Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC KHASRA NO 183 10 SHYAM VIHAR HISAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | ₹1.9 Cr Quoted ₹3.8 L | L1 | Accepted-AOC LOA issued |
Tender Value
₹1.9 Cr
EMD Value
₹3.7 L
Closing Date
11 Jul 2024, 5:00 pmClosed
AMIT GOYAL
ED - Karnal
Construction of Mother and Child Block in District Civil Hospital Distt. Panipat (Pdg. 11/0.433 KV Sub Station and DG set only) Recall
2024_HRY_383832_1
20246B1D33B7 C1F1 4F65 B76F 56EDFCFAA5A4665BAR
Open Tender
Electrical Works
Works
60 days
Panipat
2 documents required · 2 mandatory
₹15,000
₹3.7 L
Yes
13 Dec 2024
27 Jun 2024
12 Jul 2024
27 Jun 2024
11 Jul 2024
27 Jun 2024
Amount
[13.18]Providing and fixing hard drawn steel wire fabric 75 mm X 25 mm rectangular mesh with 3.25 mm dia wire fixed on steel windows of standard rolled sections with 3 mm thick flat iron cover moulding of 12.5 mm width fixed with machine screws welded complete in all respect.
[13.2]Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
[20.62.2]Providing, lowering, laying, cutting (cut surface to be uniformly finished), jointing with rubber rings marked with IS : 5382 and testing of SPIGOT AND SOCKETTED RCC, NP2 MARKED WITH IS : 458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete is all respects to the satisfaction to the Engineer - in -charge. 2. 250 mm i/d
[23.26.1]SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages.
[23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages.
[23.26.4]SAFETY ITEMS 4. Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6x4 made of GI pipe 32mm dia).
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.
[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.
[24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.
[24.2.7.1]LT CABLE 7.1. Supply and erection of suitable compression type brass cable glands for underground Cable :- Up to 6 Sq mm cable 2 to 4 Core
[24.2.7.2]LT CABLE 7.2. Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core
[24.2.7.3]LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core
[24.2.7.5]LT CABLE 7.5. Supply and erection of suitable compression type brass cable glands for underground Cable :- 120 sqmm to 185 sqmm Cable 3 to 32 Core
[24.2.7.6]LT CABLE 7.6. Supply and erection of suitable compression type brass cable glands for underground Cable :- 240 sqmm to Cable 3 to 32 Core
[24.2.7.7]LT CABLE 7.7. Supply and erection of suitable compression type brass cable glands for underground Cable :- 300 sqmm to 400 sqmm Cable 3 to 3½ Core
[24.2.8.10]LT CABLE 8.10. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 120 sqmm
[24.2.8.11]LT CABLE 8.11. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 150 sqmm
[24.2.8.12]LT CABLE 8.12. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 185 sqmm
[24.2.8.13]LT CABLE 8.13. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 240 sqmm
[24.2.8.14]LT CABLE 8.14. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work.300 sqmm
[24.2.8.15]LT CABLE 8.15. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 400 sqmm
[24.2.8.3]LT CABLE 8.3. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 10 sqmm
[24.2.8.5]LT CABLE 8.5. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 25 sqmm
[24.2.8.6]LT CABLE 8.6. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 35 sqmm
[24.2.8.7]LT CABLE 8.7. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 50 sqmm
[24.2.8.8]LT CABLE 8.8. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 70 sqmm
[24.3.3.2]HT CABLE 3.2. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :150 to 185 sqmm
[24.3.4.2]HT CABLE 4.2. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 150 to 185 sqmm
[24.5.2.5]MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 120/105 mm outer dia/ inner dia
[24.5.2.7]MISCELLANEOUS ITEMS 2.7. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 180/150 mm outer dia/ inner dia
[24.7.6]RCC FOUNDATIONS FOR DG SET 6. 400 KVA DG Set
[24.7]RCC FOUNDATIONS FOR DG SET "Providing RCC foundation of M20 grade (1 Cement:1.5 Stone aggregate: 3 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 50 kg/cum of concrete contents, concrete cover 50mm, over a bed of 75mm thick PCC 1:5:10, of required dimensions as per OEM recommendations to provide levelled surface for placement of the DG set complete in all respects and as per directions of Engineer-in-charge (Size of foundation assumed = 5.0x1.8x1.0m)" Unit: per cum
[25.1.2]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 2. 250 mm dia
[25.2]Extra for Supplying and fixing of insulation on following nominal dia pipes with FR quality expanded polystyrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500 g polythene faced hessian and then applying 0.6 mm aluminium sheet cladding complete with felt strip at joints repairing etc. as per specifications and as required complete in all respect..
Supply and erection of 25 Sqmm. 04 core under ground aluminum Ard. cable including Laying of underground cable 0.75 metre below ground level covered with sand and bricks including excavation and refilling of trenches complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
Supply and erection of 70 Sqmm. 3.5 core under ground aluminum Ard. cable including Laying of underground cable 0.75 metre below ground level covered with sand and bricks including excavation and refilling of trenches complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
Supply and erection of 120 Sqmm. 3.5 core under ground aluminum Ard. cable including Laying of underground cable 0.75 metre below ground level covered with sand and bricks including excavation and refilling of trenches complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
Supply and erection of 240 Sqmm. 3.5 core under ground aluminum Ard. cable including Laying of underground cable 0.75 metre below ground level covered with sand and bricks including excavation and refilling of trenches complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
Supply and erection of 300 Sqmm. 3.5 core under ground aluminum Ard. cable including Laying of underground cable 0.75 metre below ground level covered with sand and bricks including excavation and refilling of trenches complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
Supply and erection of 06 Sqmm. 04 core under ground aluminum Ard. cable on surface/ cable tray / pipe / trench etc. complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
Supply and erection of 10 Sqmm. 04 core under ground aluminum Ard. cable on surface/ cable tray / pipe / trench etc. complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
Supply and erection of 16 Sqmm. 04 core under ground aluminum Ard. cable on surface/ cable tray / pipe / trench etc. complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
Supply and erection of 25 Sqmm. 04 core under ground aluminum Ard. cable on surface/ cable tray / pipe / trench etc. complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
Supply and erection of 35 Sqmm. 04 core under ground aluminum Ard. cable on surface/ cable tray / pipe / trench etc. complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
Supply and erection of 50 Sqmm. 3.5 core under ground aluminum Ard. cable on surface/ cable tray / pipe / trench etc. complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
Supply and erection of 70 Sqmm. 3.5 core under ground aluminum Ard. cable on surface/ cable tray / pipe / trench etc. complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
Supply and erection of 120 Sqmm. 3.5 core under ground aluminum Ard. cable on surface/ cable tray / pipe / trench etc. complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
Supply and erection of 240 Sqmm. 3.5 core under ground aluminum Ard. cable on surface/ cable tray / pipe / trench etc. complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
Supply and erection of 300 Sqmm. 3.5 core under ground aluminum Ard. cable on surface/ cable tray / pipe / trench etc. complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
Supply and erection of 400 Sqmm. 3.5 core under ground aluminum Ard. cable on surface/ cable tray / pipe / trench etc. complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
S/I/T/C of DG exhaust pipe sport structure made of Angle iron 100x50x6 duly groted in RCC foundation (the design of structure will be got approved from structure design consultant before fabrication / installation) Complete structure duly painted in all respect including cost of foundation and erection. Make Tata / Jindal / SAIL
S/I/T/C of SS bellow for DG exhaust system 250 mm dia complete with necessary inlet and outlet connection duly sealed complete in all respect.
Erection only of old 1600 KVA Crompton make transformer on existing foundation with on load tap changer including dehydration filteration, top-up of oil. Necessary connection of incomming and outgoing cable including supplying, laying connecting contol cable from RTCC / AVR panel to OLTC, bucholz relay to VCB, WTI / OTI to VCB etc. including necessary earth connection,including painting testing and commissioning up to the entire satisfaction enginer in charge for the work.
Supply and Erection of OEM Manufactured APFC Panel 650 KVAR @ 440V. The stage ratings shall be 1 x 10 KVAR plus 1x 15 KVAR plus 3 X 25 KVAR plus 5 X 50 KVAR plus 3 X 100 KVAR, The APFC Panel shall be fully type tested at an Independent Laboratory and shall comply to IEC 61439-1 and IEC 61921. The APFC Panel shall be (Indoor) type, weather, dust and vermin proof suitable for humidity up to 95%. Average daily temperature: plus 35°C max, Ambient temperature: -5°C to 40°C, Maximum altitude: 2000 m. Approved Makes- ABB, Schneider,Legrand As equipment shall be comprising of the following:-` (A) Insulated bus bar assembly made from Aluminium and rated of 1200 Amps capacity. The short circuit withstand capacity shall be 50 KA / 1 Sec ( Icw) for the main bus bar and the rated impulse withstand voltage shall be 6 KV. ( B) The incomer of the APFC Panel shall be a 1200 Amp, ACB, 3P, 50kA with O/L and S/C protection, Ics = 100% Icu, spreaders, phase barrier. . Make:- Schneider Electric / ABB / Legrand / LandT / or their chanel partner. (C) Capacitor Units : The capacitor unit shall be metalized polypropylene film with Zn / Al alloy. The capacitors shall be encapsulated in an aluminium can. The capacitor unit shall have a rated voltage of 440V and shall have a maximum over current capacity of : 1.8 In. The capacitor unit shall have a built in 3 phase over pressure protection and shall have discharge resistors ( 50V in 1min ) factory fitted and shall be tamper proof. Capacitance Tolerance -5%, plus 10%. Maximum permissible over voltage 1.1 x Un, 8 h every 24 h. The capacitor unit shall be of certified design confirming to IS-13340-1993,13341-1992 and IEC -60831-1and2. Make – Schneider Electric / ABB / Legrand / LandT. (D) Short-circuit and Overload Protection : Each stage of the APFC Panel shall have a suitably rated MCCB for short-circuit and overload protection, capacitor duty contector, Indicating Lamp, Push button, Auto manual switch. The over-current setting shall be adjustable and Breaking capacity Ics=) 36kA . The ACB shall be of certified design confirming to IEC Make:- Schneider Electric / ABB / Legrand / LandT (E) PF Regulator : Advanced Range PF Regulator shall have suitable steps with a LCD Display, Voltage Range : 90V - 550V, 50 / 60Hz, CT Input : 1A/5A with a built in RS 485 communication port. The PF Regulator shall be of certified design confirming to IEC 61326. Make : Schneider Electric / ABB / Legrand / LandT (F) Stage Contactor and reactor : The electromagnetic contactors shall be rated for 660 Volts and shall be 3-pole type and shall be employed for switching `on` and switching `off` operations in capacitor banks. Supply to capacitor should be through 7% Aluminium wound detuned reactorThe rated voltage of control coil shall be 415V (phase-to-phase). This voltage is subject to a variation of ( plus ) 10% and (-) 15%. The contactor shall be AC3b type. The contactor shall be of certified design confirming to IEC 60947-1 and 4-1. Make – Schneider Electric / ABB / Legrand / LandT. `(G) Ventilating fans of required size shall be sued to dissipate the heat produced by the capacitor bank components like the capacitor units, reactors, contactors, breakers etc. The capacitor banks should be of type tested design and temperature rise test report of the capacitor bank performed at an independent laboratory should be submitted along with the offer. `
`Supply, installation, testing and commissioning of Indoor cubical type main LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel as per IEC 61439-1and2 with aluminum bus bar 1600 A.The Panel shall have arrangement of connection with cables and to be installed on new suitable foundations with proper provision of incoming and outgoing LT Cables i/c providing following switch gears :-The switchboard shall be factory manufactured Panel shall have top and bottom Entry/Out going type. including Supply, Installation, testing and commissioning of Inert type Novec-1230/FM200 or equivalent Fire Detection Tube based Gas suppression system for electrical panel. It includes all the require accessories/equipments to complete the panel protection, as per detail specification and as perdirection of Engineer in Charge. Every Cable alley compartment of Panel shall have wired or wireless overheating sensors for cable with alarm system. Incomming Feeder Transformer- I :- 1 No. 1 No. 1600A FP EDO ACB Icw=50kA for 1 sec ,Microprcoessor based release with O/C, S/C and E/F Protection, 4 Nos. plus 04 NC Aux. contact charging motor 230 VAC, S/T release 230 VAC, Clossing 230 VAC microswitch. With Aux. Trip contact for ACB, Under voltage Coil 240 VAC, Mechnical key interlooking kit, Break control switch 16 Amp. with digital VAF meter class-I 96 x 96 Sq.mm. with 4 Nos. CTs 1600/5A Class I CMCT for metering with 4 Nos. CT shorting terminal link with 2 Nos. On/ Off indicating lamp LED light with 3 Nos. R/Y/B phase indicating lamp LED type with 4 nos. 6 Amp SPMCB 10 KA for Control circuit with 6 AMP Netural link drop out type for Control circuit. Incoming feeder Transformer - II :- 01 Nos. 1 No. 1600A FP EDO ACB Icw=50kA for 1 sec ,Microprcoessor based release with O/C, S/C and E/F Protection, 4 Nos. plus 04 NC Aux. contact charging motor 230 VAC, S/T release 230 VAC, Clossing 230 VAC microswitch. With Aux. Trip contact for ACB, Under voltage Coil 240 VAC, Mechnical key interlooking kit, Break control switch 16 Amp. with digital VAF meter class-I 96x96 Sq.mm. with 4 Nos. CTs 1600/5A Class I CMCT for metering with 4 Nos. CT shorting terminal link with 2 Nos. On/ Off indicating lamp LED light with 3 Nos. R/Y/B phase indicating lamp LED type with 4 nos. 6 Amp SPMCB 10 KA for Control circuit with 6 AMP Netural link drop out type for Control circuit. Buscoupler Feeder :- 01 Nos. 2500A 4P EDO ACB 50KA With Microprocessor Based Release For {O/C, S/C and E/F} Protection, 4NO plus 4NC Aux. Contacts, Charging Motor-230Vac, S/T Release-230Vac, Closing Coil-230Vac, Micro Switch. With 1 Nos. Aux Trip Contact for ACB, Under Voltage Coil 240 Vac,Mechanical Key Interlocking Kit, Breaker Control Switch, 16A, with 2 Nos. On/ Off indicating lamp LED light with 3 Nos. R/Y/B phase indicating lamp LED type with 4 nos. 6 Amp SPMCB 10 KA for Control circuit with 6 AMP Netural link drop out type for Control circuit Bus Section -I 1 Nos. 1250 Amp. FP MDO ACB 50 KA with micro processor based released for O/C, S/C protection. 1 No. 800A FP MCCB 50KA with thermal magnetic release for O/C, S/C protection with extended rotary handle. 1 Nos.100 AMP 4 Pole MCCB 25KA with thermal magnetic release for O/C, S/C protection with extended rotary handle and 2 Nos. spreader terminal .4 Nos.63 AMP 4 Pole MCCB 25KA with thermal magnetic release for O/C, S/C protection with 4 Nos. extended rotary handle and 8 Nos. spreader terminal Bus Section -II 1 Nos. 1250 Amp. FP MDO ACB 50 KA with micro processor based released with display for O/C, S/C and E/F protection. 1 No. 800A FP MCCB 50KA with microprocessor based release for O/C, S/C and E/F protection . 1 Nos.100 AMP 4 Pole MCCB 25KA with thermal magnetic release for O/C, S/C protection with extended rotary handle and 2 Nos. spreader terminal. 01 Nos.63 AMP 4 Pole MCCB 25KA with thermal magnetic release for O/C, S/C protection with 01 Nos. extended rotary handle and 02 Nos. spreader terminal BUS BAR - Main Bus Bar ` `Copper Bus busbar made from Electrical Grade, Copper flats (E-91-E) 2000 AMP Duly supported and on DMC insulators and covered with heat shrinkable sleeves Enclosure, Bus Bar and Wiring and Accessories MS Cabinet with integrated Base Frame and Powder Coated Paint,Hardware and Accessories - Nuts, Bolts, Washers, Door Hinges and Locks, Neoprene Rubber Gaskets,Mounting Plates, MS Channels, Partitions, Lifting Hooks and Gland Plates, PVC Wires, Ferrules Thimbles and Other Wiring Accessories, Consumables, Design and Development, Drawings Manufacturing Cost i.e. Fabrication, Painting, Bus Bar, fitting, Handling and fitting of switchgears.`
Supply, installation, testing and commissioning of DG outgoing panel for Indoor cubical type suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel as per IEC 61439-1and2 with aluminum bus bar 800 A. The Panel shall have arrangement of connection with cables and to be installed on new suitable foundations with proper provision of incoming and outgoing LT Cables i/c providing following switch gears :-The switchboard shall be factory manufactured Panel shall have top and bottom Entry/Out going type. including Supply, Installation, testing and commissioning of Inert type Novec-1230/FM200 or equivalent Fire Detection Tube based Gas suppression system for electrical panel. It includes all the require accessories/equipments to complete the panel protection, as per detail specification and as perdirection of Engineer in Charge. Every Cable alley compartment of Panel shall have wired or wireless overheating sensors for cable with alarm system Approved Makes- MCCB/ switch gear = LandT, Schneider, Siemens, ABB. Incomer (From 400KVA DG AMF) 600A 4 P MCCB (a) 3 Nos.- RYB PHASE INDICATING LIGHT, 230V AC with each Incomer (b ) 3 Nos.-ON/OFF/TRIP INDICATING LIGHT, 230V AC with each Incomer (c) 3 Nos. CT FOR METERING, 1600/5A , CL-1.0, 15VA (d) 1 Nos. DIGITAL Multifunction Meter (IV,KW,KWH,KVA,PF,HZ Maximum Demand with LCD Display), 96mm square flush pattern with RS485 with each Incomer (e) CONTROL MCB, 2A SP, 10KA OUTGOINGS: `1 Nos. 400A FP MCCB Ics= 50kA thermal magnetic type with variable overload MCCB shall be Double break type for main building light panel. ` `2 No. 100A TP MCCB Ics=35kA thermal magnetic type (For X-Ray and spare)` `1 Nos. 63A FP MCCB Ics=35kA thermal magnetic type with variable overload. MCCB shall be Double break type. (For MGPS) ` `3 Nos. 40A FP MCCB Ics=35kA thermal magnetic type with variable overload. MCCB shall be Double break type. (For water supply, ELV service, blood bank) ` complete panel including all hardware, wiring termination etc., installed at site up to entire satification of engineer in charge.
Supply and erection of stay set with stay wire suitable for 9M long PCC pole made out of 7/3 SWG GI wire with U type M.S. Rod 5/8` dia duly threaded by means of angle iron of size 50 x 50 x 6 mm x 30 cm 6 feet long M.S. Rod buried in ground after fixing with cross channel size 75 x 40 x 6 mm x 60 cm long the stay wire will be binded on the top of the pole with help of suitable size of double U type M.S. Clamps and stay fixed with nuts and bolts the stay wire shall be insulated in the middle point with the help of egg insulator including all labour and material required to complete the job in all respect to the entire satisfaction of Engineer- in -charge of work.
`Supply and erection of prestressed cement concrete pole as per IS : 1678-1960. 9 metres long 105 mm x 115 mm at top and 105 mm x 315 mm at bottom with working load of 200 Kg. burried 1.80 m in ground. (Make and specification as per UHBVNL/DHBVNL) including Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1 :3:6) layer on top with including excavation and refilling etc as required (As per HSR 24.4.10.4.)
Supply and Erection of rubber mat of size 1M x 2 M X 12 mm thick suitable for 11 KV ISI marked complete in all respect up-to the entire satisfaction of the engineer In-charge of the work.
Supply and Erection of fire bucket of 9 ltr. capacity made out of 24guage G.l. sheet and duly painted with one coat of red oxide and 2 coats of approved paint in red colour and written with the fire` as per fire protection necessary sand filling in the bucket hung the bucket on stand with all labour and material required to complete the job all respect up to entire satisfaction of the Engineer m charge of the work
Supply and erection of ACSR conductor (ISI Marked) with accessories including stringing and sagging of conductor of various sizes as well as jointing and binding with insulator at support complete in all respect up to entire satisfaction of Engineer-in-charge of the work. ACSR Cond. 50 Sq.mm. (Make and specification as per UHBVNL/DHBVNL).
Supply stringing and sagging of GSL wire 8 SWG complete in all respect with erection of the same up-to the entire satisfaction of the Engineer in Charge of work (Make and specification as per UHBVNL/DHBVNL)
Supply and erection of MS channel 100x50x6mm including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect up-to the entire satisfaction of Engineer-in-charge. (Make and specification as per UHBVNL/DHBVNL)
Supply and erection of MS angle 50x50x6mm including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect up-to the entire satisfaction of Engineer-in-charge. (Make and specification as per UHBVNL/DHBVNL)
Supply and erection of MS flat 50x6mm including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect up-to the entire satisfaction of Engineer-in-charge. (Make and specification as per UHBVNL/DHBVNL)
Providing and fixing of Nut and Bolt of size as per ISI specification of Engineer-in-charge. (Make and specification as per UHBVNL/DHBVNL)
Supply and erections of V-shape X-arm on PCC poles as per state electricity Nigam design and requirement it should be made out of MS channel size 100x50mm 13.200 Kg complete in all respect . (Make and specification as per UHBVNL/DHBVNL)
Supply and erection of 11KV GI pin insulator with pin Rashtriya / Jayshree / BHEL make with pin with all labour and material required to the complete the job included the fixing the same on existing channels up to entire satisfaction of the Engineer-in-Charge of the works. (Make and specification as per UHBVNL/DHBVNL)
Supply and erection of 11KV gang operated switch Rashtriya / Jayshree / BHEL make conforming to IS with latest amendment including suitable size of copper blade erection of same on the existing `H`pole with the help of 3 Nos. channels of size 75mmx40mmx6mm, 1.8M long fixed with suitable size of MS clamp, nuts and bolts including cost of 6 Nos. 11KV insulator with GI pin, RD fuses and painting with 2 coat of approved paint and one coat of red oxide material required to complete the job in all respect up to entire satisfaction of the Engineer-in-Charge of the works. (Make and specification as per UHBVNL/DHBVNL)
Supply Erection Testing and Commissioning of 11kV indoor HT metering panel indoor / outdoor complete with C.Ts P.Ts Cubical .as per requirement / approved by DHBVNL consisting of the following. - Cubical panel free standing floor mounting type made out of sheet steel 16 SWG CRCA sheet with channel iron base frame spray painted with strong synthetic light grey enamel paint as per size and design approved by the DHBVNL. - 3 Nos. 11KV CTS of rating as approved by DHBVNL for indoor installation of approved make of DHBVNL. - 1 Nos. 11KVPTS 11000/10 VA burden 0.5 accuracy oil filled suitable for indoor installation of approved make of DHBVNL. The cubical panel will be completed in all respect including inter connection, internal wiring with PVC copper cable, modem and allied accessories its testing and approval of all item by DHBVNL cost of all testing/ approval charges or all items of DHBVNL with a guarantee of one year from the date of commissioning. including cost of all labour and material required to complete the job in all respect up-to the entire satisfaction of the engineer in charge of the work
Supply and Erection of Digital Electronic Trivector Meter 3 phase 4 wires 0.5 accuracy for recording reading in KWH / KVARH / KVAH of make and rating approved by DHBVNL with push button display operating system for different kind of readings suitable for dual metering including cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the engineer in charge of the work. (Make and specification as per UHBVNL/DHBVNL)
Supply of Disc insulator Rashtriya / Jayshree / BHEL make with Disc fitting TandC type complete in all respect with erection of the same upto the entire satisfaction of the Engineer in Charge of work (Make and specification as per UHBVNL/DHBVNL)
Providing and fixing of 11 KV oil cooled CT/PT combined unit ratio 40/5 A.C 0.5 (5) VA 5 and PT ratio 11/110 volt AC 0.5 VA / 0 along with metering cubical etc. fixing on H. pole metering cubical wiring with plate form required to complete the job in all respect upto the entire satisfaction of the engineer in charge of the work as per approved make of UHBVNL for dual metering. (Make and specification as per UHBVNL/DHBVNL)
Supply and erection of lighting arrestor model ALPRO / Alastem / LEMCO make suitable for 11KV 3 Phase 50 HZ ground neutral system comprising of spare gape type queen gap type in series with non linger resitar element house in Horizontally scale poreclam bushing with line and ground terminal along with mounting clamps conforming to ISS 3070 (Part-I) of 1985 with latest amendment with all labor and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works.
`S/E of XLPE (E)11 KV HT aluminum conductor armoured cable ISI mark laid in existing pipe /trenches/surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work including Laying and erection of XLPE II kv HT aluminium conductor armoured cable ISi mark laid on surface/ pipe/cable tray duly tide and hanged on the existing PCC poles with required hardware, wooden supports etc., including with all labour and material as required up to 120 sqmm 3 core XLPE Cable (As per HSR 24.3.2 Make RR / Havells / Polycab/KEI. 185 sqmm 3 core XLPE Cable `
Providing and fixing earth bus of 50 mm x5 mm copper strip on surface for connection etc. as required. DSR 5.20
Supply. Installation testing and commissioning of 4 Core x 1.5 Sq.mm Copper wire( PVC insulated and PVC sheathed, flexible, copper conductor of 1.1 KV grade on existing cable trays) as per specification standard
Supply and erection of 50 Sqmm. 3.5 core underground aluminum Ard. cable including Laying of underground cable 0.75 metre below ground level covered with sand and bricks including excavation and refilling of trenches complete with necessary connections complete in all respect up-to the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .