| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.2 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹84.2 L+₹4.9 L (6.19%)Rejected-Finance MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | L2 | Rejected-Finance Higher bidder | |
| 3 | L3₹85.6 L+₹6.3 L (8.00%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-Finance Higher bidder | |
| 4 | L4₹88.9 L+₹9.6 L (12.2%)Rejected-Finance | L4 | Rejected-Finance Higher bidder | |
| 5 | L5₹95.3 L+₹16.1 L (20.3%)Rejected-Finance 201 CHAURANG HEIGHTS CHS PLOT NO 117 SECTOR 13 KHARGHAR NAVI MUMBAI 410210 | NAVI MUMBAI | RAIGAD | MAHARASHTRA | 410210 | L5 | Rejected-Finance Higher bidder |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
9 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
PROVISION OF POWER SUPPLY 11 KV FOR MAGAZINE AT NAD KARWAR UNDER GE SB KARWAR
2021_MES_448263_1
85433/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
Yes
GE (SB) KARWAR
₹1.6 L
Yes
16 Aug 2021
4 Jun 2021
12 Jul 2021
4 Jun 2021
9 Jul 2021
25 Jun 2021
60 days
Amount
Excavation in trench not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of LT underground cables/GI pipes getting out as in soft /loose soil complete all as specified and as directed.
Returning filling in including spreading levelling watering and well ramming in layer not exceeding 25 cm in soft/loose soil all as specified and as directed.
Removing excavated material/soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and as directed.
Supply, lay dry river sand in trenches for cable protection complete all as specified and as directed. Note : Only punned thickness of sand shall be measured and paid
Supplying and laying unreinforced precast concrete cable cover, class HV Type-1, flat size 300mm x 180mm x 40mm with ISI mark factory made complete all as specified and as directed.
Supplying and laying unreinforced precast concrete cable cover, class LV Type-1, flat size 250mm x 150mm x 40mm with ISI mark factory made complete all as specified and as directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 120 sq mm from MRSS Vajrakosh to proposed CSS all as specified and as directed. Note: Rate is inclusive of HT cable route indicators at a distance of 50 m each.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 120 sqmm all as specified and as directed.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm all as specified and as directed.
Supply and fix cable jointing kit for 1100 V grade cable for indoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3.5 core XLPE, armoured, aluminium conductor cable of size 95 to 120 sqmm all as specified and as directed.
Supply and laying including jointing, testing and commissioning of PVC insulated, armoured, heavy duty, LT UG electric cable with aluminum conductor 1100 volt grade of size 120 sqmm 3.5 core including provision of new lugs, glands etc laid in trenches or fixed on wall/pole or drawn through GI pipe complete all as specified and as directed. Note: 1. Rate is inlcusive of cable gland and cable lugs. 2. Rate is inlcusive of LT cable route indicators at a distance of 50 m each.
Supply and laying including jointing, testing and commissioning of PVC insulated, armoured, heavy duty, LT UG electric cable with aluminum conductor 1100 volt grade of size 95 sqmm 3.5 core including provision of new lugs, glands etc laid in trenches or fixed on wall/pole or drawn through GI pipe complete all as specified and as directed. Note: 1. Rate is inlcusive of cable gland and cable lugs. 2. Rate is inlcusive of LT cable route indicators at a distance of 50 m each.
Supply, installation, commissioning and testing the following Vacume Circuit breaker 11 KV, 3 phase 50 cycle ( 50 HZ) totally enclosed metal clad switch gear panel factory made, powder coated board with indoor vacuum circuit breaker floor mounted with common copper tinned bus bar complete all as specified and as directed.
Note :- Proposed VCB shall be fixed and matched with existing VCB by installing same make or by means of extended adopter box including extended bus bar of same capacity all as required . Rate of extended adopter box including extended bus bar deemed included in quoted rate of proposed VCB(a) One No 800 Amps capacity triple pole metal clad HT control panel totally enclosed extendable pattern air insulated metal clad housing, floor mounting vertically isolated, vermin proof, fully interlocked horizontal draw out type having double isolation features & control device with grounded neutral system and equipped with the following equipment. (i) One set of 3 phase 800 Amps air insulated, tinned copper bus bar with insulated colour coating. (ii) One set of side frame for housing for circuit breaker carriage. (iii) 6 Nos 800 amps isolators plugs. (iv) One set of mechanical interlock and automatic shutter system
(v) One 800 Amp triple pole 350 MVA rupturing capacity VCB with automatic drop out and manually charged and motor operated spring closed mechanism complete with auxiliary switches, truck mounted draw out, vacuum circuit breaker, incorporating mechanical as well as electrical ON/OFF indication, mechanical indication "ON" push button for emergency trip & 30 Volts DC trip coil. (vi) One cable box suitable for reception for 95/185 sqmm HT XLPE 3 core under ground cable 11000 volts pressure. (vii) 03 Nos double wound current transformer dual ratio 150/100/ 5-5 amps for protection and metering having adequate VA burden and accuracy. (viii) One set of 4 Nos LED lamp for indicate ON/OFF/Trip/charging.
(xiv) One set of mechanical interlock and automatic shutter gear. (xv) 230 volts AC single phase 80 watt rated strip heater with switch and thermostat space heating. (xvi) Provision of 30 volts DC tripping system with suitable power pack including, siren/ horn alarm and accept switch and over voltage protecting relay. (xvii) Provision of motor charging with AC motor. (xviii) Inbuild Power pack 30 v dc to be provided with panel at least for 30 minuite Back Up.
Supply, fixing, installing, commissioning and testing 11 KV outdoor type compact sub-station consisting of BIS & BEE Certified 11/0.433 KV, oil type transformer HV, LV panel inside 2 mm thick GI sheet polyurethane metallic painted with all interconnections as per the IEC 62271.202 complete in all respect consisting of following items & as per detailed technical specifications. The CSS shall be fully factory assembled. NO ASSEMBLY AT SITE SHALL BE PERMITTED. MV 11 KV, 630A, 18 kA draw out type Vacuum Circuit Breaker as transformer feeder. Fabrications using 2mm thick CRCA sheet steel, ingress protection IP4X solidly earthened at suitable foundation complete with internal wiring RYB lamps consisting of following :-
(A) Vaccume circuit breaker 11 KV For Incoming Vacume Circuit breaker 11 KV, 3 phase 50 cycle ( 50 HZ) totally enclosed metal clad switch gear panel factory made, powder coated board with indoor vacuum circuit breaker floor mounted with common copper tinned bus bar complete all as specified and as directed. (a) One No 800 Amps capacity triple pole metal clad HT control panel totally enclosed extendable pattern air insulated metal clad housing, floor mounting vertically isolated, vermin proof, fully interlocked horizontal draw out type having double isolation features & control device with grounded neutral system and equipped with the following equipment. (i) One set of 3 phase 800 Amps air insulated, tinned copper bus bar with insulated colour coating. (ii) One set of side frame for housing for circuit breaker carriage.
(iii) 6 Nos 800 amps isolators plugs. (iv) One set of mechanical interlock and automatic shutter system (v) One 800 Amp triple pole 350 MVA rupturing capacity VCB with automatic drop out and manually charged and motor operated spring closed mechanism complete with auxiliary switches, truck mounted draw out, vaccume circuit breaker, incorporating mechanical as well as electrical ON/OFF indication, mechanical indication "ON" push button for emergency trip & 30 Volts DC trip coil. (vi) One cable box suitable for reception for 95/185 sqmm HT XLPE 3 core under ground cable 11000 volts pressure.
(xiii) One No volt coil to trip the VCB on failure of electric supply. (xiv) One set of mechanical interlock and automatic shutter gear. (xv) 230 volts AC single phase 80 watt rated strip heater with switch and thermostat space heating. (xvi) Provision of 30 volts DC tripping system with suitable power pack including, siren/ horn alarm and accept switch and over voltage protecting relay. (xvii) Provision of motor charging with AC motor. (xviii) Inbuild Power pack 30 v dc to be provided with panel at least for 30 minuite Back Up.
(C) OUTDOOR ENCLOSURE : Outdoor type enclosure made of minimum 2.0 mm thick GI/ CRCA MS sheet. The enclosure shall have IP 54 degree of protection for HT & LT switchgear for transformer compartment. The enclosure exterior shall be polyurethane metallic painted. Each compartment will be provided with the door and pad locking arrangement. The compartment illumination lamp with door operated switch shall be provided for each compartment, interconnection between HT switchgear & transformer using XLPE single core cable & interconnection between transformer & LT switchgear using bus bars internal earthing connection. All metallic components shall be earthed to a common earthing point.
(D) Transformer - Distribution transformer stepdown , 11KV/0.433KV , Three Phase complying with IS: 1180/IEC-76(Part-1) 2014 with latest ammanmendts , indoor type double copper wound suitable for 50 Hz system of capacity 315 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side ,Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %. Losses should be confined to the limits specified as follows: :maximum allowable losses at full load (100 % ) & Half Load ( 50 % )shall not be exceeded 1.12 % & 0.79 % Respectively as per GRlHA RATING, Percentage Impedance: 5%. Losses and Impedance are subjected to tolerance as specified in IS 1180.
The transformers should be supplied with first filling of oil confirming to IS 335 .The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028 and comprising with the following standard fittings/Technical specifications : -
(a) Lifting lug for transformer and tank. (b) Earthing terminal rating and diagram plate. (c ) Air release device. (d) Oil filling inlet pipe with plug. (e) Drain outlet pipe with brass gate valve. (f) Conservator tank with oil level indicator (g) Silica jel breather
(j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335. (k) Type of connection Delta/Star (l) Type of cooling: Oil and Natural Air. (m) Vector group:DYN 11. (n) Temperature rise over an ambient of 50 °C maximum. (o) Cable end box on both side for HT/LT cables of suitable size. (p) Provision of thermometer with pocket. (q) Provision of oil and winding temperature gauge. (E) INTERCONNECTION & EARTHING : Internal factory connection between HT switchgear & transformer shall be done using IC x 3 x 95 Sqmm XLPE single core cable & interconnections between transformer & LT switchgear using bus bars. Internal earthing connections. All metallic components shall be earthed to a common earthing point.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.5 meter below normal ground level (with top edge of earth plate not less than 1.75 meter below ground level) connected to GI strip 32x6 mm main earthing lead by means of galvanized bolts, nuts and washers with connected to earth test point & to main switch board /panel etc. all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to equipment/substation/panel etc, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe, complete all as specified and directed. Note : GI earth wire upto 7.5 RM is included in the unit rate quoted.
Supply & Laying GI tubing light grade of size 100 mm with necessary fittings as in cable protection laid in trenches/fixed on wall / floor/road crosssing etc including necessary clamps bolts and nuts and then making surface good complete all as specified and as directed
DURGAI ELECTRICALS
devan enterprises
M/S MANOJKUMAR M NAGARKATTE
Modern Engineering Co
KR POWER INFRA INDIA PVT LTD.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .