Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 CrAccepted-AOC | ₹4.5 Cr Quoted ₹4.7 Cr | L1 | Accepted-AOC SINCE LOWEST BIDDER |
| 2 | L2₹4.9 Cr+₹26.4 L (5.64%)Rejected-Finance | ₹4.9 Cr+₹26.4 L (5.64%) | L2 | Rejected-Finance SINCE NOT LOWEST |
| 3 | L3₹5.1 Cr+₹43.1 L (9.21%)Rejected-Finance 422 MAIN BRANCH MASTER TARA SINGH NAGAR JALANDHAR PUNJAB 144001 | JALANDHAR | PUNJAB | 144001 | ₹5.1 Cr+₹43.1 L (9.21%) | L3 | Rejected-Finance SINCE NOT LOWEST |
| 4 | L4₹5.2 Cr+₹49.7 L (10.6%)Rejected-Finance | ₹5.2 Cr+₹49.7 L (10.6%) | L4 | Rejected-Finance SINCE NOT LOWEST |
Tender Value
₹3.6 Cr
EMD Value
₹4.4 L
Closing Date
2 Jul 2022, 6:00 pmClosed
CE (AF) ALLAHABAD
HQ CE (AF) ALLAHABAD
IMPROVEMENT TO WATER SUPPLY DISTRIBUTION SYSTEM AT AF STN AGRA
2022_MES_525906_1
958439/E8
Open Tender
Civil Works
Item Rate
456 days
GE (AF) TECH AREA AGRA
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
Yes
GE (AF) TECH AREA AGRA
₹4.4 L
Yes
25 Aug 2022
24 May 2022
9 Jul 2022
24 May 2022
2 Jul 2022
18 Jun 2022
Amount
Excavation in trenches in soft loose soil not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation, shafts, wells, cesspits, man holes, laying of cables & pipes etc and trimming of sides & formimg bottom plain or slope and getting out complete all as specified & directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm deoth in soft / loose soil complete all as specified & directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed.
Material & Labour laying well burnt old size bricks, sub class "B" bricks, laid flat with width equal to length of brick, laid dry over electric cable for protection of cable complete all as specified.
Material & labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed.
Material & Labour PCC 1:2:4 type B-2 using 40mm crushed stone aggregate as in surface, chanells and drains complete all as spciified & directed.
Material & labour GI water tubing light grade of 100 mm dia for cable protection on pole/on walls/floor or in trenches etc complete with necessary MS clamp, nut, bolts and washers and socket and making good the disturbed surface of wall, floor complete all as specified and directed.
Material & labour GI water tubing light grade of 150 mm dia for cable protection on pole/on walls/floor or in trenches etc complete with necessary MS clamp, nut, bolts and washers and socket and making good the disturbed surface of wall, floor complete all as specified and directed.
Supply & laying single socketed 400 mm inernal dia Class "K-9" ductile Iron pipe including specials/fittings laid in trenches jointed & tested complete all as specified & directed.
Supply & laying single socketed 300 mm internal dia Class "K-9" ductile Iron pipe including specials/fittings laid in trenches joined & tested complete all as specified and directed.
Supply & laying single socketed 200 mm inernal dia Class "K-7" ductile Iron pipe including specials/fittings laid in trenches jointed & tested complete all as specified and directed.
Supply & laying single socketed 100 mm internal dia Class "K-7" ductile Iron pipe including specials/fittings laid in trenches jointed & tested complete all as specified and directed.
Supply & fixing Cast Iron 450 mm dia Sluice Valves of class PN-1.6, ISI marked, flanged type with stainless steel spindle & Check nut and Iron wheel head complete with Rubber gasket joints of suitable thickness, MS Bolts, nuts and washers of suitable size complete all as specified and directed.
Supply & fixing Cast Iron 400 mm dia Sluice Valves of class PN-1.6, ISI marked, flanged type with stainless steel spindle & Check nut and Iron wheel head complete with Rubber gasket joints of suitable thickness, MS Bolts, nuts and washers of suitable size complete all as specified and directed.
Supply & fixing Cast Iron 300 mm dia Sluice Valves of class PN-1.6, ISI marked, flanged type with stainless steel spindle & Check nut and Iron wheel head complete with Rubber gasket joints of suitable thickness, MS Bolts, nuts and washers of suitable size complete all as specified and directed.
Supply & fixing Cast Iron 200 mm dia Sluice Valves of class PN-1.6, ISI marked, flanged type with stainless steel spindle & Check nut and Iron wheel head complete with Rubber gasket joints of suitable thickness, MS Bolts, nuts and washers of suitable size complete all as specified and directed.
Supply & fixing Cast Iron 100 mm dia Sluice Valves of class PN-1.6, ISI marked, flanged type with stainless steel spindle & Check nut and Iron wheel head complete with Rubber gasket joints of suitable thickness, MS Bolts, nuts and washers of suitable size complete all as specified and directed.
Supply & Fixing cast iron Air Release Valves with two air outlets (combination Valve, Confirming to IS:14845 suitable for 400 mm bore DI pipe duly fixed in DI pipe line by providing necessary jointing materials for jointing as required at site complete all as specified and directed.
Supply and fixing Cast Iron Non Return Valve, Horizontal type with by-pass arrangement 200 mm dia complete with Rubber gasket joints of suitable thickness, MS Bolts, nuts and washers of suitable size complete all as specified and directed.
Supply only MS Casing pipe 700 mm dia of 12 mm wall thick Heavy duty class C, complete all as specified & directed.
Supply only MS Carrier pipe 400 mm dia of 10 mm wall thick Heavy duty class C, complete all as specified and directed.
Material & Labour for valve pit chamber of internal size 1200 x 1200 x 1200mm with brick masonry valve pit chamber, PCC 1:4:8 type D-2 using 40 mm crushed stone as in foundation 150mm thick, one brick thick walls built in CM 1:6, PCC 1:3:6 type C-1 using 20mm crushed stone aggregate as in coping 50mm thick, plastering 15mm thick in CM 1:4 to all internal and exposed surface out side upto 200 mm including necessary excavation and earth work in hard/dense soil, MS sheet cover 3.15mm thickness alongwith angle iron frame of size 40x40x6mm with locking arrangement with necessary fixing materials like but hinges, nut bolts etc Valve pit chamber cover shall be opended in two handles and painting to all mild steel cover surface with two coats of synthetic enamel paint over one coat of red oxide primer internall & externally complete all as specified and directed.
Material & Labour for valve pit chamber of internal size 1500 x 1500 x 1500mm with brick masonry valve pit chamber, PCC 1:4:8 type D-2 using 40 mm crushed stone as in foundation 150mm thick, one brick thick walls built in CM 1:6, PCC 1:3:6 type C-1 using 20mm crushed stone aggregate as in coping 50mm thick, plastering 15mm thick in CM 1:4 to all internal and exposed surface out side upto 200 mm including necessary excavation and earth work in hard/dense soil, MS sheet cover 3.15mm thickness alongwith angle iron frame of size 40x40x6mm with locking arrangement with necessary fixing materials like but hinges, nut bolts etc Valve pit chamber cover shall be opended in two handles and painting to all mild steel cover surface with two coats of synthetic enamel paint over one coat of red oxide primer internall & externally complete all as specified and directed.
Boring of holes under road, railway track, pavement, hard standing by trenchless technology using ultra sounding technique and necessary T&P required suitable laying & jointing of for 700 mm dia casing MS carrier pipe on either side of railway track and laying of 400 mm dia MS pipe including of following connected works to complete the works and testing after completion as directed by Enginner-in-Charge. (i) Excavation for launching pit. (ii) 8mm steel sheeting with girder 200x100 around the pits tie up with 100T jacks (struts). (iii) Steel barricading for blocking the roads etc. (iv) Rent of hydraulic power packs boring machine. iv) Crane/hydra charge with operator & helper. (vi) JCB charges with operator & helper. (vii) Disposal of surplus earth & misc. (viii) Generator 100 KVA rent charge. (ix) PU cutting on both sides.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Demolition of PCC as in path /Black bituminous path/ hard standing or road of any description and in any position not otherwise specially provided for and removing rubbish from site complete all as specified & directed.
Taking up old unserveciable / damaged or rusted GI pipe from trench of 100 mm dia, complete all as specified and directed.
Taking up old unserveciable / damaged or rusted CI/DI pipe from trench of 200 mm dia, complete all as specified and directed.
Taking up old unserveciable / damaged or rusted CI/DI pipe from trench of 300 mm dia, complete all as specified and directed.
Supply, lowering, connecting, testing & commissioning of open well submersible pump set suitable for operate 3 phase, 415 volt AC 50 Hz supply and having ingress protection IP–68, class of insulation ‘B’ ISI marked, complete with cast iron/ stainless steel impeller, Stainless steel shaft and all necessary hardware and pipe fittings /rubber gasket for joints complete suitable to meet the following parameters: a) Operating Head : 25 Mtr approx b) Discharge : 2500 LPM approx c) Capacity 20 HP minimum Make : Kirloskar Brothers Limited/KSB/Calama
S&F electronic fully automatic star-delta starter suitable for upto 20 HP motor, with overload relay, contactors, IP-43 LED Indicators for in control power supply, voltage & Amp display AC-3 phase heavy duty, 415 volts, 50 Hz including fixing arrangement on wall complete all as specified and directed.
S&F PVC insulated PVC sheathed flat copper conductor cable of 10 sqmm 3 core with stranded copper wire complete all as specified and directed.
Supply, laying, testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric under ground LT cable 1100 volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 core complete all as specified and as directed.
Supply, laying, testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric under ground LT cable 1100 volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core complete all as specified and as directed.
Design, supply, erection, testing and commissioning of indoor type Pump Control Panel of overall size not less than 1600mm width x 1200mm Height x 450mm Depth, MS Channel Base Frame mounted (to be mounted on the 3 side covered brick pedestal of height 400mm above floor level) suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 250 Amps, Provision of Spreader link to incoming / outgoing side of MCCBs for termination of cables / busbars and FRP / DMC Cable connectors for termination of outgoing cables from pump starters / MCBs. The Panel shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of panel boards and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 micron) with approved shade of RAL-7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The panel board shall be made out of 2mm thick CRCA mild steel sheet and 2mm thick gland plate and having compartmentalized construction for individual switchgears / Pump Starters and Bus Bars and having front and rear opening facility and detatchable type mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. All the cables entry / exit from the bottom of cable alley only. The panel shall be comprising of the followings :-
Supply & Fixing MCCB 4 pole 250 Amps 25 KA including all fixing arrangement for fixing at existing Sub-Station Panel Board including incoming & outgoing connections complete all as directed.
Supply, erecting, testing & commissioning complete of OEM manufactured, static silient (sound proof enclosure) Disel Engine driven Generating set of capacity 100 KVA, water cooled, 415 volts (AC three phase, 4 wire system of supply) 50 Hz at power factor 0.8 minimum. DG set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, of adequate capacity for 8 hrs running fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangements, exhaust pipe complete and suitable for conditions prevalent at Agra (capacity of engine, alternators shall worked out taking all derating factors into consideration) including foundation (of suitable size leaving at least 0.5m all around for ease of movement and 0.5m height) as per manufacturer recommendation, anti-vibration pads complete all as specified and directed, confirming to emision norms (No + HC < 4.0 gm/kw-hr CO < 3.5 gm/kwhr, PM < 0.2 gm/kw-hr, smoke limit < 0.7 m-¹) including all feature to comply with latest CPCB guidelines and comprising of followings:-
DIESEL ENGINE Diesel engine 1500RPM, direct injection, multi-cylinders, four stroke, conforming to IS:100001/ISO3046/BS: 649/BS: 5514 amended upto date, for continous running capable of taking 10% overload for one hour in 12 hour, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivery 100 KVA at outdoor atmospheric conditions at Agra (Taking all derating factor into consideration) fitting with the following accessories subject ot the design of manufacturer:- (i) Dynamically balanced fly wheel. (ii) Air cleaner oil bath type (iii) Electronic Governor class 1 A with back up Mechanical governor class 1A Flywheel with starter ring (iv) Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level (v) Radiator cooling (vi) Radiator fan with guard (vii) Vaccum indicator (viii) Fuel filter and fuel houses (ix) Fuel injection pump (FIP) (x) Fan and water pump assesembly (xi) Lub oil filter and pump (xii) Electric starting system with battery charging alternator and axial type started motor including adequate number of high capacity maint free lead acid bty as per manufacturer recommendation including inter connecting cables / leads with terminals complete with starting/stopping switch voltmeter 01 set
(xiii) Engine safety shut down system against low oil pressure and high water pressure (xiv) Exhaust gas driven turbo charge (xv) Oil filter (xvi) Lub oil cooler (xvii) Engine maintenance manual with spare part list (xviii) Suitable designed acoustic enclosure as per CPCB regulations (xix) Any other item not included / specified but is a standard design of the manufacturer/required for commissioning/satisfactory operation of DG set. Engine instrument panel : Engine instrument panel shall comprising of the following:- (i) Starting on /off switch. (ii) water temp auge. (iii) Hour meter cum RPM indicator (iv) Lub oil pressure gauge (v) Lub oil temperature gauge (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure. (viii) Any other item not included/specified but is a standard design of the manufacturer.
ALTERNATOR shall be self excited, self regulated, brush less for 100KVA continous operation at the speed of 1500RPM at 415 volts, 50Hz three phase, 4 wire system with advance electronic voltage regulator to ensure high voltage accuracy with +1% with class H insulation and SPDP enclosure directly coupled with engine through flexible couping and conforming to IS-4722 complete-01 No. Note:- Alternator should be able to deliver output rating at actual site condition. Common fabricated base frame for engine and alternator made from structural channel, jerk proof PCC 1:2:4 mix type B1 foundation including adequate number of suitable anti-vibration pads all as per manufacture recommendations is deemed to be included in the unit rate quoted by the contractor. Bottom mounted (or as per manufactures design) steel fuel tank fabricated out of 14 SWG MS sheet of capactiy not less than 12 hrs continous operation inside canopy with fuel level guage, drain plug locking arrangements etc with and including GI pipe connections duly laid as per engineering practice complete all as specifided and directed. Bypass arrangement by providing separate panel made out of 3mm thick CRCA sheet, outdoor type with connecting copper bus bar of suitable size from change over and set of 3 Nos indication lamp for R, Y and B and 2 Nos 4 pole on load change over switch front handle operated of capacity 160 Amp is to be installed near AMF panel complete all as specified and directed. (i) Hour run meter. (ii) Any other item not included/ specified but is a standard design to the manufacturer.
AMF CONTROL PANEL: Supply, fabricating and testing of factory mounted cubical automatic main failure panel with degree of protection IP-42 conforming to IS-2147, suitable for 100 KVA capacity DG Set, fabricated using 14 Gauge CRCA sheet, powder coated comprising of suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming and outgoing leads/ bus bar as approved with and including following accessories:- (i) Master switch for auto/manual/reset/off-01 No. (ii) Ammeter digital type, 96X96 mm with CT's-03 Nos aux supply 230 vlts, AC, acuracy class 1. (iii)Voltmeter digital type 96x96 mm to read 0-500 volts supply 230 volts, accuracy class 1 (iv) Digital frequency meter-01 No aux supply 230 volts, AC (v) Push button start, stop, reset-01 No. (vi) Set of lamp for indicating load a set, low pressure, high cylinder temperature, load on mains, set fails at start, low oil presure. (vi) Battery charger connected to load. (vii) Transformer of adequate rating. (viii) Rectifiers (ix) DC ampere meter and voltmeter. (x) Fault accept / reset push button. (xi) Set of relays and contactor suitable for 100 KVA DG Set for automatic start and automatically shut down of suitable rating and capacity adjustable to 70 to 100% and 2 Nos MCCB 4 pole, 160 Amp, 25 KA fixed on main supply and DG set supply. (xii) Make /design of AMF control panel shall be as per OEM recommendations.
Material & Labour for earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level with top edge of the plate not less than 1.5 M below ground level connected to glavanised iron strip of size 32mm x 6mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified including 40 mm GI tubing medium grade and necessary fitting for protection of GI strip including laying of charcoal and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm crushed stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm crushed stone aggregate reinforced with 6 mm dia round bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick CM (1:6) externally upto 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh including neceary excavation and earth work and removal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point including testing and marking Bldg Nos. XXXXX / Name of Equipments and writing Test Results on a 3mm thick painted MS earth pit marking Plate (200mm x 200mm) duly welded with a 450mm long 10mm dia round MS rod, fixed with the earth pit chamber by grouting complete all as specified and directed.
Deduct Schedule of Credit Rs (-) 2002018.00
Raja enterprises
HARI CONSTRUCTION CO.
M/S JAWAHAR LAL SHARMA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .