm long (2 Nos.), suitable handle (1 No.) , aluminum tower bolt 125mm (02 Nos) etc., complete all as specified and as directed.
(a) All aluminium sections including snap beading, joining cleats, glazing cilps etc. shall be measured under aluminium shutters separately as supply only.
(b) Glass or wire cloth as required shall be measured and paid separately.
(c) The fixtures given are for shutter of approximate size 0.50m x 1.50m.
Plain cement concrete, 1:4:8, type D2, using 40mm graded stone aggregate, 100mm thick as in sub-base complete all as specified and as directed.
Plain cement concrete, 1:2:4, type B0, using 12.50mm graded stone aggregate, averaging 25mm thick as in floor, finished fair and even complete all as specified and as directed.
Plain cement concrete 75mm thick, 1:3:6, type C1, using 20mm graded stone aggregate as in plinth protection / foot path / hardstanding, surface finished fair and even complete all as specified and as directed.
Non-skid ceramic coloured tiles, minimum 7mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeeding 0.11 sqm (300mm x 300mm), in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match of superior finish, grade B-II (a) quality over cement screed 1:4, 20mm thick applied with cement slurry at the rate of 3 kg / sqm complete all as specified and as directed.
Non-skid ceramic coloured tiles, minimum 7mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeeding 0.38 sqm (600mm x 600mm), in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match of superior finish, grade B-II (a) quality over cement screed 1:4, 20mm thick applied with cement slurry at the rate of 3 kg / sqm complete all as specified and as directed.
Non-skid ceramic coloured tiles, minimum 7mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeeding 0.11 sqm, (600mm x 150mm) in vertical surfaces such as skirting, dados, risers etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match of superior finish, grade B-II (a) quality including a backing coat of cement mortar 1:3. 10mm thick complete all as specified and as directed.
Glazed ceramic tiles of grade B-III coloured of size 350mm x 250mm / 450mm x 350mm, minimum 7mm thick in vertical surfaces such as skirting, dados, risers etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including a backing coat of cement mortar 1:3. 10mm thick complete all as specified and as directed.
Extra for forming fair finished drain or channel of upto 30cm inner girth in cement concrete using extra cement, including forms, moulds, mitred / stopped ends etc., complete all as specified and as directed.
Add for each 25mm or part thereof over 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred / stopped ends etc., complete all as specified and as directed.
Rendering 10mm thick in CM(1:6) on fair faces of brickwork or concrete surfaces finished fair and even complete all as specified and as directed.
Rendering 10mm thick in CM(1:6) on fair faces of brickwork or concrete surfaces as in walls finished even and smooth without using extra cement complete all as specified and as directed.
Rendering 15mm thick in CM(1:4) mixed with liquid water proofing compound on fair faces of brickwork or concrete surfaces as in walls finished fair and even without using extra cement complete all as specified and as directed.
Supply only liquid water proofing compound shall be measured and paid separately.
Rendering 5mm thick in CM(1:3) on fair faces of concrete surfaces as in ceiling finished fair and even complete all as specified and as directed.
Preparing newly plastered surfaces of wall and applying three coats of white wash on plastered wall surfaces including in narrow widths, bands, cornices, pilasters etc., complete all as specified and as directed.
Preparing newly plastered surfaces of ceiling and applying three coats of white wash on plastered ceiling surfaces including in narrow widths, bands, cornices, pilasters etc., complete all as specified and as directed.
Preparing newly plastered surfaces of wall,, applying two coats of cement paint over a coat of primer to match with the existing adjoining surfaces including in narrow widths, bands, cornices, pilasters etc., complete all as specified and as directed
Preparing newly plastered surfaces of wall, applying two coats of distemper oil emulsion white or tinted including in narrow widths, bands, cornices, pilasters etc., over a coat of alkali resistant priming paint, complete all as specified and as directed
Sheet glass, 4mm thick, ordinary quality and glazing with oil putty / snap beading in square not exceeding 0.5 sqm in each pane complete all as specified and as directed.
Preparing new surfaces of wood and wood based materials of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Preparing new surfaces of steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Preparing surfaces of wood and wood based materials, steel and iron work, new or old, as in ends of posts, backs of chowkats etc., area exceeding 0.10 sqm but not exceeding 0.50 sqm each and treated with tar or coal tar black paint and sanding complete all as specified and as directed.
Preparing surfaces of wood and wood based materials, steel and iron work, new or old, as in small articles such as stop, covers, gully gratings, hold fasts etc., , area not exceeding 0.10 sqm each and treated with tar or coal tar black paint and sanding complete all as specified and as directed.
Steel tubing, galvanised, medium grade, with all fittings such as bends, elbows, tees etc., and fixed complete to walls and ceilings or laid in floors of bore of pipe 15mm complete all as specified and as directed.
Steel tubing, galvanised, medium grade, with all fittings such as bends, elbows, tees etc., and fixed complete to walls and ceilings or laid in floors of bore of pipe 20mm complete all as specified and as directed.
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) , three layered hoisted and fixed in position all as specified in SSR Part-I of capacity 1000 litres complete all as specified and as directed.
Ball brass valves, high pressure, with polythene float and flynut complete, screwed both ends for iron pipe or brass ferrule and fixed, of bore of pipe 20mmcomplete all as specified and as directed.
Ball brass valves, high pressure, with polythene float and flynut complete, screwed both ends for iron pipe or brass ferrule and fixed, of bore of pipe 25mm complete all as specified and as directed.
Bib taps, cast copper alloy, chromium plated, with flange, with crutch or butterfly handle, screwed down, screwed both ends for iron pipe or for brass ferrule and fixed of bore of pipe 15mm complete all as specified and as directed.
Make shall be of Prayag Cat No. Neptune Series PIS-06 or equivalent of makes listed here-in-after.
Angle valves, fancy type, chromium plated, cast copper alloy, chromium plated with long shank and cup (concealed type) screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore of pipe 15mm complete all as specified and as directed.
Vitreous china wash down water closet pan (pedestal pattern) white (excluding flushing cistern and flush pipe) and including fixing of the following components viz. pedestal pan with "P" or "S" trap, seat and cover for pedestal pan, flushing cistern, brackets, chain and pull or lever handle, flushing pipe including jointing to socket of flushing rim and connecting pipe to union of flushing cistern, inlet and overflow pipe, anti-syphonage pipe or stopper fixed complete all as specified and as directed.
Flushing cistern, flush pipe, seat cover, P trap, WC connector, as required shall be measured and paid for under supply only separately.
Supply only PVC valveless, syphonic action type flushing cistern 10 litres capacity low level, white with inlet, ball valve, float and handle / push button, including brackets complete all as specified and as directed.
Supply only flush pipe of polyethylene of high density, 32mm dia for low level / high level flushing cistern complete all as specified and as directed.
Supply only of plastic water closet seat, white, complete all as specified and as directed.
Make shall be of Prayag Cat No. 513, Standard Series or equivalent of makes listed here-in-after.
PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed.
Vitreous china wash basin, white, flat back, size 550mm x 400mm excluding taps, waste fitting, but including brackets and including fixing of the following components viz. pillar taps, waste fittings and union, plugs and chains and connecting upto supply pipes, wastes or traps, screws, plugs, cement mortar and other subsidary materials required for fixing including cutting for and pinning in ends of brackets but exclusive of fixing of supply and waste pipe complete all as specified and as directed.
(a) Pillar taps and waste fittings as required shall be measured and paid for under supply only separately.
(b) Supply and waste pipes as required shall be measured and paid for separately.
Supply only pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed of bore of pipe 15mm complete all as specified and as directed.
Make shall be of Prayag Cat No. Neptune Series PIS-02 or equivalent of makes listed here-in-after.
Supply only waste fittings, brass, chromium plated for glazed ware basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed of bore of pipe 32mm complete all as specified and as directed.
Make shall be of Prayag Cat No. Droplet Series BEA-10S or equivalent of makes listed here-in-after.
PVC waste pipes, 32mm bore of pipe, with polyethylene thread union and check nuts, fixed to walls as in waste pipe in wash basin complete all as specified and as directed.
Make shall be of Prayag Cat No.327 or equivalent of makes listed here-in-after.
PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
PVC connections 15mm size with PTMT nuts of length 450mm as in repairs complete all as specified and as directed.
Chromium plated ABS shower rose 105mm size with or without swivel joints, with brass CP 300mm arm including fixing to steel pipe or union complete all as specified and as directed.
Make shall be of Prayag Cat No. Cascade Series BOS-32 (Shower) and BOS-47 (Arm) or equivalent of makes listed here-in-after.
Health faucet, chromium plated, 2 in 1, suitable for 15mm bore of pipe with SS pipe length 1000mm, wall hook, washers, connections, union etc., complete all as specified and as directed.
Make shall be of Parryware Cat No. BEA-97 or equivalent of makes listed here-in-after.
PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of bore 110mm complete all as specified and as directed.
PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of bore 75mm complete all as specified and as directed.
PVC (SWR) floor trap, plain with grating of diameter of outlet 75mm including jointing with solvent cement complete all as specified and as directed.
PVC (SWR) gully trap, 125/110mm with grating including setting and jointing with solvent cement complete all as specified and as directed.
PVC (SWR) bend any radius of bore 110mm complete all as specified and as directed.
PVC (SWR) vent cowl of bore 110mm complete all as specified and as directed.
Rendering 10mm thick in CM(1:3) over levelling course when the concrete is green, mixed with liquid water proofing compound and finished even and smooth without using extra cement complete all as specified and as directed.
Supply only liquid water proofing compound shall be measured and paid separately.
Preparing the rendered surface thoroughly to remove all loose particles, dirt / dust particles and applying a uniform coat of blown grade bitumen VG-10 @ 1.20 kg/sqm conforming to IS 702 over a coat of bitumen primer @ 0.40 Litres / Sqm followed by APP membrane reinforced with polyster non woven fabric 3mm thick weighing not less than 3.6 kg / sqm laid on primed surface by forced application followed by a finishing coat of solar reflective aluminium paint @ 0.10 litres / Sqm complete all as specified and as directed. complete all as specified and as directed.
For detailed specifications please refer particular specifications and list of manufacturers given here-in-after and the rate rate quoted shall include for the same.
Supply only Liquid Water proofing compound all as specified and as directed.
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
SCH "A" PART-III (INTERNAL ELECTRIFICATION)
Point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulated 1100 volts grade unsheathed cable FRLS confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia concealed in walls and fixed on surface with suitable clamps on ceiling etc., and including provision of one 1.5 sqmm PVC insulated single core multistranded copper conductor cable FRLS green in colour as earth continuity conductor and connected to common earth dolly, metal flush box and cover plate with frame for suitable number of modules flush mounted and concealed in walls for housing the switches, socket outlets, fan regulators etc., complete all as specified and as directed for one light point controlled by one switch.
(a) Cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
(b) Metal flush box and cover plate with frame for suitable number of modules shall be measured and paid separately.
All as per BOQ SL No.103 here-in-before but for one ceiling fan point controlled by one switch and regulator
(a) Cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
(b) Metal flush box and cover plate with frame for suitable number of modules shall be measured and paid separately.
All as per BOQ SL No.103 here-in-before but for one exhaust fan point controlled by one switch.
(a) Cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
(b) Metal flush box and cover plate with frame for suitable number of modules shall be measured and paid separately.
All as per BOQ SL No.103 here-in-before but for One switch socket outlet point 3 pin 5 Amps on same board with other switches.
(a) Cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
(b) Metal flush box and cover plate with frame for suitable number of modules shall be measured and paid separately.
All as per BOQ SL No.103 here-in-before but for One switch socket outlet point 3 pin 5 Amps on independent board.
(a) Cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
(b) Metal flush box and cover plate with frame for suitable number of modules shall be measured and paid separately.
All as per BOQ SL No.103 here-in-before but for point wiring with two 4.0 sqmm single core copper conductor multistranded cable and one 4.0 sqmm PVC insulated single core multistranded cable as earth continuity conductor green in colour for one 3 pin switch socket outlet, 15 Amps, on independent board complete all as specified and as directed.
(a) Cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
(b) Metal flush box and cover plate with frame for suitable number of modules shall be measured and paid separately.
Modular switch, one way, 6 Amps, one module complete all as specified and as directed.
Make shall be of Legrand Cat No. 6730 00 or equivalent of makes as listed here-in-after.
Modular switch, one way, 16 Amps, one module complete all as specified and as directed.
Make shall be of Legrand Cat No. 6730 08 or equivalent of makes as listed here-in-after.
Modular socket outlet, 6A-2/3 pin combined, two module complete all as specified and as directed.
Make shall be of Legrand Cat No. 6730 44 or equivalent of makes as listed here-in-after.
Modular socket outlet, 6A / 16A-2/3 pin combined, two module complete all as specified and as directed.
Make shall be of Legrand Cat No. 6730 45 or equivalent of makes as listed here-in-after.
Metal flush box in any number of combinations as required complete all as specified and as directed.
The rate shall be quoted on per module basis irrespective of the number of modules in the combination.
White cover plate with frame in any number of combinations as required complete all as specified and as directed.
The rate shall be quoted on per module basis irrespective of the number of modules in the combination.
Modular Fan step regulator, 120 W, 250V, two module complete all as specified and as directed.
Make shall be of Legrand Cat No. 6730 28 or equivalent of makes as listed here-in-after.
Ceiling rose, 3 terminal, PVC / polycarbonate, insulated body complete as specified and as directed.
Lamp holder, PVC / polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
MCB 6-32 Amps, SPN, 240 Volts, 50 Hz, AC supply, "B" curve, with breaking capacity of 10 kA complete all as specified and as directed.
MCB 6-32 Amps, SP, 240 Volts, 50 Hz, AC supply, "B" curve, with breaking capacity of 10 kA complete all as specified and as directed.
MCB DB SPN 8 way, SPN, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, fixed on wall semi flush with tinned copper bus bar 100 Amps rating , neutral link, earth link and connecting up as in repairs complete all as specified and as directed.
MCB DB SPN 4 way, SPN, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, fixed on wall semi flush with tinned copper bus bar 100 Amps rating , neutral link, earth link and connecting up complete all as specified and as directed.
LED batten fitting 20 W, 230 V, extruded aluminium housing provided for easy heat dissipation wall mounted complete pre wired and including tube and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting with the following parameters,complete all as specified and as directed.
(a) Make shall be Havells Cat No. LUMILINEPLUSBS20WLED865SPCSS or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer Particular Specifications given here-in-after.
LED batten fitting 10 W, 230 V, extruded aluminium housing provided for easy heat dissipation wall mounted complete pre wired and including tube and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting with the following parameters,complete all as specified and as directed.
(a) Make shall be Havells Cat No. LUMILINEPLUSBS10WLED865SPCSS or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer Particular Specifications given here-in-after.
LED building security light fitting 30W made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07, complete pre-wired and connecting up with suitable twin core flexble copper wire including provision of necessary GI tubing medium grade 25mm bore of pipe 1.5m bent to shape with necessary clamps made out of mild steel, nuts and bolts etc., including two coats of synthetic enamel paint over a coat of red oxide primer on exposed steel surface for fixing the fitting to steel tubular poles etc complete all as specified and as directed.
(a) Make shall be as Havells Cat No. ENDURAPEARLSL30WLED757SASYTOPCMP under or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer under Particular Specifications here-in-after.
Energy saving ceiling fan 1200mm sweep, double ball bearing type, opal white colour, with suitable down rod, AC single phase, 240 Volts, 50 Hz and connecting including provision of two way PVC connectors, 1 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan complete all as specified and as directed.
Make shall be of Havells Cat No.Efficiencia Neo or equivalent of makes as listed here-in-after.
Ventilating Fans, 250mm sweep, with plastic body, AC single phase, 240 Volts, 50 Hz and connecting including provision of two way PVC connectors, 1 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan including earthing and fixing arrangements like making hole in wall and finishing to shape to match adjoining surface and writing MES No.20mm height with synthetic enamel paint black complete all as specified and as directed.
(a) Make shall be of Havells Cat No.Ventil Air DX White or equivalent of makes as listed here-in-after.
Earthing complete with galvanised iron earth plate electrode 600mm X 600mm X 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
SCH "A" PART-IV (EXTERNAL ELECTRIFICATION)
Plain cement concrete, type C1, 1:3:6, using 20mm graded granite stone aggregate as in coping of poles, including weathering, slightly rounded or chamfered angles, including necessary formwork complete all as specified and as directed.
Plain cement concrete 1:3:6, type C2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
Dry river sand laid to required width of trench at bottom and top for cable cushioning all as specified and as directed.
Punned thickness only shall be measured.
Common burnt bricks sub class "B" of old size, designation 50, laid dry in trenches with width equal to length of bricks across the cable for cable protection all as specified and as directed.
XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, in trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments of the following sizes complete all as specified and as directed.
(a) Earthwork, sand cushioning, protection for cable etc., as required shall be measured and paid separately.
(b) Lugs and glands shall be used appropriately wherever required while connecting cables to the panel board and the quoted rates are deemed be include for the same.
(a) 4 core, cross sectional area 16 sqmm.
(b) 2 core, cross sectional area 16 sqmm.
(c) 2 core, cross sectional area 10 sqmm.
Wiring with PVC insulated and PVC sheathed cable, copper round conductor of size 3 core, 1.5 sqmm, 1100 volts grade, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories and fixed with suitable clamps complete all as specified and as directed.
Taking up and down steel tubing and connections and taken on credit and provision of Steel tubing, galvanised, light grade, with all fittings such as bends, elbows, tees etc., and laid in trenches / under floor / under roads / crossings etc., of bore of pipe 40mm for cable protection complete all as specified and as directed.
Earthwork as required shall be measured and paid separately.
Steel tubular swaged poles complete with 6mm thick mild steel base plate, finial taper plug, bolts, nuts and screws as specified, type 410, SP-31 (9.00 metres long) and shall be coated with two coats of black bituminous paint throughout internally, and externally up to the planting depth and the remaining, portion of the exterior shall be painted with one coat of red oxide zinc chrome primer complete all as specified and as directed.
Earthwork, PCC foundation, coping etc as required for erection of pole shall be measured and paid separately.
LED street light fittings, with and including lamps, system wattage of 90 Watts, fixture housing with die cast aluminium and individual high power LED as light source and lens embedded PC cover with TOP opening separate driver compartment with IP-66 protection, and impact resistance of IK07 suitably mounting on steel swaged poles on and including bracket made out of GI pipe medium grade 40mm bore of pipe 2m long bent to shape with suitable mild steel clamps duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer prewired with PVC sheathed 2.5 sqmm 3 core copper conductor flexible wire run through 20mm conduit from SMC box to light fitting and fixed with clamps complete all as specified and as directed.
(a) Make shall be Havells Cat No. ENDURAOMNIPLUSSL90WLED757SASYTOPC or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer Particular Specifications here-in-after.
Sheet moulded compound (SMC) box, weather proof type, hinged door, off white colour of size 240mm x 130mm x 110mm comprising MCB SP 6 Amps, 10 kA - 01 No and Neutral link - 01 No fixed on pole with suitable clamps, bolts and nuts duly painted complete all as specified and as directed.
Make shall be Sintex Cat No. GSJB-2817 or equivalent of makes as listed here-in-after.
Cutting existing bituminous road surfaces to a depth not more than 150mm, and making good the surface with PCC 1:3:6, type C1, using 20mm graded stone aggregate to match to the adjacent surface after laying pipes / cable including removal of debris to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
The cubical content of concrete provided to make good shall be measured for purpose of payment.
MONISH CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .