| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 and found in order | |
| 2 | L2₹28.5 L+₹3,365.88 (0.12%)Rejected-AOC | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹28.5 L+₹3,393.90 (0.12%)Rejected-AOC | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹28.9 L+₹46,549.50 (1.63%)Rejected-AOC ALIPURDUAR | ALIPURDUAR | WEST BENGAL | 735204 | L4 | Rejected-AOC Not being L1 | |
| 5 | L5₹30.8 L+₹2.3 L (8.19%)Rejected-AOC | L5 | Rejected-AOC Not being L1 |
Tender Value
Refer Docs
Closing Date
30 Apr 2021, 6:00 pmClosed
HQ 135 WE
HQ 135 WE C O 56 APO
SPL REPAIR TO BLDG NO P 15 OR MD ACCN OF ENGR REGT AT GS VIHAR UNDER GE S AKHNOOR
2021_MES_434356_1
CWE/JA-02/2021-22
Open Tender
Civil Works
Item Rate
180 days
Akhnoor
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE South
Exempted
11 Jun 2021
5 Apr 2021
3 May 2021
5 Apr 2021
30 Apr 2021
16 Apr 2021
5 Apr 2021 - 10 Apr 2021
Amount
Demolition of cement concrete (unreinforced) concrete in ground floors and paving n-exc 15cm thickness (below or above ground floors), complete all as specified and as directed by Engineer-in-Charge.
M&L cement concrete type B0 1:2:4 using 12.50 mm graded stone aggregate 25mm thick as in flooring levelling course etc., complete all as specified and as directed by Engineer-in-Charge.
M&L screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar 1:6, complete all as specified and as directed by Engineer-in-Charge.
M&L non-skid ceramic coloured designer pattern tiles 300x300mmx7mm thick in floors etc. set jointed in neat cement slurry and pointed in white cement or coloured cement to match etc., complete all as specified and as directed by Engineer-in-Charge.
S&F Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and as directed by Engineer-in-Charge.
All as per Srl Item No. 5 but as in skirting, complete all as specified and as directed by Engineer-in-Charge.
M&L for 750 mm wide cement concrete 1:3:6 type C2 using 20mm graded stone aggregate as in plinth protection joint filled with bitumen sand mixer, 50mm thick finished even and smooth without using extra cement , complete all as specified and as directed by Engineer-in-Charge.
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off the premises , complete all as specified and as directed by Engineer-in-Charge
Rendering 10mm thick on fair faces of brick work or concrete surface in CM 1:4 as for tiles screed bed backing , complete all as specified and as directed by Engineer-in-Charge.
M&L glazed ceramic coloured designer pattern tiles 300mmx 450mmx7mm or 300x200x7mm thick on vertical surface such as skirting, Dado etc. set and jointed in white colour cement, complete all as specified and as directed by Engineer-in-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc., complete all as specified and as directed by Engineer-in-Charge.
M&L for granite 20mm thick (table rubbed and polished) in cooking platform and like in cement mortar 1:4 including pointing in white cement(1:2) using marble dust and making holes in RCC slabs suitable for gas pipe with round edges where required, complete all as specified and as directed by Engineer-in-Charge.
Demolition for cement concrete exc 15cm thickness but above ground floor as in sunken floor, complete all as specified and as directed by Engineer-in-Charge.
Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required area not exc 150cm, complete all as specified and as directed.
S&F 32mm dia G I pipe as spout pipe 450mm long bevelled cut at both ends by making hole in walls sunken portion approx. above the R C C slab and finished the hole with cement plaster 1:2 to match with existing surfaces, complete all as specified and as directed by Engineer-in-Charge.
M&L cement concrete type B0 1:2:4 using 12.50 mm graded stone aggregate 25mm thick as in flooring with using 3% WPC etc. ,complete all as specified and as directed.
M&L PCC (1;2:4) type B-1 using 20mm graded stone aggregate as in sides of rounded or chamfered on edges of sunken floor, complete all as specified and as directed by Engineer-in-Charge.
M&L for 15mm thick rendering in 1:3 CM with using 3% WPC as in sunken portion complete all as directed.
M&L for applying evenly a tack coat of industrial bituminous 85/25 @ 1.20 Kg per square mtr including cleaning surfaces, complete all as specified and as directed.
M&L for cement concrete type E - 2, 1:5:10 (using 40 mm graded stone aggregate) as in sunken flooring, complete all as specified and as directed by Engineer-in-Charge.
M&L for 40mm thick Plain Cement concrete type B1 1:2:4 using 20 mm graded stone aggregate as in floor etc complete mixed with WPC @ 3% by weight of cement (WPC measured and paid separately) laid finished even and rough to receive plaster without using extra cement complete all as specified and as directed.
M&L grubbing up bushes, tree trunk portion nexc 10cm girth including cutting of trees/bushes grown in over wall and roofs digging out roofs and making good area of wall/roofs with PCC 1:3:6 type and using 20mm graded stone aggregate to grubbed portion, complete all as specified and as directed by Engineer-in-Charge.
M&L for repairing RCC projection chajjas, roof, facia etc. by necessary preparation, scraping, cutting, chiselling derusting and cleaning exposed reinforcement surfaces of damaged, loose RCC surfaces with cement concrete (1:1.5:3) using 12.5mm graded crushed stone aggregates and reinforcement with welded mesh of weight exc 2Kg per Sqm but n.exc 3Kg/Sqm (if required) with or without facia and finished with cement mortar 1:3 using coarse sand and work in patches area n.exc 5 Sqm and thickness RCC member n.exc 70mm incl necessary formwork and applying two coats of finishes to match with the existing surfaces at any height, complete all as specified and as directed by Engineer-in-Charge. (Note: Rate of welded mesh will be included in the quoted rate & no extra cost will be paid on this account.)
Dismantling brick tiles or terracing tiles single layer on roofs alongwith complete waterproofing treatment and making the surface clean and dust free, complete all as directed by the Engr-in -charge.
Applying cement slurry @ 3-00 Kg/Sqm over cleaned roof surface all as specified and directed.
M&L for 10mm thick screed bed in CM 1:4 mixed with water proofing compound @ 3% by weight of cement in order to maintain proper slope over existing roof surface for laying of APP based polymeric membrane finished even and smooth without using extra cement complete all as direceeted by the Engr-in-charge (Note water proofing compound shall be measured and paid separately).
M&L Water proof treatment on roof top with APP (Ataxic Poly Propylene) modified polymeric five layered membrane with central core of 100 micron high molecular high density polyethylene film, minimum weight not less than 3.0 Kg/ Per Square Metre, centre core is sandwiched on both sides by high quality polymeric mix with properties of high softening point, high heat resistance and cold resistivity to make it ideal for all water proofing treatment, with polymeric mix protection on both sides with 20 micron HMHDPE film, laid over one coat of bituminous primer conforming to IS: 3384, applied @ 0.40 Kg/ Per Square Metre and one coat of hot blown bitumen of 85/25 grade, conforming to IS:702, applied @ 1.20Kg/ Per Square Metre on prepared surfaces of roof, overlap should be not less than 150mm at ends and 75mm at sides, joints and overlaps uniformly bounded with LPG torch flame including applying of one coat of semi hot blown bitumen of 85/25 grade, @ 1.20 Kg Per Square Metre and fine screened sand in dry condition @ 0.50 Kg/ Per Square Metre after laying the membrane, complete all as specified and as directed by Engineer-In-Charge
M&L for Providing 20mm thick precast PCC tiles jointed & pointed flush in CM 1:3 over 15mm thick bedding layer of CM (1:6) using 5% creosote oil ,complete all as specified and as directed.
Taking down or up steel tubing and connections including cleaning for refixing or removal to store 15mm bore, complete all as specified and as directed by Engineer-in-Charge.
Taking down or up steel tubing and connection s including cleaning for refixing or removal to store 20mm bore, complete all as specified and as directed by Engineer-in-Charge.
S&F GI tubing 'medium grade' galavanised, with all fitting and fixed complete to walls and ceiling etc 15mm bore, complete all as specified and as directed by Engineer-in-Charge .
All as per Srl item No. 31 but 20mm bore, complete all as specified and as directed by Engineer-in-Charge .
S&F Bib taps chromium plated fancy type, cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed in repair 15mm bore, complete all as specified and as directed by Engineer-in-Charge.
S&F for wall mixer with provision of shower for mixing hot and cold water 3 in 1 fancy type brass chromium plated with long shank and cup screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fixed 15mm bore fixed.
S&F for stop cock fancy type chromium plated with cast copper alloy screwed down high pressure with or without lathered hot and cold with long screwed shanks and fly nuts fixed in repair 15mm bore, complete all as specified and directed.
S&F for wall mixer as in sink mixer 2 in 1 , cast copper alloy, with capstan head chromium plated screwed down high pressure with or without lathered hot or cold with long screwed shanks and fly nuts screwed for iron pipe 15mm bore, complete all as specified and directed.
S&F PVC connection 15mm bore size with PTMT nuts of length 45cm, complete all as specified and as directed by Engineer-in-Charge.
S&F as in repairs PVC valveless symphonic action type flushing cistern, low level white with inlet ball valve float and handle including brackets. 10 ltr capacity, complete all as specified and as directed by Engineer-in-Charge.
Brass chromium plated shower rose 125mm fixed in repair, complete all as specified and as directed by Engineer-in-Charge.
Ball valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe or brass ferrule and fixed in repair 20mm bore, complete all as specified and as directed by Engineer-in-Charge.
S&F for stainless steel with draining board made of 1.00mm thick sheet for kitchen with plug , washer waste pipe cast iron cantilever bracket connecting union overall size 915mmx 460mm with bowl size (410 x 355 x 175 ) mm, complete all as specified and as directed by Engineer-in-Charge.
S&F CP grating 150mm dia with centre hole, complete all as specified and as directed by Engineer-in-Charge.
M&L for PVC bath room cabinet of size 535 x 483 mm x 110 mm with mirror, complete all as specified and as directed by Engineer-in-Charge. (Make: Prayag ) or equivalent in any approved make.
S&F for stainless steel plate rack of superior quality size 36" x 30" with not less than 8 kg, complete all as specified and as directed by Engineer-in-Charge.
S&F Rotational moulded polythene water storage tanks(cylindrical vertical with closed top) tripple layered hoisted and fixed in position all as specified in SSR Part I 1000 ltr capacity incl dismantling of existing water tanks and removing to store, complete all as specified and as directed by Engineer-in-Charge.
S&F for Gun-metal, globe or gate valves, for bore dia of pipe in 20mm with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
Supply and fixing in repairs vitreous China squatting pattern Orissa pattern WC size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) but including lime concrete bedding, complete all as specified and as directed by Engineer-in-Charge. Make : HINDWARE / CERA / PARRYWARE
Supply and fixing vitreous China squatting pattern Orissa pattern WC size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) but including lime concrete bedding, complete all as specified and as directed by Engineer-in-Charge. Make : HINDWARE / CERA / PARRYWARE
S&F brass chromium plated tubular towel rail 20mm dia(D) type 60cm long between flanges, complete all as specified and as directed by Engineer-in-Charge.
S&F 32mm dia waste pipe for WHB, complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkhats or frame with shutter(without taking off shutter from frame) n. exc 1.5 Sqm , complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkhats or frame with shutter(without taking off shutter from frame) exc 1.5 Sqm and nexc 4 Sqm , complete all as specified and as directed by Engineer-in-Charge.
Pressed steel frames for doors of 1.25 mm thick sheet with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, provding mild steel 6mm dia thresh old bar and filling hollow of frame of following sizes of frame 125 x 60mm, complete all as specified and directed.
Pressed steel frame for doors of 1.25 mm thick sheet with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, provding mild steel 6mm dia thresh old bar and filling hollow of frame of following sizes of frame 105 x 60mm, complete all as specified and directed.
Plain cement concrete M-10(1:3:6), type C-0, (using 12.50mm graded crushed stone aggregate), nominal mix, as in cills, steps; plinth courses, string courses, lacing courses, copings, kneelers, apex stones, bed plates and in hold fasts or filling in hollow of steel frame, including necessary form work, complete all as specified and as directed by Engineer-in-Charge.
S&F Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet rein-forced with M.S. square tube supplying and fixing in opening as per specification and drawing, complete all as specified and as directed by Engineer-in-Charge.
Factory made steel window, box type, using ERW hollow 'P' section, comprising double frame for and including gauged and glazed skeleton shutter, jointed internally with flat iron 40x4mm complete including grill/ guard bars of 8mm square bars fixed horizontally @100mm C/C including mild steel hinges, handles, tower bolts, stops, lugs etc, complete all as specified and as shown in drawing No- CEUZ/TD-1304, sheet No- 1/3 to 3/3 and as directed, complete all as specified and as directed by Engineer-in-Charge.
S&F sheet glass ordinary quality and glazing with oil putty in square nexc 0.5 Sqm Each pane 3mm thick, complete all as specified and as directed by Engineer-in-Charge.
Figured glass pin head type glazed with oil putty in square n-exc 0.5 Sqm in Each pane 3mm thick, complete all as specified and as directed by Engineer-in-Charge .
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F factory made Plain framed panelled shutter (two panel) of second class hard wood with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of the rail and stile as per IS:1003(Part I), kiln seasoned and chemically pressure treated 35mm thick , complete all as specified and as directed by Engineer-in-Charge.
S&F factory made Glazed and skeleton shutters open rebated and prepared to receive (glass) gauze (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing gauze (glass) etc size of members of shutters as specified 35mm thick 2nd class HW, complete all as specified and as directed by Engineer-in-Charge.
S&F Galvanised Mild steel wire cloth. 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and as directed by Engineer-in-Charge.
Framed work as in doors or gate, coolers stand of angle or others section etc confirming to Fe 410-s, complete all as specified and as directed by Engineer-in-Charge .
Supply and fixing of cupboard shutter 20mm thick (style) factory made panel PVC incl chowkhat frame made out of m.s tubes 19 gauge for top and bottom rails m.s frame shall be covered with heated moulded plain colour PVC 'C' channel having a PVC sheet strip of 10mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail and bottom rail on either side 10mm (5mmx2) thick of 20mm and 20mm cross PVC sheet and as gap insert for top and bottom rail. Panelling for plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement supplying fixing in the frame at site as per specification and drawing as in repairs, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repairs 18/19 mm thick block boards, grade 1 quality, exterior grade, commercial type, fixed with screws to timber frame-work as in shelves of cupboard drawers etc complete all as specified and as directed.
S&F for external teak wood lipping, 6mm thick fixed with nails over block board or veneered particle board for
Preparation of new or previously untreated wood or wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and as directed.
Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome primer, complete all as specified and as directed .
S&F Aluminium anodised barrel tower bolts of extruded section and fixed 200mm long, complete all as specified and as directed by Engineer-in-Charge.
Aluminium alloy anodised sliding door with hasp staple(bolt type) and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolts of extruded section or cast aluminium alloy and fixed 250mm long, complete all as specified and as directed by Engineer-in-Charge.
Aluminium handles fabricated type anodised 150mm long, complete all as specified and as directed by Engineer-in-Charge.
300mm ordinary rat rail rod pattern spring including roller plate complete fixing mild steel spring, complete all as specified and as directed by Engineer-in-Charge.
Hasp and staple safety type aluminium anodised with mild steel hinges pin including bolt to hing plate and fixed with screw size 100mm, complete all as specified and as directed by Engineer-in-Charge.
Floor doors stoppers of aluminium alloy body and tenque anodised with hard drawn steel spring fixed in floor 150mm long, complete all as specified and as directed by Engineer-in-Charge.
S&F Butt hinges, medium weight cold rolled mild steel and fixed 100mm long, complete all as specified and as directed by Engineer-in-Charge.
S&F epoxy powder coated drapery rods of mild steel 25 mm dia with and including pair of fancy type finnals complete fixed as in repair, complete all as specified and as directed by Engineer-in-Charge.
Demolition of brick built in CM including all quoins arches pillars etc, complete all as specified and as directed by Engineer-in-Charge.
M&L Brick work with sub class 'B' bricks straight or curved in plane exc 6cm mean radius built in cm 1:6, complete all as specified and as directed by Engineer-in-Charge.
M&L Brick work with sub class 'B' bricks straight or curved in plane exc 6cm mean radius built in cm 1:6, but except bricks complete all as specified and as directed by Engineer-in-Charge.
Taking down cement plaster on brick or stone walls / ceiling etc including raking out joints hacking for key scrubbing down with water etc, complete all as specified and as directed by Engineer-in-Charge.
M&L 10mm thick plastering on fair faces of bricks or concrete surfaces finished even and smooth w/o using extra cement in CM 1:6, complete all as specified and as directed by Engineer-in-Charge.
M&L 5mm thick plastering on fair faces for concrete surfaces finished even and smooth w/o using extra cement in CM 1:4 on ceiling, complete all as specified and as directed by Engineer-in-Charge.
M&L 15mm thick plastering on other than fair faces of bricks or cone surfaces finished even and smooth w/o using extra cement in CM 1:4, mixed with water proofing compound @ 3% by weight of cement complete all as specified and directed.(Note water proofing compound shall be measured and paid separately).
M&L Preparing of new plaster surface of walls and applying three coats of white wash, complete all as specified and as directed by Engineer-in-Charge.
Preparation of new surface of wall with 3mm thick Birla putty on plastering surface and applying two coat of oil bound distemper white or coloured over a coat of primer on walls complete all as specified and as directed.
Preparation of old surface of wall with 3mm thick Birla putty on plastering surface and applying two coat of oil bound distemper white or coloured over a coat of primer on walls complete all as specified and as directed.
M&L for Preparing of new plastered surface and applying two coats cement base paints on walls, over a coat of cement primer, complete all as specified and as directed by Engineer-in-Charge.
Complete removal of existing treatment and applying two coats of cement base paint of walls over a coat of cement primer, complete all as specified and as directed by Engineer-in-Charge.
M&L Preparing of new plaster surface of ceiling and applying three coats of white wash, complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of old surfaces of ceiling including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc including cornices, pilasters etc (plastered or unplastered surfaces) and applying two coat of white (lime) wash, complete all as specified and as directed by Engineer-in-Charge.
Dismantling of 100mm dia cast iron or reinforced concrete drain pipes, jointed in cement motar and taking out from floors or walls, complete all as specified and as directed by Engineer-in-Charge.
Dismantling of 75mm dia cast iron or reinforced concrete drain pipes, jointed in cement motar and taking out of trenches, if required, complete all as specified and as directed by Engineer-in-Charge.
S&F 100mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls, complete all as specified and as directed by Engineer-in-Charge.
S&F 100mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, in floors, complete all as specified and as directed by Engineer-in-Charge.
S&F 75mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, complete all as specified and as directed by Engineer-in-Charge.
S&F 75mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls, complete all as specified and as directed by Engineer-in-Charge.
S&F bend (any radius) with ducks foot or heel rest of 100mm bore, complete all as specified and as directed by Engineer-in-Charge.
S&F bend (any radius) with ducks foot or heel rest of 75mm bore, complete all as specified and as directed by Engineer-in-Charge.
S&F branch pieces single ( equal or unequal, ordinary or inverted with, complete all as specified and as directed by Engineer-in-Charge parallel branch of bore 100mm.
S&F branch pieces single ( equal or unequal, ordinary or inverted with parallel branch of bore 75mm , complete all as specified and as directed by Engineer-in-Charge.
S&F 100mm dia CI P or S trap, complete all as specified and as directed by Engineer-in-Charge.
S&F 100mm CI floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), complete all as specified and as directed by Engineer-in-Charge.
S&F 150 x 100 mm dia SW Gully trap setting and jointing with cement mortar 1:1 complete all as specified and directed, complete all as specified and as directed by Engineer-in-Charge.
Demolition and breaking up drain pipes (Salt glazed stone ware, AC/PVC pipe n.exc 150 mm dia including all fittings complete all as directed.
S&F for 110 mm PVC (SWR) Rain water pipes single socketed in any length with rubber ring joints fixed to walls
S & F PVC (SWR) bends 110 mm dia
Supply only integral waterproofing compound .
Demolition of Reinforced cement concrete (reinforcement cut as required to facilitate demolition) Roofs slab of Stair case, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, by using RCC cutter machine including making up all neccessary repair as required during the cutting of slab complete all as specified and directed by Engr-in-Charge.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, ridges fixed with self tapping screws as specified.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws asspecified
Rolled sections as in Roof trusses (framed), purlins where connected to common rafters and running rails fixed with angle cleats or other connecting plates
M&l for Providing, plain cement concrete type B1 (using 20mm graded crushed stone aggregates as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed.
Demolition of Concrete (reinforced) of any description and in any position not otherwise specifically provided, complete all as specified and directed.
Pre-cast cement concrete 1:2:4 type B1 for cover slab of manholes etc using 20mm graded stone aggregate. Set in cement 1:4, complete all as specified and as directed by Engineer-in-Charge.
Mild steel bars 10mm dia and over TMT bars cut to length bent to shape reqd including cranking, bending spirally for hooping for columns hooking bends and binding with including mild steel wire (annealed) not-less than 0.9mm dia or securing with clips quality, complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; for laying Salt-glazed stoneware drain pipes, manholes, not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, complete all as specified and as directed by Engineer-In-Charge.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 150mm / 200mm bore, set in cement mortar, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10 (1:3:6), type C-2 (using 40mm crushed stone aggregates) as in bed to drain pipes of 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; after laying, complete all as specified and as directed by Engineer-In-Charge.
Salt-glazed stoneware drain pipes, internal dia 150 mm, laid in trenches and jointed in cement mortar 1:1, complete all as specified and as directed by Engineer-In-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed by Engineer-In-Charge.
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge.
Plain cement concrete (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-15 (1:2:4), type B-1, (using 20mm graded crushed stone aggregate), nominal mix, as in copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work, complete all as specified and as directed by Engineer-In-Charge.
Clearing of blocked SGSW/Cast Iron pipes/sewer lines of any dia and any types in horizontal or vertical position by rodding from WC to manholes, manholes to manholes, manholes to septic tank/soakage wells flushing with pressure jet of water after taking out existing manholes covers and putting back in original position after cleaning of lines including removal of sludge and other waste materials/blockage in drain pipe to outside unit area and spreading bleaching powder on top of septic tank /soakage well/manholes etc. to make hygienically fit, complete all as specified and as directed by Engineer-in-Charge.
Rendering 10 mm thick, on fair faces of brick or concrete surfaces, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in CM 1:4, complete all as specified and as directed by Engineer-In-Charge.
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in any type of soil cimplete all as specified.
M & L for hard core of broken stone boulders of guage n exc 63mm depositing spread and levelled in layers n exc 15cm thick watered and rammed to a true surface .
M&L 75 mm thick PCC 1:4:8 type D2 using 40 mm graded stone aggregate complete all as specified
Chequered cement concrete coloured tiles size 300mm x300mm x25mm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over 20mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified .
Taking down carefully aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pedants, regulators, sockets, light fitting etc. and making good the disturbed surfaces of walls/ floor etc matching with the existing surface, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories are in concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular box,top cover plate, blank plate,MS box,screws,washers and all modular electrical fixtures are to be used same make/brand only and shall be deemed in to included in quoted rate only.) (a) One light point controlled by one switch.
(b) All as per Srl item No. 134 but One ceiling fan controlled by one switch.
(c) All as per Srl item No. 134 but One exhaust fan controlled by one switch.
(d) All as per Srl item No. 134 but One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
(e) All as per Srl item No. 134 but One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
(f) All as per Srl item No. 134 but One bell/buzzer point controlled by one bell push.
(f) All as per Srl item No. 134 but One light point controlled by two 2 way switches.
All as per item No.137 above,but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for the following:- One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on independent board.
All as per item No.138 above,but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for the following:- One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on same board.
Supply & fixing modular type switch 10 Amps, single pole,1way,1/2 module,240V, ISI Marked complete all as specified and directed. Make Legrand (Arteor) or equivalent in any approved make.
Supply & fixing modular type switch 10 Amps , 2way,single pole,1/2 module,240V, ISI Marked complete all as specified and directed. Make Legrand (Arteor) or equivalent in any approved make.
Supply & fixing modular type bell push 6 Amps,1/2 module, single pole, 240 volts, ISI Marked Complete all as specified and directed. Make Legrand (Arteor) or equivalent in any approved make.
Supply & fixing modular type switch 16 Amps, single pole,1way,1/2 module,240V, ISI Marked Complete all as specified and directed. Make Legrand (Arteor) or equivalent in any approved make.
Supply & fixing modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module,240V,AC ISI Marked Complete all as specified and directed. Make Legrand (Arteor) or equivalent in any approved make.
Supply & fixing modular type socket 6 A/16 Amps, 6 Pin combined shuttered socket 2/3 module with light indication ,240V,AC ISI Marked Complete all as specified and directed . Make Legrand (Arteor) or equivalent in any approved make.
Supply & fixing red color lighting indication lamp 6 Amps, fixing on switch board,single pole,240volts,AC,50 Hz suitable for 1/2 module ISI Marked Complete all as specified and directed.
Supply & fix fan regulator modular type electronic, stepped type(01 to 4/5), 100 to 120 Watts,240Volts,AC,ISI marked complete all as specified and directed. Make Legrand (Arteor) or equivalent in any approved make.
Supply and fix call bell AC, 230 Volts single pole, multi music type ISI marked, complete all as specified and directed. Make Legrand (Arteor) or equivalent in any approved make.
Supply & fix angle lamp holder, insulated body with back plate for bulb complete all as specified and directed.
Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed
Supply & fix LED light fitting decorative box type 20 watt,85% energy efficiency,0.9 PF, inbuilt driver,pre-wired, and including providing PVC/Wooden solid round/square block -02 Nos and connecting up with twin core twisted copper wire from LED fitting to ceiling rose and removing old unserviceable fitting complete all as specified and directed. Make :- Havells cat part No LHEXBLP7PNIW020 or equivalent in any approved make.
Supply & fix LED decorative box type 10 watt light fitting energy efficiency,0.9 PF, inbuilt driver,pre-wired, and including providing PVC/Wooden solid round/square block -02 Nos and connecting up with twin core twisted copper wire from LED fitting to ceiling rose and removing old unserviceable fitting complete all as specified and directed Make :- Havells cat part No LUMILINEPLUSBS10WLED865SPCSS or equivalent in any approved make.
Supply & fix LED INVERTER batten 18w/20w decorative box type light fitting,charging time 10 hour,emergency backup time 4 hours,Driver efficiency >/= 85% energy efficiency,0.95 PF, inbuilt dry battery & driver,pre-wired,rated voltage 230Volts,50Hz and including providing PVC/Wooden solid round/square block -02 Nos and connecting up with twin core twisted copper wire from LED fitting to ceiling rose and removing old unserviceable fitting complete all as specified and directed. Make :- Halonix cat part No HLB-08-20-CW-INV or equivalent in any approved make.
Supply and fix LED bulb 9 watts, 240Volts,50Hz pin type and including removing old unserviceable item complete all as specified and directed
Supply and fix Energy saving decorative BLDC motor ceiling fan of size 1200 mm sweep,3 blade single phase, 230Volts,AC, 50Hz,supper enamelled copper wire,insulation class'B',rated power 26 watt, rated current 0.12 amps, rated speed 350 rpm power factor 0.90 min,air delivery 220 mtr cub,40 degree centigrade max, 130V low voltage,2 megs ohms insulation resistance,210 micro amps leakage current,1500 volts/5 seconds as approved colour/design and including hanging GI hook with necessary suitable MS clamps and connecting cable three core 0.75 sqmm round PVC sheathed from ceiling rose to fan connector and testing complete all as specified and directed. Make:-Havells Efficiencia Neo (BLDC 26 W) or equivalent in any approved make.
Supply and fix Exhaust fan 230 mm sweep metal body industrail type heavy duty electrical operated ,AC, 50Hz,ISI marked,900 rpm,IP-55 complete accessories including luvours and necessary fixing arrangements such as nuts, bolts & washers and connecting PVC sheathed copper conductor cable of size three core, 1.0 sqmm from ceiling rose to exhaust fan connector complete all as specified and directed. Make:- Havells -Ventil Air -DSP or equivalent make in approved
Taking down old unserviceable ceiling fan of any type/size from existing location and deposit in MES store yard and Supply and fix ceiling fan of size 1200 mm sweep,high speed, single phase, 240Volts,AC, 50Hz,as approved colour and including hanging GI hook with necessary suitable MS clamps and connecting cable three core 0.75 sqmm round PVC sheathed from ceiling rose to fan connector and testing complete all as specified and directed. Make:-Havells model No. ES-50 or equivalent make in approved
Supply & fix sheet metal enclosure, double door 415 volts AC, MCCBsTPN distribution board 4 way vertical type (conforming to IS-8623 as amended ) painted with epoxy based powder coated painting suitable for flush mounting with 100amps copper busbar, 2 neutral/earth bar fully insulated and cable ties for pre-wired, door earthing,Corner sheild for better protection,pan assembly for ease of installation,masking sheet and MCCB incomer of rating upto 100Amps ,MCCB TPN/TP, and MCB SP/SPN/DP as outgoing and complete connecting cable links with top and bottom removable gland plate reversable doors for IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour shade all as specified and as directed. Make :- Legrand cat part No 5076 80 4 way, 8+12 module or equivalent in any approved make. Note:- MCCB/RCCB/ELCB as incomer and MCB SP/SPN/SPD as out going shall be measured and paid separately
Supply & fix sheet metal enclosure acrylic door 240 volts AC,SPN distribution board 8 way (conforming to IS-8623 as amended) painted with epoxy based powder coated painting suitable for flush mounting with 100amps copper busbar,neutral bar,earth bar fully insulated and cable ties for pre-wired, door earthing, Corner sheild for better protection,pan assembly for ease of installation,masking sheet and MCB incomer of rating upto 100Amps ,MCB SPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate reversable doors for IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour shade all as specified and as directed. Make :- Legrand cat part No 5076 21 8 way, 8 module or equivalent in any approved make.
Supply & fix MCB SP 6 to 32 Amps 10 KA,"C" series,AC,240Volts,50Hz , ISI marked complete all as specified and directed.
Supply & fix MCB SPN 40 -63 Amps 10 KA, AC,240Volts,50Hz, ISI marked complete all as specified and directed.
Supply & fix MCCB FP 100 Amps, 16 KA,"C" series,AC,415Volts,50Hz, ISI marked complete all as specified and directed.
Supply and fix sheet steel enclosure metal clad plug and socket including MCB SP 20 Amps, 10KA 'C 'series, 230 Volts suitable for Geysers and including making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and directed.. Make :- Legrand cat part No 5078 11 20 A SP 2P+E or equivalent in any approved make.
M & L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade,FRLSH type, PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat and applying putty including cutting and cheasing and complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
Earthing complete with galvanised steel earth plate electrode size 600x6x6mm buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised earth lead 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by GI protection pipe light grade 15mm dia connected to main earth wire on pole or control board and GI pipe light grade 20 mm bore for watering, funnel with wire mesh. PCC chamber pit in PCC 1:3:6 type C-1, 40mm thick precast RCC M-25 (design Mix) cover reinforced with 8 m dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50m complete all as specified and shown in electrical plateNo 05 of SSR part -I (2009), connecting to earth test point all as specified and directed including testing on completion. Note:- (i) The unit rate includes for protection pipe and earth lead upto 7.5 mtr (ii) Any Variation in length of earth lead and protection pipe beyond 7.5 mtr shall be measured seperately. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional height of watering pipe bends elbow etc shall be deemed to be included in the unit rate.
CHOPRA CONSTRUCTIONS
M/s Akhilesh Trading Co.
M/s Shivam Construction Co
M/S Rajesh Kumar Contractor
M/s Joginder Lal Malhotra
JR CONSTRSTRUCTION CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .