| 1 | L1₹22.3 LAccepted-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L1 | Accepted-AOC ACCEPTED DUE TO LOWEST | |
| 2 | L2₹24.7 L+₹2.4 L (10.8%)Rejected-AOC FLAT NO 06 BLDG NO B 2 PLEASANT PARK WANWADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L2 | Rejected-AOC REJECTED DUE TO NOT LOWEST |
Tender Value
₹26.7 L
EMD Value
₹53,500
Closing Date
3 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) LOHEGAON
GE (AF) LOHEGAON, PUNE -411032
PROVN OF CERTAIN EM MINOR WORKS AND MAJOR REVENUE WORKS AT 2 WING AND 9 BRD AF STN PUNE.
2022_MES_501731_1
8541/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) LOHEGAON
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) LOHEGAON
₹53,500
Yes
30 Mar 2022
15 Jan 2022
10 Feb 2022
15 Jan 2022
3 Feb 2022
22 Jan 2022
60 days
Amount
Supply and fix air termination single pointed aluminium 12 mm dia & 300 mm long including nuts & bolts for fixing air termination rod to pole/ pipe duly insulated by providing appropriate insulator all as required at site complete all as specified and directed.
S&F GI pipe medium grade 40 mm dia embeded in concrete complete all as specified and directed.(mounting arrangment for air termination) Note: M&L for PCC work will be measured and paid separately.
Supply and fix socket reducer 40x25 mm and aluminium gukta externally threaded suitable for fixing terminal rod complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as mass concrete for foundation of GI tubing, air termination rod, pole, stay foundation complete all as specified and directed.
S&F aluminium strip 25 x 3 complete with saddles and fixing screwes for roof conductors down conductors complete all as specified and directed.
S&F epoxy insulators suitable of aluminium strip of 25x3mm size with nut bolts/ screws for fixing of copper/ aluminium / GI strips on stone / PCC block walls etc complete all as specified and directed. Note : Distance between insulators shall not be more than 1 meter.
S&F test point terminal block made out of gun metal or phosphorous bronze size 75x75x25 mm depth , drilled , cutting upper & lower portion for incoming & outgoing including double insulators two coat of synthetic enamel paint complete all as specified and directed.
Material and labour for supply, installation, testing and commissioning of GI pipe electrode earthing maintenance free earthing based on 3 mtr long GI pipe 80 mm dia(ID) medium grade, GI strip 32x6 mm (Strip in pipe type electrode) and GI pipe electrode shall be filled with MFC for improvement of conductivity of electrode, 120 KGS approx of BFC shall be filled around the GI pipe electrode.Rate included for testing,commisioning including checking of earth continuity and earth result complete all as specified and directed. GI strip required for interconnection of GI electrode to test point must be laid 2 ft below the ground level and the same must be treated with chemical (BFC). Rate is included for boring of earthing in any type of soil/rock upto 200 mm bore. The resistance value of earthing must be less than 5 ohm, Continuity of good earth resistance shall maintained upto 1 year and testing will be carried out monthly by MES authority.GI strip must be connected with GI pipe electrode and other joints through nut bolt in addition to welding. Note:- (i) Earth strip from top connector of electrode to test point and further connection to LT panel/AF equipments/ for grid of earthing shall be measured and paid separately. (ii)The resistance value of earthing must be less than 5 ohm , the cost ofany extra work required to achieve the result must be included in the quoted rate.
M&L for earthing chamber of size 450x450x300 mm depth outside & 250x250x300 mm depth inside of PCC (1:3:6) type C2 complete all as specified and directed.
S&F of earthing pit cover 50 mm thick precast slab of RCC 1:2:4 type B1, reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm incl 6 mm dia bar handle complete all as specified and directed.
S&F earth continuity conductor fixed to walls or burried in ground or drawn in pipe of size 32x6 mm galvanised iron strip complete all as specified and directed.
M & L for cutting of existing GI tubing medium grade of size upto 80mm and insertion of 'T' taking connection for earthing pipe line for water arrangement including cutting threading and inclusive all fitting complete all as specified and directed.
Supplying, laying and jointing threading into trenches/wall/floor etc 25 mm bore medium grade GI steel water tubing incl all fittings and accessories complete all as specified and directed.
Supplying, laying and jointing threading into trenches/wall/floor etc 15mm bore medium grade GI steel water tubing incl all fittings and accessories complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of GI Pipe etc.
Soft/loose soil
Hard/dense soil
Soft/disintegrated rock
Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for any type of soil complete all as specified and directed.
Removing the surplus spoil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level complete all as specified and directed.
S&F Gun metal gate valve with iron wheel head of 25mm dia complete all as specified and directed.
S & F Bib tap cast copper alloy of 15mm dia complete all as specified and directed.
M&L for carfully taking down the indoor & out door unit up to 2 TR cap including stabilizer and connected accessories and pumped on the refrigerant gas and keeping safe coustody for reuse complete all as specified and directed.
Refixing of item obtained from Ser Item No. 20.00 above inclding stablizers as indicated location including stand for outdoor unit, new copper tubing with insulation, drain pipe , copper electric cord cable from indoor to outdoor unit as required at site, topup of refrigrant gas to achieve desired cooling complete all as specified and directed.
M&L for core cutting in stone masonery wall of approx 60cm thick complete all as specified and directed.
M&L for Sheet metel enclosure with single pole and neutral with two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 volt complete all as specified and directed.
M & L for sub main wiring with two runs of single core 4.0 Sq mm Flame retardant PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 2.5 Sq mm single core Flame retardant PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in & including casing & caping complete all as specified and directed.
Supply, install testing commissioning of non cyclic, rotary, Desiccant type dehumidifer to reduce the humidity from 95% down to 40%, with digital humidistat and sensor, having react heater power 3.6 KW, process motor 0.1 KW, react motor power of 0.1 KW, 100mm dia hose pipe, including necessary core cutting for passing hose pipe complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of LT under ground cable 50 Sq mm 3.5 core, 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified and directed.
Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 10 cm after laying and stretching jointing and testing the cable complete all as specified and directed. [Note : Measurement will be done after punning]
Supplying and laying Brick, flat, size 230mm x 110mm x 75mm for cable protection complete all as specified and directed.
Supply and fix GI Pipe Light grade with all connected accessories of sizes 40 mm complete all as specified and directed.
Triple pole and earth encolsure with a three pin and earth plug with socket complete with one four pole MCB 63 Amps complete all as specified and directed.
Supply and fix sheet metal enclosure MCB DB double door SPN 4 way 230 V with neutral link and with 200 A bus bar complete all as specified and directed.
Supply and fixing SP 5 To 32 Amps rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete all as specified and directed with connection testing and commissioning.
Ditto all as per Ser Item No. 32.00 above but SPN 32 Amps complete all as specified and directed.
S & F Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type complete all as specified and directed.
S & F switch 15 amp flush type complete all as specified and directed.
M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32x6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified. Note:- (i) Venders are bound to get earthing result upto 5 Ohm for single earthings and 3 Ohm with the grid of two earthing.Any additional work and material required to achive the required result is included in the cost quoted by the tenderer.(ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with M&L for black cotton soil 1 cum.
Supply and Fix gun metal globe or gate valves with iron wheel head screwed both end for iron pipe and fixed complete all as specified and directed.
15 mm bore
20 mm bore
Supply & lay and jointing tubing medium grade galvanised iron pipes, ISI marked with all fittings such as bends, tees, elbows, nipple, unions, short pieces, sockets etc fixed to walls ceiling or laid on floor / roof etc all as specified of following sizes :-
15mm dia bore
20 mm dia bore
Supply and fix Rotational moulded water storage tank (cylinderical, vertical with closed top) hoisted and fixed in position with all connection such as in let,out let,air vent pipe overflow etc for capacity of 1000ltrs complete all as specified and directed.
Ball PVC valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
Bib taps,PVC with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
Supply , laying, jointing testing and commissioning LT UG armoured copper cable 6 Sq mm 4 core 1100 volts grade XLPE, electric power cable heavy duty with multi-stranded copper conductor laid in trenches,duct fixon wall with proper size saddles and clamps / in GI pipes complete all as specified and directed.
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board ) ISI Marked (IS:14772) for housing switches / sockets all a specified and directed
One light point controlled by one switch.
Supply and fix MCB SPN 40 Amp, 230 volt 'C' series complete all as specified and directed.
Supply and fix switch piano flush type 5 A one way complete all as specified and directed.
Supply and fix switch socket 5 Amps complete all as specified and directed.
Supply and fix ceiling rose surface type bakelite/PVC three terminal 65x50mm complete all as specified and directed.
S & F Wall mounted Fan 400 mm sweep complete all as specified and directed.
Supply & fix fans ceiling complete with electronic type regulator and accessories 230 V , 1400 mm sweep complete all as specified and directed.
M & L for sub main wiring with two runs of single core 1.5 Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 650 / 1100 V grade with colour code and one run of 1.5 Sq mm single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor including PVC conduit /cassing & caping complete all as specified and directed. ( Note :Two runs of 1.5 Sqmm copper cable,one run of earth wire of 1.5 Sqmm copper cable and one run of PVC conduit/casing capping of suitable size shall be measured & paid as one length.)
S & F Socket outlet 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed.
Supply and fix sheet metal enclosure MCB DB double door SPN 8 way 230 V with neutral link and with 200 A bus bar complete all as specified and directed.
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLSH PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board ) ISI Marked (IS:14772) for housing switches / sockets complete all as specified and directed.
One Fan point controlled by one switch .
S&F 450 mm sweep Heavy duty Metal Exhaust fan with louvers, 1400 RPM with complete wiring and other fixing acessories as per requirement on site complete all as specified and directed.
M&L for cutting wall for exhaust fan opening , the cutting mist be of suitable dimension to accommodate the exhaust fan and make good surface finish with cement plaster work complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /culverts or enclosed in GI pipe/ fix complete all as specified and directed for following size:- a) 10 Sq mm X 2.0 core
Supplying and laying un-reinforced precast concrete cable cover, class I, flat, size 250mm x 150mm x 40mm for cable protection complete all as specified and directed.
S&F GI tubing 50 mm bore medium grade galvanised with all GI fittings (such as bends, elbows, tees, conectors, short pieces, back nuts, unions, caps & plugs etc) fixed complete to wall and ceiling or laid in floor including cutting, threading complete all as specified and directed.(Note GI pipe to be laid in road crossings) Note: The cost of making good of road must be included in the quoted rate
& L for flame proof point wiring with 1.5 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100V grade conforming to IS 694 drawn through steel ERW conduit of 20 mm (external) flame proof, heavy grade ISI marked including necessary conduit accessories surface on wall, ceiling etc. including flexible metallic conduit FP grade and suitable size nipples for connect the FP junction box to light fitting & fan etc incliding 1.5 sq mm PVC insulated flame retardent copper conductor as in continous earth wire for one FLP light/ fan point controlled by one way metal clad switch of 5 amps capacity complete for one FLP light/ fan point controlled by one way metal clad switch of 15 amps capacity complete all as specified and directed.
One light point controlled by one switch complete all as specified and directed.
Supply and fixing LED light fitting 1X16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
S&F in replacement FLP - WP Rotary Switch with cable termination box in LM6 16 Amps (2 pole+ earth) 240 V ON / OFF complete all as specified and directed and certified by CMRI
Supply, laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /culverts or enclosed in GI pipe/ fix complete all as specified , for following size:- a) 35 Sq mm X 3.5 core
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor Flame retardant PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board ) ISI Marked (IS:14772) for housing switches / sockets complete all as specified and directed.
One 3 pin socket 5 A on independent board complete all as specified and directed.
One 3 pin socket 5 A on the same switch board complete all as specified and directed.
S & F Fan Regulator electronic step type 2 module , 230 V , 100 W complete all as specified & directed.
Supply & fix Heavy duty exhaust fan,metal body , AC single phase 230/ 240 V of size 300 mm sweep 1400 RPM with louver shutter having copper bound winding including 3 core copper electric cable connection from ceiling rose to fitting terminal complete all as specified and directed.
M&L for cutting stone masonary wall of thickness 450mm for exhaust fan opening, the cutting must be of suitable dimension to accommodate the the exhaust fan and make good surface finish with cement plaster work. Also making of wooden frame of required size and dimension to install exhaust fan as per site condition and complete all as specified and directed. Note:- The cost of wooden frame shall be included in the quoted rate
S & F Ceiling Fan 1200 mm sweep double bearing type, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) energy efficient ,white colour, 230 volts including blades, canopy and downrod including 3 core copper electric cable connection from ceiling rose to fitting terminal complete all as specified and directed.
Supply & fix LED tube light along with fixture, 1x20 W( 4 feet long) surface and wall mounted LED batten, extruded aluminium housing & integrated electronic drive including connecting up with three core 0.5 Sqmm flexible copper conductor cable ceiling rose to fitting terminal complete all as specified and directed.
S&F VTPN DB 4 way double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof 4 way IP 54 with the provision of space for one main incoming 4P MCCB and 12 SP MCB as outgoing complete all as specified and directed.
S&F MCCB 125 Amps, 25 kA, 4 pole, with fixed thermal and magnetic setting, conforms to IEC 60947-2 complete all as specified and directed.
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers etc connected to DBs all as shown in electrical plate No.5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation / earth work in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade,including GI earth wire 4 mm dia with GI protection pipe of 15 mm medium grade up to 7.5 meter length etc. complete all as specified and directed.
Material and labour for providing point wiring with two runs of 2.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 2.5 Sqmm single core copper stranded Flame retardant PVC insulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings / fixture etc and open recessed type Plastic Enclosure (Plastic Switch Board) ISI marked (IS 14782) for housing one 15 A Switch / sockets complete all as specified and directed.
Supply and fix switch piano flush type 15 Amp one way complete all as specified and directed.
Supply and fix Heavy Duty wall mounted air circulator fan 450 mm sweep copper wounded with complete wiring and other fixing accessories as per requirement at site complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /culverts or enclosed in GI pipe/ fix complete all as specified , for following size:- a) 95 Sq mm X 3.5 core
Supply, install testing commissioninfg of 5 Star rated inverter AC having 2.0TR Capacity, precision cooling technology, dual rotor invertor compressor , BLDC motor, filters, cold plasma technology, 100 % copper coils of inddor, outddor including installation kit for inddor & outdoor unit, extra length of refrigrent copper piping, coard cable, drain pipe as req at site. Refrigerant shall be echo friendly (R-410a, R-32)
M&L for carefully taking out existing split AC up to 2 TR with stabliser, MS stand complete with proper pump down and shifting and installation at directed loaction including replacment of copper piping with insulation, top up refrigrent gas as per existing type and reqd qty to achive desired temp, necessary core cutting to passing refrigrent pipes etc complete all as specified and directed.
Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified for following size:-
70 sqmm 3.5 core
Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.0 mm thick CRCA sheet double door(front & back opening), CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following:- (a) Aluminium bus bar 400 Amp (R Y B & N) with coloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set. (b) MCCB FP 200 Amps 25 KA 4pole - 01 No for main in coming (c) MCCB 100 Amps four pole 18 KA- 01 Nos (d) MCCB 63 Amps 3P, 18 KA - 03 Nos (e) LED indicator for RYB of size 22.5 mm - Set of 3 (f) 3 Phase Digital voltmeter -01 nos (g) 3 Phase Digital ammeter-01 Nos
M&L for cement concrete (1:3:6) type C2 in foundation filling and mass concrete using 40mm graded stone agg for pole/stay foundation or as required on site etc complete all as specified and directed.
M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete and coping of poles incl necessary form work using 20 mm graded stone aggregate etc or as required on site etc complete all as specified and directed.
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 25 X 4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade, including galvanised iron strip 25X4 mm with GI protection pipe of 40 mm medium grade up to 7.5 meter length, etc complete all as specified and directed.
M & L for Flame proof wiring with 2.5Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100v grade conforming to IS 694 drawn proof, through steel ERW conduit of 25mm (external) Frame proof, heavy grade ISI marked including necessary conduit accessories surface on wall, ceiling tec, including flexible metallic conduit FP Grade and suitable size nipples for connect the FP junction box to light fitting & fan etc including 2.5 sqmm PVC insulated FRLS copper conductor as in continuous earth wire for one FLP light / fan point controlled by one way metal clad switch of 5 Amps capacity complete for one FLP light / fan point controlled one way metal clad switch of 15 Amps capacity.
S & F in replacement FLP-WP Rotary Switch with cable termination box in LM6 16 Amps single pole 240 V ON / OFF certified by CMRI complete all as specified and directed.
S & F FLP weather proof enclosure for Led fluorescent tube light fitting dsuitable for 1 x 20W tube rod with all standard accessories, cable glands, reflectors, wire guard in aluminium alloy incl. Necessary fixing arrangements suitabe at site & CMRI ertified IP 65 protection complete all as specified and directed.
S & F FLP WP exhaust fan single phase, 230V, AC of 305 mm sweep (12"), 1440 RPM with louver incl necessary fixing arrangements suitable at site & model bearing No EF / 140 of Make SUDHIR SWITCH GEAR PVT LTD / OR Equivalent makes BALIGA / ALSTHOM / GEC and certified by CMRI complete all as specified and directed.
S&F flame proof junction box 3 way complete all as specified and directed.
Chaulya Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .