Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-Finance | ₹11.1 L | L1 | Accepted-Finance Responsive |
| 2 | L2₹11.6 L+₹41,425.09 (3.72%)Accepted-Finance | ₹11.6 L+₹41,425.09 (3.72%) | L2 | Accepted-Finance Responsive |
Tender Value
₹12.7 L
EMD Value
₹25,469
Closing Date
30 Aug 2023, 3:00 pmClosed
EE PBSD APWD Port Blair
EE PBSD APWD Port Blair
Widening and resurfacing of road near gate and construction of 02 Nos Sentry Post at rear Gate at Raj Niwas
2023_APWD_11286_1
NIT No.34/EE/PBSD/2023-24
Open Tender
Civil Works - Others
Works
30 days
Raj Niwas Port Blair
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹25,469
6 Sept 2023
16 Aug 2023
30 Aug 2023
16 Aug 2023
30 Aug 2023
16 Aug 2023
Amount
2.5 cm thick bitumastic sheet with hot bitumen of approved quality,using stone chippings (60% with 12.5 mm nominal size and 40%with 10 mm nominal size) @ 1.65 cum per 100 sqm and coarsesand @ 1.65 cum per 100 sqm of road surface and with bitumen @56 kg/cum of stone chippings and @ 128 kg/cum of sand over atack coat with hot straight run bitumen, including consolidationwith road roller of 8 to 10 tonne etc. complete. (tack coat to be paid separately) :
With paving Asphalt grade VG - 30
Providing and applying tack coat using hot straight run bitumen ofgrade VG - 10, including heating the bitumen, spraying the bitumenwith mechanically operated spray unit fitted on bitumen boiler,cleaning and preparing the existing road surface as perspecifications :
On bituminous surface @ 0.50 Kg / sqm
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 40 mm nominal size) in pavements, laid to required slopeand camber in panels as required including consolidation finishingand tamping complete.
Painting road surface marking with adequate nos of coats to giveuniform finish with ready mixed road marking paint conforming to IS: 164, on bituminous surface in white/yellow shade, including cleaningthe surface of all dirt, scales, oil, grease and foreign material etc. complete.
Old work (One or more coats)
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :
a) Float glass panes i) 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
a) For fixed portion i) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Upto 5mm depth and 5 mm width
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying matt finished vitrified tile of size 300x300x9.8mmhaving with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoorfloors such as footpath, court yard, multi modals location etc., laidon 20mm thick base of cement mortar 1:4 (1 cement : 4 coarsesand) in all shapes & patterns including grouting the joints with whitecement mixed with matching pigments etc. complete as per directionof Engineer-in-Charge.
12 mm cement plaster of mix :
1:4 (1 cement: 4 fine sand)
Providing and fixing factory made uPVC glazed/ wire mesh windows/ doors comprising of lead free uPVC multi- chambered frame, sash and mullion/ coupler (wherever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (whereever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia. with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/ mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh/ Glazing of plain/ toughened/ laminated/ double glass unit with/ without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (iii) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 (iv) Sites with structure height more than 20m for all wind speeds.
a) Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. i) Using R2 series with frame (40mm & above) x (40mm & above) & sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 meter).
Providing and fixing in wall lining with ACP sheets of thickness 4mm with necessary fixing arrangement and screws etc. complete
B M SINGH
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .