Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC GUDSATHU BUDGAM KASHMIR 191111 J K | BUDGAM | BUDGAM | JAMMU AND KASHMIR | 191111 | L1 | Accepted-AOC Being L1. | |
| 2 | L2₹6.5 L+₹79,800 (13.9%)Rejected-Finance | L2 | Rejected-Finance Other than L1. | |
| 3 | L3₹7.7 L+₹2.0 L (34.1%)Rejected-Finance | L3 | Rejected-Finance Other than L1. |
Tender Value
₹8.8 L
EMD Value
₹17,580
Closing Date
22 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 134 Wks Engrs
HQ 134 Wks Engrs PIN-914134 C/o 56 APO
REPAIR AND MAINT OF HT EXTERNAL ELECTRIC REPLACEMENT OF HT CONDUCTOR AND UG CABLES AT SHARIFABAD MIL STN UNDER AGE (I) CIF (K)
2023_MES_605548_1
134WE-17(T) OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
UNDER AGE (I) CIF (K)
As per Tender Documents.
9 documents required · 9 mandatory
₹500
AGE (I) CIF (K)
₹17,580
Yes
17 Aug 2023
24 Jun 2023
24 Jul 2023
24 Jun 2023
22 Jul 2023
10 Jul 2023
26 Jun 2023 - 1 Jul 2023
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 mtr deep, for laying cables/ pipes/ poles/stay etc and getting out in hard/ dense soil, complete all as specified and directed.
Returning, filling in, spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed.
Removing surplus material (soil) to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.50 mtr above the starting point, complete all as specified.
M&L for dry river sand, laid in trenches for cable protection, as 15cm thick below the cable and 8cm thick above the cable, complete all as specified and directed. Note :- Punned thickness of sand shall be measured & paid.
M&L for sub class 'B' brick old size covering protection to the eletric cable, laid dry, flat, transversally along the length of cable on sand cushioning with width equal to length of brick, complete all as specified and directed.
M&L for 80mm bore GI water tubing, light grade for road crossing, cable protection, laid in trenches or fixed to wall with suitable MS clamps and including taking up or down old exisiting tube, complete all as specified and directed.
M&L for 100mm bore GI water tubing, light grade for road crossing, cable protection, laid in trenches or fixed to wall with suitable MS clamps and including taking up or down old exisiting tube, complete all as specified and directed.
Supply and laying 40mm to 80mm graded coarse aggregate (broken stone or boulders), laid in sub station yard, complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in coping etc, rounded and chamfered on edges including necessary form work, complete all specified and directed.
Dismantling existing old unserviceable ACSR or ACC conductors of any size and any description, complete all as specified and directed.
S&F new ACSR conductor including stringing through existing RCC/ steel poles, fixing in insulators, jumpers with polythene pipe, copper binding wire etc. complete of different sizes, complete all as specified and directed. Note :- Rates for new aluminium tape / copper binding wire shall be deemed included in quoted rates.
S&F in replacement of mild steel cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed by Engr-in-Charge.
Dismantling inslulators of any type and size, complete all as specified and directed.
S&F in replacement disc type porcelain vitreous brown or white insulator, suitable for 11 KV HT working pressure, size 145mm height and 255mm dia including one galvanised mild steel spindle, two galvanised iron washer and one GI nut, complete all as specified and directed.
S&F in replacement pin type porcelain vitreous brown or white insulator, suitable for 11 KV HT of working pressure, size 150mm height and 150mm dia including one galvanised mild steel spindle, two galvanished iron washer and one GI nut, complete all as specified and directed.
S&F in replacement drop out (DO) fuse unit, expulsion type, outdoor three pole 200 Amps suitable for HT 11 KV, comprising of 6 Nos post insulators, GI steel base mounting frame, GI nut bolts etc. with 30A, HT barrel type fuse, complete all as specified and directed.
S&F in replacement transmission class type drop out fuses 11000 volts rating 25-50 Amps, outdoor type, complete all as specified and directed.
Taking down tripple pole mechanism complete with DO Fuse unit from the site and Supply and Install new DO fuse unit triple pole, mechanically operated, mounted on insulator and steel frame with opertaing mechanism worked from ground level with GI pipe medium grade, for current rating upto 200 Amps and air break (switch) insulator suitable for HT 11 KV, outdoor type 50 Amps (DO Fuse), complete all as specified and directed.
S&F in replacement lighting arresters expulsion type complete with all fittings transmission class, suitable for 11 KV volts and discharge capacity 65 Kilo Amps, complete all as specified and directed.
M&L in repair cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm, complete all as specified and directed.
M&L in repair cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 sqmm, complete all as specified and directed.
M&L in repair cable jointing kit for 11 KV (Earthed) grade cable for indoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm, complete all as specified and directed.
M&L in repair cable jointing kit for 11 KV (Earthed) grade cable for indoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185sqmm, complete all as specified and directed.
S&F in replacement cable jointing kit for 11 KV (Earthed) grade cable, Straight through joint, heat shrink type joint, complete with jointing material and accessories, suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm, complete all as specified and directed.
S&F in replacement cable jointing kit for 11 KV (Earthed) grade cable, Straight through joint, heat shrink type joint, complete with jointing material and accessories, suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and directed.
Supply, laying, testing and commissioning XLPE cable, PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), of size 3 core 95 Sqmm, laid in trenches / floor / duct throgh GI pipe, complete all as specified and directed.
Supply, laying, testing and commissioning XLPE cable, PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), of size 3 core 120 Sqmm, laid in trenches / floor / duct throgh GI pipe, complete all as specified and directed.
Re-stringing only existing HT 11 KV / LT OH line / Jumpers including dismantling of existing old binding wire for tightening, complete all as specified and directed. Notes :- (a) Re-stringing of each wire shall be measured as in RM. (b) New binding wire shall be measured and paid separately under respective item of this BOQ.
M&L for removing vegitation, grass, scrubs, creepers and bushes growing in Sub Station yard, around the poles/ stays, along with fancing etc. by manually / mechanically and keep the sub station yard neat and clean, complete all as specified and directed. Note :- Quoted unit rates shall be included to keep the installation neat and clean through out the period of contract and each cleaning shall be measured and paid separately.
M&L for cutting and trimming of tree branches of girth 25mm to 75mm upto 3 mtr all around of any size which is obstructing illumination of street light and touching LT / HT OH line by using required tools and plants including removing trimmed tree branches, complete all as specified and directed. Notes :- (a) Each cleaning/ cutting shall be measured and paid separetely. (b) All T&P and machineries shall be included in quoted rates.
Supply and filling fresh transformer power oil of BDV not less than 50 KV for topping up of reduced level of transformer due to evaporation / leakage / losses due to dehydration in HT 11KV distribution transformer 100 to 600 KVA and including removing / taking up old unservicable transformer oil, complete all as specified and directed.
M&L for conducting oil filtration by stream line / vacum type filter machine to remove the moisture / carbon particles to improve required BDV of oil 50 to 60 KV for 1 min for power transformer and as BDV of oil 40 to 50 KV for 1 min for distribution transformer including routine testing after filtration for any capacity of transformers / AVR / CT / PT units, complete all as specified and directed. Notes :- (a)The contractor shall change the filter assy before starting the filtration of transformer / AVR of any capacity in presence of Engr- in-Charge. (b) Necessary documention should be submitted by the contractor to Engr-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick, burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to the Galvanised iron strip of size 25mm x 4mm by means of bolts, nuts, check nuts and washers, protected by GI tube light grade of 40mm bore including provision of concrete pit in PCC 1:2:4 type B-1 with 40mm thick cover of RCC (1:2:4) reinforced with XPM, weight not less than 4 Kg /Sqm and 6mm dia round bar handle, excavation and earth work in any type of soil, charcoal dust and salt, 20mm bore GI watering pipe of light grade with funnel and wire mesh, complete all as shown in electrical plate No 3 of MES SSR Part-I (2009) and all as directed by Engr-in-Charge. Notes:- (i) Main earthing strip from earth plate electrode to test point upto length of 7.5 metre shall be deemed to include in the quoted rate. (ii) On testing after completion if desired resistance is not obtained, the contractor shall redone the earthing without any extra cost to the department.
Notes :- An amount of Rs. 45,950.00 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum.
M/S Noor Mohammad Shalla
M/S N A Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .