Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.9 LAccepted-AOC H NO 19 6 243 1 NGO S COLONY SHIV NAGAR NORTH BIDAR 585401 | BIDAR | KARNATAKA | 585401 | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹62.5 L+₹2.7 L (4.57%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 3 | L3₹67.2 L+₹7.4 L (12.4%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
₹71.9 L
EMD Value
₹1.3 L
Closing Date
7 Apr 2021, 6:00 pmClosed
CWE AF Secunderabad
CWE AF Secunderabad Bowenpally Post Secunderabad 500011
SPECIAL REPAIRS TO CERTAIN TYPE1 QTRS PHASE I AT AFA HYDERABAD
2021_MES_430121_1
86626/E8
Open Tender
Civil Works
Item Rate
270 days
GE AFA Hyderabad
As Per NIT
9 documents required · 9 mandatory
₹1,000
GE AFA Hyderabad
₹1.3 L
19 Apr 2021
12 Mar 2021
9 Apr 2021
12 Mar 2021
7 Apr 2021
26 Mar 2021
12 Mar 2021 - 22 Mar 2021
Amount
Demolition of stone slabs and tiles of any description or thickness in floors, aprons, roof etc laid, bedded and jointed in cement morter complete all as specified and as directed.
Demolition of Surkhi, in roof slabs any thickness including plasterining and leeping (weather full thickness removed or only part there of )
Roughening of old existing top concrete surfaces in roof by picking, sweeping clean and washing down with water to remove dust, etc.
Brushing neat cement slurry with 3.0kg of cement per sq. metre with water proofing compound. Note: Water proofing compound shall be measured & Paid seperately at supply only rates
M&L for PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) average 50 mm thick with laid on RCC slab maintaining proper slope complete all as specified and as directed.
M&L 10mm thick screed in CM (1:4) mixed with water proofing compound @ 3% by weight of cement over while the padding concrete is still green complete all as specified and as directed. Note: Water proofing compound shall be measured & Paid seperately at supply only rates
M&L for Cleaning the roof surfaces and applying oil bound bitumen primer @ 0.20 Kg per Sqm, supply and laying 4mm thick APP modified water proofing membrane weight not less than 4 Kg per Sqm reinforced with non woven polyster mat weight not less than 160 gm per Sqm having softening point not less than 140 degree centigrade, longitudinal tensile strength not less than 800 N per 5 cm end laps by application of torch over and including applying a coat of blown grade hot bitumen @ 1.20 Kg/Sqm complete all as specified and as directed.
M & L 15 mm thick screed bed or bedding layer in CM (1:6) for laying of floor finishes complete all as specified and as directed.
S & F cement concerete tiles 20-25cm x 20-25 cm x 20mm thick machine pressed set jointed and pointed in neat cement slurry cut and polished with grey cement and no pigments floors complete all as specified and as directed.
M&L PCC 1:2:4 type B0 by using (12.5 mm graded stone aggregate) as in copings /benching and padding and chajjas for maintaining slopes where required over slabs not exceeding 15cm thick including necessary form work and finishing the exposed surfaces even without using extra cement complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position, pre-cast slabs, coving and concrete padding over roof slab including for sunken floor and cleaning/washing the area complete all as specified and as directed.
M&L for PCC (1:2:4) type B0 (using 12.5mm graded stone aggregate) average 25mm thick with water proofing compond finished even and smooth in sunken floor portion etc. complete all as specified and as directed. Note: Water proofing compound shall be measured & Paid seperately at supply only rates
Rendering 10mm thick in cm 1 : 4 mixed with water proofing compound as per manufacturers instructions on concrete/brick surfaces finished even and smooth without using extra cement complete all as directed Note: Water proofing compound shall be measured & Paid seperately at supply only rates
M&L for cleaning of surfaces thoroughly from dust projection and dirt by wire brushing and applying a coat of blown grade bitumen 85/25 @ 1.2 Kg/ sqm over that laying waterproofing treatment of AP based polyimetric membraine with minimum 3 mm thick and 3 kg/Sqm reinforced with polyster non wooven fabric weight not less than 150 gms/Sqm laid by forced applications in sunken portion all as specified and as directed.
S & F 25 mm bore dia GI pipe medium grade for spout as in sunken floor all as directed.
S&F in repairs Vitreous China, semi-pedestal pattern (Anglo-Indian Type) with trap, white including connections to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe, etc. with insertion of PVC (SWR) pipes of required length, along with P-trap or S-trap as per site requirements and including flush tank, flush pipe, toilet seat, seat cover,etc, including making good to floor finish, complete all as specified and directed
M&L for PCC (1:5:10) type E2 (using 40mm graded stone aggregate) filling and mass concrete complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as directed.
M&L for Non-skid coloured ceramic tiles 7 to 8 mm thick (square)/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles complete all as specified and as directed.
M&L for rendering 10mm thick in CM 1:4 on fair faces of brick/concrete surfaces rough finished surface as backing coat to receive wall tiles complete all as specified and as directed.
M&L Glazed ceramic coloured tiles in vertical surfaces of size 450mm x 350mm x 7 mm thick superior finish, B-III Gde as in dado/skirting , set and jointed in neat cement slurry and pointed in white or colour cement to match with the colour of the tiles complete all as specified and as directed.
S&F of CP Bib taps two way 15 mm fancy type with capstan head handle screwed down screwed for iron pipe or for brass ferrule etc complete all as specified.(Make : Jaguar or equivalent)
S&F CP health faucet with 1.2m long flexible tube & wall hook complete set complete all as specified.
Supply and fix PVC connection 15 mm bore with brass cp nuts, of length 450 mm complete all as specified and as directed.
Supply only integral water proofing compound
Taking down chowkats or frames with shutters (without taking off shutters from frames) not exc 1.5 Sqm each complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) exc 1.5 Sqm but not exc 4 Sqm each complete all as specified and as directed.
Taking down of shutters exc 1 Sqm and n exc 2 Sqm each and deposited to MES store yard complete all as directed.
S&F second class hard wood in scantlings timber framed and clean sawn for chowkats complete all as specified and directed.
Supply and fix MS work as in hold fasts, bands, straps and like conforming to Fe-290, Gde E-165 complete all as specified and as directed.
S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail ; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawings given in Section 8 of MES Schedule Part-II 2010 as applicable.
S&F 35 mm thick, factory made flush shutters ,solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 100 mm long butt hinges of extruded aluminium anodised complete all as specified and as directed.
S&F 300 mm long aluminium alloy, anodised sliding door bolts, with hasp,staple (bolt type) and fixing clips of sheet, cast or extruted sections and fixing bolts and sliding bolts of extruded sections complete all as directed.
S&F 150mm long aluminium anodised, extruded handles, fabricated type complete all as directed.
S&F 200 mm long aluminium anodised barrel tower bolt of extruded section complete all as directed.
S&F 100 mm long aluminium anodised handles cast type complete all as specified and as directed.
S&F 100 mm long aluminium anodised barrel tower bolt of extruded section complete all as directed.
Taking down steel windows, gates but excluding framed truss etc
S&F steel windows with side hung shutter (glazing or gauzed shutters) including box type hinges with steel handle and steel peg stay complete with glazing bars, dovetailed or welded conforming to IS including one shop coat of red oxide primer and fixing of 25x5mm size flat iron hold fasts complete all as specified and as directed.
S&F for MS guard bars for windows/ventilators complete all as specified and as directed
Hacking out old unserviceable glass/broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins / spring clips and providing and fixing new ones complete all as specified and as directed.
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty in metal frame in squares not exc 0.50 Sqm each pane and second class hard wood beading in wooden frame complete all as specified and directed.
S&F 4mm thick figured glass, pin headed type and glazing with oil putty in metal frame in squares not exc 0.50 Sqm each pane complete all as specified and directed.
S&F in Repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
S&F of plain, Aluminium sheeting 0.56mm thickness, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) and fixing with door shutter bottoms etc. complete all as specified and as directed.
Repair of shutters of any description of area exc. 1 sqm but n.exe 2 sqm and refixig in same opening complete all as specified.
Taking up or down PVC/steel tubing 15mm dia bore and connections, including cleaning for refixing or removal to store complete all as directed.
Taking up or down PVC/steel tubing 20mm dia bore and connections, including cleaning for refixing or removal to store complete all as directed.
Taking up or down PVC/steel tubing 25mm dia bore and connections, including cleaning for refixing or removal to store complete all as directed.
S&F 15mm bore steel water tubing, medium grade, galvanised with all fittings fixed to wall and ceiling or laid in floors complete all as specified and as directed.
S&F 20mm bore steel water tubing ,medium grade, galvanised with all fittings fixed to wall and ceiling or laid in floors complete all as specified and as directed.
S&F 25mm bore steel water tubing, medium grade, galvanised with all fittings fixed to wall and ceiling or laid in floors complete all as specified and as directed.
Dismantling of 100mm dia cast iron drain pipes, jointed in cement mortar and taking out complete all as directed.
Dismantling of 75 mm dia cast iron drain pipes, jointed in cement mortar and taking out complete all as directed.
S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors or on walls as rain water pipe etc complete all as specified and as directed.
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F PVC (SWR) bends suitable for 110 mm dia PVC (SWR) pipes provide with access door complete all as specified and as directed.
S&F PVC (SWR) branch piece double (double Y) equal or unequal suitable for 110mm dia PVC (SWR) pipe complete all as specified and as directed.
S&F PVC (SWR) vent cowl of 110mm dia complete all as specified and as directed.
S&F PVC (SWR) bends suitable for 75mm dia PVC (SWR) pipes provide with access door complete all as specified and as directed.
S&F PVC (SWR) branch piece single (single Y) equal or unequal suitable for 75mm dia PVC (SWR) pipe complete all as specified and as directed.
S&F PVC (SWR) vent cowl of 75 mm dia complete all as specified and as directed.
S&F Cast iron nahani trap of 75mm size with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as directed.
S&F PVC (SWR) work for clamps, supports or stays for rainwater pipes, ventilating pipes, including bolts, if required and pintle hinges hand made sliding bolts, clamps, hold fasts, wall ties, plain angle cleats for securing similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
Disconnection existing tanks setting aside and hoisting of PVC water tank of capacity exc 250 & n exc 500 ltrs including cleaning and removing all scale & dirt, etc from tanks , required reconnecting and re- fixing in position all scale and dirt etc from tanks
S&F in repairs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 ltr capacity, 2 layered hoisted and fixed in position including out let and inlet connections,all as specified in SSR part – I.
S&F in repairs ball valve 25 mm dia, high pressure of PTMT, with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimium wt.25-455gms complete all as specified and as directed.
S & F in repairs gun metal, globe or gate valve of 25 mm bore dia with iron wheel head, screwed both ends for iron pipe of 25 mm bore pipe complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as directed.
M&L for brick work with sub class ‘B’ bricks, straight or curved on plan exc 6 M means radius built in CM (1;6) using old size bricks complete all as specified and as directed.
M&L for brick work with sub class ‘B’ brick straight or curved on plan to any radius built in half brick thick wall built in CM (1:4) using old size bricks complete all as specified and as directed.
Taking down cement plaster of any description on brick or stonewalls, including raking out joints, hacking for key, scrubbing down with water etc complete all as directed.
M&L for rendering internal wall surfaces of 10 mm thick in CM 1:6 on fair faces of brickwork or concrete surfaces and finishing surfaces for even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 5mm thick in CM 1:3 on concrete surfaces in ceiling, chajjas finished even and smooth (without using extra cement) complete all as specified and as directed.
M&L for plastering in external wall surfaces of 15mm thick in two layers i.e setting coat 5mm thick in CM 1:4 with WPC over 10mm thick cement plaster in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and as directed. Note:- Water proofing compound shall be measured and paid separately.
M&L for preparation of newly plastered surfaces of ceiling and applying two coats white wash etc. complete all as specified and as directed.
M&L for preparation of the existing treatment on ceilings and applying two coats of white wash including washing, rubbing down with wire brushes of surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces of internal walls and applying two coats of white wash etc. complete all as specified and as directed.
Complete removal of the existing treatment on walls and applying two coats of white wash including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered internal wall surfaces by complete removal of existing treatment by washing, rubbing down with wire brushes and stopping of distempered surfaces and applying two coats of distemper oil emulsion over a coat of chalk whiting putti for smooting and one coat of primer paint complete all as specified and as directed.
M&L for preparation of old plastered internal wall surfaces by washing, rubbing down with wire brushes and stopping of distempered surfaces and applying two coats of distemper oil emulsion over a coat of chalk whiting putti for smooting and one coat of primer paint complete all as specified and as directed.
M&L for preparation of newly plastered surfaces on external walls including cornices by applying two coats of cement based paint over a coat of alkali resistant primer and all as specified and directed by the Engineer-in-Charge.
M&L for for preparation of old plastered external wall surfaces by washing, rubbing down with wirebrushes and stopping of distempered surfaces including cornices by applying two coats of cement based paint over a coat of alkali resistant primer, colour and all as specified and directed by the Engineer-in-Charge.
M & L for preparing newly painted wood and wood based surfaces of any description, not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer all as specified and directed.
M & L for preparing old painted wood and wood based surfaces of any description, not otherwise described and applying one coat of synthetic enamel paint all as specified and directed by Engineer-in-Charge.
M & L for preparing steel and iron newly surfaces of any description, over 10 cm in width or girth not otherwise described applying two coat of synthetic enamel paint over a coat of Red oxide zinc chrome all as specified and directed.
Demolition of cement Concrete in ground floors and paving n exc., 15 cm thickness (below or above ground level).
M&L for 75 mm thick Cement concrete type D -2, 1:4:8 (40 mm graded aggregate) in subbase of floors
M&L for 40 mm thick Cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) in floors
S&F Glass dividing strips, 3mm thick 22 mm width of strip, as specified and as directed
M&L for screed bed or bedding layer of mortar 20mm thick for laying floor finishes in CM (1:6) etc complete all as specified.
M&L for Machine cut cuddappa stone slab flooring over cooking platform of 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as spefied and as directed.
M&L rounding to edges of stone slabs one edge, in cooking plotforms complete all as specified
Demolition of reinforced concrete of any description not other wise specically provied for chimnies etc complete all as specified and as directed
S&F in repairs of Vitreous china wash basin, white flat back, size 550 x 400 mm etc complete all as specified.
S&F in repairs of Waste coupling of 32 mm chromium plated for glazed ware basins with long screwed shanks and fly-nuts etc complete..
S&F in repairs of Pillar taps 15 mm dia, cast copper alloy, with capstan heads, Long nose , chromium plated fancy type screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe of 15 mm bore etc complete.
Supply and fix in repairs stainless steel sink overall size 915mmx460mm bowl size 410mmx330mmx160 mm with draining board made out of stainless steel 1 mm thick for kitchen with plugs, washers and waste pipe including cast iron cantilever brackets and connecting to union / pipe complete all as specified and as directed.
Removing and refixing of existing stainless steel sink of any size, with plugs, washers, waste coupling and waste pipe including cast iron cantilever brackets and connecting to union / pipe complete all as specified and as directed.
S&F in repairs 15 mm bore dia Bib taps cast copper alloy with crutch or butterfly handle screwed down for iron pipe or brass ferrule complete all as specified and as directed.
S&F in repairs 15 mm bore stop valve, cast copper alloy, fancy type chromium plated with long shank and cup (concealed/angular type) screwed down high pressure with crutch or butterfly handle screwed both ends for Iron pipe or for unions complete all as specified and as directed.
S&F in repairs stainless steel hinged gratings 100mm dia fixed with suitable solvent cement etc complete all as directed.
Running wleding in repair of thickness of metal n.exe 6mm complete all as directed.
Welding in repairs of thickness exc 6mm but not exe 9mm and length exc 2.5 cm but not exe 5 cm complete all as directed.
Supply and fix tubular towel rail of 20 mm dia, D type ofAlumimium anoidised 600 mm long between flanges, including brackets complete all as specified and as directed.
S&F in repairs Soap dish, vitreous China white, approximate size 160x160x90mm including fixing complete all as specified and as directed
M&L for post construction anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion (in oil or kerosene based solution of chlorpyrifos 20 EC or Lindane 20 EC) @ 2.25 litres per linear metre including drilling and plugging holes etc., in apron etc all as directed by Enginee-in-Charge.
M&L Anti termite treatment for wooden frames of doors/Windows at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ .5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as specified and as directed
Removing of plants including roots by dismantling of brick work / PCC / RCC including necessary scaffolding,any type,any location /height ( i.e roof, parapet walls near pipes etc.) and applying Acid after removing roots for preventing the regrowth and making good the disturbed portion using PCC 1:2:4 Type B-O and plaster in CM 1:3 (size of disturbed portion 150 x 150 x 150mm) complete all as specified & directed by Engr- in -Charge.
S&F in repair of Bib taps, cast copper alloy , screwed for iron pipe or for brass ferrule and fixed to 15mm bore pipe.
Taking down the unserviceable point wiring (light, fan,socket or power) complete with fittings such as switches, sockets ceiling roses pendent regulators, sockets etc any light points and making good distrubed surfaces of walls and floors etc complete all as specified and directed.
Taking down unserviceble MCBs, DBs, Main switches complete all as specified and directed.
Removing the existing metering sheet box from the existing wall after removing the unserviceable DBs and meters and making good distrubed surfaces of walls all as specified and directed.
Point wiring with 1.5 Sqmm copper conductor unsheathed, multistranded, PVC insulated, single core cable with earth continuty conductor of 1.5 sqmm PVC insulated copper conductor in and including rigid PVC conduit/Casing caping of suitable size with accessories fixed to the surface of the roof/ walls etc., Including terminal boxes made out of 1.6mm thick MS sheet for switches, fan regulators socket outlet etc along-with 3mm thick top laminated bakelite sheet for housing switches, sockets, regulators etc for the for One light point controlled by one one way 5 Amps switch
All as per item No 116 above but one light point controlled by two, two way 5 Amps switch
All as per item No 116 above but one ceiling fan /Exhasut fan point controlled by one 5 Amps switch
All as per item No 116 above but socket 5 amp on independent board.
All as per item No 116 above but one 3/5 pin socket out let 5 amp on same board with other switches.
All as per item No 116 above but one bell/buzzer controlled by one 5 Amps push button switch.
All as per item No 116 above but wiring with 2.5 sq mm copper cable with 1.5 sq mm for one earth continuty cable for 6 pin 15 Amps socket out controlled by 15 Amps switch.
Supply and fix switch socket combination 5 A/ 15 Amps 5 in 1, multipurpose flush type, ISI marked complete all as specified and as directed.
Supply and fix switch socket combination 2 in 1, 5 Pin 5 Amps, multipurpose flush type, ISI marked complete all as specified and as directed.
Supply & Fixing socket 3/5 pin 5 Amp flush type.
Supply and fix switch piano flush type, single pole, one way, 5 Amps, 230 volts, ISI marked complete.
Supply and fix switch piano flush type, single pole, two way, 5 Amps, 230 volts, ISI marked complete.
Supply and fix bell push , 5 Amps, 230 volts, ISI marked complete.
S&F ceiling rose, three terminal, PVC/polycarbonate, isolated body, ISI marked complete.
Supply and fix Bell Multi Music type AC 230 V complete all as specified and as directed.
S & F stepped type electronic fan regulator flush type all as specified and as directed.
Supply & Fixing angle holder/batten holder insulated
S&F surface and wall mounted LED tube light fitting 20 watts including LED tubes 4 ft complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable white colour with suitable size all as specified CG Cat No. LCTLN-20 -CDL
Supply and fixing security light fittings with high power LED type comprises a single piece deep drawn aluminium housing in sand blasted & anodized finish from out side, aluminium gear tray wired with LED,s and driver with heat resistent glass and synthetic gasket to ensure IP 66 ingress protection of capacity 25 watt including GI Pipe light grade 40 mm for brackets not more than 1.5 Mtr length with necessary clamps, nut bolts etc complete all as specified. necessary connection complete all as specified and as directed by Engineer- in - Charge MAKE: CG Cat noLSTS-25-CDL
M/L sub-main wiring with two runs of 6 sqmm unsheathed PVC insulated, single core cable with copper stranded conductor in and including suitable PVC Conduit with 6 sqmm copper earth wire after taking out the existing sub-main wiring , etc. Note: 2 runs of cable and one run earth wire and conduit will be measured as one length.
M/L sub-main wiring with four runs of 16 sqmm unsheathed PVC insulated, single core cable with copper stranded conductor in and including suitable PVC Conduit with two runs of 16 sqmm copper earth wire after taking out the existing sub-main wiring , etc. Note: 4 runs of cable and One run earth wire and conduit will be measured as one length.
Supply, Installation, testing and commisioning of indoor type wall mounted (with bolts and nuts) meter cabinat of overall diamentioin 1200mm (W) x 750mm (H) x 200mm (D), made out of 2mm thick CRCA MS sheet with front door having glass window for viewing KWH meter and other door shall be opeque. All doors should have gasket and locking arrangement. The cabinet shall be painted both internally and externally with two coats of synthetic enamel paint (Shade- nickel Grey) over acoat of red oxide metal primer duly sprayed with the compressor. The cabinet shall be dust and vermin proof with degree of protection of IP 43. The cabinet shall be comprising with the following accessories:- (a) Four pole MCCB, 63 Amps, with breaking capacity 16 KA having adjustable thermal and fixe magnetic release. Make :- Legrand /L&T/Schneider/Havells
(b) Aluminium bus bar of cross section 25 x 3mm duly mounted n FRP/DMC insulators and necessory drilling ( one Incomming & minimum 6 out going) for connections and duly covered with heat shrinkable PVC sleves of standed colour code- 4 Nos.
(c) Single phase KWH meter of rating 5- 30 Amps, base mounting electronic tampper proof type with optical port suitable for AC 230 V, 50 Hz - 4 Nos. Make :- L&T/ HPL/ SECURE.
(d) MCB SPN 6- 32 Amps, 10 KA - 5 Nos (4 with meter+ 1 for common lighting ) Make :- Legrand /L&T/Schneider/Havells
(e) Internal wiring of meterr/ MCB/ Cable connector, shall be crrie out with 10 Sqmm and from MCCB to bus bar to be 25 sqmm.multiflexible copper wire with FR grade PVC insulation of 1100 volts rating including necessary lugs/nuts/bolts/washers etc,
(f) LED Indicating lamp (R,Y,B) suitable for AC 230 V single phase supply with bakelite slide locking type fuse holder 6 Ammps rating. - 3 Nos.
(g) Time switch analog type with battery backup front moumting 24 Hrs programable every 20 min, backup of 100 Hrs with change over of capacity 16 Ams. Make :- L&T/ Indo Asian/ Legrand. Note :- (i) Old unserviceable KWH meters shall have to be deposited to MES store (ii) Rate deemed to be inclusive of disconnection/ reconnection of existing incoming/ outgoing cables/ wires complete.
Supply and fix Sheet metal enclosure double door MCB DB SPN 8 way with 200 A rated bus bar & neutral link.
MCB SPN 6 to 32A, 10 KA rupturing capacity.
MCB SP 6 to 32A 10 KA rupturing capacity.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core including cable connecting lugs, glands, jointing materials etc, laid in trenches, floors, roof ducts and fixing using clamps, saddle for pole wall , complete all as specified and as directed by Engineer-in-Charge.
M&L for earthing complete with Galvanised steel earth plate eletrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filled in alternate layers and electrode connections by using Galvanised earth strip 32x6mm connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) type C1 chamber of size 45cm X 45cm X 45cm including, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I
Excavation in trenches n.exc 1.50 m wide and not exc 1.5 m depth and getting out in soft / loose soil complete all as specified and directed by engineer-in-Charge.
Material & Labour for road cutting to lay LT UG cable including making good the disturbed surfaces as per existing complete all as specified and directed by engineer-in-Charge.
Returing, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in soil all as specified and directed.
Removing excavated materials not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point.
Supply and filling river sand to the full width of trenches for protection of cables including spreading and punning down complete all as specified. Note : Punned thickness of sand will be considered for payment purpose.
Supplying and laying bricks common burnt clay building bricks, sub-class ‘B’ designation 75 laid in trenches across the trench over the cable as cable protection complete all as directed by Engineer-in-Charge.
M&L for Tubes, 'light grade' galvanised 40mm dia, with all fitting and fixed complete to walls and ceilings or laid in floors / trenches / pole as in cable protection complete all as specified and directed.
OM SAI POWER SYSTEMS
M/s RAMA LAKSHMI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .