| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹34.2 L+₹3,606.07 (0.11%)Rejected-Finance | L2 | Rejected-Finance Not being L1 bidder | |
| 3 | L3₹36.9 L+₹2.8 L (8.13%)Rejected-Finance C O AKBAR FURNITURE HOUSE MALHAR MORH GARHI UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-Finance Not being L1 bidder | |
| 4 | L4₹38.2 L+₹4.0 L (11.7%)Rejected-Finance NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance Not being L1 bidder | |
| 5 | L5₹39.3 L+₹5.1 L (14.9%)Rejected-Finance HOUSE NO 93 WARD NO 8 NEAR ISKON TEMPLE UDHAMPUR J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-Finance Not being L1 bidder |
Tender Value
₹38.6 L
EMD Value
₹77,200
Closing Date
19 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER SOUTH UDHAMPUR
Udhampur
SPL REPAIR TO HANGAR NO 03 AND ALLIED WORKS AT AVIATION BASE OF 9 I R and O FLT AND PROVN OF PARTITION OF MAIN HALL and OFFICE AT BLDG NO P 62 OF DCN NODE UNDER GE SOUTH UDHAMPUR
2024_MES_638529_1
GE/S(U)- /2023-24
Open Tender
Civil Works
Works
240 days
GE SOUTH UDHAMPUR
As per NIT
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹77,200
9 Mar 2024
22 Jan 2024
20 Feb 2024
22 Jan 2024
19 Feb 2024
5 Feb 2024
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in any type of soil completed all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil completed all as specified and as directed.
Plain cement concrete type D2 1:4:8 (using 40 mm graded aggregate) as in foundations, filling and mass concrete completed all as specified and as directed.
Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 completed all as specified and as directed.
Demolition of brickwork or stone/ boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework complete all as specified and as directed by Engr-in-charge or Garrison Engineer.
40 mm thick cement concrete 1:2:4 type B0 Damp proof course to horizontal or vertical surfaces including necessary formwork including water proofing compound Note : WPC shall be measured seperately completed all as specified and as directed.
Supply only Integral Liquid water proofing compound all as specified and as directed by the Engineer-in-Charge or Garrison Engineer.
Providing, reinforced cement concrete type B-0 (1:2:4) (20mm graded aggregate), in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary formwork completed all as specified and as directed.
Reinforced cement concrete (Design Mix) M-25 (20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span completed all as specified and as directed.
Reinforced cement concrete (Design mix) M-25 (20mm graded aggregate) as in Chajja completed all as specified and as directed.
Flat Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.,rough finished surfaces of concrete completed all as specified and as directed.
Flat Formwork to chullah hoods, chajjas, troughs and similar items including edges.,rough finished surfaces of concrete completed all as specified and as directed.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips completed all as specified and as directed.
Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips completed all as specified and as directed.
Taking down cement plaster from brick/concrete surfaces including raking out joints, hacking for key and scrubbing down with water etc all as specified and directed.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 with WPC at the rate of 3% by weight of cement (Note : WPC will be measured separetely) and is to be finished even and smooth (without using extra cement) completed all as specified and as directed.
Rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth (without using extra cement) completed all as specified and as directed.
Preparation of new plastered surfaces of walls and applying one coat of Chalk whiting, on plastered surfaces, preparatory to distempering completed all as specified and as directed.
Preparing newly plastered wall surfaces and applying two coats of cement based paint over a coat of chalk whitening primer completed all as specified and as directed.
Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering completed all as specified and as directed.
Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface completed all as specified and as directed.
Hardcore of gauge of broken stone or boulders n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface completed all as specified and as directed.
100 mm thick Cement concrete type D2 1:4:8 (40mm graded aggregate) as in sub base flooring completed all as specified and as directed.
25 mm thick plain cement concrete type B1 1:2:4 (20 mm graded aggregate) as in sub base completed all as specified and as directed.
Vitrified ceramic tiles light shade, 10 mm thick (square/rectangular) polished,area of each tiles n exc 0.36 sqm,in floors etc over 15 mm thick screed bed in cement mortar 1:4 set set and jointed in neat cement slurry and pointed in white or coloured cement to match completed all as specified and as directed.
Vitrified ceramic tiles light shade, 10 mm thick (square/rectangular) polished,area of each tiles n exc 0.36 sqm,in skirtings etc over 10 mm thick back coat in cement mortar 1:3 set and jointed in neat cement slurry and pointed in white or coloured cement to match completed all as specified and as directed.
Steel work in tubular trusses including special haped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 completed all as specified and as directed.
Preparation of new steel/zinc or galvanized Surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer in camoflange pattern or plain pattern etc completed all as specified and as directed.
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws completed all as specified and as directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings completed all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness laid bedded and pointed in any mortar as in kitchen platform, floors, aprons etc completed all as specified and as directed.
Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over 15mm thick screed bed in cement mortar 1:4 completed all as specified and as directed.
Rounding to edges of stone slabs one edge, such as in steps , cooking platform, and other similar situations completed all as specified and as directed.
Taking down Chowkhats or frames with shutters (without taking off shutters from the frame) exc 1.5 sq. m but n exc 4 sq. m each completed all as specified and as directed.
Supply and fix powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates (minimum thickness of powder coating 50 micron) including joining cleat for fixing etc. complete all as specified and as directed.
Supply and fix powder coated anodised sliding/hung type aluminium door shutters (minimum thickness of powder coating 50 micron), without sash, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1 No), hinges type B-21 100 mm long (2Nos) suitable handle (1 No), aluminium tower bolt 100 mm (1No) etc. complete all as specified and as directed
Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gaske completed all as specified and as directed.
S & F powder coated anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.(Thickness or powder coating not less than 50 micron) completed all as specified and as directed.
Supply and fix 5.5mm thick sheet glass, ordinary quality and glazing with rubber beading around the glass, in squares complete all as specified and as directed.
S & F 12mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required all as specified and directed
S & F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers all as specified and directed
S & F 18/19mm thick Prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws frame work completed all as specified and as directed.
S&F door closer hydraulically regulated, aluminium (extruded section) body, designation No.2, universal type, suitable for door shutters of 701 to 850mm in width and of weight between 36 to 60 kg etc complete all as specified & directed.
S & F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, completed all as specified and as directed.
S & F Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 completed all as specified and as directed.
Providing and fixing flase ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595 mm x 6mm thick of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99%, NRCO 0.50 to 0.75 as per IS 8225 : 1987, non combustible as per BS 475 (Part 4)-1970 and light reflectance of 85%(minimum) to be laid in true horizontal level suspended on interlocking metal T Grid of hot dipped galvanized iron section of 0.33mm thick (galvanised @ 120 grams per sqm both sides) comprising of main T runners of size 15 x 32 mm of length 3000 mm, cross T of size 15 x 32mm of length 600 mm x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e 50 mm long, 8 mm outer diameter M-6 dast fasteners, 6mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x 0.40mm of length 3000mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450mm centre to centre and 40mm long dry wall wood screws. The work shall be carried out as per specificatins, drawing and as per directions of Engr-in-Charge completed all as specified and as directed.
Dismantling wall and ceiling boards, fibre pulp insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets completed all as specified and as directed.
Pressed steel frames (Factory made) made out of 1.25 mm thick black MS sheet for doors, with one or more rebates including necessary fixing lugs, Butt hinges, lock strike plate, etc complete, size of frame 105x60mm incl bottom of each chowkat completed all as specified and as directed.
Material and labour for plain cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregates as in filling of pressed steel door frame completed all as specified and as directed.
35mm thick Flush shutters, solid core construction, both the faces are covered with decorative face veneer withlipping/frame to match completed all as specified and as directed.
100 mm long aluminium anodised barrel tower bolts of extruded section, fixed in screws complete all as specified and as directed by Engr-in-charge or Garrison Engineer.
Door handle, 100 mm size, aluminium anodised cast type , complete all as specified and as directed by Engr-in-charge or Garrison Engineer.
Supply and fix in 300mm long aluminium anodised, sliding door bolt with hasp, stapple (bolt type) and fixing clip of sheet extruded section+E54 and fixing bolts and sliding bolts of extruded sections complete all as specified and as directed by Engr-in-charge or Garrison Engineer.
Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area completed all as specified and as directed.
Providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight completed all as specified and as directed.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) completed all as specified and as directed.
Plain cement concrete type E2 1:5:10 (using 40 mm graded aggregate) as in foundations, filling and mass concrete completed all as specified and as directed.
Sand filling as a cushioning/ bedding complete all as specified and as directed by Engr-in-charge or Garrison Engineer.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 gradewith grey cement and no pigment complete all as specified and as directed by Engr-in-charge or Garrison Engineer.
Glossy finished Chequered cement concrete tiles 30cm x 30cm x 25mm thick,set, jointed and pointed in neat cement slurry with grey cement and pigment as in floors over 20mm thick screed bed in cement mortar 1:4 completed all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm completed all as specified and as directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point completed all as specified and as directed.
Providing and fixing stainlesssteel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where everrequired) and fitting the same with necessary stainless steel nuts and bolts complete, includingfixing the railing with necessary accessories &stainless steel dash fasteners, stainless steel boltsetc., of required size, on the top of floor orthe side of waist slab with suitable arrangement completed all as specified and as directed.
Dismantling kota stone in slab,flooring any description complete all as specified and directed by Engr-in-charge or Garrison Engineer.
Dismantling wrought iron or mild steel work of any description not otherwise provided etc complete all as specified and directed by Engr-in-charge or Garrison Engineer.
Screed bed or bedding layer of mortar 20 mm thick in cemant mortar 1: 4 laying floor finishes etc complete all as specified and directed by Engr-in-charge or Garrison Engineer.
Kota stone slab flooring 40-50mm thick in flooring laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing, granite cutting and mirror polish finish complete all as specified and as directed by Engr-in-Charge or Garrison Engineer.
Prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick nridge ,hips ,valley gutters at the external end slope of camoflange pattren colour having tensile strength of 550Mpa fixed with self tapping screws complete all as specified and directed by Engr-in-Chargen or Garrison Engineer.
S&F, 0.63mm thick, Galvanised, corrugated mild steel shading with two corrugation side lap, fixed with 'L' type or 'J' type or cranked hook bolts in lieu of screws in roofs.with grade of zinc coating 275. etc complete all as specified and directed by Engr-in-charge or Garrison Engineer.
S&F, 0.63mm thick Plain, black, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed ) etc complete all as specified and directed by Engr-in-charge or Garrison Engineer.
Prepration of old painted and untreated surfaces, applying one coat of synthetic enamel paint over a coat of red oxide primer in camoflange pattern or plain pattern completed all as specified and directed by Engr-in-charge or Garrison Engineer.
10-12 mm thick gypsum boards seamless false ceiling as approved, moisture resistant, including GI hanging wires, along nuts and bolts connecting plates gypsum boards, dry wall screws soffits cleats, ceiling section, rawel plugs fixtures and screws and applying 1 to 1.2mm thick Altek/Birla white putty to obtain smooth/even finish using sand paper and applying two coats of distemper oil emulsion over a coat primer on boards surface etc complete all as specified and directed by Engr-in-charge or Garrison Engineer.
9 mm thick , 5 layer plywood Grade BWP,type BB fixed with screws on timber or steel frame work , etc complete all as specified and directed by Engr-in-charge or Garrison Engineer.
Mild steel Frame as in purlins, crane gantries, rails ,cabinates frmaes and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance Pieces, cleats etc Fe 410 - (Gde- E- 250) quality- A , etc complete all as specified and directed by Engr-in-charge or Garrison Engineer.
Applying two coat of synthetic enamel paint on new wooden surfaces including preparation of newly wooden surfaces over a coat of pink primer, etc complete all as specified and directed by Engr-in-charge or Garrison Engineer.
Rolled mild steel plates (plain ) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to grade Fe.290.Gde-E-165, steel work duly painted with one shop coat of zinc chromate primer including preparation of surfaces etc complete all as specified and directed by Engr-in-charge or Garrison Engineer.
Provision of linear bird proofing of GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metalstudding, joists, etc. in walls, ceilings,stanchions, beams, etc. including alllaps, cutting and waste with riveted, bolted or welded attachment in hanger ceiling ,etc complete all as specified and directed by Engr-in-charge or Garrison Engineer.
Removal & repair and refixing of hanger door and replacement of hanger door wheel including square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to grade Fe.290.Gde-E-165 and realigment of door etc complete all as specified and directed by Engr-in-charge or Garrison Engineer.
S&F 5 mm thick PVC sheet filet of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC Frame as per specification and drawing all as specified and directed by Engr-in-charge or Garrison Engineer.
S&F Solid PVC wall lining consisting of 5 mm thick single side prlam colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawing complete all as specified and directed by Engr-in-charge or Garrison Engineer. Note: PVC sheet filet will be measured and paid sperately.
Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power/ LED Light fittings) complete fitting such as switch, sockets, ceiling rose, pendants socket any type, rectangular board terminal boxes etc and making good disturbed surfaces of walls floors and ceiling complete all as directed.Keeping the LED lights in safe custody completed all as specified and as directed.
Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as specified and directed.
Taking down Old/ Unserviceable MCB DBs TPN / Main Switches by disconnection of electric connection including old unsv MCCBs,MCBs, isolators etc and making good to distrubed surface complete all as specified and directed.
Disconnecting and taking down un serviceable light fittings of any description/ capacity completed all as specified and as directed.
Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit as per site requirement (thickness not less than 1.5mm and 20mm dia), medium grade with Modular sunken boxes & PVC back plate for mounting modular type switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly as specified.Note:- Cutting and making same the wall patchs after laying the wire and conduit using putty, white wash and distamper. The surface should be made smooth using putty and should match exactly with the existing wall finish.
All as per srl item No 85 but for 3 pin 6 Amps socket outlet independent board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly completed all as specified and as directed.
All as per srl item No 85 but for 3 pin 6 Amps socket outlet on the same board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly completed all as specified and as directed.
All as per Srl item No 85 but for 3 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire standard and connected to earth dolly completed all as specified and as directed.
S&F for modular switch 6 Amps single pole one way 230 V, 50 Hz, AC , with inner/outer plate complete all as specified and directed by Engr In charge or Garrison Engineer.
S&F for modular switch 16 Amps single pole one way 230 V, 50 Hz, AC , with inner/outer plate complete all as specified and directed by Engr In charge or Garrison Engineer.
S&F for modular socket 3 Pin 6 Amps flush type 230 V, 50 Hz, AC , with outer/inner cover complete all as specified and directed by Engr In charge or Garrison Engineer.
S&F for modular socket combined 2-in-1, 6 Pin 6 & 16 Amps 230 V, 50 Hz, AC , flush type with outer/inner cover complete all as specified and directed by Engr In charge or Garrison Engineer.
M &L Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Blockcomplete all as specified and directed by Engr In charge or Garrison Engineer.
S&F in replacement single pole and neutral enclosure surface mounted 240 voltswith 2 pin and earth plug and socket with one single pole MCB 20 Amps with indicator of complete all as specified and directed
Supply and fixing in replacement LED lights fitting 1x 20W, 230V,AC decorative box type warm white colour with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-Charge or Garrison Engineer.
S&F in replacement 36W (2 x 2) LED Ceiling/recess light panel for recess mounting warm white colour which provides soft-light and glare free symmetrical illumination complete all as specified and directed by Engineer-in-Charge or Garrison Engineer.
Supply and fixing in replacement LED luminaire 15 watt, 220 V AC recess mounted downlighter type with high efficiency PC diffuser soft light and symmentrical illumination complete with driver, holders & LED lamp warm white suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge or Garrison Engineer.
S&F in replacement Sheet metal enclosure double door type for MCCB TPN DB upto 125 Amps, 4 way vertical type 415 volts with 400 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
S & F replacement MCCB Three Pole & Neutral capacity of 125 amps 415 volts rupturing capacity 16 KA Make completed all as specified and as directed.
S&F in replacement Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 08 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
S&F Sheet metal enclosure double door type for DBs (when MCB to be used) 12 way 240 volts with 200 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification makecompleted all as specified and as directed.
S&F Sheet metal enclosure double door type for DBs (when MCB to be used) 4 way 240 volts with 200 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification completed all as specified and as directed.
S & F in replacement MCB single pole 240 volt any rating from 10 to 40 amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable completed all as specified and as directed.
S & F in replacement MCB single pole and neutral 240 volt any rating from 63 Amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable completed all as specified and as directed.
S&F Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 6 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 6 Sq mm as earth lead completed all as specified and as directed.
S&F Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 10 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 6 Sq mm as earth lead completed all as specified and as directed.
Supply and fixing LED building security light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp,clamps,suitable bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection completed all as specified and as directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers along with all electrical wire connection all as specified and direceted by Engr-in-charge or Garrison Engineer.
Supply and fix ceiling fan, AC single Phase. 230V of size 1200mm sweep with, blades, and frame along with all electrical wire connection all as specified and direceted by Engr-in-charge or Garrison Engineer.
Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x6.3 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized steel earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC 1:2:4 type B-1using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore main board complete all as shown in electrical plate No 5 connected to main control board all as specified and testing on completion. Note: Excavation earthwork charcoal PCC pit is covered under this item including taking out existing earth plate etc.Note: if earth resistance of earthing is not found (2 to 5 Ω) satisfactory if will be redone by the contractor on his risk and cost completed all as specified and as directed.
Material and labour for Fixing & Laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with "XLPE" insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 25 Sqmm x 3.5 core size all as specified including taking down old cable.Note : Earth work and other connected work shall be measured & paid sperately.
Material & Laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with "XLPE" insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 10 Sqmm x 4 core size all as specified including taking down old cable.Note : Earth work and other connected work shall be measured & paid sperately completed all as specified and as directed.
Excavation in trenches and exceeding 1.5m wide and not exc 1.5m in depth in any type of soil and getting out completed all as specified and as directed.
Returing, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick completed all as specified and as directed.
Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
M & L Dry sand for sand cushioning to under ground cable 8 cms thick before laying the cable before and 15 cms thick after laying & streching the cable in trenches, including hand punning and consolidating completed all as specified and as directed. Note : for payment purpose punned thickness shall be measured
M&L Bricks sub class 'B' brick laid dry, flat with width equal to length of brick as cover laid over the cabel to give mechanical protection to underground cabels completed all as specified and as directed.
Supply and fixing GI tubing light grade 40 mm dia along the wall/ in trenches/ in duct / in culvert /road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holdining of GI pipe alongwith polescompleted all as specified and as directed.
Supply and fixing in replacement LED luminaire 15 watt, 220 V AVIATION LIGHT type with high efficiency PC diffuser soft light and symmentrical illumination complete with driver, holders & LED lamp "Two Nos RED LIGHT for Air Traffic Signal" suitable for roof including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge or Garrison Engineer.
Sheet metal enclosure MCB distribution board Triple pole & neutral 415 volts 4 way C Curve with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. (Note-MCBs will be measured separately)
Supply & Fixing MCB TPN 100 Amp, 4 Pole, 415V C Curve Complete all as specified and directed by Engr-in-Charge or Garrison Engineer.
S & F in replacement MCB Single pole and neutral 240 volt any rating from 40 amps"C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going completed all as specified and as directed.
S&F Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 4 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 4 Sq mm as earth lead all as specified. Including taking down old sub main wire (for AC).
S&F Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 2.5 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 1.5 Sq mm as earth lead all as specified. Including taking down old sub main wire(For street light ).
Supply and fixing LED lights fitting 1x 20W, 230V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size completed all as specified and as directed.
LED Panel light 2'x2' capacity 36 Watt extruded aluminium housing with milky diffuser recess mounting ultra modern desinged architectural LED luminaire which provides soft-light and glare free symmetrical illumination suitable for Armstron/Grid ceiling including driver 36 Watt capacity complete making all connection with suitable size flexible cable from ceiling rose to fitting all as per the directions of Engg-in - Charge or Garrison Engineer.
S&F Venza decorative wall mounting light fitting, SS finish fixture with opal glass diffuser including 12W retrofit LED bulb and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one completed all as specified and as directed.
S&F Street light Bracket complete made of GI pipe of suitable size, medium grade 1.2 m long bent to shape as per site requirement along with MS flat iron clamps with nuts, bolts, washers including grouting the same with wall , all as specified and directed by Engg- in-Charge or Garrison Engineer.
S&F in replacement of Sheet metal enclouser single pole and neutral with 2 pin and earth plug and socket 20A 240V complete with one double pole MCB capacity 25 Amp, C Curve, 10KA complete all as specified and directed by Engr-in-charge or Garrison Engineer.
Material & Laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with "XLPE" insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 16 Sqmm x 4 core size all as specified. Note : Earth work and other connected work shall be measured & paid sperately completed all as specified and as directed.
VIRINDER SINGH
M/S ASHOK KUMAR PACHIALA
SINGH CONST CO
khajuria builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .