Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.7 LAdmitted-Finance | -31.00% | ₹4.7 L | L1 | Admitted-Finance |
| 2 | L2₹4.8 LAdmitted-Finance | -29.33% | ₹4.8 L | L2 | Admitted-Finance |
Tender Value
₹6.8 L
EMD Value
₹13,641
Closing Date
2 May 2026, 3:00 pmClosed
EE/ELD 12
O/o EE/ELD-12, DDA, Paschim Vihar, New Delhi-1100663
Augmentation of Park with 4 mtr. Poles, 30 Watt LED street light, 70watt flood light and allied accessories at NHP Buddha Jayanti Park, Nasirpur under HD-Dwarka.
2026_DDA_906804_1
02/EE/ELD-12/DDA/2026-27
Open Tender
Electrical Works
30 days
Horticulture Division
As per tender notice
12 documents required · 12 mandatory
₹0
₹13,641
Yes
22 May 2026
28 Apr 2026
4 May 2026
28 Apr 2026
2 May 2026
28 Apr 2026
28 Apr 2026 - 2 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, Fabrication and Installation of 4 mtr. high pole made out of 65 mm dia NB, B class G.I pipe ISI marked duly welded with MS base plate of size 300 mm x 300 mm x 12 mm thick and supported with 4 nos stiffner made out of 130mm x 60 mmx 5 mm thickwith suitable earth stud on base plate and collar type mounting arrangement (single or duble fitting type both) for light fitting on the pole, making suitable size hole in pole at a height of 2.5 metre from base plate for cable entry/exit, painting & numbering of pole, making suitable size hole in base plate for cable entry/exit into the pole and fixing the pole on the foundation with the nuts-bolts, washers etc. complete as required. | 6 | Job | 6,107 | ₹36,642 |
| 2 | Providing and laying in position 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) reinforced cement concrete foundation of size 450 mm x 450 mm x 1200 mm deep (800 mm below ground level and 400 mm above ground level) including excavation of earth, refilling, providing, cutting, bending and placing in position, reinforcement of cold twisted bars of 12mm. dia-1200mm long (approx) 8Nos, and reinforcement ring of cold twisted bar of 8mm dia -1400mm long (approx) -6 nos, (with suitable spacing) including centering & shuttering as required with providing, fixing and positioning of one set of foundation bolts comprising of 4 nos., 16 mm dia, 750 mm long J-Type MS bolts (Threaded portion shall be galvanized) along with 3 nos. GI nuts and 2 nos. GI washers etc. per bolt and 1 no. anchor plate (3mm thick) of suitable size and providing 63 mm.(O.D) DWC pipe ISI marked for cable entry & exit etc. complete as required. | 6 | Job | 5,163 | ₹30,978 |
| 3 | Supplying, Fabrication and installation of 4 mtr. high pole made out of 80 mm dia NB, B class G.I pipe ISI marked duly welded including with 4 nos of supports with MS base plate of size 300 mm x 300 mm x 16 mm thick with suitable earth stud on base plate, providing and fixing 1000 mm dia ring type bracket made out of 48 mm dia nominal OD G.I pipe on top of the pole for mounting the 4 nos. light fittings, making suitable size hole in the pole at a height of 2.5 meter from base plate for cable entry/exit for making connection to junction box, painting & numbering of pole, making suitable hole in base plate for cable entry/exit into the pole and fixing the pole on foundation with the nuts-bolts etc. complete as required. | 4 | Job | 10,080 | ₹40,320 |
| 4 | Supplying, Fabrication and replacement of 4 mtr. high pole made out of 80 mm dia NB, B class G.I pipe ISI marked duly welded with MS base plate of size 300 mm x 300 mm x 16 mm thick and supported with 4 nos stiffner made out of 130mm x 60 mmx 5 mm thickwith suitable earth stud on base plate and collar type mounting arrangement (single ) for light fitting on the pole, making suitable size hole in pole at a height of 2.5 metre from base plate for cable entry/exit, painting & numbering of pole, making suitable size hole in base plate for cable entry/exit into the pole and fixing the pole on the foundation with the nuts-bolts, washers etc. complete as required. | 1 | Job | 9,072 | ₹9,072 |
| 5 | Providing and laying in position 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) reinforced cement concrete foundation of size 600 mm x 600 mm x 1200 mm deep (800 mm below ground level and 400 mm above ground level) including excavation of earth, refilling, providing, cutting, bending and placing in position, reinforcement of cold twisted bars of 12mm. dia-1200mm long (approx) 8Nos, and reinforcement ring of cold twisted bar of 8mm dia -1400mm long (approx) -6 nos, (with suitable spacing) including centering & shuttering as required with providing, fixing and positioning of one set of foundation bolts comprising of 4 nos., 16 mm dia, 750 mm long J-Type MS bolts (Threaded portion shall be galvanized) along with 3 nos. GI nuts and 2 nos. GI washers etc. per bolt and 1 no. anchor plate (3mm thick) of suitable size and providing 63 mm.(O.D) DWC pipe ISI marked for cable entry & exit etc. complete as required. | 5 | Job | 7,043 | ₹35,215 |
| 6 | Supplying, installation, Testing & Commissioning of 30 Watt Street light LED fixture powder coatedpressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with
70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report,
CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour
Matching) <5, Maximum power consumption should not more than the specified rating and
Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). DSR 8.13.11 | 8 | Each | 1,553 | ₹12,424 |
| 7 | Supplying, Installation, Testing & Commissioning of 70 Watt Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beamangle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 rurning Hours with 70% of initial Lumen maintained till life ends as per LM80extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM(Standard Deviation Colour Matching) <5,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | 20 | Each | 2,299 | ₹45,980 |
| 8 | Supply & fixing of pole connector box made out of Glass Reinforced Polyester Sheet Moulding Compound Conforming to IS:13410-1992 Grade S1 of outside dimensions 280 mm(H) x 170 mm(W)x 115 mm (D) (all the corners of the box should be round & not pointed ones) suitable to mount on 40/50/65 mm dia GI pole with the following provisions/accessories mounting in box complete as reqd.
(i)2 nos. clamps made out of 19mm x 3 mm GI strip of suitable length for mounting box on the pole.
(ii) Water tight front cover with 2 nos. stainless steel hinges & 1 no. screw for tightening.
(iii)4 way, 220 V, 30 A, dough moulded connector (SMC with stainless steel inserts)
(iv) 16 amp. Moulded SMC rewireable kit-kat---1 no.
(v) Suitable size hole at suitable location on rear wall for cable & wire entry.
(vi) Earthing bolt M6 x 20 mm | 11 | Each | 1,006 | ₹11,066 |
| 9 | Supplying of following sizes of XLPE insulated PVC sheathed Al. cond. Armoured power cable of 1.1 KV grade including connection, testing etc. as required.
a) 2C x 16 sq. mm | 850 | mtr | 200 | ₹1,70,000 |
| 10 | Supplying & drawing following size of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required.
a)3 x 1.5 sq. mm , DSR 1.17.3 | 120 | mtr | 104 | ₹12,480 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.42 MB
NIT.pdf
Tender Documents • 1.60 MB
PWD.pdf
Additional Documents • 1.41 MB
BOQ_953140.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid