Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹13.2 L+₹4.1 L (44.4%)Rejected-Finance | L2 | Rejected-Finance Not L1 Bidder |
Tender Value
Refer Docs
EMD Value
₹18,400
Closing Date
16 Jun 2021, 6:00 pmClosed
GARRISON ENGINEER CENTRAL BANGALORE
MILITARY ENGINEER SERVICES GARRISON ENGINEER CENTRAL AGRAM POST BANGALORE 560007
CLEANING REPAIR OF SEWAGE LINES, MANHOLES AND GULLY TRAPS AT VOC, VNC AND DOMLUR, ASC CENTRE NORTH, STN WORKSHOP EME, AGRAM, IBLUR, 70 MAJORS AND 598 ORs AREA, ASC CENTRE AND COLLEGE AND 100 ORs AREA UNDER AGE B R I OF GE CENTRAL BANGALORE
2021_MES_444111_1
8113E
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER CENTRAL BANGALORE
₹18,400
Yes
6 Jul 2021
19 May 2021
18 Jun 2021
19 May 2021
16 Jun 2021
2 Jun 2021
19 May 2021 - 1 Jun 2021
Amount
Cleaning manually of blocked WC, trap, inside house and gully trap including removal/refixing of grating and cleaning of WC's trap,kitchen/bath traps any type/pattern (pedestal/squatting pattern) upto 1st manhole and making the drain pipe of any size full functional by flushing with water to entire satisfaction of Engr-in-Charge including cleaning of 1st manhole and removing the waste material/sludge etc to a distance n.exc 50m and burrying the same in pits complete all as directed by Engr-in-Charge.(Measurement will be carried out each time depend on blockage)
Cleaning/clearing mechanically the sewage line of any description / SGSW pipe of size 100mm dia to 200mm dia at any depth , removing any type of blockage including destling , descaling & dechocking with combine hydralic operated sewer suction cum jetting machine mounted on LCV/HCV by using high pressure thermo plastic water jetting hose and throgh conical ronnd shaped nozzle with piston action rodding from manhole to manhole or from manhole to septic tank / well through sewer line (Measurement will be carried out all as directed by Engr-in-charge.
Cleaning of underground SGSW pipe of size 150mm dia by rodding from manhole to manhole or from manhole to septic tank/well) including taking off manhole cover and cleaning of manholes of any size and depth and removing waste material/sludge to a distance of n.exc 50m and burrying the same in pit and replacing manhole cover in position after cleaning ( Measurement will be carried out each time depend on blockage ) Complete all as directed by Engr-in-Charge.
Cleaning of septic tank and soakage well any size by dewatering, taking out mud/sludge/liquid from septic tanks, soakage wells not exceeding 1.5meter deep getting out and removing & depositing the sludge to a distance not exceeding 100meter in borrow pits, excavating borrow pits and covering the filled borrow pits with minimum 10cm thick layer of earth, and 2 cm thick lime on top surface to prevent spread out of foul smell. After taking out sludge and solid deposits, the inside of the septic tank, etc shall be cleaned with water complete all as specified and directed.
Cleaning of septic tank and soakage well any size by dewatering, taking out mud/sludge/quid from septic tanks, soakage wells exceeding 1.5meter but not exceeding 3.00 meter deep getting out and removing & depositing the sludge to a distance not exceeding 100meter in borrow pits, excavating borrow pits and covering the filled borrow pits with minimum 10cm thick layer of earth and 2 cm thick lime on top surface to prevent spread out of foul smell. After taking out sludge and solid deposits, the inside of the septic tank shall be cleaned with water, complete all as specified and directed.
Demolition of plain cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness. (below or above ground level) and removing debris outside MD land complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing debris outside MD landcomplete all as specified and directed
Demolition of reinforced cement concrete any description and in any position not otherwise specifically provided for etc, cutting reinforcement steel to facilitate demolition of concrete including removing the materials out side MD land complete all as specified and directed.
Demolition of brick work, concrete block masonry or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc including removing the same and debrises outside MD land complete all as specified and directed. Note : - Old serviceable PCC block shall be cleaned properlyand stacked at site for reuse.
Demolition of concrete bed to drain pipe, PCC benching including 150mm dia sewage pipe /salt glazed stoneware drain pipes complete all as directed.
Demolition of concrete bed to drain pipe, PCC benching including 200mm dia sewage pipe /salt glazed stoneware drain pipes complete all as directed.
M&L for precast cement concrete block masonry type C1, 1:3:6 (20 mm graded granite stone aggregate) with solid blocks, exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
All as per item No 12 above but old using serviceable precast cement concrete solid block type C1, 1:3:6 (20 mm graded granite stone aggregate). Note :- Old serviceable PCC solid block retrive under item No 09 shall be used.
Cutting into existing manholes for inserting new drain pipe, 150mm bore and making good to pipe and rendering, cutting out existing benching for and forming branch channel in cement concrete 1:2:4 type B1 finished to match with existing complete all as directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in any type soil (ie combination of soft/loose and hard soil) complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated material to a distance not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for Plain cement concrete 1:2:4, type B-1, (using 20 mm graded stone aggregate) as in coping, kneelers, bed plates etc including weathering slightly rounded or chamfered angles including necessary form work complete all as specified and directed.
M & L for Precast Reinforced Cement Concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in cover slab of drain, etc and set in cement mortar 1:4 including necessary form work, moulds, etc complete all as specified and directed by the Engr-in-Charge. (Note : Reinforcement shall be measured and paid separately)
S & F TMT steel bars 8mm or 10mm dia, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for rendering 15 mm thick on fair faces of brick work/stone masonry or concrete surfaces in cement mortar 1:4, mixed with water proofing compound by weight of cement as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
"Supply only" integral water proofing compound (ISI marked) complete all as specified and directed. (Make : Dr FIXIT/Fosroc/choksey)
Supply and fixing underground Double Wall Corrugated (DWC) pipe, 150mm nominal size (ID 148.50mm & OD 172.50mm), SN- 4, in any length, with rubber ring joints including all fittings, conforming to IS- 16098 (Part- 2) , laid in trenches and testing on completion complete all as directed.
Supply and fixing underground Double Wall Corrugated (DWC) pipe, 200mm nominal size (ID 197.40mm & OD 230.50mm), SN- 4, in any length, with rubber ring joints including all fittings, conforming to IS- 16098 (Part- 2) , laid in trenches and testing on completion complete all as directed.
Harish Constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .