Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | L1 | Accepted-AOC L1 | |
| 2 | L2₹37.7 L+₹30,942.30 (0.83%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹38.9 L+₹1.5 L (3.89%)Rejected-Finance A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | L3 | Rejected-Finance L3 |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
20 Feb 2021, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
SPL REPAIRS OF BLDG NO T-23-24/A (HERITAGE BLDG) AND PROVN OF HARD STANDING WITH OPEN COVERED SHED FOR PARKING OF VEHS AND BROADING OF CULVERT NEAR BLDG NO P-12 INCLUDING CERTAIN MINOR WORKS AT DINJAN MIL STN
2021_MES_415608_1
C/8250/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE DINJAN
₹68,000
Yes
25 Feb 2021
23 Jan 2021
22 Feb 2021
23 Jan 2021
20 Feb 2021
7 Feb 2021
Amount
Surface dressing not exceeding 15 cm deep and getting out in soft/loose soil complete all as specified and as directed.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and and getting out including in soft/loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading in layers not exceeding 25cm levelling, watering and well ramming in soft/loose soil complete all as specified and as directed.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, filling, sub base of floors and mass concrete, etc complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
M&L for brick work with sub class 'B' brick stright or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B-0, (using 12.5 mm graded stone aggregate) as in benching, coping, etc. incuding necessary form works etc complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) mixed with integral water proofing compound weight of cement as per manufacturer's instructions and finished surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid separately.
"Supply only" liquid water proofing compound complete all as specified and as directed. Make : Dr FIXIT/Fosroc/choksey.
M&L for rendering 10mm thick on fair faces of brick work or concrete surface in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick on other than fair faces of brick work or concrete surface in cement mortar (1:4) finished complete all as specified and as directed.
M&L for three coats of white wash on newly plastered ceiling surfaces including preparation of surfaces complete all as specified and as directed.
M&L for preparation new external surfaces of wall, chajja, facia etc and applying two coats of water based acrylic weather proof exterior emulsion (exterior wall finish) paint over a coat of primer as per manufacturer's instruction complete all as specified and as directed.
M&L for roof plates with sleeve pieces riveted or welded thereto, and similar roof and ceiling connections complete all as specified and as directed.
M&L for mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as speicfied and as directed.
M&L for rolled mild steel as in roof trusses (framed), trussed, purlins, crane gantries, guarders for chain pulley etc, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pices, cleat, nuts bolts etc quality confirming to Fe-290(Gde E-165) complete all as specified and as directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L for pre-painted galvalume aluminum zinc coating galvanised iron based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and as directed.
M&L for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and as directed.
M&L for cement concrete (1:2:4) type B-1 (using 20mm graeded stone aggregate) as in foundation, including rafts, footings foundation beams, plinth beams, bases of columns etc, basement slab, under reamed piles and mass concrete complete all as specified and as directed.
M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified and as directed.
M&L for hardcore of broken bricks of gauge n.exc 63 mm deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 150mm thick, cement concrete (1:2:4) type B-2 (using 40mm graded stone aggregate) as in sub-bases, sub-floors, floors and pavings etc. and finished the cement concrete surfaces even and fair without using extra cement complete all as specified and as directed.
M&L for forming 12mm thick expansion joint filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade 'B' for 100mm thick slab complete all as specified and as directed.
M&L for forming Construction joints 30mm deep x 10mm wide, filled with sealing compound Grade 'A' complete all as specified and as directed.
M&L for TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L for precast cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) in landing, cover slabs for drain and similar articles and set in cement mortar (1:6) complete all as specified and as directed.
M&L for 75mm thick plain cement concrete (1:3:6) type C-2, (using 40mm graded stone aggregate) as in sub base of flooring/hard standing etc complete all as specified and as directed.
M&L for chequered cement concrete tiles 25cmx25cmx20mm thick set and jointed and pointed with grey cement and pig ments in neat cement slurry in floors including 15mm thick secreed bed or bedding in cement mortarin (1:4) set and jointed and pointed in neat cement slurry complete all as specified and as directed.
Dismantling of boarding, any description, fixed in any position with nails complete all as specified and as directed.
Dismantling timber scantlings 40Sqcm and over in section, in any position complete all as specified and as directed.
Dismantling of timber fillets, rails, posts, rafters, purlins etc under 40 sqcm in section complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets complete all as specified and as directed.
M&L for second class hardwood, scantlings, clean sawn, in unframed work complete all as specified and as directed.
M&L for 25mm thick second class hard wood boarding fixed with nails in any situation (except flooring and skirting), planed one side with butt joints complete all as specified and as directed.
M&L for second class hard wood plain fillets, bull nosed, splayed, chamfered or rounded on one edge wrought, fixed with screws, cross sectional area exceeding 3 and not exceeding 6 Sqcm complete all as specified and as directed.
M&L for second class hard wood plain fillets, bull nosed, splayed, chamfered or rounded on one edge wrought, fixed with screws, cross sectional area exceeding 13 and not exceeding 25Sqcm complete all as specified and as directed.
M&L for french polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats complete all as specified and as directed.
Taking down of wall panelling any thickness including cover fillets complete all as specified and as directed.
S&F for pre-laminated MDF board 5.5mm thick DWR Grade -1 with one side laminates wooden texture as approved fixed to wall all as specified and as directed. Make : Century/Kit ply/Anchor.
S&F for GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to cerntre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete including Hangers 6 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia, 40 mm long complete all as specified and as directed.
S&F for 8 mm thick, Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face to centre, board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish complete all as specified and as directed. Note : Frame work for ceiling shall be measured and paid separately.
M&L for preparing newly surfaces of ceiling, etc and applying two coats of royale luxury emulsion paint over a coat of primer 3mm thick wall care putty to a smooth surface complete all as specified and directed.
S&F 6 mm thick, non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/Aluminium framework with screws complete all as specified and as directed.
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4.0 Sqm in each with shutter (without taking off shutter from frame) complete all as specified and as directed.
M&L for well seasoned second class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
M&L for 35 mm thick, glazed, skeleton shutters with second class hard wood,open rebated and prepared to receive glass, gauze, etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part-I, Section -8, clause 8.24 (a) complete all as specified and as directed.
S&F for 100 mm size butt hinges medium weight, cold rolled mild steel complete all as specified and as directed.
S&F for 150 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed.
S&F for 150 mm size aluminium handles cast type anodised complete all as specified and as directed.
S&F for mild steel sliding door bolts 300 mm long, plate type stove enemelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four in bolt plate and two on staple plate complete all as specified and as directed.
S&F for mild steel work as in band, strap, hold fast, cleat, support, hook, hinges, base tie for door frame etc and other similar items conforming to Fe-290 (Gde E-165) complete all as specified and as directed.
M&L for plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etc including necessary form work complete all as specified and as directed.
M&L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Demolition of plain cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness. (below or above ground level) complete all as specified and as directed.
M&L for 40 mm thick, Cement concrete 1:2:4, type B-2 (using 40mm graded stone aggregate) as in base of flooring/hard standing, etc, and finished the cement concrete surfaces even and fair without using extra cement complete all as specified and as directed.
M&L for heritage laminated wooden flooring on PCC floor etc. comprising with the following operation and as specified herein below and as directed :- (a) Taking down existing old wooden flooring with polyfilm membrane compound including cleaning & removing debris to a distance exc 100m & n.exc.250m. (b) Treating the surface with termit chemical by drilling 6mm holes at a downward angle of about 45 degree at the junction of woodwork & masonry and squirting chemical emulsion into these holes till refusal and the treated holes shall be sealed. (c) Preparing & cleaning of fully dried surface of floor and repairing the surface by cement mortar 1:3 and making the surface leakage proof & seepage proof and levelled by grinding or applying putty to receive wooden foor perfectly . (d) Laying a layer of 1 mm (minimum) thick waterproofing Polypropylene membrane shall be accumulated in room temperature upto 48 to 72 hrs. (e) Fixing laminated wooden floor tiles made out of size 1214x193x12(mm) of grade AC-4 with tannon and grooves joints. (f) Providing best quality wooden floor cornice size 100x20 mm to conceal the joints between the floor and the wall to make it look neat and beautiful. Note : Sample of laminated wooden floor tiles & cornice shall be submitted by the contractor before procurement.
S&F in repairs, curtain rod, fency type best quality, coated with aluminium alloy matching shade with bracket, chromium plated with fixing wooden brackets, stops, rollers, etc. complete all as specified and as directed.
M&L for 40mm thick 1st class hard wood (teak wood) carved sliding door with double shutter including frame (capable for sliding door) of size 150x150mm, half portion of door 3D carveing made of solid wood, antic design, french polished and half portion 9mm thick skretch toughened glass imbedded for interior location fitted complete all as specified and as directed. Note :- (i) Design and drawing of door shall be approved by GE before procurement by the contractor . (ii) Sample of hard wood and test certificate shall be submitted by the contractor before procurement. (iii) Rate also included for all accessaries i.e. heavy duty sliding Barn, Door Hardware Kit Single rail, 200mm long brass handle, Sliding door lock etc. (iv) 9mm thick skretch toughened glass shall be measured and paid separately.
S&F for 9mm thick toughened skretch glass with revit, clamp, socket, nut, bolt and all necessary fitments for vertical and horizontal both bay of fixing complete all as specified and as directed.
Taking down aluminium/copper point wiring (light, fan, socket or power) including unserviceable light fittings, switch board complete, switch sockets, ceiling roses, pendants, regulators, sockets, etc and removing materials from site and making good disturbed surfaces of walls, floors using cement mortar etc and finished to match with existing complete all as specified and as directed.
Point wiring (concealed) with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core unsheathed, copper conductor cables drawn through and including PVC conduit 'medium grade' of suitable size with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLSH PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including 1mm thick steel sheet terminal box concealed in wall and hylam sheet cover for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one, one way switches complete all as specified and as directed.
All as per item No 67 above but one 3 pin Switch socket combination, 5 Amps on Independent board complete all as specified and as directed.
All as per item No. 67 above but one 5 Amps, 3/5 pin socket outlet on the same board with other switches.
All as per item No 67 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 6/16 Amps switch socket combination on Independent board.
S&F for modular switch 6 Amps 240 V,single pole, one way, flush type and connecting up complete all as specified and as directed. Make : Cat No. 573400 of Legrand/Havells/HPL.
S&F for modular socket multi purpose ( ISI marked), 2 pin and 3 pin 5 Amps , 240 V , flush type, controlled by one switch and connecting up complete all as specified and as directed. Make : Legrand/Havells/HPL.
S&F for modular switch socket combination multipurpose (ISI marked), 2 pin and 3 pin 5/6 Amps, 240 V, flush type, controlled by one switch and connecting up complete all as specified and as directed. Make : Cat No. 573542 of Legrand/Havells/HPL.
S&F for modular switch socket combination multipurpose (ISI marked), 2 pin and 3 pin 6/16 Amps, 240 V, flush type, controlled by one switch and connecting up complete all as specified and as directed. Make : Cat No. 573542 of Legrand/Havells/HPL.
S&F for stepped type electronic fan regulator modular type with two module complete all as specified and directed. Make : Cat No. 14502 of Anchor/Haveells/HPL.
S&F for ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and as directed.
S&F for modular type white cover plate with frame two module complete all as specified and as directed. Make : Cat No. WH 575710 of Legrand/Havells/HPL.
S&F for modular type white cover plate with frame three module complete all as specified and as directed. Make : Cat No. WH 575720 of Legrand/Havells/HPL.
S&F for modular type white cover plate with frame four module complete all as specified and as directed. Make : Cat No. WH 575730 of Legrand/Havells/HPL.
S&F for modular type white cover plate with frame six module complete all as specified and as directed. Make : Cat No. WH 575740 of Legrand/Havells/HPL.
S&F for modular type metal flush box suitable for two module complete all as specified and as directed. Make : Cat No. 689007 of Legrand/Havells/HPL.
S&F for modular type metal flush box suitable for three module complete all as specified and as directed. Make : Cat No. 689008 of Legrand/Havells/HPL.
S&F for modular type metal flush box suitable for four module complete all as specified and as directed. Make : Cat No. 689009 of Legrand/Havells/HPL.
S&F for modular type metal flush box suitable for six module complete all as specified and as directed. Make : Cat No. 689042 of Legrand/Havells/HPL.
S&F for 18 W surface and wall mounted LED Batten with polycarbonate housing and intigrated complete all as specified and as directed. Make :Havells/Philips/Bajaj/CG/Crompton.
S&F in replacement of 9 W surface and wall mounted LED Batten with polycarbonate housing and intigrated complete all as specified and as directed. Make : Havells/Philips/Bajaj/CG/Crompton.
S&F for lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed.
S&F for LED lamp 9 Watt complete all as specified and as directed. Make : Havells/Philips/Bajaj.
S&F in repair 15 Watt recess mounted pressure die-cast LED downlighter with 36 degree beam angle and aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation with separate replaceable electronic driver included cutting-opening of ceiling any type & fixing arrangement for light fitting complete all as specified and as directed. Make : Cat No. LETS36R015XC of Jaquar/Philips/Bajaj.
S&F for distribution board 8 way multiphase outgoing suitable to mount MCB TPN as incoming double door duly door earthed, IP 54 protection, isolated Neutral link, with MCB SP 6-32 A as out going complete all as specified and as directed (MCB TPN and MCB SPs shall be measured and paid separately under relavent items)
S&F for vertical distribution board multiphase outgoing suitable to mount MCCB 125 A 4P as incoming 4way double door duly door earthed, IP 54 protection, isolated neutral link, with MCB TP 6-32 A as out going complete all as specified and as directed (MCB TP and MCCB shall be measured and paid separately under relavent items)
S&F for factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 8 way, 240 Volts, 200 AMPS suitable for housing MCBs complete all as specified and as directed. Make : Cat No. DBDD08 of HPL/L&T/Havells.
S&F for MCB, duoble pole, 240 Volts, 6 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make : HPL/L&T/Havells.
S&F for MCB, 'C' Series, SP, 240 Volts, 5 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and directed. Make : HPL/L&T/Havells.
S&F factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, TPN, 4 way, 415 Volts IP-43, IK-09, suitable for fixing MCBs complete all as specified and as directed. Make : Cat No. DBTDD04 of HPL/L&T/Havells.
S&F for MCCB, 4 pole, 415 volts of capacity 125 amps 25 KA complete all as specified and as directed.
S&F for MCB, TPN, 415 Volts, 63 Amps, "C" series, 10 KA breaking capacity complete all as specified and as directed. Make : HPL/L&T/Havells.
S&F for MCB, TPN, 415 Volts, 6-32 Amps, "C" series, 10 KA breaking capacity complete all as specified and as directed. Make : HPL/L&T/Havells.
S&F for MCB, TP, 240 Volts, 6-32 Amps, "C" series, 10 KA breaking capacity complete all as specified and as directed. Make : HPL/L&T/Havells.
S&F for MCB, SP, 240 Volts, 6-32 Amps, "C" series, 10 KA breaking capacity complete all as specified and as directed. Make : HPL/L&T/Havells.
Taking down unserviceable sub-main wiring with rigid steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and as as directed.
M&L for sub main wiring with three run of 10.0 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (HRFR), 1100 Volts grade drawn through PVC casing-caping of suitable size, fixed to wall/ceiling etc including one run of 10.0 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (HRFR) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) one run PVC Casing-caping, two run wiring cables and one run of earth wire will be measured as one length. (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
M&L for sub main wiring with two run of 6.0 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (HRFR), 1100 Volts grade drawn through PVC casing-caping of suitable size, fixed to wall/ceiling etc including one run of 6.0 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (HRFR) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) one run PVC Casing-caping, two run wiring cables and one run of earth wire will be measured as one length. (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
M&L for Sub main wiring with four run of 4.0 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (HRFR), 1100 Volts grade drawn through PVC casing-caping of suitable size, fixed to wall/ceiling etc including one run of 4.0 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (HRFR) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) one run PVC Casing-caping, four run wiring cables and one run of earth wire will be measured as one length. (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
S&F in repairs sheet metal enclosure, single pole and neutral with two pin and earth plug complete with one single pole MCB, 32 Amps, 240 volts complete all as specified and as directed. Make : Havell's/L&T/Siemens/HPL/Standard/Legrand.
S&F for decorative light fitting wall mounting champagne gold finish fixture made up of Polycarbonate suitable for 15 W including suitable LED Bulb complete with all accessories internally pre-wired and including connecting up with twin core twisted flexiblecopper conductor cable with suitable size complete all as specified and as directed. Make : Cat part No: LHFOECE1TZ10014 of Havells/Bajaj/HPL.
M&L for sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and as as directed. Note : Thickness after punning down shall be measured for payment.
Supply and laying well burnt bricks, sub class 'B' bricks laid breath wise along length of cable in trenches for cable protection laid for UG cable protection complete all as specified and as directed.
M&L for galvanised iron tube light grade 50 mm bore laid in trenches/road/drain/wall alongwith all fittings complete all as specified and directed with MS clamp and nut bolts and washers etc, including taking down old GI tubing alongwith all fixing accessories complete all as specified and as directed.
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately.
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 4 core complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately.
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 2 core complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately.
S&F for ON LOAD Changeover swiches for current rating 125 Amps 4 Pole fitted in sheet steel enclosure, front operated suitable for 415V, 50Hz including contacts accessories complete all as specifid and as directed. Make : Cat No. ICAS0125 of INDOASIAN/L&T/Havells/Legrand.
S&F for OFF LOAD Changeover swiches for current rating 63 Amps 4 Pole fitted in sheet steel enclosure, front operated suitable for 415V, 50Hz including contacts accessories complete all as specifid and as directed. Make : Cat No. OFFP0063 of INDOASIAN/L&T/Havells/Legrand.
Supply, installing, commissioning, testing for deep freezer, 300/320 ltrs capacity, single phase, 230 volt, 50 Hz, aesthetic design, D-cool technology based, energy efficient & Eco-friendly refrigerant with R600a, having metal top single door, with anti bacteria gasket & rotary compressor incl stucco Aluminium inner liner for improved hygiene, spring loaded hibges, with freezer temparature range <-18ºC complete all as specified and as directed. Make: Cat No: GCHW310R6SXB Htop of Godrej/Blue Star/Samsung/LG/Voltas.
S&F for voltage stabilizer for automatic operation with digital voltmeter to monitor in/out voltage with time delay and bypass switch, single phase, thermal overload protection, low & high voltage cut-off protection, LED indication, IC controlled, naturally air cooled indoor type and design for input variation between 170 volts to 250 volts with output output voltage stabilized at 230V with accuracy of +/- 2.5% and of capacity 1 KVA complete all as specified and as directed Make: Andrew Yule/Powerware/Krykard/Voltamp/APLAB
S&F for astronomical time switches, 220 - 240 Volt single phase with 40 A SPN MCB, contactor rating 32 A TP and timmer fitted inside standard steel enclosure suitable for outside conditions, weather & vermin proof, including all connecting accessories and fixing arrangemements as per site requirement complete all as specified and as directed. Make : Cat No. IHXSS0106A of HAVELLS/INDOASIAN/L&T.
S&F for astronomical time switches, 220 - 240 Volt single phase with 40 A SPN MCB, contactor rating 65 A TP and timmer fitted inside standard steel enclosure suitable for outside conditions, weather & vermin proof, including all connecting accessories and fixing arrangemements as per site requirement complete all as specified and as directed. Make : Cat No. IHXSS0312A of HAVELLS/INDOASIAN/L&T.
S&F for UPS for 30 minuts (minimum) backup 3 Phase AC input 300 to 450V output 415V + 1% output voltage three phase, AC, 415V + 1% variation of capacity not less than 4 KVA transformer based online UPS system, DSP technology with IGBT based inverter, battery rack with 12V, SMF VRLA batteries and interconnecting cables complete all as specified and as directed. Make : Cat No. i-MAXX series of Microtek/Exide/Luminous.
M&L for earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete all as specified and as directed.
M&L for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 20 x 3 mm dia by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete as specified and as directed.
S&F for earth continuity conductor or main earthing lead with galvanised iron strip size 20x3 mm, fixed to wall on batten or recesses or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all specification and as directed.
FREEZCON
R D Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .