Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.8 L+₹45,410 (10.4%)Rejected-AOC TAMIL NADU | PUDUKKOTTAI | TAMIL NADU | 613301 | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | MENAKA CONSTRUCTION ENGINEERS | SUSAND AGENCIES |
|---|---|---|---|---|---|
| 1.00 | Charge for cleaning/ servicing the AC air ducts (Area of air duct approximately 381M², various size of the ducts(1.5X1.2 mtr),(1.0X1.0mtr),(0.75 x 0.75 mtr),0.6X0.6mtr),(0.3X0.3mtr) from the air handling unit duct AC plant in unit III located at 18.5mtr floor to the air ducts of control room room ,Electronic panal room, mini conference hall in Unit III UCB located at 13.5mtr floor by cleaning of dust ,deposited particles etc., inside the air duct where ever necessary the air duct to be removed by cutting and removing of the bolt & nuts in flange joints of the air duct s. After cleaning of the all ducts, the air ducts to be refixed in the existing air ducts by providing felt wool, bolt & nuts in flange joints, arresting of air leaks in ducts as per the direction of engineer in charge . Necessary scaffolding arrangement may be provided to carry out above works (the rates inclusive of all consumables like bolt & nuts ,felt wool ,scaffolding arrangements etc) | 381 | M2 | 2,40,030 ₹2,83,235.4 | 2,17,170 ₹2,56,260.6 Lowest |
| 2.00 | Charges for cleaning/ servicing the entire air duct from the Unit - III fan house to 6.6 KV switch gear room located at 4.5mtr floor etc., [approximately total Length 158.7 mtr, Area :451M²] which include the following works.
• Removal of the hangar supports and providing of scaffolding wherever necessary.
• Dismantling of the air duct segments by removing of fasteners lowering the duct segments to ground. • All Air grill were removed from the air duct. • Rectify the damaged air grill's louvers.
• Complete cleaning of all Air ducts with wire brush, air & vaccum cleaning.
• Patch up work of damaged ducts wherever required.
• After completion of entire duct cleaning, reassembling the Air ducts by providing felt cloth, fasteners in flange joints and restoration of hanger supports.
• Arresting of air leak in flange joints of entire air duct. • Painting and refixing the Air Grills in the air duct.
• Disposal of collected dust particles during cleaning operation.
• Removing the scaffolding arrangement after completion of all works. [The rates inclusive of all T & P Hire charges, scaffolding arrangements,
felt wool, bolts, nuts, Paint & consumable etc.,] | 451 | M2 | 2,43,540 ₹2,87,377.2 | 2,20,990 ₹2,60,768.2 Lowest |
Tender Value
Refer Docs
EMD Value
₹4,600
Closing Date
28 May 2025, 2:00 pmClosed
CE/TTPS
O/o CE/TTPS
TTPS Operation Circle MPM II ACP Servicing of Air conditioning system Air ducts in Unit control room, ventilation Air duct of Unit III Fan house to 6.6 KV Switch gear room etc
2025_EB_557954_1
CE/SE/O/TTPS/Spec.No.108/25-26
Open Tender
Miscellaneous Works
Item Rate
30 days
TTPS
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹4,600
Yes
15 Sept 2025
14 May 2025
29 May 2025
14 May 2025
28 May 2025
14 May 2025
Charge for cleaning/ servicing the AC air ducts (Area of air duct approximately 381M², various size of the ducts(1.5X1.2 mtr),(1.0X1.0mtr),(0.75 x 0.75 mtr),0.6X0.6mtr),(0.3X0.3mtr) from the air handling unit duct AC plant in unit III located at 18.5mtr floor to the air ducts of control room room ,Electronic panal room, mini conference hall in Unit III UCB located at 13.5mtr floor by cleaning of dust ,deposited particles etc., inside the air duct where ever necessary the air duct to be removed by cutting and removing of the bolt & nuts in flange joints of the air duct s. After cleaning of the all ducts, the air ducts to be refixed in the existing air ducts by providing felt wool, bolt & nuts in flange joints, arresting of air leaks in ducts as per the direction of engineer in charge . Necessary scaffolding arrangement may be provided to carry out above works (the rates inclusive of all consumables like bolt & nuts ,felt wool ,scaffolding arrangements etc)
Charges for cleaning/ servicing the entire air duct from the Unit - III fan house to 6.6 KV switch gear room located at 4.5mtr floor etc., [approximately total Length 158.7 mtr, Area :451M²] which include the following works. • Removal of the hangar supports and providing of scaffolding wherever necessary. • Dismantling of the air duct segments by removing of fasteners lowering the duct segments to ground. • All Air grill were removed from the air duct. • Rectify the damaged air grill's louvers. • Complete cleaning of all Air ducts with wire brush, air & vaccum cleaning. • Patch up work of damaged ducts wherever required. • After completion of entire duct cleaning, reassembling the Air ducts by providing felt cloth, fasteners in flange joints and restoration of hanger supports. • Arresting of air leak in flange joints of entire air duct. • Painting and refixing the Air Grills in the air duct. • Disposal of collected dust particles during cleaning operation. • Removing the scaffolding arrangement after completion of all works. [The rates inclusive of all T & P Hire charges, scaffolding arrangements, felt wool, bolts, nuts, Paint & consumable etc.,]
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .