Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Rejected-Technical | Rejected-Technical As per Bid evaluation report |
Tender Value
Refer Docs
EMD Value
₹26.7 L
Closing Date
21 Sept 2023, 4:00 pmClosed
SE TEZU
SE APEC-VII Rockland Tezu
Various work under RDSS
2023_DOP_1388_1
RDSS/APEC-VII/LDV/2023-24/01
Open Tender
Electrical Works
730 days
Work
Please refer Tender documents.
8 documents required · 8 mandatory
₹17,700
EE RED
₹26.7 L
11 Jan 2024
6 Sept 2023
22 Sept 2023
6 Sept 2023
21 Sept 2023
6 Sept 2023
Amount
Supply
Manufacture and supply of 11 KV overhead line as per technical specification, approved drawings and scope of work
9 M long Steel Tubular 410 SP-32 conforming to IS2713(Part 1)1980
10M long Steel Tubular poles 410 SP-44 conforming to IS2713(Part 1)1980
Designing, Fabrication and supply of 7.50 M Long of 410 SP-09 steel tubular poles confirming to IS 2713 (Part 1 ) 1980
Manufacture and supply of Pre-fabricated galvanised steel items (zinc coating 610gms/sqm), like V cross arm, top clamp, DP cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp etc made of MS Channels, MS angle , MS flats of given sizes for over head structures as per technical specification, approved drawings and scope of work.
11 KV, 3 Wire, 2.8 m long cross arm made of MS Channel of size 100 x 50 x 6 mm .as per drawing No. REC/RDSS/11KV/04B complete as required etc
11 KV 'V' - Type cross arm made of MS Channel of size 75x40x6mm as per drawing No. REC/RDSS/11KV/07 including top bracket made as per drawing No. REC/RDSS/11KV/10 complete as required
Cross arm and bracing 2.44 m long of made out of MS channel of size 100x50x6mm and MS angle of size 65x65x6mm as per drawing No. REC/RDSS/11KV/21 complete with accessories nut / bolts etc as required.
MS Channel of size 100 X 50mm for Air Break switch top bracket transformer mounting and Drop Out fuse (8 X 2 = 16 m) i/c nuts and bolts.as per drawing No. REC/RDSS/11KV/05B complete as required
Manufacturing and supply of LT Aerial Bunched cable assesories
Suspension clamp assembly with eye hook and 2 nos MS Half Round clamp for suspending eye-hook with 3 nos nuts and bolts in complete set
Dead end clamp with eye hook and 2 nos MS Half Round clamps for suspending eye-hook with 3 nos nuts and bolts in complete set
Insulated connectors with covers
Manufacturing and supplying of GI earth clamps.
3Ph Distribution Box with associate accessories complete to connect household services as required.
Manufacture and supply of Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (2 Nos.), MS anchor plate (300mmx300mmx5mm), nut bolts, 2 Nos turn-buckles, 1.8 m long, 18 mm diameter solid MS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Manufacture and supply of Insulator and hardware as per technical specification, approved drawings and scope of work.
11 KV polymer Disc insulator 45 KN
11 KV polymer Disc insulator 45 KN hardware fittings
11 KV Polymer Pin Insulators with GI PIN
Manufacture and supply of Earthing arrangement as per technical specificatons, approved drawings and scope of work.
40 mm dia., 4.5m long GI pipe earth electrode with GI wire for pole earthing including salt charcoal and other accessories complete
8 SWG GI wire
11 KV 2.21 m long Guard Bracket made of Channel of size 75 x 40 x 5.7Kg/Mtr as per drawing No. REC/RDSS/11KV/25 Complete etc as required.
Copper plate earthing of transformer CBS & Battery charger including cost of copper plate size 600 X 600 X 6 mm & copper strip of size 25 X 4 mm i/c salt, charcoal etc. as required.
FOR 100KVA : Supplying, fitting and fixing of chain link fencing of SWG GL wire (50X50X5mm mesh) i/c corner and end post with MS angle of size 50X50X5mm and length not less than 1800mm intermideate post of MS angle of size 40X40X5mm and D length not less than 1800mm i/c supplying, fittings and fixing of hook, eyebolt with nuts, staples bolts etcas required with 3 horizontal line of GL wire 10swg at top middle and bottom and with one vertical line to each fencing tight and erect complete i/c the cost of primer, painting of MS angle iron post in PCC base etc and two cot of Al pain on foundation of cost with PCC works of 1:2:4 CC as per approved drawing.
FOR 100KVA : Fabrication and Supply of standard size MS Gate as per approved drawing
Manufacture and supply of ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work
6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel
6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit
Manufacturing and supply LT Aerial Bunched Cable 1100 Volts (3.5 Core) of size
AERIAL BUNCHED CABLE 3 X 50 SQ.MM+1x25 SQ. MM.+1x16 SQ. MM.
AERIAL BUNCHED CABLE 3 X 35 SQ.MM.+1x25 SQ. MM.+ 1x16 SQ. MM.
Manufacture and supply of Safety Alert System as per technical specification, approved drawings and scope of work
Danger Plate of size 250 mm x 200 mm of thickness 3 mm. ( 11000V)
Danger Plate of size 250 mm x 200 mm of thickness 3 mm. ( 415V)
Anti climbing devices with G. I. thornwire / Barbed wires.
Manufacture and supply of Painting and Finishing Work as per technical specification, approved drawings and scope of work
Supply & Painting with 2 coats of red oxide paint & 2 coats of paints on poles / equipment / metal surfaces on full rate basis.
Manufacture and supply of Augmentation of Distribution Transformer Substation using new outdoor type, oil immersed, naturally cooled pole mounted/ floor mounted (100KVA) distribution transformer (i/c transformer foundation materials) with all accessories as per scope of work, approved drawings and specifications:
11/0.433 KV Distribution Transformer 16 KVA 3 phase Aluminium wound DTR
11/0.433 KV Distribution Transformer 25 KVA 3 phase Aluminium wound DTR
11/0.433 KV Distribution Transformer 63 KVA 3 phase Aluminium wound DTR
11/0.433 KV Distribution Transformer 100 KVA 3 phase Aluminium wound DTR
Manufacture and supply of Designing Manufacturing & supply of weather proof pole mounted LT Pannel Board with adequate ratings of MCCBs/RCBs, space duly provided or mounting DT Energy & service connection distribution board within the same panel.
Manufacture and supply of 11 KV Distribution Class Lightening Arrester for DT as per technical specification, approved drawings and scope of work.
Manufacture and supply of 11 KV, 50 HZ Air Break Switch conforming to IS : 9920 (Pt - I to IV) with rated voltage 12 KV & rated normal current shall be 400 Amps. Provided with bimettallic connector on the incomming side to accommodate ACSR of sizes 20, 30, 50 Sqmm on the outgoing side.
Manufacture and supply of Outdoor, drop out expulsion type of 11 KV drop out fuse suitable for insullation in 50 HZ, 11 KV distribution system confroming to IS : 9385 (Pt - I to III) with rated voltage shall be 12 KV & rated current shall be 400Amps provided with a suitable arrangement these on 100 X 50 X 6 MM channel cross arm.
Manufacture and supply of 1.1 KV XLPE Aluminium Conductor, Stranded, armoured cable for connection of transformer LV bushing to Distribution Box and Distribution box to overhead line as per Scope of work, technical specification and approved drawings:
3.5C x 35 sqmm aluminium conductor cable
3.5C x 50 sqmm aluminium conductor cable
3.5C x 120 sqmm aluminium conductor cable
Mfg., Supplying & erection of Pole mounted Signboard at Distribution Transformer Structure clearly representing about the work, date of commissioning, estimated cost, scheme, employer's details and rating in KVA (Specification same as Danger Plate of size 250 mm x 200 mm of thickness 3 mm.)
Manufacturing, supplying and installation of alluminium PG clamp
Errection
Excavation of pole pit (of depth 1/6th of pole length) in all kind of soil/rock & Erection of following types of poles for 11 KV overhead line by providing and installing danger plate, anti-climbing devices (barbed wire), earthing material (coil and 8SWG GI wire), pole numbering including cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) or/and 200 mm average size bolders mixed with excavated earth , Top muffing etc as per scope of work, approved drawings and specifications:
9 M long Steel Tubular poles 410 SP-32
10 M long Steel Tubular poles 410 SP-44
STEEL TUBULAR POLES as per ISS.
Erection of 7.5 m long of 410 SP-09 Steel single pole including excavation of pits in all kind of soil/rock complete foundation (including supply of foundation materials) , Top muffing , fixing of cross arm , pole top bracket, anticlimbing device and other accessories complete in all respect as per TS.
Erection, testing & commissioning of pre-fabricated galvanised steel items like V cross arm, top clamp, DP cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of MS Channels, MS angle, MS flats of given sizes for over head structures and MS nuts, bolts & washers including painting by red oxide & aluminium paint as per technical specification, approved drawings and scope of work.
Angle bracing set 3.1 m long of size 65 x 65 x 6 mm complete with accessories nut / bolts etc.
Erection ,Testing and Commisioning of LT line with following LT Aerial Bunched Cable 1100 Volts (3.5 Core) of size:
AERIAL BUNCHED CABLE 3 X 50 SQ.MM+1x25 SQ. MM.+1x16 SQ. MM.
AERIAL BUNCHED CABLE 3 X 35 SQ.MM.+1x25 SQ. MM.+ 1x16 SQ. MM.
LT Aerial Bunched Cable assesories
Erection of GI earth clamps.
Erection of suspension clamp, Dead end assembly with eye hook , insulated connector and others miscellaneous items required for completion of works
Earthing arrangement as per technical specificatons, approved drawings and scope of work.
Excavation, erection, testing & commissioning of 40 mm dia., 4.5 m long GI pipe earth electrode with GI wire for pole earthing , Charcoal, Salt and other accessories complete
Erection of 8 SWG GI wire for earthing and guarding by providing GI nut, bolts & washers, turn buckle etc
Erection of 11 KV, 3.1 m long Guard Bracket made of Channel of size 100 x 50 x 6 mm Complete etc
Copper plate earthing of transformer CBS & Battery charger including cost of copper plate size 600 X 600 X 6 mm & copper strip of size 25 X 4 mm i/c salt, charcoal etc. as required.
FOR 100KVA : Fabrication and Supply of standard size MS Gate as per approved drawing
Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (2 Nos.) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per technical specifications, approved drawings and scope of works.
Laying out, tensioning, binding of conductor and tightening of stays and stringing, testing and commissioning of ACSR Conductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting PG Clamps etc as required as per approved drawings, scope of work and technical specifications
6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel
6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Weasel
Painting and Finishing Work
Painting with 2 coats of red oxide paint & 2 coats of alluminium paints on poles / equipment / metal surfaces on full rate basis.
Jungle clearance thick and thin including cutting, uprooting and removing trees more than 20cm upto 61 cm girth, filling up and levelling the hollows of dugs roots, stacking the useful materials and disposing of rubbish upto a distance 15m outside the periphery of the area cleared (Girth to be measured 1.22m above ground level and at ground level in case of bamboo or cane clumps).
Girth above 300 mm to 600 mm.
Girth above 600 mm to 1000 mm.
Girth above 1000 mm.
Cutting down of smaller trees of girth 300 mm and below including all types of vegetation, grass bushes, shrubs, saplings and remains of them for ease access for laying and stringing of conductors as well as to make foot path at tower locations or any construction site as may be required.
Erection, Testing and Commissioning of pole mounted/floor mounted (100KVA) Distribution Transformer (i/c transfomer foundation materials) with all accessories as per scope of work, approved drawings and specifications:
11/0.4 KV Distribution Transformer 16 KVA 3 phase Aluminium wound DTR
11/0.4 KV Distribution Transformer 25 KVA 3 phase Aluminium wound DTR
11/0.4 KV Distribution Transformer 63 KVA 3 phase Aluminium wound DTR
11/0.4 KV Distribution Transformer 100 KVA 3 phase Aluminium wound DTR
SAFETY ALERT SYSTEM
Erection of danger plate made of mild steel sheet of atleast 1.6 mm thick and vitreous enameled white, with letters, figures and the conventional skull and cross-bones in signal red colour on the front side for -
Danger Plate of size 250 mm x 200 mm of thickness 3 mm.(415V)
AGARWAL TRADERS
M/s D & G Construction
P N Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid