Tender Value
₹45.4 L
EMD Value
₹90,700
Closing Date
16 Sept 2026, 4:00 pmDue today
Estates Officer, SKUAST-Jammu
Estates Division, SKUAST-Jammu, Chatha
Repair and restoration of Cold Vaults and associated works in the Ex Situ Gene Bank of Institute of Biotechnology at Main Campus, Chatha
2026_SKUST_323171_1
AU/Estates/2026-27/07 dated 14-08-2026
Open Tender
Electrical Works
Item Rate
180 days
Main Campus, Chatha
Please refer tender documents
4 documents required · 4 mandatory
₹1,500
Assistant Comptroller (Estates), SKUAST-Jammu
₹90,700
16 Sept 2026
2 Sept 2026
17 Sept 2026
2 Sept 2026
16 Sept 2026
2 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Repairing of 75 KVA oil cooled servo voltage stabilizer 3 phase by way of replacing of dimmer / veriable (3 nos.) including cost of old material and replacing of synchronizing motor 10kg (3nos.) motor network bacalite plate Microsoft switch (3 nos.) wiring for auto control Micro Processor card (3 nos.) bearing variable socket (3nos.) volt meter 96mm 300 volt (3 nos.) front plate push button (6 nos.) togal switch (6 nos.) and indicator 12 nos. complete job | 1 | No | - | - |
| 2 | Repairing of condensing unit | 5 | No | - | - |
| 3 | Repair of Dehumidifier | 3 | No | - | - |
| 4 | Replacement of control panel | 1 | No | - | - |
| 5 | Lifting of condensing unit | 5 | No | - | - |
| 6 | Repair of puff floor panel | 1 | No | - | - |
| 7 | Repair of 62.5 KVA DG set | 2 | No | - | - |
| 8Supply and laying of PVC power cable 1.1 KV grade armoured aluminium XLPE, cables including earth work cost of end termination thimbles and saddies etc as required | |||||
| 8.1 | 3.5C x 120 sq mm | 60 | Meter | - | - |
| 9Supply, installation, testing at works, installation and commissioning of following distribution boards totally enclosed compartmentalized cubicle indoor type fabricated with 16 SWG sheet steel, with aluminium bus bars (both for main and neutral bus bars), complete with following switchgear / mountings cable terminations inter-connections as required for 415 volts, 3 phase, 4 wire 50 HZ AC supply as per specification and drawings Moulded case circuit breakers shall be internal magnetic trip type fault level for all MCCB and bus bar shall be 35 KA ICU shall be equal to ICS = 100% Note : All metering current transformers shall be class 1, 15 VA | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
TermsandConditionsoftheContract.pdf
Tender Documents • 0.22 MB
BOQ_1086921.xls
BOQ • 3.26 MB
Corrigendumextension1.pdf
PDF • 0.23 MB
Corrigendumextension.pdf
PDF • 0.22 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .