Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.1 LAccepted-AOC NEAR AVON PUBLIC SCHOOL DABHANW POST DANDI NAINI PRAYAGRAJ 211008 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | 1 | Accepted-AOC L-1 | |
| 2 | 2₹31.9 L+₹53,557 (1.71%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹32.5 L+₹1.2 L (3.72%)Rejected-Finance | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹33.0 L+₹1.6 L (5.06%)Rejected-Finance MD 1 236 SECTOR D1 LDA COLONY KANPUR ROAD LUCKNOW U P PIN 226012 | LUCKNOW | UTTAR PRADESH | 226012 | 4 | Rejected-Finance Being other than L-1 | |
| 5 | 5₹36.5 L+₹5.2 L (16.5%)Rejected-Finance GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | 5 | Rejected-Finance Being other than L-1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
5 Oct 2021, 6:00 pmClosed
GE EAST LUCKNOW
GE EAST LUCKNOW
REPAIR REPLACEMENT OF INTERNAL WIRING FITTING IN CERTAIN OTM AND MD ACCN IN AGE EM YARD-I UNDER GE (EAST) LUCKNOW
2021_MES_473380_1
GE/E/LKO/T-30 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Lucknow Cantt
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
GE EAST LUCKNOW
₹80,000
Yes
27 Oct 2021
7 Sept 2021
6 Oct 2021
7 Sept 2021
5 Oct 2021
21 Sept 2021
Amount
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete all as specified and directed.
M&L for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick with 3 mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed.
All as per serial item No 02 here-in-before but one bell point controlled by one bell push, 06 Amp.
All as per serial item No 02 here-in-before but one, two way light point controlled by two, two way switches, 06 Amp.
All as per serial item No 02 here-in-before but one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp.
All as per serial item No 02 here-in-before but one 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch 06 Amp.
All as per Serial Item No 02 here-in-before but point wiring with 2.5 Sq mm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 16 Amp socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F switch piano 06 Amp, single pole, one way, 230 Volt complete all as specified & directed.
S&F switch06 Amp, s two way, 230 volt complete all as specified & directed.
S&F bell push, 06 Amp, 230 volt complete all as specified & directed.
S&F socket outlet 06 Amp, 230 volt complete all as specified & directed.
S&F switch socket combination outlet 06 Amp and 16 Amp , 230 volt, four hole complete all as specified & directed.
M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor ( FRLS) of size 1.5 Sqmm( for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor ( FRLS)(as earth wire colour code green)and connected to common earth dolly all as specified Make: ISI reputed, drawn through in including concealed PVC Conduit medium grade ISI marked not less than 19.5 mm / 20 mm dia , Make: Cap/Seiko along with conduit fixing accessories and with Modular metal flush box including modular white cover with frame as per specified SSR complete all as specified & directed.
All as per Item No.13 above but for 5 Amp socket outlet independent.
All as per Item No.13 above but on the same board.
All as per item No 13 above but for one bell/Buzzer point controlled by one push button on the same board with other switches or independent with 1,50 sqmm size cable.
All as per Item No. 13 above but with 2.5 Sqmm copper wire for 15 Amp socket outlet independent with 1.5 sq mm copper green colour wire as earthing.
S&F modular switch10 Amp 1 way 230 V complete all as specified & directed..
S&F modular switch 16 Amp 1 way 230 V complete all as specified & directed.
S&F modular socket outlet 6 Amp 240 volt complete all as specified & directed.
S&F modular socket16 Amp 2 module complete all as specified & directed.
S&F ding dong bell, AC, 230 volt, single pole complete all as specified & directed.
S&F electronic ceiling fan regulator with rotary step, two module, AC, 240 volt, 100 Watt complete all as specified & directed.
S&F lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting complete all as specified & directed.
S&F in replacement of decorative wall mounting type LED light fitting, 1 x 15 Watt, 230 Volt made up of Polycarbonate including shade, lamp holder, 10 Watts LED lamp B22 CDL etc and all accessories pre-wired including connecting up complete all as specified and directed.Make :Philips, Cat No : 30575 (Comet) or Havells, Cat No : LHDL06160099 (CITY 3).
S&F in replacement of integrated LED bulk head fitting 10 Watt, 6500K with IP 65 protection comprises of high pressure die cast aluminium housing, polycarbonate cover, etc complete all as specified and directed. Make : Crompton, Cat No : LBHE-10-CDL or equivalent in Havells, Cat No : RUGBYNEONFT10WLED760SSYMBOPC, PHILIPS Cat no WT202WLED6SCWPSUS2PC
S&F decorative wall mounting chrome finish 3W LED Bed Light fixture with all accessories all as specified and directed. Make: Havells or equivalent as approved by GE.
S&F indicating light ( RED& GREEN ) of zero watt with suitable pvc poly carbonared fixture including necessary connection with 1.5 sqmm wire as required site complete all as specified & directed.
S&F in replacement of single side connection LED T8 tube light rod 20 Watt, 6500K of four feet long into and including LED tube light fixture of four feet long with T8 push fit type holders, connector block, end caps, etc including connecting up complete all as specified and directed. Make : Crompton, Cat No : IGP131LT8-16& LT8-20-865-2 or equivalent in Havells, Cat No : REGALBATTENT8UPT01X22WSSBS & PHOTONULTRA1213T8SSTL20WLED865SPC,philips cat no TMC 100 1xT LED /MAS LED tube 1200 mm 18 w 865 T8 I - 2100 Lumen
S&F in replacement of recessed mounted 2'x2' LED ceiling light fitting 36 watt, 6500K, with IP 20 protection comprises of CRCA housing, high efficiency diffuser cover, electronic driver, etc and all accessories pre-wired including connecting up complete all as specified and directed. Make : Crompton, Cat No : LCPL-36-CDL(2X2)or equivalent in Havells, Cat No : VENUSNEOHE2X2PLR36WLED8XXS philips cat no RC380BLED36-6500G4L60W60 PSU OD OC.
S&F in replacement of LED security light fitting 45 watt, 5700K with IP 66 protection comprises of a pressure die cast aluminium housing, heat resistance toughened glass, LED lenses, surge protector, electronic driver, etc and all accessories pre-wired including connecting up with PVC insulated copper conductor cable 1.5 Sq mm, 3 core as required for connections and 32 mm bore light grade G. I. tube mounting bracket of 1.5 metre in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete all as specified and directed. Make : Crompton, Cat No : LSTP-45-CDL or equivalent in Havells/ philips
Supply and fix ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified & directed.
Taking down carefully ceiling fan of any sweep complete with all accessories, dismantling blades and kept in safe custody including painting complete with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and hanging and connecting up with provn of 3 core copper flexible cable of size 1.5 Sq mm from ceiling rose to fan complete all as specified & directed.
M&L for sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
M&L for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
S&F in replacement of industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 240 volt of 20 Amp, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed. Make: - Legrand, Cat No. 5078 11 & 4085 93 or equivalent in Hager, Cat No : VYA120C & NCN120N or Schneider, Cat No : A9HMS220 & A9N1P20C
S&F in replacement of sheet metal enclosure distribution board, single pole and neutral, AC, 240 volt, 08 way, with 200 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed. Make :-Legrand, Cat No. 5076 11 & 5079 13 or equivalent in Hager, Cat No : VYS08D & VYS08E or Schneider, Cat No : A9HSND08 & A9HSND08WB
Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed Make :-Legrand, Cat No. 5077 50 & 5079 38 or equivalent in Hager, Cat No : VYV04PM & VYV00E or Schneider, Cat No : A9HVD04M & A9HVDXXWB and comprising of the following:- (a) MCCB, 125 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. Make :-Legrand, Model : DPX 160, Cat No. 4200 16 or equivalent in Hager, Cat No : HDA126Z or Schneider, Cat No : LV516312 (b) MCB, SP, AC, 240 volt of 06 to 32 Amp, "C" curve, 10 KA breaking capacity - 12 Nos. Make :-Legrand, Cat No. 4085 87 to 4085 95 or equivalent in Hager, Cat No. NCN106N to NCN132N or Schneider, Cat No. A9N1P06C to A9N1P32C
S&F in replacement of MCB, SP, AC, 240 volt of 06 to 32 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. Make :-Legrand, Cat No. 4085 87 to 4085 95 or equivalent in Hager, Cat No : NCN106N to NCN132N or Schneider, Cat No : A9N1P06C to A9N1P32C.
S&F in replacement of MCB, DP, AC, 240 volt of 32 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. Make :-Legrand, Cat No. 4086 36 or equivalent in Hager, Cat No : NCN232N or Schneider, Cat No : A9N2P32C
M&L for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed.
S&F in replacement of MCB, SP, AC, 240 volt of 32 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. Make :-Legrand, Cat No. 4085 87 to 4085 95 or equivalent in Hager, Cat No : NCN106N to NCN132N or Schneider, Cat No : A9N1P06C to A9N1P32C.
S&F MCB, SP, AC, 240 volt of 25 Amp capacity "C" curve, 10 KA breaking capacity complete all as specified & directed. Make :-Legrand, Hager, Schneider or equivalent.
S&F MCB, SP, AC, 240 volt of 16 Amp capacity "C" curve, 10 KA breaking capacity complete all as specified & directed.Make :-Legrand, Hager, Schneider or equivalent.
S&F switch piano flush type, 06 Amp, single pole, one way, 230 Volt complete all as specified & directed.
S&F switch piano flush type, 06 Amp, single pole, two way, 230 volt complete all as specified & directed.
S&F bell push, flush type, 06 Amp, 230 volt complete all as specified & directed.
S&F socket outlet 2 in 1, 5 pin, 06 Amp, flush type, 230 volt complete all as specified & directed.
S&F switch socket combination outlet 2 in 1, 3 pin, 06 Amp and 16 Amp flush type, universal, 230 volt, four hole complete all as specified & directed.
S&F lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting complete all as specified & directed.
S&F Modular switch piano type 10 Amp 1 way single pole 230 V all as specified.
S&F modular switch piano type 16 Amp 1 way single pole 230 V all as specified.
S&F modular socket outlet 6 Amp 2/3 Pin 240 volt flush type all as specified.
S&F modular socket 2/3Pin ,6 & 16 Amp 2 module multipurpose all as specified.
S&F ding dong bell, AC, 230 volt, single pole complete all as specified & directed.
S&F in replacement of double side connection LED T8 tube light rod 20 Watt, 6500K of four feet long into existing T8 conventional fluorescent tube light fitting after changing the necessary electric connections as required at site complete all as specified and directed. Make : Crompton, Havells,PHILIPS or equivalent.
S&F in replacement of single side connection LED T8 tube light rod 10 Watt, 6500K of two feet long into and including LED tube light fixture of two feet long with T8 push fit type holders, connector block, end caps, etc including connecting up complete all as specified and directed.Make : Crompton/ havells / philips
S&F laminated sheet cover of size 8" x 5" hylam ISI marked 3mm thick including cutting of sheet for fixing switches/sockets as required at site incl suitable size screws - 04 Nos for fixing on existing MS sunken boxes complete all as specified and directed.
S&F laminated sheet cover of size 7" x 4" hylam ISI marked 3mm thick including cutting of sheet for fixing switches/sockets as required at site incl suitable size screws - 04 Nos for fixing on existing MS sunken boxes complete all as specified and directed.
S&F laminated sheet cover of size 5" x 5" hylam ISI marked 3mm thick including cutting of sheet for fixing switches/sockets as required at site incl suitable size screws - 04 Nos for fixing on existing MS sunken boxes complete all as specified and directed.
S&F laminated sheet cover of size 8" x 10" hylam ISI marked 3mm thick including cutting of sheet for fixing switches/sockets as required at site incl suitable size screws - 04 Nos for fixing on existing MS sunken boxes complete all as specified and directed.
S&F laminated sheet cover of size 12" x 10" hylam ISI marked 3mm thick including cutting of sheet for fixing switches/sockets as required at site incl suitable size screws - 04 Nos for fixing on existing MS sunken boxes complete all as specified and directed.
S&F laminated sheet cover hylam brand ISI marked 3mm thick round sheet for fixing on junction boxes as required at site incl suitable size screws - 01 Nos complete all as specified and directed.
S&F in replacement of unserviceable wire of size 1.5 Sqmm with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts single core of 1.5 Sqmm complete all as specified & directed.
S&F in replacement of unserviceable wire of size 2.5 Sqmm with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts single core of 2.5 Sqmm complete all as specified & directed.
S&F in replacement of unserviceable wire of size 4.0 Sqmm with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts single core of 4.0 Sqmm complete all as specified & directed.
S&F in replacement of unserviceable wire of size 6.0 Sqmm with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts single core of 6.0 Sqmm complete all as specified & directed.
S&F PVC gang box suitable for 6 Amp Socket and 6 amp switch complete all as specified & directed.
S&F the insulation tape 10 Mtr complete all as specified & directed.
S&F the 10 watt LED Mirror light fitting complete all as specified & directed. Make CG cat pat No-LDL-10-WW or equivalent of Bajaj/philips.
S&F PVC gang box suitable for 16 Amp Socket and 16 amp switch complete all as specified & directed.
S&F in replacement PVC enclosure suitable for MCB complete all as specified & directed. Make: Anchor/Indoasian/HPL or equivalent.
S&F in replacement PVC casing and caping ISI marked of size 20mm complete all as specified & directed.
S&F in replacement PVC casing and caping ISI marked of size 25mm complete all as specified & directed.
S&F in replacement flexible conduit of size 20mm ISI marked complete all as specified & directed.
S&F in replacement flexible conduit of size 25 mm ISI marked complete all as specified & directed.
Unnati Engineers
SAKSHAM SUPPLIERS BUILDERS
R K CONTRACTOR AND SUPPLIERS
QUALITY CONSTRUCTIONS CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .