Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC FLAT NO 2 AMEYA APARTMENT SHIV COLONY NEAR PANDAV NAGARI INDIRA NAGAR NASHIK 422009 | NASHIK | NASHIK | MAHARASHTRA | 422009 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹12.9 L+₹3.1 L (31.8%)Rejected-Finance 02 SIDDHANT RESIDENCY NEAR AMBAD POLICE STATION SINHASTHA NAGAR CIDCO NASHIK MAHARASHTRA 422009 UDYAM MH 23 0069304 | NASHIK | MAHARASHTRA | 422009 | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹13.0 L+₹3.2 L (32.3%)Rejected-Finance | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹13.1 L+₹3.3 L (34.1%)Rejected-Finance | L4 | Rejected-Finance BEING NOT L1 | |
| 5 | L5₹13.6 L+₹3.8 L (38.8%)Rejected-Finance | L5 | Rejected-Finance BEING NOT L1 |
Tender Value
₹10.0 L
EMD Value
₹19,400
Closing Date
29 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF OJHAR
GE AF OJHAR
REPAIR/ MAINTENANCE TO SUMMER APPLIANCES AT AF STATION OJHAR
2021_MES_474364_1
8798/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹19,400
Yes
13 Oct 2021
10 Sept 2021
1 Oct 2021
11 Sept 2021
29 Sept 2021
23 Sept 2021
60 days
Amount
Material & Labour for servicing of Solar water heater of any type/make/model of capacity as mentioned below loacated at 30 meter height from ground at various places i)100 ltr x11 units ii)250 ltr x 1 unit iii)300 ltr x 2 unit iv)500 ltr x 2 unit v)1000 ltr x 3 unit vi)2000 ltr x 4 unit ,carring out descaling of shell & copper tubes of collecter plates,make up tank cleaning,replacement of float valves,using necessary teflon tapes CPVC solution,Nut ,bolts,GI fittings of requisite site,rubber gasket for panel as per site requirement for smooth functioning of solar water heater & acheiving rated output temperature of water,complete all as specified and directed by Engineer-In-Charge.
Supply & Laying repair LDPE CPVC pipes 6 kgf/cm2 & Plain CPVC fitting in trenches/wall surface for water of 3/4" outer dia ,complete all as specified & directed by Engineer-In-Charge.
General servicing Split AC capacity 1.5/2T ,dismantling unserviceable part of unit including cleaning of air filter,display,PCB,de-dusting of complete(indoor/outdoor) unit ,checking electrical connections & rewiring ,greasing of movable parts for getting trouble free service & making Split AC serviceable complete all as specified and directed by Engineer-In-Charge. (Note: Repair/Replacement of the component required shall be paid under relevant item of scedule here-in-after)
Supply only new sealed unit compressor in exchange of existing unserviceable sealed compressor of 1.5 T split air conditioner Make: Kirloskar complete all as specified & as directed by Engineer-In -Charge.(Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply only new sealed unit compressor in exchange of existing unserviceable sealed compressor of 2.0 T for split air cinditioner Make:Kirloskar complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply only new fan motor 1/3 Hp ,230 v for split AC Make AUE or equivalent including taking down old unserviceable fan motor from existing position complete all as specified and as directed by Engineer -in Charge.
Repairs to split AC of 1.5/2 T capacities after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressure, leak testing of the system, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired cooling for the following complete all as specified & as directed by Engineer-In -Charge. (Note- Refrigerant will be issued by MES as per requirement )
Supply only running capacitor for split Air conditioner 1.5 T/2 T of capacity 36/45 mfd , 7 point ,440 VAC Make Epcos ,complete all as specified and as directed by Engineer -in -Charge
Supply only starting capacitor for split Air conditioner 1.5 T/2 T of capacity 80/100 mfd 440 VAC Make Epcos, complete all as specified and as directed by Engineer -in -Charge
Supply only Relay (8500-4) (Make Annapurna) suitable for Air Conditioner mentioned above, complete all as specified & as directed by Engineer-In -Charge.
Supply only remote control switches 1.5 Ton to 3 Ton capacity split A/C of any make as existing sample complete all as specified & as directed by Engineer-In -Charge.
Supply only blower motor single phase AC 200/230 volts suitable for split model A/C of capacity 1.5 TR, complete all as specified & as directed by Engineer-In -Charge.
All as per item no 23 here-in before but for 2 TR complete all as specified & as directed by Engineer-In -Charge.
Supply only Bush with Blower shaft assy complete,1.5 Ton to 3 Ton capacity split A/C of make as existing sample ,complete all as specified & as directed by Engineer-In -Charge.
Supply only Printed Circuit Board (PCB) For split A/C of make as existing sample ,complete all as specified & as directed by Engineer-In -Charge.
Repairs to Circuit of existing Printed Circuit Board (PCB) in split type AC of any make, complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in repair condensor coil of copper suitable for 1.5 TR/2 TR split type air conditioner including taking down old unserviceable condensor coil from existing position complete all as directed and specified by Engineer-In Charge
Supply and fix in repair condensor coil of Aluminium suitable for 1.5 TR/2 TR split type air conditioner including taking down old unserviceable condensor coil from existing position complete all as specified & as directed by Engineer-In Charge.
Supply and fix contactor switch suitable for multi (3 TR Unit) split type unit complete all as specified & as directed by Engineer-in Charge.(Make. Blue star,Schnieder)
S&F sheet metal enclosure single pole and neutral 2 Pin and earth metal plug and socket, 240 volts, (Make - Standard/ Havells/MDS), 32 Amps capacity after taking out old unserviceable DB from existing position complete all as specified & as directed by Engineer-In -Charge.
S&F 240 volts 32 amps capacity MCB single pole after taking out old unserviceable MCB from existing position Make - Standard/Havells/MDS complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in repair copper tubes 2 mm thick for additional length required in the process of maitenance of the split air conditioners unit, with insulation of puff or TF quality of thermocole or poly urithine insulating tubes all as specified for 5/8 inch copper tubing complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in repair copper tubes 2 mm thick for additional length required in the process of maitenance of the split air conditioners unit, with insulation of puff or TF quality of thermocole or poly urithine insulating tubes all as specified for 1/4 inch copper tubing complete all as specified & as directed by Engineer-In -Charge.
Repair to refrigerator of capacity 165/210/310 litres ,General servicing,dismantling unserviceable part of refrigerator, checking electrical connections & rewiring,cleaning of refrigerator unit ,and making refrigerator serviceable complete all as specified & as directed by Engineer-In -Charge. (Note: Repair/Replacement of the component required shall be paid under relevant item of scedule here-in-after)
Supply only new sealed unit compressor in exchange of existing unserviceable sealed compressor unit (type 1/8 ) Make-L51Q,66Q,Kirloskar,Suitable for 210 litre refrigerator of Godrej,Whirlpool, Videocon & LG complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply only new sealed unit compressor in exchange of existing unserviceable sealed compressor unit (type 1/6 ) Make-L51Q,66Q,Kirloskar,Suitable for 310 litre refrigerator of Make Godrej,Whirlpool, Videocon & LG complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Repairs to refrigerator after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressure, leak testing of the system, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired cooling complete all as specified & as directed by Engineer-In -Charge.(Note- Refrigerant will be issued by MES as per requirement )
Supply only over load protector of various capacities for the cooling appliances, complete all as specified & as directed by Engineer-In -Charge.
Supply only thermostats with control knob of various capacities for the cooling appliances , complete all as specified & as directed by Engineer-In -Charge.
Supply only copper strainer and capillary tube suitable for refrigerator mentioned above Godrej,Whirlpool, Make : KISHCO / MB CAPIALLARYGodrej,Whirlpool, in replacement of unserviceable strainer & capillary complete all as specified & as directed by Engineer-In -Charge.
Supply only relay suitable for 1/8 and 1/6 compressor of capacities for the cooling appliances,complete all as specified and directed by Engineer in Charge
Supply only vegitable tray in moulded PVC or plastic suitable for 300 lit refrigerator ,complete all as specified & as directed by Engineer-In -Charge.
Repair to Deep freezer of capacity 265/ 320 /500 ltrs ,general servicing ,dismantling unserviceable part,checking electrical connections & rewiring,cleaning of deep freezer unit ,reassembling & making deep freezer serviceable complete all as specified & as directed by Engineer-In -Charge. (Note: Repair/Replacement of the component required shall be paid under relevant item of scedule here-in-after)
Supply only new sealed unit compressor in exchange of existing unserviceable sealed compressor unit Kirloskar or 91Q,110 of Godrej (with Relay unit) for deep freezer of capacity 265 ,320 litre complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
-ditto- but for deep freezer of capacity 500 litre complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply only fan motor 1/35 HP suitable for deep freezer of capacity 265/300/320 litre , fan motor AC single phase 230 volts and connecting up complete all as specified & as directed by Engineer-In -Charge.
Supply only capillary tube and silica drier type strainer suitable for Deep Freezer 265/320/500 litre capacity (Make - Blue Star & Voltas) ,complete all as specified & as directed by Engineer-In -Charge.
Supply only thermostats with control knob of various capacities for the cooling appliances for deep freezer upto 500 litre capacity, complete all as specified and as directed by Engineer -In-Charge.
Supply only relay suitable for 1/8 and 1/6 compressor of capacities for Deep freezer upto 500 litre, complete all as specified and as directed by Engineer in Charge
Repairs to Deep freezer after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressere, leak testing of the system, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired cooling complete all as specified & as directed by Engineer-In -Charge.(Note- Refrigerant will be issued to by MES as per requirement )
Repair to storage type water cooler of capacity 40/80 & 60/120 ltrs , general servicing ,dismantling unserviceable part, checking electrical connections,cleaning internally and externally ,cleaning of water tank,tray & water outlet scraping with emery paper filling putty wherever required and painting with one coat of red oxide and two coats of synthetic enamel paint of approved colour and reassembling marking of MES/SM No in 25 mm size alphabetes,reassembling, refitting & making water cooler serviceable, complete all as specified & as directed by Engineer-In -Charge. (Note: Repair/Replacement of the component required shall be paid under relevant item of scedule here-in-after)
Supply only new sealed unit compressor in exchange of existing unserviceable sealed unit compressor Make : godrej 91Q,Kirloskar 4440 M,Kirloskar 446, Kirloskar 443 suitable for water cooler suitable for water cooler of capacity 40/80 litre complete all as specified & as directed by Engineer-In -Charge.
Supply only new sealed unit compressor in exchange of existing unserviceable sealed unit compressor Make : godrej 91Q,Kirloskar 4440 M,Kirloskar 446, Kirloskar 443 suitable for water cooler of capacity 60/120 litre complete all as specified & as directed by Engineer-In -Charge.
Supply only fan motor 1/64 HP suitable for water cooler of capacity 40/ 80 lit AC single phase 230 volts and connecting up complete all as specified & as directed by Engineer-In -Charge.
Supply only fan motor 1/32 HP suitable for water cooler of capacity 60 / 120 lit , AC single phase 230 volts and connecting up complete all as specified & as directed by Engineer-In -Charge.
Supply only thermostats with control knob of various capacities for water cooler AC single phase 230 V of make INDFOSS or Equivalent make, complete all as specified and as directed by Engineer In Charge.
Supply only over load protector of various capacities for for water cooler of capacities 60/120 litre,AC single phase 230 Volt, complete all as specified & as directed by Engineer-In -Charge.
Supply and fix capacitor 2.5 to 10 mfd Make -Epcos or Equivalent , complete all as specified & as directed by Engineer -in -Charge
Supply only Starting capacitor for water cooler of capacity 60 mfd Make : Epcos or equivalent , complete all as specified and as directed by Engineer -in -Charge
Supply and fix in repairs push type spring loaded taps chromium plated brass suitable for 15 mm dia bore of pipe for water cooler complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in repairs float valve assembly complete with PVC ball valve suitable for 15 mm bore of pipe for water cooler. Make: Prayag, Water tech complete all as specified & as directed by Engineer-In -Charge.
S & F in repairs, Brass Chromium plated stop cock both end screwed suitble for 15 mm dia GI Pipe complete all as specified & as directed by Engineer-In -Charge.
S&F in repair Set of Copper pencil strainer suitable for Water Cooler mentioned above including taking down old unserviceable copper pencil strainer, complete all as specified and as directed by Engineer-In-Charge. (Make - KISHCO/ MB CAPPALLARY)
S&F in repair aluminium fan blade for blower motor for water cooler (make : Usha/Shreeram Usha, voltas Tushar & Voltas) of Capacity 60/120 ltrs/Hrs, 80/120 ltrs/Hr and 150 ltrs including taking down old unserviceable fan blade complete all as specified & as directed by Engineer-In -Charge.
Supply & fix flexible cold water nylon reinforced PVC c pipe for drain outlet, complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in repair plug top 15 Amp Make Anchor complete all as specified & as directed by Engineer-In -Charge.
Repair to water cooler stainless steel water tank including soldering existing copper pipe where ever necessary complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in repair flexible cord PVC insulated and sheathed 4 core flexible with copper conductor of size 2.5 sq mm complete all as specified & as directed by Engineer-In -Charge.
Repairs to water cooler after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressure, leak testing of the system, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired cooling complete all as specified & as directed by Engineer-In -Charge. (Note- Refrigerant will be issued by MES as per requirement )
Supply & fix Rubber gasket for water cooler top cover as per sample complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in repair blower fan blades of sweep 480mm,alongwith 230 Volts, 1380 RPM double speed motor with confirming to relevant IS suitable for desert cooler of make Kenstar complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in the process of maintenance / repair vertical pump complete with flexible pipe connections suitable for desert cooler of any capacity/ CFM and make, complete all as specified & as directed by Engineer-In -Charge.
General servicing of the desert coolersincluding dismantling of various internal and external parts cleanig ,scraping the rust and old paint wherever necessary painting with red-oxide metal primer from inside and one coat of synthetic enamell paint of approved color from outside ,carrying out maintenance / repairs, separating panels, pump, wood wool pads, float valve etc, cleaning the tank, tray, clearing of spray nozzles / holes, supply and fix new set of wood wool or Khus pads/grass pads reassembling the desert cooler and connecting up the controls and making desert cooler serviceable complete all as specified & as directed by Engineer-In -Charge.
Supply and fix 15 mm dia drain pipe for split AC , complete all as specified & as directed by Engineer -in -Charge
Taking down existing split AC of any capacity indoor & outdoor unit with supporting accessories/brackets & relocating the same Split AC (making indoor unit and outdoor unit connections) duly mounted on brackets, connecting refrigerant piping , connecting up power supply,recommissioning & testing for smooth running, complete all as specified & directed by Engineer-In-Charge.
SHRI SULAI ELECTRICALS
DIAMOND ENTERPRISES
K R Electricals
BHAVIN INFRA
Paras Electricals
Shree Sai Samarth Enterprises
YASHRAJ ELECTRICALS
OM SAI ASSOCIATES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .