Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 CrAdmitted-Finance | ₹3.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.4 Cr+₹72.6 L (19.8%)Admitted-Finance 303 MAHESH NANGIA 303 PRAGATI CHAMBERS RANJIT NAGAR COMMERCAIL COMPLEX RANJIT NAGAR COMMERCIAL COMPLEX | ₹4.4 Cr+₹72.6 L (19.8%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical not qualifying as per NIT SBD |
| 4 | Rejected-Technical 1 20 ASAF ALI ROAD NEW DELHI 110002 | CENTRAL | DELHI | 110002 | - | - | Rejected-Technical not qualifying as per NIT SBD |
| Sl No | Description | Qty | Unit | HITECH ERECTORS PVT. LTD. L2 | Suncity Enterprises L1 |
|---|---|---|---|---|---|
| 1.00Supply, Erection, Testing & Commissioning of Equipments (Construction of 132 KV Transformer Bay) | |||||
| 1.01 | 3 pole, SF6 gas filled, out door Circuit Breaker , including all accessories, auxiliaries and marshalling boxes/Kiosks, (145KV, 1250 Amps of 3 phase,
50 c/s and 31.5KA for 1 second). | 1 | Nos | 7,50,943 ₹7,50,943 Lowest | 11,00,000 ₹11,00,000 |
| 1.02 | 145kV, 50c/s , 2000 Amp, 31.5kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Blades | 4 | Sets | 3,16,541 ₹12,66,164 | 2,34,416 ₹9,37,664 Lowest |
| 1.03 | Single phase, 50 c/s 145KV Current Transformers (1200-600-300/1-1-1-1-1 A or as per site specifications), 31.5KA for one second, rated dynamic
current 100KA(peak), Class A insulation, Burden 20 VAs | 3 | Nos | 2,12,459 ₹6,37,377 | 1,67,440 ₹5,02,320 Lowest |
| 1.04 | 132KV Control and Relay Panel for Transformer bay completely wired including Substation automation supporting IEDs/numerical relays including Differential relay, Directional 3 O/C 1 E/F protection and numerical communicable REF protection relay. | 1 | No | 6,68,894 ₹6,68,894 Lowest | 11,00,000 ₹11,00,000 |
| 1.05 | Single Phase 50 c/s, outdoor metal oxide gapless type, 120KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated accessories, auxiliaries | 3 | Nos | 44,585 ₹1,33,755 Lowest | 47,656 ₹1,42,968 |
| 1.06 | Neutral Current Transformer with Current Rating 1A/5A and VA Burden 15VA | 1 | Nos. | 50,964 ₹50,964 Lowest | 1,73,880 ₹1,73,880 |
| 1.07 | 132KV Post Insulators Solid Core Type, Power Frequency Withstand Voltage 275KVP Dry lightning impulse withstand voltage ± 650 (KVP) | 6 | Nos. | 10,331 ₹61,986 Lowest | 18,676 ₹1,12,056 |
| 1.08 | Galvanised Structures | 25 | MT | 1,15,903 ₹28,97,575 | 1,09,480 ₹27,37,000 Lowest |
| 1.09 | Galvanised Nuts and Bolts | 1.25 | MT | 1,55,593 ₹1,94,491.25 | 1,28,800 ₹1,61,000 Lowest |
Tender Value
₹4.0 Cr
EMD Value
₹8.1 L
Closing Date
14 Sept 2021, 4:00 pmClosed
Executive Engineer, TLMD-VIII, JKPTCL, Jammu
Office of the Executive Engineer, TLMD-VIII, JKPTCL, Ambedkar Chowk, Jammu.
Capacity Augmentation Grid Sub Station Chandak from 1X20 MVA to 2X20 MVA by way of Installation of 20 MVA Transformer, creation of additional 132 KV Transformer Bay, 33 KV Line Bay and other allied works at, 132/33KV Grid Substation Chandak, Poonch.
2021_PDD_135460_1
E NIT no TLMD-VIII/J/14 of 2021-22 dt-20/08/2021
Open Tender
Electrical Works
Turn-key
120 days
chandak
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
Executive Engineer, TLMD-VIII, JKPTCL, Jammu
₹8.1 L
Office of the Executive Engineer, TLMD-VIII, Jammu
29 Sept 2021
24 Aug 2021
16 Sept 2021
24 Aug 2021
14 Sept 2021
1 Sept 2021
31 Aug 2021
Amount
Supply, Erection, Testing & Commissioning of Equipments (Construction of 132 KV Transformer Bay)
3 pole, SF6 gas filled, out door Circuit Breaker , including all accessories, auxiliaries and marshalling boxes/Kiosks, (145KV, 1250 Amps of 3 phase, 50 c/s and 31.5KA for 1 second).
145kV, 50c/s , 2000 Amp, 31.5kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Blades
Single phase, 50 c/s 145KV Current Transformers (1200-600-300/1-1-1-1-1 A or as per site specifications), 31.5KA for one second, rated dynamic current 100KA(peak), Class A insulation, Burden 20 VAs
132KV Control and Relay Panel for Transformer bay completely wired including Substation automation supporting IEDs/numerical relays including Differential relay, Directional 3 O/C 1 E/F protection and numerical communicable REF protection relay.
Single Phase 50 c/s, outdoor metal oxide gapless type, 120KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated accessories, auxiliaries
Neutral Current Transformer with Current Rating 1A/5A and VA Burden 15VA
132KV Post Insulators Solid Core Type, Power Frequency Withstand Voltage 275KVP Dry lightning impulse withstand voltage ± 650 (KVP)
Galvanised Structures
Galvanised Nuts and Bolts
2 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
5 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
7 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
10 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
16 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
19 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
2 Core, 6 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
4 Core, 16 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
4 Core, 6 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
Marshalling kiosk with Kiosk frames mild steel structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0 mm. Frames shall be enclosed in cold-rolled sheet steel of thickness not less than 1.6 mm. Doors and covers shall also be cold rolled sheet steel of thickness not less than 1.6 mm. complete structures shall be rigid, self- supporting, free from flows, twists and bends. Dust and vermin proof construction and shall be provided with a degree of protection of IP: 55, with Copper Bar earthing. Finishing paint on panels shall be of shade 692 (smoke grey) of IS: 5. The inside shall be properly stoved. The paint thickness shall be at least 50 microns.
500mm2 ACSR Moose Conductor (a)Aluminium =54/3.53 mm (b) Steel= 7/3.53 mm overall diameter =31.77mm Approx. Wt. =1998 kg/km ultimate strength = 159.60 KN
Single Tension Fittings For Single 500mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN.
Single Suspension Fittings For Single 500mm2 conductor shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 20mm.
Single Tension Fittings For Twin 500 mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN.
Single Suspension Fittings For Twin 500mm2 conductor shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 20mm.
Disc Insulators 120 KN,Ball & Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected.
Disc Insulators 70 KN,Ball & Socket type, 145mm height and 255mm dia. Creepage total 430 mm and 260 mm protected.
T Clamps 500mm2 /500mm2, made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
T Clamps Twin 500mm2 / Twin 500mm2 , made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
P I Clamps made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
P G Clamps made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
Earth Wire 7/3.15mm
Earthwire Tension Clamps comprise of compression type tension clamp with two ‘D’ shackles, jumper terminals, nuts & bolts and washers etc.slip strength shall not be less than 95% of the ultimate strength of the ground wire. Conductivity shall not be less than corresponding length of GSS ground wire
Cable Trays of size 400mm x 3000mm made of M.S angles 40x40x6mm,40x6 Flat.
Cable Trays of size 300mm x 2500mm made of M.S angles 40x40x6mm,40x6 Flat.
Lugs, Ferrules, Welding Material, Cotton Waste etc
Supply, Erection, Testing & Commissioning of Equipments (Construction of 33 KV Line Bay)
33KV VCB (36 KV, 1250 Amps of 3 phase, 50 c/s and 25KA for 3 sec) outdoor type with all accessories and auxiliaries
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Blades
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing Blades
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with Two Earthing Blades
Single phase, 50 c/s 36KV Current Transformers (800-400-200 /1-1-1 A or as per site specifications) , 25KA for one second, rated dynamic current 25KA(peak), Class A insulation, Burden 20 VA
Single Phase 50 c/s, outdoor metal oxide gapless type, 30KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated accessories, auxiliaries.
33KV Control and Relay Panel for Line/Feeder completely wired including Substation automation supporting IEDs/numerical relays
33KV Post Insulators Solid Core Type, Power Frequency Withstand Voltage 95KVP Dry lightning impulse withstand voltage ± 170 (KVP)
Galvanised Structures
Galvanised Nuts and Bolts
2 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
5 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
8 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
16 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
2 Core, 6 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
4 Core, 6 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
Marshalling kiosk with Kiosk frames mild steel structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0 mm. Frames shall be enclosed in cold-rolled sheet steel of thickness not less than 1.6 mm. Doors and covers shall also be cold rolled sheet steel of thickness not less than 1.6 mm. complete structures shall be rigid, self- supporting, free from flows, twists and bends. Dust and vermin proof construction and shall be provided with a degree of protection of IP: 55, with Copper Bar earthing for 33KV. Finishing paint on panels shall be of shade 692 (smoke grey) of IS: 5. The inside shall be properly stoved. The paint thickness shall be at least 50 microns.
500mm2 ACSR Moose Conductor (a)Aluminium =54/3.53 mm (b) Steel= 7/3.53 mm overall diameter =31.77mm Approx. Wt. =1998 kg/km ultimate strength = 159.60 KN
Single Tension Fittings For Single 500mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN.
Single Suspension Fittings For Single 500mm2 conductor shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 20mm.
Single Tension Fittings For Twin 500 mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN.
Single Suspension Fittings For Twin 500mm2 conductor shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 20mm.
Disc Insulators 120 KN,Ball & Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected.
Disc Insulators 70 KN,Ball & Socket type, 145mm height and 255mm dia. Creepage total 430 mm and 260 mm protected.
T Clamps 500mm2 /500mm2, made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
T Clamps Twin 500mm2 / Twin 500mm2 , made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
Spacers For Twin 500mm2 must be one-piece construction of aluminum alloy of an approved type without any projection, cuts, abrasions etc. or chattering parts and shall conform to IS:10162
P I Clamps made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
P G Clamps made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
Earth Wire 7/3.15mm
Earthwire Tension Clamps comprise of compression type tension clamp with two ‘D’ shackles, jumper terminals, nuts & bolts and washers etc.slip strength shall not be less than 95% of the ultimate strength of the ground wire. Conductivity shall not be less than corresponding length of GSS ground wire
Cable Trays of size 400mm x 3000mm made of M.S angles 40x40x6mm, 40x6 Flat.
Cable Trays of size 300mm x 2500mm made of M.S angles 40x40x6mm, 40x6 Flat.
Lugs, Ferrules, Welding Material, Cotton Waste etc (132KV,33KV side)
Supply, Erection, Testing & Commissioning of Equipments (Installation of Transformer)
3.5 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete.
16 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete.
19 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
Single phase, 50 c/s 132KV Capacitor Voltage Transformers (132/√3) KV/ (110/√3)V, One min power freq withstand 275KVrms
Galvanised Structures
Galvanised Nuts and Bolts
500mm2 ACSR Moose Conductor (a)Aluminium =54/3.53 mm (b) Steel= 7/3.53 mm overall diameter =31.77mm Approx. Wt. =1998 kg/km ultimate strength = 159.60 KN
Single Tension Fittings For Single 500mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN
Single Tension Fittings For Twin 500 mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN.
T Clamps Twin 500mm2 / Twin 500mm2 , made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
T Clamps Twin 500mm2 / Twin 500mm2 , made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
Disc Insulators 120 KN,Ball & Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected.
Supply, Erection, Testing & Commissioning of Equipments (Convertion of 33 KV Line Bay to Transformer Bay)
Single phase, 50 c/s 36KV Current Transformers (1200-600-300 /1-1-1 A or as per site specifications) , 25KA for one second, rated dynamic current 25KA(peak), Class A insulation, Burden 20 VA
Single Phase 50 c/s, outdoor metal oxide gapless type, 30KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated accessories, auxiliaries.
33KV Control and Relay Panel for Transformer Bay completely wired including Substation automation supporting IEDs/numerical relays
500mm2 ACSR Moose Conductor (a)Aluminium =54/3.53 mm (b) Steel= 7/3.53 mm overall diameter =31.77mm Approx. Wt. =1998 kg/km ultimate strength = 159.60 KN
Galvanised Structures
Galvanised Nuts and Bolts
Other allied Works
Dismantling of 20 MVA Power Transformer at Grid Sub Station Draba. Dragging, Loading and Transportation of dismantled Power Transformer along with all accessories for Installation at Grid Sub Station Chandak complete job
Unloading of 20 MVA Power Transformer, dragging to the erection site with Installation, Erection, Testing & Commissioning/Charging of Transformer at Grid Sub Station Chandak with Providing and topping of the Transformer with the Transformer Oil if required complete job.
Dismantling of Structures of CT and Surge Arrestor at 33 KV Line Bay and Erection at new foundation with earthing of the structure/equipment complete job.
Civil Works(construction of 132KV Transformer bay)
Main Duct of Size 1200mm x 1200mm with 6 mm M.S Chequered Trench Covers of size 1300x500 mm
Main Duct of Size 1200mm x 1200mm with 75mm Concrete Covers grade M15 of size 1300x500 mm
Sub Main Duct of Size 600mm x 600mm with 75mm Concrete Covers grade M15 of size 700x500 mm
Tee off Duct: 150mm sand filled HDPE pipes from Sub main to Equipments in the outdoor area
Earth Mat (40mm dia steel bars) as per approved design, Galavanised Iron (75mm x 12mm/ 50mm x 6 mm) risers for Equipment and Structural Earthing
Concreting of yard in 1:3:6 & Laying Of Gravel of 0.10 mts
Laying of 132KV Column foundations (as per Approved Drawing)
Laying of 132KV Isolator foundations (as per Approved Drawing)
Laying of 132KV SF6 Breaker foundations (as per Approved Drawing)
Laying of 132KV CT foundations (as per Approved Drawing)
Laying of 132KV LA foundations (as per Approved Drawing)
Laying of 132KV NCT foundations (as per Approved Drawing)
Laying of Post Insulator foundations (as per Approved Drawing)
Construction of 33 KV Line Bay
Main Duct of Size 900mm x 600mm with 6 mm M.S Chequered Trench Covers of size 500 x 1000 mm
Main Duct of Size 900mm x 600mm with concrete grade M15 of size 500 x1000 mm
Sub Main Duct of Size 600mm x 450mm with concrete grade M15 of size 700x500 mm
Tee off Duct: 150mm sand filled HDPE pipes from Sub main to Equipments in the outdoor area
Earth Mat (40mm dia steel bars) as per approved design, Galavanised Iron (75mm x 12mm/ 50mm x 6 mm) risers for Equipment and Structural Earthing
Concreting of yard in 1:3:6 & Laying Of Gravel of 0.10 mts
Laying of 33KV Column foundations (as per Approved Drawing)
Laying of 33KV Isolator foundations (as per Approved Drawing)
Laying of 33KV VCB foundations (as per Approved Drawing)
Laying of 33KV CT foundations (as per Approved Drawing)
Laying of 33KV LA foundations (as per Approved Drawing)
Laying of 33KV Post Insulator foundations (as per Approved Drawing)
Convertion of 33 KV Line Bay to Transformer Bay
Laying of 33KV CT foundations (as per Approved Drawing)
Laying of 33KV LA foundations (as per Approved Drawing)
Other Civil Works
Laying of Transformer Foundation (as per Approved Drawing)
Providing and Laying of Rail Track (as per Approved Drawing)
Fire protection Wall (as per Approved Drawing)
Concreting of 07 no 33 KV Line Bays in 1:3:6 & Laying of Gravel of 0.10 mts
Concreting of 03 no 132 KV Line Bays in 1:3:6 & Laying of Gravel of 0.10 mts
Laying of 132 KV Column foundation (as per Approved Drawing)
Laying of 33 KV Column foundation (as per Approved Drawing)
Dismantling of existing drain
Construction of Drain (as per Approved Drawing)
HITECH ERECTORS PVT. LTD.
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
SBDNIT14.pdf
Tender Documents • 5.81 MB
BOQ_271685.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .