Executive Engineer
3rd Floor, Purta BhavanSarat Sarani Kodalia Hooghly
Installation of air conditioning machines at main office of the Divisional Commissioner, Burdwan Division
2026_WBPWD_5015356_1
WBPWD/EE/ HED / NIeT-62 of 2026-27
Open Tender
ELECTRICAL WORKS ORG
30 days
Hooghly
Please refer Tender documents.
5 documents required · 5 mandatory
₹19,090
O/O the E.E,HED,PWD,
11 Jun 2026
11 Jun 2026
1 Jul 2026
11 Jun 2026
29 Jun 2026
11 Jun 2026
15 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5-year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC. [Non Schedule Item No. AC MACHINE/ Item No. 2] | ||||||
| 1.1 | Cooling Capacity- 5.2 kW (Minimum) , Air Flow Rate:600 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star(min) [Non Schedule Item No. AC MACHINE/ Item No. 2.2]. | 5 | Each | 1.25 | ₹6.25 | 1.1 |
| 1.2 | Cooling Capacity- 6.1 kW (Minimum) , Air Flow Rate:800 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star(min) [Non Schedule Item No. AC MACHINE/ Item No. 2.3 | 3 | Each | - | - | 1.2 |
| 3 | SITC of 3 TR capacity Tower (Floor Standing), fixed speed split Air-conditioner machine fitted with tropical rotary compressors suitable for Refrigerant - R32 / R410A, air flow-1059 cfm, rated power supply 230 V-1 Ph- 50 Hz along with all accessories (Make - Daikin / Hitachi / Mitsubishi Electric (Star Rating - 2 Star) or equivalent make as approved by EIC. | 2 | item | 100 | ₹200 | 3 |
| 4 | Supply & Laying Extra Add-on items- 5/8" (for gas line) & 1/4" (for liquid line) copper refrigerant pipe with 9 mm. thick nitrile rubber insulation, 4 core x 2.5 sq.mm. copper cable incl. fixing arrangement and wrapping insulation of aerotape complete in all respect for 1.5 / 2 TR A.C. machine as per direction of E.I.C [NS] | 130 | mtr | 100 | ₹13,000 | 4 |
| 5 | Supply & Laying Extra Add-on items- 5/8" (for gas line) & 3/8" (for liquid line) copper refrigerant pipe with 9 mm. thick nitrile rubber insulation, 4 core x 4 sq.mm. unarmoured copper cable incl. fixing arrangement and wrapping insulation of aerotape complete in all respect for 3 TR A.C. machine as per direction of E.I.C [NS] | 54 | mtr | 1.25 | ₹67.5 | 5 |
| 6 | Supplying, fabrication & fixing 2 Nos. M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) of 1m. length for making Base frame for installation of AC ODU incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with 2 Nos. horizontal angle of 50 mm x 50 mm x 6 mm of 1.5m length as per direction of E.I.C incl. Platform. [NS] | 9 | Nos | - | - | 6 |
| 7 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. [Non Schedule Item No. AC MACHINE/ Item No. 5] | 70 | mtr | 100 | ₹7,000 | 7 |
| 81. THE AGENCY MUST PROCURE THE MATERIALS FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES. SALES CHANNEL SO THAT THE STANDARD WARRANTY / SUPPORT OF THE MANUFACTURER / OEM BECOMES APPLICABLE TO THE PRODUCTS TO BE DELIVERED AND INSTALLED BY THEM. 2. DOCUMENTS THAT AUTHENTICATES SUCH PROCUREMENT FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES SALES CHANNEL SO THAT THE STANDARD WARRANTY / SOPPORT SHOULD BE SENT FROM THE e-MALE OF THE MANUFACTURER/OEM / AUTHORIZES SALES CHANNEL TO THE e-MALE OF ENGINEER-IN-CHARGE AND HARD COPY OF IT TO BE SUBMITTED DURING EXECUTION OF WORK/ SUBMISSION OF BILL. 3. IF ANY REFURBISHED MATERIAL IS SIPPLIED ABD INSTALLED, PENAL ACTION WILL BE TAKEN AS PER EXISTING RULES. | ||||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.