Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.7 LAccepted-AOC 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹47.4 L+₹69,061 (1.48%)Rejected-Finance 512 227 5TH LANE NISHANTGANJ LUCKNOW 226016 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226016 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹49.8 L+₹3.0 L (6.50%)Rejected-Finance RAJEEV NAGAR KUTIA GHUSIYANA KHARIKA TELIBAGH LUCKNOW | LUCKNOW | LUCKNOW | UTTAR PRADESH | L3 | Rejected-Finance Being L3 |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
1 Apr 2024, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
PROVN OF STORAGE SHEDS FOR MED STORES, SPECIAL REPAIR / REPLACEMENT OF AIR CONDITIONER, CIELLING FANS, EXHAUST FANS AND WALL MOUNTED FANS AGAINST BER AND PROVN OF 03 X SOLAR WATER HEATING SYSTEM OF 200 LITRES CAPACITY FOR SINGLE LIVING JCOS ACCN P-1
2024_MES_645185_1
GE/EM/LKO/HOSP/T-01 OF 2024-2025
Open Tender
Civil Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹95,000
Yes
7 Jun 2024
5 Mar 2024
3 Apr 2024
5 Mar 2024
1 Apr 2024
20 Mar 2024
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation, / laying of pipe / cable etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft loose soil complete.
Returning, filling in including spreading levelling watering and well ramming in layer n.exc 25 cm thick using excavated soil all as specified and directed.
Removing excavated soil to a distance not exc 50 m and depositing where directed at level n exc 1.5 m above the starting point.
M&L for Brick work with Fly ash brick designation 100 Kg / Sqcm, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, using bricks of size 230 mm x 110 mm x 70 mm confirming to IS 12894, complete all as specified and as directed by Engineer-in-Charge.
S&F 0.50 mm thick Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall or roof, fixed with self tapping screws as specified and as directed by Engineer-in-charge
S&F 0.50 mm thick Pre- painted galvatume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof ridge / cladding to wall or roof, fixed with self tapping screws as specified and as directed by Engineer-in-charge
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240
M&L for preparing new steel steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
M&L for RCC 1:2:4 type B1, using 20 mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels & similar RCC works all as specified and directed.
S&F mild steel work as in hold fasts and similar articles conforming to Fe.290.Gde-E-165
M&L for Cement concrete type D2 1:4:8 (using 40mm graded stone aggreages) as in foundations, filling and mass concrete all as specified and directed.
M&L for Rendering 15 mm thick in cement and sand mortar 1:4 on brick work or cement concrete wall surfaces including mixing only water proofing compound as per manufacturers instruction and finishing the surface even and smooth without using extra cement complete all as specified. Note:- Waterproofing compound will be measured and paid seperatly.
M&L for Rendering 10 mm thick in cement and sand mortar 1:6 on brick work or cement concrete wall surfaces including finishing the surface even and smooth without using extra cement complete all as specified.
Supply only integral WPC of approved quality
M&L for preparation of new plastered surface of walls and applying two coats exterior emulsion weather coat paint of make Apex (Asian Paint) / Weather coat (Berger) / Excel Top Guard (Nerolac) over one coat primer with 2 mm thick cement base wall care putty complete all as specified and directed.
M&L for preparation of new plastered or unplastered surface of walls and applying three coats of white wash all as specified and directed.
M&L for 40 mm thick cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) Damp proof course to horizontal or vertical surfaces including necessary formwork and including mixing only water proofing compound as per manufacturers instruction complete Note:- Waterproofing compound will be measured and paid seperatly.
M&L for 40 mm thick PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in floor, finish the surface even and smooth without using extra cement complete.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil
M&L for Steel door including projecting type hinges, steel handle, complete, with glazing bars, dovetailed or welded complete all as specified and directed
M&L for Steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel, complete
M&L for Sand filling under floors or in foundations including watering and consolidation complete.
S&F Mild stee bars (TMT bars) 10 mm dia and over as in reinforcement cut to length, bent to shape required including cranking hooking ends and binding with mild steel wire [annealed] not less than 0.9 mm dia or scruing with clips.
Use & waste Form work to sides and soffits of floor or roof beams, lintiles cantilever etc for rough finished surface complete all as directed.
M & L for 75 mm thick plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection, surfaces finished even and smooth without using extra cement all complete all as directed by Engineer -in-charge.
M&L for Hardcore of gauge n exc. 63 mm, of broken bricks, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface.
Supply, installing, commissioing and testing , non-inverter type split Air Conditioner of capacity 1.5 TR with inbuilt ioniser and plasma filter for better air quality, front panel display, wireless LCD remote control, precoated aluminium fins, 5 star rated, electric driven, suitable for working on 230 volts, single phase, 50 Hz supply complete including cutting of wall, providing stand for out door unit and making good disturbed surface of wall complete, all as specified and directed.
Supply, installing, commissioing and testing , non-inverter type split Air Conditioner of capacity 2.0 TR with inbuilt ioniser and plasma filter for better air quality, front panel display, wireless LCD remote control, precoated aluminium fins, 5 star rated, electric driven, suitable for working on 230 volts, single phase, 50 Hz supply complete including cutting of wall, providing stand for out door unit and making good disturbed surface of wall complete, all as specified and directed.
Supply & fix ceiling fan 1200 mm sweep, BLDC copper wound motor, AC single phase, 230 volts, white colour complete with fan blade, down rod, canopy and provn of connection with three core flexible copper wire cable of size 1.50 sqmm from ceiling rose to fan, writing of MES Nos as approved size of letter complete all as specified and directed.
Supply & fix exhaust fan metal body 300 mm sweep, 900 RPM, copper bound motar, AC 230 volts, single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size, fixed in existing opening including testing, writing of MES Nos of approved size of letter complete all as specified and directed.
Supply & fix 300 mm sweep fresh air ventilator fan, PVC body & PVC blade, 230 Volt, 50Hz, single phase AC supply, with PVC louvers fixed in position and connecting with ceiling rose, writing of MES Nos of approved size of letter complete all as specified and directed.
Supply installation, testing & commisioning of solar water heating system of capacity 200 litres consisting of flat plate collector box fabricated from aluminium extruded partion by means of gas welding or brazing leak proof with supporting structure angle iron of size 50 x 50 x 6mm duly powder coated paint, provided with absorber made from copper tubes with protective coating, with header grommet, storage tank made from stainless steel sheet of minium 20 gauge thickness with puff insulation of minium 50mm girth outer including of 55-26 SWG brass socket and nipple with cold and hot water piping, gun metal valves, coil type stainless steel heat exchanger complete conforming of IS-12933 & 12976 with necessary wiring fixed on and including required size PCC platform, mild steel framed work for supporting structure and 3 kw electric backup complete all as specified & directed.
S&F mild steel framed work such as grills gratings etc with ends of bars shouldered and / or riveted or forged into spiked framed guard bars barred iron doors ladders framed balusters walkways railings framework for staging of water tanks and similar work conforming to Fe 290 Grade E-165
Supply and fix 500 litres capacity triple layer (white), rotational molded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof / staging in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 25 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete.
Supply & fix hot water composite pipe (PE-AL-PE) 20 mm bore, ISI marked, including tee, elbow and other jointing materials etc complete all as specified and directed.
Supply and fix 25 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc laid in trenches complete and connecting to water supply pipe line all as specified and as directed by Engineer-in-Charge.
Supply and fix 25 mm size Gun-metal glove or gate valves, with iron wheel head, screwed both ends for iron pipe all as specified .
Material & Labour for concealed / surface type sub main wiring with 2 run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC rigid conduit not less than 25 mm dia and 1.8 mm wall thickness with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) as earth wire, fixed on wall / ceiling complete. Note: (i) 2 Runs of main cable and one run earth wire with conduit will be measured as one RM for payment. (ii) Cutting chase wherever required will be measured & paid separately
M&L for Cutting chases, of girth not exceeding 10 cm for concealed water tubing or concealed conduit wiring, etc. in stone / brick masonry wall built in cement mortar and making good, disturbed surface in Cement mortar 1:3 complete.
Supply and fix metal clad single pole and earth enclosure with two pin and earth plugs and socket complete with one single pole MCB 10 Amps, 250 V, C type complete.
S&F 15 mm size bib taps cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipes complete.
Material & Labour for conceled point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable of green colour as a earth wire connected to common earth dolly, etc including pressed steel terminal box of suitable size with laminated white top sheet cover of 3.00 mm thick complete. Note: (i) Cutting chase wherever required will be measured & paid separately
All as per Item No 42 above but for one 5 pin 5 Amp socket outlet point on an independent board.
All as per Item No 42 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50sqmm and green colour earth cable of size 2.50sqmm.
S&F Polycarbonate switch piano flush type, SP,5/6 Amps, one way complete all as specified &directed
S&F Polycarbonate switch piano flush type, SP, 16/20 Amps, one way complete all as specified &directed
S&F Polycarbonate socket out let 2 in 1 socket 5 pin, (6 Amps) flush type controlled by one switch,complete all as specified &directed
S&F Polycarbonate socket out let 6 pin, 20 Amps complete all as specified. & directed
S&F ceiling rose polycarbonate body surface type three terminal complete as directed.
S&F epoxy powder coated distribution box Double door type SPN 8 way,with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door all as specified and directed.
S&F MCB, single pole 6 to 32 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB, single pole & neutral 40 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
M&L of Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of nut, bolts, check nut & washer of galvanized iron or of steel, earth lead protected by 15 mm dia GI pipe light grade, watering pipe 20 mm dia GI light grade, GI wire mesh, GI funnel, alternate layer of char coal and salt, PCC chamber, recessed for and including RCC cover including all necessary excavation & earth work, earth wire 7.5 mtr connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 complete all as specified and directed .
Supply and fix wall / surface mounting luminaires integrated LED Batten (4 feet) 20 W, 6500 K, 230V , system efficiency not les than 100 lumens / watt, with extruded aluminium housing with frosted PMMA / PC diffuser & integrated electronic driver fixed in position and connecting with ceiling rose complete all as per specified and directed by Engr-in-charge.
S&F Lamp holder battern / anguler type, polycarbonate type with cord grip cap suitable for pendant fittings .
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium conductor 1100 volt grade of size 10 Sqmm, 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed. Note:- Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose punned thickness of sand will be consider.
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge.
Divya Jyoti Constructions
NAVJYOTI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .