Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-AOC A P NIMGAON DAKU TAL KARJAT DIST AHMEDNAGAR | KARJAT | AHMEDNAGAR | MAHARASHTRA | L1 | Accepted-AOC Awarded Being Lowest Bidder | |
| 2 | L2₹36.7 L+₹1.2 L (3.38%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹37.5 L+₹2.0 L (5.62%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹38.7 L+₹3.3 L (9.22%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹40.3 L+₹4.8 L (13.6%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
23 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Provision of Toilet Block, Spl Repairs to Bldg No P-8, Sewage line and certain sanctioned works in the area of AGE B/R II under GE (N) Ahmednagar
2022_MES_510344_1
8597 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹79,000
Yes
4 Apr 2022
25 Feb 2022
25 Mar 2022
25 Feb 2022
23 Mar 2022
11 Mar 2022
60 days
Amount
Demolition of brick/ stone masonry built in cement or lime mortar etc complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floor & paving n.exc. 15cm thick below or above ground level etc complete all as specified and directed by Engineer-in-Charge.
Taking down cement mortar plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engineer-in-Charge.
Excavation in trences n.exc 1.5m wide and n.exc 1.5m in depth for foundation soft/disintegrated rock and getting out etc complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:4:8) type D2 (using 40mm graded aggregate) as in foundation /mass concrete etc complete all as specified and directed by Engineer-in-Charge.
M&L for hardcore or gauge of brokenstone or boulders n.exc 63mm, deposited spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface etc complete all as specified and directed by Engineer-in-Charge.
M&L for moorum filling in floors or paving laid in layers n.exc. 15cm thick spread levelled and rammed including watering etc complete all as specified and directed by Engineer-in-Charge.
M&L for P.C.C (1:4:8) type D-2 using 40mm graded stone aggregate, 75mm thick in sub base for floor etc complete all as specified and directed by Engineer-in-Charge.
Returning, filling including spreading levelling, watering and well ramming in layers n.exc 25cm in soft/loose and hard/dense soil.layers n.exc 25cm in soft/loose and hard/dense soil etc complete all as specified and directed by Engineer-in-Charge.
Removing excavated (soil) material n.exc 50m and depositing where directed at a level n. exc 1.5m above the starting point etc compete all as specified and directed by Engineer-in-Charge.
Rough finished wooden form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc compete all as specified and directed by Engineer-in-Charge.
Rough finished wooden form work to sides of pillars, posts, struts, piers, columns and Stanchions etc compete all as specified and directed by Engineer-in-Charge.
Rough finished wooden formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc compete all as specified and directed by Engineer-in-Charge.
Rough finished formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick(Horizontal or sloping) etc compete all as specified and directed by Engineer-in-Charge.
M&L for RCC 1:1½:3 nominal mix Type B1 using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc compete all as specified and directed by Engineer-in-Charge.
M&L for RCC 1:1½:3 nominal mix Type B1 using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC 1:1½:3 nominal mix Type B1 using 20 mm graded stone aggregate as in roof slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as spcified and directed by Engineer-in-Charge.
M&L for RCC 1:1½:3 nominal mix Type B1 using 20 mm graded stone aggregate as in Chajjas etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC 1:1½:3 nominal mix Type B1 using 20 mm graded stone aggregate as inBeams, cantilevers, bressummers,lintels over 1.5m span etc complete all as specified and directed by Engineer-in-Charge.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed by Engineer-in-Charge.
All as per Sl item No 20 (here-in-before) but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
M & L for 75mm thick PCC (1:3:6) type C-2 using 40mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mt centre to centre and at every turning & filling the joints with bitumen & sand mixture etc complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:2:4) type B1 using 20mm graded stone aggregate as in surface channels and drain etc complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:3:6 type C-1 using 20mm graded mechanically crushed stone aggregates as in cills, steps, bands, copings, bed plates, kerbs, hold fasts blocks etc including weathering slightly rounded or chamfered angles of throating including form work complete all as specified and as directed.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay etc complete all as specified and directed by Engineer-in-Charge. Notes: 1. Guard bar shall be measured and paid separetly as S&F 2. M&L for glazing shall be measured and paid separetly
M&L for 3.00 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 sqm in each pane etc complete all as specified and directed by Engineer-in-Charge.
M&L for 12 mm mesh, Wire netting of galvanised steel wire 0.71 mm dia fixed with tinned tacks of wire staples etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix mild steel butt hinges medium weight cold rolled of size 100mm etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix aluminium anodised barrel tower bolt of extruded section 150mm long etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix aluminium anodised handles of extruded section 150mm long etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for coloured glazed ceramic tiles digitally printed premium series of size exc 0.06 Sqm and n'exc 0.10 Sqm , 8-10 mm thick as approved by GE as in dado/skirting or on vertical surfaces, over and including 10 mm thick backing coat in cement and sand mortar (1:4) set and jointed in neat grey cement slurry and pointed in white or coloured cement to match the shade of floor etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for Anti skid ceramic coloured tiles to match dado tiles makes as specified in PS,7-8 mm thick as approved by GE (square / rectangular) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm, as in floor etc laid over and including screed bed 15 mm thick in cement and sand mortar (1:6) set and jointed in neat grey cement slurry and pointed with white or coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge.
M & L for 15 mm bore GI tubing medium grade with all fitting and fixed complete on walls and ceilings or laid in floors etc complete all as specified and directed by Engineer-In-Charge.
M & L for 20 mm bore GI tubing medium grade with all fitting and fixed complete on walls and ceilings or laid in floors etc complete all as specified and directed by Engineer-In-Charge.
S & F PVC connections 15 mm size with PTMT nuts of length 450 mm etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs stop cock cast copper alloy, fancy type screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fix of size 15 mm bore etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs tubular towel rail, brass chromium plated 20 mm dia `D' type, 60 cm long between flanges including a pair of brackets etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs bib tap, 15 mm dia, CP cast copper alloy with crutch or butterfly handle screwed down for iron pipe or for brass ferrule etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs 15 mm dia pillar tap, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe etc complete all as specified and directed by Engineer-in-Charge.
M&L cast iron floor trap with grating 75mm dia including jointing to waste pipe fixed in cement concrete type (1:2:4) type B1 using 20mm graded stone aggregate including removing old traps etc complete all as specified and directed by Engineer-in-Charge.
M&L for Grating doom 100mm dia of PTMT (Minimum weight 25gms) etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix wash hand basin vitreous China, ovel shape wall mounted of size 450 X 300 mm including a pair of brackets, PTMT waste coupling, 32 mm dia PVC flexible waste pipe and connecting to stop valve and nahani trap etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix PVC valveless, syphonic action type, flushing cistern,low level, all accesories etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix health faucet (hand shower) with 8 mm dia 1 m long flexible tube wall mounted / hooked etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing vitreous china wash down water closet (Pedestal pattern) white including fixing bolts with and including plastic water closet seat cover closed pattern with flat bottom and cover and MSCP almn hinges device complete connecting to 'P' or 'S' trap etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix 32mm dia powder coated chromium plated curtain rods incl brackets etc complete all as specified and directed by Engineer-in-Charge.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing etc complete all as specified and directed by Engineer-in-Charge.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing etc complete all as specified and directed by Engineer-in-Charge.
M&L Cutting out bricks, forming toothing for, and bonding new into old work including value of new materials entering old walls and jointing and pointing (measured on vertical face in contact with old wall only), in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge.
M&L for Pre-cast cement concrete block masonry of (1:3:6) type C-1 (20 mm graded stone aggregate) with solid blocks, exc. 10 cm in width complete set in and including cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of new steel surfaces of any description exceeding 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and directed by Engineer-in-Charge.
M&L for forming jambs, etc., to openings (to foregoing item), with stone supplied by MES including cutting, toothings and properly bonding into old work, including facing and pointing (if necessary) to match existing work, complete in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in cement and sand mortar (1:6) on any type of faces of brick work or concrete surfaces and finished even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in cement and sand mortar (1:4) on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement with WPC mixed at 2% of weight of cement used etc complete all as specified and directed by Engineer-in-Charge. Note : WPC will be measured and paid separetly
Supply only integral water proofing compound etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC (SWR) pipe 75 mm bore single socketed in any length with rubber ring fixed to wall with approved solvent/adhesive etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix powder coated aluminium two track sliding window made out of Jindal aluminium sections Nos. 20671, 20672, 20690 & 20668 including 5mm thick plain sheet glass for two shutters including rubber / neoprene beading and locking arrangement,aluminium fabric wiremesh 1.40 mm fixed to outer face of frame with suitable aluminium L section etc complete all as specified and directed by Engineer-in-Charge
M&L for rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410-W (Gde- E- 250) quality etc complete all as specified and directed by Engineer-in-Charge.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping etc complete all as specified and directed by Engineer-in-Charge.
Material and labour s&f false ceiling with Vinyle faced Arm-Gyp-FB, ceiling 600 x 600 x 9mm thick with washable metallized polyster foil backing with Vinyle covered edges, supporting sections shall be of suitable size from same makes embossed on sections and level adjuster duly suspended by 2 mm dia GI wire fixed to roof at 600mm centre to centre as per manufacturere's instructions / specification and all as directed including taking down/ out existing etc complete all as specified and directed by Engineer-in-Charge. Make : Armstrong or equivalent makes mentioned in list of makes in Appexdix `C'
Dismantling of stone slab & tiles of any description in floor, approx laid, bedded & pointed in any mortar. In any situation etc complete all as specified and directed by Engineer-in-Charge.
M&L for dark shaded Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, as in skirting, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including screed bed in cement and sand (1:4) etc complete all as specified and directed by Engineer-in-Charge.
M&L for 80 mm thick, PCC pavers interlocking tiles of glossy finish with white cement and pigment ,any shape & size conforming to IS 15658 of 2006. M-35 grade made up with 12.5mm graded mechanically crushed stone aggregates, factory made laid over and includig 30mm thick sand cushioning and joints filled with fine sand incl leveled with plate vibrator & sweeping etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for 150 mm bore SGSW drain pipe grade 'A' laid in trenches and jointed as specified including cement concrete bed to pipe including packing under and hauching against the sides of pipe in PCC 1:4:8 type D-2 using 40 mm graded mechanically crushed stone aggregates including making necessary connections after cutting into existing sewer line /manhole to make it functional after taking down/out salt glazed ware, AC or reinforced concrete pipe as existing at site etc complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:3:6 Type C-2 using 40 m graded stone aggregate in surface channels and drains etc complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced concrete pipes, class NP2, laid and jointed in cement & sand mortar (1:3) complete with collars 150 mm dia etc complete all as specified and directed by Engineer-in-Charge.
M&L for concrete bed to drain pipes in PCC 1:4:8 type-D2 using 40 mm graded aggregate including packing under, and haunching against the sides of pipes for 150 mm bore pipes after they are laid and tested; in
M & L for preparing new plastered surfaces of wall and applying two coats of OBD over a layer 2mm thick wall care putty, surface finished with roller finish on plastered surfaces of wall including preparation of surfaces etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces and appying three coats of white wash on wall etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces and appying three coats of white wash on ceiling etc complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surface of walls and applying two coats of cement paint external surfaces etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for providing water proofing treatment on roofs, as per manufecturer's instructions and as specified after taking down/out as existing at site :- (a) Cleaning the newly plastered surfaces with wire brushes and applying a coat of bituminous primer @ 0.30 ltrs/sqmts and allow to dry. (b) Applying and laying torch APP polymer modified bituminous membrance 3 mm thick with non woven polyster matt as reinforced weighing not less than 3 kg/sqmts by thermofusion process as per manufacturers specification including applying one coat of aluminium paint. Make : Super Thermolay of STP / Equivalent in Dr Fixit, FosRoc. Note : (i) Work has to be carried out strictly by the authonticated applicator of the manufacturer and as per manufacturers specification as approved by GE. (ii) Certificate from manufacturer shall be submitted by the contractor.
Material and labour for rendering, 15 mm thick on stone/brick / concrete surfaces in cement and sand mortar (1:4) surfaces finished even and smooth without using extra cement, including WPC @ 3% of weight of cement etc complete all as specified and directed by Engineer-in-Charge.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings etc complete all as specified and directed by Engineer=-in-Charge.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) etc complete all as specified and directed by Engineer-in-Charge.
M&L for 40 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregateas in sub base of floor etc complete all as specified and directed by Engineer-in-Charge.
M&L for Hand cut kota stone slab flooring 20-25mm thick laid over and including screed bed 15 mm thick in cement and sand mortar (1:6) set and jointed in neat grey cement slurry and pinted with grey cement and pigment to match the shade of stone slab including rubbing and mirror polishing etc complete all as specified and directed by Engineer-in-Charge.
M&L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over and including 10mm thick backing coat in cement and sand mortar (1:4) set and jointed in neat grey cement slurry and pointed with grey cement and pigmnet to mathc the shade of stone slab including rubbing and mirror polishing etc complete all as specified and directed by Engineer-in-Charge.
Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 20 mm thick screed bed in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge.
M&L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete including 20 mm thick screed bed in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for coloured glazed ceramic tiles digitally printed premium series of size exc 0.06 Sqm and n'exc 0.10 Sqm , 8-10 mm thick as approved by GE as in dado/skirting or on vertical surfaces, over and including 10 mm thick backing coat in cement and sand mortar (1:4) set and jointed in neat grey cement slurry and pointed in white or coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge.
Taking down Chowkats or frames with shutters (without taking off shutters from the frames) n.exc 1.5 sqm etc complete all as specified and directed by Engineer-in-Charge.
Taking down Chowkats or frames with shutters (without taking off shutters from the frames)exc 1.5 sq. m but n exc 4 sqm each etc complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:2:4) Type B-1 using (20 mm graded stone aggregate) in hold fast blocks and rafter bed blocks etc complete all as specified and directed by Engineer-in-Charge.
S&F for steel windows with side hung double shutters incl projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded etc complete all as specified and directed by Engineer-in-Charge. Notes: 1. Guard bar shall be measured and paid separetly as S&F. 2. M&L for glazing shall be measured and paid separetly.
Supply and fix 35mm thick second class hard wood plain framed factory made panelled shutters, two panel with lock rail and panel of 9mm BWP commercial ply. The size of rail and style as per IS 1003 (Part I) kiln seasoned and chemically pressured treated. etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section of cast aluminium alloy and fixed 300mm long etc complete all as specified and directed by Engineer-in-Charge
M&L for providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron etc complete all as speciifed and directed by Engineer-in-Charge.
Material and labour for preparation of new wood and wooden based surfaces of any description exceeding 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as speciifed and directed by Engineer-in-Charge.
M&L for preparation of old painted Wood or wood based surfaces of any description exc 10cm width or girth and applying one coat of synthetic enamel etc complete all as speciifed and directed by Engineer-in-Charge.
M & L for preparation of old plastered surface of wall and applying one coats of cement base paint etc complete all as speciifed and directed by Engineer-in-Charge.
M&L for preparation of old decorated plastered or unplastered surfaces of walls including cornices etc and applying one coat of white lime wash on walls etc complete all as speciifed and directed by Engineer-in-Charge.
M&L for preparation of old/new decorated plastered or unplastered surfaces of walls including cornices etc and applying two coat of white lime wash on walls etc complete all as speciifed and directed by Engineer-in-Charge.
All as per item No.94 (here-in-before) but on ceiling.
M&L for complete removal of existing treatment of walls or other plastered surfaces and preparing the surfaces and applying two coats of OBD (washable) over a layer of 2mm thick birla putty including preparation of surfaces and roller finish complete all as specified & directed by Engineer-in-charge.
Supply and fixing metal tubular dealineator made out of ABS round body fitted with 2 Nos 65 mm dia highly reflective reflectors made out of PMMA and mounted on 45/50 mm dia mild steel pipe of 600 mm height duly powder coated and thermo plastic elastomer 3 bands of green, red and yellow reflector radium tape of 25 mm wide strips with anti theft steel net for reflector protection including embedding in PCC 1:2:4 (150x150x300mm) type B1 using 20mm graded stone aggregate etc complete all as speciifed and directed by Engineer-in-Charge. Make : M/s Dark Eye, M/s Automat, M/s Siddhi Vinayak Enterprises, M/s Road Safety Marks.
Supply and fixing PVC tubular dealineator made out of ABS round body dark eye fitted with 2 Nos 65 mm dia highly reflective reflectors made out of PMMA and mounted on 45/50 mm dia mild steel pipe of 600 mm height duly powder coated and thermo plastic elastomer 3 bands of green, red and yellow reflector radium tape of 25 mm wide strips with anti theft steel net for reflector protection including embedding in PCC 1:2:4 (150x150x300mm) type B1 using 20mm graded stone aggregate etc complete all as specified and directed by Engineer-in-Charge. Make : M/s Dark Eye, M/s Automat, M/s Siddhi Vinayak Enterprises, M/s Road Safety Marks.
Supply and fixing cat eye reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions. (Reflector Red) etc complete all as specified and directed by Engineer-in-Charge Makes : M/s 3M, M/s Automat, M/s Siddhi Vinayak Enterprises, M/s Road Safetly Marks.
Supply and fixing cat eye reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions. (Reflector Yellow) etc complete all as specified and directed by Engineer-in-Charge Makes : M/s 3M, M/s Automat, M/s Siddhi Vinayak Enterprises, M/s Road Safetly Marks.
Supply and fix solar cat eye aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/0.3 watt one NI-ed rechargeable battery (1.2V/1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc complete all as specified and directed by Engineer-in-Charge Makes : M/s 3M, M/s Automat, M/s Siddhi Vinayak Enterprises, M/s Road Safetly Marks.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil. etc complete all as specified and directed by Engineer-in-Charge
M&L for Reinforced concrete pipes 200 mm bore, class NP2, laid and jointed in cement and sand mortar (1:3) etc complete all as specified and directed by Engineer-in-Charge
M&L for concrete bed to drain pipes in PCC 1:4:8 type-D2 using 40 mm graded aggregate including packing under, and haunching against the sides of pipes for 200 mm bore pipes after they are laid and tested; in etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC pre cast manhole cover slab in (1:2:4) type -B1 using 20 mm aggrgate incl necessary form work and set in cement and sand mortar (1:6), cover slabs (for man holes etc) etc complete all as specified and directed by Engineer-in-Charge
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc.
M&L for 20-25 mm thick shahabad stone slab floring,bedded and jointed in cement and sand mortar (1:6) and pointed in cement and sand mortar (1:3) laid over and including 15 mm thick screed bed of in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over & including 15 mm thick screed bed in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing convex mirror polycarbonate 18' mounted on 50 mm dia mild steel pipe of 1000 mm height duly powder coated and including embedding in PCC (1:2:4) (150x150x300mm) type B1 using 20mm graded stone aggregate etc complete all as specified and directed by Engineer-in-Charge Make as approved by GE.
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of PVC boxes and fixed with brass screws cup washer for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, etc complete Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etcMake of FRLSH Cable.
One light point controlled by switch 5 Amp single pole one way
One fan point controlled by switch 5 Amp single pole one way
One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch
One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board
All as per Item No 110 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase, Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board.
S&F switch piano flush type single pole, one way 5/6 Amp etc complete all as specified and directed by Engineer-in-Charge.
S&F Switch socket combination two in one, 5 Amp flush type 230V AC etc complete all as specified and directed by Engineer-in-Charge.
S&F Switch socket combination 5 Amp / 16Amp, five in one, 5 / 15 Amp 230V AC etc complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors etc complete all as specified and directed Engineer-in-Chage
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories PVC boxes (upto 12 module suitble for Mylinc series of Legrand including white plates with frame upto 12 module of make suitable for Mylinc Series ) for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, etc complete all as specified and directed by Engineer-in-Charge Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2.Wiring shall be done as per complaints recd from user only on required basis it is not necessary to do whole wiring of any whole bldg 3. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, ceiling lights, bulkhead lights, bldg security light etc.
One light point controlled by switch 5 Amp single pole one way
One fan point controlled by switch 5 Amp single pole one way
One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch
One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board
All as per Item No 120 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase, Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board
S&F Modular Switch, 6 Amp, one way, one Module. etc complete all as specified and directed by Engineer-in-Charge.
S&F Modular Switch, 16 Amp, onw way, one Module. etc complete all as specified and directed by Engineer-in-Charge.
S&F Modular Socket Outlet 6 Amp, 2/3 pin, combined two module etc complete all as specified and directed by Engineer-in-Charge.
S&F Modular Socket Outlet 6 Amp / 16 Amp - 2/3 pin combined two module etc complete all as specified and directed by Engineer-in-Charge.
S & F stepped type electronic fan regulator Modular type on the existing phenolic laminated sheet etc. as required etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directed by Engineer-in-Charge
M&L ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge
S & F in replacement double door Sheet metal enclosures factory made Vertical DBs 4 way TPN, 415 volts concealed in wall including 63 Amps MCCBs ,protection class IP-42, suitable for fixing of MCBs, etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. Make: Legrand ,Cat No:5076 70 or equivalent makes mentioned in list of makes in Appendix `C'.
S & F in replacement double door Sheet metal enclosures factory made DBs SPN, 8 way ,240 volts ,protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. Make: Legrand ,Cat No: 5076 11 or equivalent makes mentioned in list of makes in Appendix `C'.
S & F in replacement double door Sheet metal enclosures factory made DBs 4 way SPN, 240 volts ,protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. Make: Legrand ,Cat No:5076 10 or equivalent makes mentioned in list of makes in Appendix `C'.
Supply & fixing MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing MCBs, SPN, AC, 240 volts of 40 Amps capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 20 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge Make:Philips Model Name Astra line or equivalent makes mentioned in list of makes in Appendix `C'.
S&F Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 10 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with 2 core seathed copper conductor cable of size 0.5 Sqmm with etc complete all as specified and directed by Engineer-in-Charge.
Supply & fix replacemnt industrial type switch socket for Geyser/heater with 20 Amp MCB etc complete all as specified and directed by Engineer-in-Charge .Make L&T Cat No PMP120B or equivalent makes mentioned in list of makes in Appendix `C'.
S&F sub main wiring with two single core PVC insulated,unsheathed, FRLSH stranded copper conductor cable 4 Sqmm with 4 Sqmm PVC insulated, unsheathed, FRLSH stranded copper conductor cable as earth wire drawn through and including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. Two run of 4 Sqmm cable i.e for one run for phase, one run for neutral with one run of 4 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25 m depth and top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts & washer etc. Earth wire connected upto main earth point / DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 using granded stone aggregate and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of TMT bar @ 100 mm CIC, both way, lifting arrangement complete including all necessary earth work etc complete all as specified and directed by Engineer-in-Charge
M & L for Supply,laying ,connecting ,testing and commissioning and jointing , LT underground cable in replacement ,1100 volts grade, XLPE insulated, armored with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in ducts, fixed on poles/walls with proper size saddles and clamp complete all as specified and as directed by the Engineer-in-Charge of following Sizes :-
LT cable16 Sqmm, 4 core.
LT cable10 Sqmm, 2 core.
Supply &lay HDPE pipe 40 mm bore for laying of LT cable complete with all accessores etc complete all as specified and directed by Engineer-in-Charge Make.Supreme/Jain/Jindal
Supply and fix exhaust fan,steel body AC Single phase,230 V of size 300 m sweep with ,blades and frame and louvers 450 mm sweep heavy duty etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement energy saving and environmental friendly long life LED street light 25 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V , 50 HZ etc complete all as specified and directed by Engineer-in-ChargeMake -Havell's Cat Part: (ENDURAPEARLSL25W MP) ENDURAPEARLSL25WLED757SASYTOPCMP or equivalent makes mentioned in list of makes in Appendix `C'.
Supply and fix GI pipes, medium grade including necessary fittings such as sockets, elbows, tees, reducers, unions, nipples etc laid in trenches / walls / floors etc for the 50 bore pipe etc complete all as specified and directed by Engineer-in-Charge.
All as per serial item No 24 above but 25mm bore pipe
Material and labour in repairs gun metal gate valve/brass stop valve, high pressure both ends screwed down with crunch or butterfly handle with suitable size sockets on both ends nipples, unions, etc suitable for up to 25 mm bore GI pipe etc complete all as specified and directed by Engineer-in-Charge.
S& F in repairs high pressure brass valve with PVC ball suitale for fixing to GI pipe of 25 mm dia etc complete all as specified and directed by Engineer-in-Charge.
Drilling and tapping cast iron / ductile iron water mains, in position, for branch connections of the internal dia 20 to 50 mm all as directed.
Supply and fix in repairs cast iron sluice valve ,80 mm bore , Class PN1, ISI marked with stainless steel spindle, both ends flanged including rubber gasket, nuts, bolts and washers etc complete all as specified and directed by Engineer-in-Charge.
Dismantaling old valve chamber & M & L for Construction of PCC solid block valve chamber including earth work described as under complete all as specified for the following internal size as under : (a)100 mm thick hard core, (b)PCC foundation 1:4:8 type D2 (using 40 mm graded stone aggergate) (c) 200 mm thick block masonary graded C-5 built in CM 1:6, (d)15 mm internal and external plaster in CM 1:4, (e)3mm thick MS sheet chamber cover and 50 x 50 x 6 mm thick angle iron frame including painting with two coats of synthetic enamel paint over one coat of red oxide primer on all exposed surface including locking arrangments.
(a) Internal Dimension 1500 mm x 1200 mm x 1000 mm
Supply and fix GI pipes, medium grade including necessary fittings such as sockets, elbows, tees, reducers, unions, nipples etc laid in trenches / walls / floors etc for following pipe of dia etc complete all as specified and directed by Engineer-in-Charge
(b) 80mm bore
Material and labour for cast iron / ductile iron specials such bends of any type, radius and angle, tapers any type, straight, bend, increasing, decreasing or double socket etc, tail pices single branch, "Y" junctions, double branch, cross (all sockets or socket and spigot) collars, caps and plugs etc suitable for CI / DI pipes class LA upto 300 mm more pipes etc complete all as specified and directed by Engineer-in-Charge.
An amount of Rs 22,838.00.00 shall be deducted from 22BOQ on account of schedule of credit
Avinash B Kullal
M/s IBEX Engineers and Contractors
M/s. A P INFRA
M/s AG PATHAN
OM SAI ASSOCIATES
M/s. Sagar Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .