Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹13.0 L+₹50,053 (4.02%)Rejected-Finance AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹13.9 L+₹1.5 L (12.0%)Rejected-Finance KOIL KOIL PULWAMA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹14.4 L+₹2.0 L (15.9%)Rejected-Finance 184 TENGPUNA PULWAMA PULWAMA PULWAMA JAMMU KASHMIR 192301 UDYAM JK 15 0009999 | PULWAMA | JAMMU AND KASHMIR | 192301 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹14.4 L+₹2.0 L (15.9%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹20 L
EMD Value
₹20,000
Closing Date
3 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR, 8 FBSU, AF AWANTIPUR
REPAIRS TO INTERNAL ELECTRIFICATION, MCBs, DBs IN MARRIED ACCN AT 8FBSU
2023_MES_585597_1
GE (AF) AWA-41/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (AF) AWANTIPUR
₹20,000
Yes
29 Apr 2023
13 Mar 2023
5 Apr 2023
13 Mar 2023
3 Apr 2023
28 Mar 2023
Amount
Taking down carefully aluminium/copper point wiring (light, bell, fan, socket) complete including batten/casing caping/conduit, block, ceiling rose, holder, fittings and terminal box sheets complete, stacking material at site and making good the disturbed surface of walls/ floors to match with existing surface, complete all as specified and directed.
Point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm in and including PVC casing caping, ISI marked with all connected accessories including one single core multistanded PVC insulated FRLS type, 1.5sqmm copper conductor cable unsheathed as earth continuity cable including concealed pressed steel GI terminal boxes 1.5mm thick with 3mm thick laminated sheet cover for mounting of switches, socket, fan regulators, complete all as specified and directed for the following:-
(a) One light /fan/bell point controlled by one No, one way 5/6 Amps switch.
(b) One 3/5 pin socket outlet, 5/6 Amp controlled by one No, one way switch on same board.
(c) One 3/5 pin socket outlet, 5/6 Amp, independent, controlled by one No. one way switch on independent board.
Description all as per serial item No. 2 here-in-before, but using cable of size 2.50sqmm (for phase & neutral) and 2.5sqmm as continuous earth cable for 15/16 Amps socket outlet independent point on independent board, complete all as specified and directed.
Piano type switch one way, SP, flush type, 5/6 Amps, 230 volts AC, 50 Hz in replacement, complete all as specified and directed.
Piano type bell push switch, one way, SP, flush type, 5/6 Amps, 230 volts AC, 50 Hz in replacement, complete all as specified and directed.
Piano type socket outlet, flush type, 5 pin, 5/6 Amps, 230 volts AC, 50 Hz , multipurpose type, in replacement, complete all as specified and directed
Piano type switch socket combination, flush type, 6 pin, 5/15 Amps, 230 volts AC, 50 Hz, multipurpose type in replacement, complete all as specified and directed.
Electronic type ceiling fan regulator, 230 volts, single phase, flush type in replacement, complete all as specified and directed.
Ceiling rose 3 terminals, PVC/polycarbonate/bakelite, isolated body, 230 volts AC, 50 Hz in replacement, complete all as specified and directed.
Electric call bell, ding dong type suitable for 230 volts, single phase AC in replacement, complete all as specified and directed.
Electric call bell in replacement, ding dong type suitable for 230 volts,remote controlled alongwith bell push and range upto 15metres for single phase AC supply, complete all as specified and directed.
Polycarbonate/PVC batten holder in replacement with cord grip,B-22 base type suitable for and including 7 watt LED bulbs, 230 volts AC 50 Hz, complete all as specified and directed.
Replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4sqmm complete drawn in and including casing caping ISI marked of suitable size and its accessories along with 1x 4sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and directed. Note :- 2 +1 run of 4Sqmm cable including casing caping of suitable size shall be measured as one running metre.
Replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 6sqmm complete drawn in and including casing caping ISI marked of suitable size and its accessories along with 1x 6sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and directed. Note :- 2 +1 run of 6Sqmm cable including casing caping of suitable size shall be measured as one running metre.
Replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 10sqmm complete drawn in and including casing caping ISI marked of suitable size and its accessories along with 1x 10sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and directed. Note :- 2 +1 run of 10Sqmm cable including casing caping of suitable size shall be measured as one running metre.
Replacement of existing DB's double door sheet metal enclosure with IP-43, IK-09 protection with new factory made DB's double door made out of CRCA mild steel sheet with insulating material like polyester epoxy quoted surface mounting 4 way TPN 415 volts, vertical type, surface mounting with suitable busbar, neutral link and earth link suitable for MCCB TP as incomer and MCB SP/TP as out going complete with and including one No. MCCB 100 Amps, 3 pole, 25 kA fixed type for incoming, complete all as specified and directed.
Replacement of existing Sheet metal enclosure IP-43, IK-09 protection DB with new Sheet metal enclosure DB TPN 4 way, double door, 415 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB TP/TPN as incomer and MCB SP as outgoing, complete all as specified and directed.
Replacement of existing Sheet metal enclosure IP-43, IK-09 protection DB with new Sheet metal enclosure DB SPN 8 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB DP/SPN as incomer and MCB SP as outgoing, complete all as specified and directed.
Replacement of existing Sheet metal enclosure IP-43, IK-09 protection DB with new Sheet metal enclosure DB SPN 12 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB DP/SPN as incomer and MCB SP as outgoing, complete all as specified and directed.
Replacement of existing Sheet steel plug & socket DB's with new Sheet steel plug & socket DB's SP with metal clad 2 pin & earth plug and socket SPN, 20 Amps, 230 volts AC, concealed type, complete with & including one MCB SP, 20 Amps, 10 kA, including grouting in wall and making good to disturbed surfaces to match existing, complete all as specified and directed.
MCB SP, 6-32 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type, fixed in repair, complete all as specified and directed.
MCB SPN, 40-63 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type,fixed in repair, complete all as specified and directed.
MCB TPN, 40-63 Amps, 415 volts, 10 kA rupturing capacity, 'C' curve type, fixed in repair, complete all as specified and directed.
Replacement of MCCB TP 100 Amp, 25 KA, 415 V microprocessor LSIG energy release complying with IEC 60947-2 frame size P 160 microprocessor trip unit with LSIG protection, OLED diplay, multifunction metering with accuracy class 0.5 for V&I adjustable overload with delay/short circfuit with adjustable/ Ground Fault/ Instantaneous 12T On/Off for precise coordination. ZSI for intelligent discrimination, alarm management systen complete all as specified and directed.
Decorative laminated sheets 3mm thick of size 10''X12'' including necessary cutting of sheet for fixing switch/socket, fixed in repairs, complete all as specified and directed.
Decorative laminated sheets 3mm thick of size 8''X10'' including necessary cutting of sheet for fixing switch/socket, fixed in repairs, complete all as specified and directed.
Decorative laminated sheets 3mm thick of size 7''X4'' including necessary cutting of sheet for fixing switch/socket, fixed in repairs, complete all as specified and directed.
Decorative laminated sheets 3mm thick of size 4''X4'' including necessary cutting of sheet for fixing switch/socket, fixed in repairs, complete all as specified and directed.
PVC 3 modular gang box with cover plate of suitable module, fixed in repairs, complete all as specified and directed.
PVC 4 modular gang box with cover plate of suitable module, fixed in repairs, complete all as specified and directed.
PVC 6 modular gang box with cover plate of suitable module, fixed in repairs, complete all as specified and directed.
Replacement of FRLS PVC insulated unsheathed multi-core stranded copper conductor 2.5 sqmm, 3 core LT,1100 volts, complete all as specified and directed.
S&F in replacement LED tube light fitting 1x20 watts, 220 volts AC, 1200 mm, with aluminium housing & integrated electronic driver complete with driver with polycarbonate diffuser & thd< 10% including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F in replacement of LED bulk head light fittings weather proof, anti corrosion wall/ceiling mounted opel colour decorative, round shape with PC cover suitable for & including 7 watts LED lamp, lamp holders complete all as specified and directed.
Supply,fixing and commissioning LED tube light fitting in replacement with new LED tube light fitting box type 230 volts AC suitable for & including 9/10 watts LED light fitting mirror type with high output diffuser 2 feet, 10 watt decorative type with driver holder and LED lamp including making of electrical connection with & including three core flexible copper conductor cable of suitable size, complete all as specified and directed.
S&F in replacement of recess mounting LED luminaire 2x2 36Watts (warm white/cool white 5700K/ 4000K), 220 volts AC recessed type with high efficiency PMMA diffuser, soft glare free light complete with suitable driver, holders & including suitable LED lamp suitable for POP/Gypsum/roof ceiling including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose including cutting of false ceiling in suitable size & making good the disturbed surfaces& matching with the existing surface including making of electrical connection with & including three core flexible copper conductor cable of suitable size complete with all accessories all as specified.
S&F in replacement of recess mounted compact vertical, round shaped energy saving LED downlighter luminaire 10 watts, 4000 K, 230 volts, 50 Hz complete with suitable LED driver lamp & all accessories internally prewired & including connecting up with three core twisted flexible copper conductor cable of suitable size including cutting of suitable hole in false ceiling complete all as specified.
S&F in replacement of LED wall light fittings 6/7 watt, 230 volts AC, indoor type made up of polycarbonate complete with lamp holder , LED lamp 6/7 watts, 4000 K, LED driver, connector block pre wired with all accessories all as specified.
S&F in replacement Inverter LED batten 20/22 Watt with Opal Diffuser, 6000 K IP 20, battery back up to 3 hrs & Functioning as per product TDS complete all including and connecting up including mounting with all accessories.
S&F in replacement Inverter LED bulk head 10 Watt, IP 65 with Opal Diffuser, IP 20, battery back up & Functioning as per product TDS complete all including and connecting up including mounting with all accessories.
S&F in replacement Inverter LED building security light 30 Watt, IP 66 with battery back up, Auto on/off/dimm Functioning as per product TDS complete all including and connecting up including mounting including GI pipe of suitable dia and clamps, nut, bolts, washers with all accessories.
S&F in replacement of recess mounting INVERTER LED 2x2 panel CRCA powder coated, IP-20 with battery back up & Functioning as per product TDS 36Watts (warm white/cool white 5700K/ 4000K), 220 volts AC recessed type with high efficiency PMMA diffuser, soft glare free light complete with suitable driver, holders & including suitable LED lamp suitable for POP/Gypsum/roof ceiling including connecting up with suitable size from ceiling rose including cutting of false ceiling in suitable size & making good the disturbed surfaces& matching with the existing surface including making of electrical connection with & including three core flexible copper conductor cable of suitable size complete with all accessories all as specified.
Replacement of 25 mm dia medium grade rigid non metallic PVC conduit alongwith its fixing accessories and making good to the disturbed surface to match the existing surface, complete all as specified and as directed.
S&F in replacement of 25x16 mm medium grade casing caping alongwith its fixing accessories & making good to the disturbed surface to match with the existing surface complete all as specified.
S&F in replacement inverter LED bulb 9W as per IS 16102 (Part-I &2) with emergency time 4 hours (battery back up with Li Ion battery ) base cap B22 D, with electronic driver, lumen maintenance for 50000 hours @ 70 insulated cu wire internal wiring and operating voltage from 140 v to 270 V, PF>0.9 system lumen efficacy ≥ 100 lumen/watt 6500 K, THD < 30% complete all as specified and directed.
Earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI wire 4mm dia bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20mm bore from bottom of earth pit to top of electrode and 20mm GI pipe light grade for earth wire protection complete with earth pit inplain cement concrete (1:2:4), type B0 using 12.5mm graded crushed stone aggregate with 40 mm thick cover of reinforced cement concrete (1:2:4) , type B-I , using 20 mm graded crushed stone aggregate, reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing including testing on completion, complete all as specified and and shown in electrical plate No 3 of MES Schedule 2009 Part-I, and as directed . Note:- Earthing to be done for replacement of existing earthing. The materials retrieved from earthing shall be credited to contractor. AFTER COMPLETION OF EARTHING, IF DESIRED RESISTANCE IS NOT OBTAINED, THE EARTHING WILL BE RE DONE BY CONTRACTOR AT HIS OWN RISK AND COST TO ENTIRE SATISFACTION OF ENGINEER-IN-CHARGE.
S&F in replacement electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60 Amp, accuracy class-I 50 Hz, conforming to IS 13779, IP-54 with parameters to show data, time, current reading, load, PF, voltage and KWH .
S&F in replacement post top lantern ENDURA SPRING 6 35 W energy saving, environment friendly, long life aesthetically designed with good indirect symmetrical light distribution, die cast aluminium landscape IP65 rating with high power COB LED as light source along with its mounting accessories.
Dismantling old unserviceable earth pit including electrode plate/ pipe and material and labour for modern maintenance free marconite conductive concrete based technology earthing system with same or different place as directed with copper bonded earth electrode (03 metres) inluding backfill compound and other accessories as required and connecting with copper strip 25x3 mm (upto 7.5 mtr max) in position with HDPE pit cover all as specified and as directed and having following specifications:- a) Fixed Carbon 98.5 % b) Ash, Volatile and Water 1.5 % c) Sulphur Content 1.5% Maximum d) Size Grading (Approx) - 10% below 0.10 mm,5% above 3.15 mm, 85% between 0.10 mm and 3.15 mm (e) Thermal Stability Between{-) 10% and (+) 60% ambient temperature (f) Ultra Low Resistivity (g) Versatile - shall be suitable for all type of soil and climate (h) Consistent Performance (i) Chemically Inert (i) Non-corrosive (k) Maintenance free and life span.
M&L for laying of XLPE PVC sheathed armored cable 10 sqmm 4 core complete all as specified and as directed .
M&L for laying of in replacement XLPE PVC sheathed armored cable 35 sqmm 4 core complete all as specified and as directed .
M&L for laying of in replacement XLPE PVC sheathed armored cable 50 sqmm 4 core complete all as specified and as directed .
Excavation in trenches in any type of soil not exceeding 1.5 m in depth and width and getting out complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removal of excess soil from site n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed.
Sand cushioning (dry sand) to underground cable for cable protection laid in trenches / in existing cable ducts complete all as specified and as directed. Note: For payment point of view, punned thickness of sand shall be measured.
Brick laying with subclass 'B' bricks well burnt, laid dry flat in trenches for protection of cable over LT cable, complete all as specified and as directed.
Note :- An amount of Rs. 21,122.50 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
FG CONSTRUCTION
M/s Gh Qadir and Sons
M/S BASHIR AHMAD AND SONS
M/S GEE EMM MIR
MS Ghulam Hassan and Sons
ORISON ENTERPRISES
M/S BALI AGENCIES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .