Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹34.5 LAccepted-AOC HOUSE NO 165 A VILLAGE POST MORTA DISTT GHAZIABAD U P PIN 201003 | GHAZIABAD | GHAZIABAD | UTTAR PRADESH | 201003 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹37.9 L+₹3.4 L (9.71%)Rejected-Finance D 55 HAKIKAT RAI RD ADARSH NAGAR DELHI 33 | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹38.8 L+₹4.3 L (12.4%)Rejected-Finance | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹39.5 L+₹5.0 L (14.6%)Rejected-Finance N A | NA | NA | 121004 | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹41.7 L+₹7.2 L (20.8%)Rejected-Finance | L-5 | Rejected-Finance L-5 |
Tender Value
₹45.8 L
EMD Value
₹91,600
Closing Date
22 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) FARIDABAD
GE (AF) FARIDABAD
PROVN OF GUEST ROOMS AT OFFICERS MESS AT AF STN DADRI IN AOR OF GE (AF) FARIDABAD
2024_MES_643843_1
GE (FBD)/AF-91/2023-2024
Open Tender
Civil Works
Item Rate
180 days
DADRI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹91,600
Yes
10 Apr 2024
23 Feb 2024
23 Mar 2024
23 Feb 2024
22 Mar 2024
8 Mar 2024
23 Feb 2024 - 27 Feb 2024
Amount
Excavation in trenches n. exc 1.5 m wide and 1.5 m deep or for foundation etc and for shafts, wells, manholes or similar items n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exc. 50m and depositing where complete all as specified and directed by Engineer-in-Charge.
M&L, PCC 1:4:8 type D-2(using 40mm graded stone aggregate)as in foundation , filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
Returning filling in incl spreading ,levelling,watering,and well ramming in layers n exc 25 cm in soft loose soil complete all as specified and directed by Engineer-in-Charge.
M & L brick work with sub class 'B' bricks(old size bricks) straight or curved on plan exc 6 m mean radius built in cm 1 : 6 with and including weep holes in brick work complete all as specified and directed by Engineer-in-Charge.
Material and labour reinforcement TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
Material and labour reinforcement TMT bars 5 mm dia and over up to and including 10mm dia in stirrups,spacers and binders, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter on flat surface, rough finished complete all as specified and directed by Engineer-in-Charge.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.rought finished complete all as specified and directed by Engineer-in-Charge.
M&L RCC M-25 20mm graded crushed stone aggregate for Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L RCC M-25 20mm graded crushed stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge.
Rendering, 15 mm thick, in cement mortar 1:6, over brick or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Supply only integral water proofing compound conforming to IS-2645-1975 complete all as specified and directed by Engineer-in-Charge.
Rendering,15 mm thick, in cement mortar 1:4 over brick or concrete surfaces, finished fair and even without using extra cement, mixed with water proofing compound @ 3% by weight of cement complete all as specified and directed by Engineer-in-Charge. Note:-Integral water proofing compound shall be measured and paid separately
M&L PCC 1:2:4 type B1 using 20mm graded aggregate as in fdn filling kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engineer-in-Charge.
S&F structural steel as in roof trusses (framed), trussd purlins, crane gantries, rails and fastenings and heavy bracket framing( Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe 410 -W (Gde - E 250 quality A) complete all as specified and directed by Engineer-in-Charge.
S&F mild steel work as in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St-240 complete all as specified and directed by Engineer-in-Charge.
S & F Plates (plain or chequered) channels, Fe 410-W(Gde?E- 250) square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed by Engineer-in-Charge.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5cm and n exc 30cm long dia 16 to 20 mm complete all as specified and directed by Engineer-in-Charge.
S&F, Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F, Pre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
Preparation of new steel surfaces and applying two coats of synthetic enamelled paint over a coat of red oxide, zinc chrome complete all as specified and directed by Engineer-in-Charge.
M&L 75 mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection complete all as specified and directed by Engineer-in-Charge.
M&L, Hardcore of broken stone of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:2:4 type B-1 using 20mm graded stone agg 40 mm thick complete all as specified and directed by Engineer-in-Charge.
M&L for 600mmx600mmx10 mm thick coloured vetrified Light shade tiles shade as approved flooring( in any pattern) and jointed with neat cement slurry over 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor complete all as specified and directed by Engineer-in-Charge.
M&L for 600mmx600mmx10 mm thick coloured vetrified Light shade tiles shade as approved ( in any pattern) in vertical surfaces as skirting and jointed with neat cement slurry over fixed to wall as skirting with 10 mm thik cement sand mortar in CM 1: 4 ,and pointed with coloured cement matching with surfaces of tiles as in floor complete all as specified and directed by Engineer-in-Charge.
M&L for coloured printed non skid tiles area of each tile exceeding exc 0.11 sqm but n.exc 0.18 sqm in floors etc set and jointed with neat cement slurry pointed with colour cement to match the floor, and including 15 mm thick screed bed cement mortar in CM 1:4 and including the chipping of the existing PCC floor ccomplete all as specified and directed by Engineer-in-Charge.
M&L for digital design glazed ceramic tiles in vertical surface of size of each tile 300 x 450 mm and 7 to 8 mm thick fixed to wall with 10 mm thik cement sand mortar in CM 1: 4 , set and joint in neat cement slurry and pointed in white or coloured cement to match the same complete all as specified and directed by Engineer-in-Charge.
M&L for 300mmx300mmx10-12mm thick coloured vetrified outer side parking tiles as approved flooring( in any pattern) and jointed with neat cement slurry over 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor complete all as specified and directed by Engineer-in-Charge.
M & L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including cutting and polishing types nd including 20mm thick screed bed in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M &L for new plastered surfaces and applying two coat of external emulsion paint over 3 mm thick wall care putty complete all as specified and directed by Engineer-in-Charge.
M&L two coat of oil bound distemper after 3mm Birla/JK wall care putty on new plastered surfaces including necessary prepararion complete all as specified and directed by Engineer-in-Charge.
S&F, powder coated aluminium frames for doors,windows, ventilators & partitions with one or more rebates including jointing cleat for fixing and suitable aluminium powder coated handles, tower bolts and door stopers including fixing to floor with suitable screws/fasteners in partiton etc complete all as specified and directed by Engineer-in-Charge.
S&F, Powder coated aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed by Engineer-in-Charge.
S&F, Powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed by Engineer-in-Charge.
M & L for 12mm thick both sides prelaminated Particle board, exterior grade, fixed with screws to timber frame work in cup board shutters/ shelves and in partitions complete all as specified and directed by Engineer-in-Charge.
M&L Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring into brick wall+ etc. and making good, cutting exceeding 20cm girth complete all as specified and directed by Engineer-in-Charge.
S&F GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floor , 15 mm bore of tube, complete all as specified and directed by Engineer-in-Charge.
S&F GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floor , 20 mm bore of tube, complete all as specified and directed by Engineer-in-Charge.
S&F, 20 MM Gun-metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and complete all as specified and directed by Engineer-in-Charge.
S& F, 20 mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in repair and complete all as specified and directed by Engineer-in-Charge.
S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge.
S&F, Vetrious china top counter type wash hand basin, white flat back size 600 mm X 475 X 210 mm mm including cutting for and pinning in ends of barakets or erecting stand complete all as specified and directed by Engineer-in-Charge.
S&F PVC connection 15 mm bore 450 mm in length complete all as specified and directed by Engineer-in-Charge.
S&F brass CP soap dish of approved quality complete all as specified and directed by Engineer-in-Charge.
S & F brass CP tower rail, 600mm long of consisting three rod , brackets complete all as specified and directed by Engineer-in-Charge.
S & F PVC 110 mm (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with clamps and for sewage line complete all as specified and directed by Engineer-in-Charge.
S & F PVC 75 mm (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with clamps and for sewage line complete all as specified and directed by Engineer-in-Charge.
S & F PVC 75 mm (SWR) bends any radius complete all as specified and directed by Engineer-in-Charge.
S & F PVC 100 mm (SWR) bends any radius complete all as specified and directed by Engineer-in-Charge.
S & F PVC (SWR), junction single, (Single T) equal or unequal 75 mm complete all as specified and directed by Engineer-in-Charge.
S & F PVC (SWR), junction single, (Single T) equal or unequal 110 mm complete all as specified and directed by Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position complete all as specified and directed by Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) of 500 Ltrs capacity hoisted and fixed in position complete all as specified and directed by Engineer-in-Charge as per SSR Pt- I
S&F 15 mm angle valve chromium plated with wall flange and fancy type with high pressure screwed down and with CP flange of same make complete complete all as specified and directed by Engineer-in-Charge.
S&F Bib taps, cast copper alloy with crutch or butterfly handle, screwed for iron pipe or brass ferrule, long body 15mm, fancy type complete all as specified and directed by Engineer-in-Charge.
S & F 15mm chromium plated swivel shower rose with or without swivel joints sny size for fixing with 15 mm pipe incl shower arm 15 mm size , 195 mm long with bend of 45 degree complete all as specified and directed by Engineer-in-Charge.
S&F Brass CP wall mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S&F Brass CP centre hole WHB mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S&F, Vitreous China premium/ 1st quality wash down water closet wall hung EWC white or coloured incl P or ‘S’ trap coloured ,incl seat cover, flushing cistern, flush pipe & cement concrete bedding, complete all as specified and directed by Engineer-in-Charge.
Cast iron floor trap, with grating including jointing to waste pipe fixed in cement oncrete type B-1 (1:2:4) complete all as specified and directed by Engineer-in-Charge.
S&F door closer hydraulically regulated designation No 2, aluminium (Die cast) body, universal type suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 Kg fixed & repair complete all as specified and directed by Engineer-in-Charge.
S&F in repair Curtain rod Stainless steel 25 mm dia 1mm thick with pairs of fixing fancy type brackets heave grade, Fancy type supprting stops heavy grade, rollers including screws with required accessories and finishing the surface with existing wall surface etc complete all as specified and directed by Engineer-in-Charge.
Providing & fixing false ceiling with semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles, at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter?locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main?T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and L?shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in?Charge
S&F 12 mm thick Toughened glass partition with one door with All accessories(Suitable stainless steel handle 2 Nos, stainless steel Joint cleats, Suitabel floor spring and with suitable stainless steel upper framing), including fixed to walls and floors with suitable clips and filling materials complete all as specified and directed by Engineer-in-Charge.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm tickness , M-40 grade, set, jointed and pointed in neat cement slurry in floors with grey cement & pigments complete all as specified and directed by Engineer-in-Charge.
M&L 30 mm thick for sand cushioning for laying of inter locking tiles (paving blocks) complete all as specified and directed by Engineer-in-Charge.
Concrete bed to drain pipes150 mm dia including packing under, and hunching against the sides of pipes after they are laid and tested complete all as specified and directed by Engineer-in-Charge.
M&L for RCC drain pipes class NP3 With collors 150 mm dia laid in trenches and joints complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:3:6 type C2 ( 40mm graded aggregate) as in sub base and mass concrete all as specified and as directed by Engineer-in-charge.
M & L brick work with sub class 'B' bricks(old size bricks) straight or curved on plan exc 6 m mean radius built in cm 1 : 4 with and including weep holes in brick work complete all as specified and directed by Engineer-in-Charge.
Providing precast cement concrete type B-1 1:2:4 in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed by Engineer-in-Charge.
M& for point wiring (conceated) in and incl rigid non-metaic PVC conduit, ISI marked 19/20 mm dia, with 1.5 sqmm PVC insulated unsheathed stranded copper conductor cable, single core, 1100 volts grade with, cast iron/pressed steel terminal box of suitabe sizes & 1.6 mm thick duly painted inner & outside by anti-corrosive paint, for mounting switches, sockets, fan regulator etc with mudular cover plates and incl PVC insulated & unsheathed stranded copper conductor of 1.5 Sqmm as continious earth wire for the following complete all as specified and directed by Engineer-in-Charge. (a) one light/fan/bell point controlled by one switch incl continuous earth wire for connection to fan clamp, regulator and earth dolley
All as per item No 76 above but but for 3 pin 5 Amps socket on Same board .
All as per item No 76 above but for 3 pin 5 Amps socket on independent board .
All as per item No 76 above but power point wiring (concealed) with 2.5 Sqmm singe core PVC insulated unsheathed cable with stranded copper conductor for one switch socket outlet, 5/15 Amps muti purpose on independent modular plate including PVC unsheathed copper conductor of same dia as earth wire
M & L for Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/ recessed 2x4.0 sq. mm + 1x2.5 sq. mm earth wireas required complete all as specified and directed by Engineer-in-Charge.
M&L for Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/ recessed 2x 6.0sqmm + 1x 4 sqmm earth wire in PVC conduit complete all as specified and directed by Engineer-in-Charge.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20Amps for AC complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Switch modular type,Modular switch 1 way 6A, 1 module complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed by Engineer-in-Charge.
Suppy and fixing modular Fan step regulator, 120W - 2 module complete all as specified and directed by Engineer-in-Charge.
S&F ceiling rose 65x50 mm 3 terminal complete all as specified and directed by Engineer-in-Charge.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engineer-in-Charge.
S&F White cover frame with plate - 3 module complete all as specified and directed by Engineer-in-Charge.
S&F White cover frame with plate - 6 module complete all as specified and directed by Engineer-in-Charge.
S&F White cover frame with plate - 8 module complete all as specified and directed by Engineer-in-Charge.
M&L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Engineer-in-Charge.
S&F sheet metal enclousers MCB type DB suitable VTPN 4 way 200 Amp rated bus bar double door type complete all as specified and directed by Engineer-in-Charge.
S&F sheet metal enclousers MCB type DB suitable SPN 12 way 200 Amp rated bus bar double door type complete all as specified and directed by Engineer-in-Charge.
S&F MCCB 3 Pole .415 V. fixed type, 25 to 100 Amps with breaking capacity 16 KA , 240 V complete all as specified and directed by Engineer-in-Charge.
S&F MCB TPN capacity 32 Amps, 240 V complete all as specified and directed by Engineer-in-Charge.
S&F MCB SPN capacity 32 Amps, 240 V complete all as specified and directed by Engineer-in-Charge.
S&F MCB SP capacity 6-32 Amps, 240 V complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3½ core complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for laying of cables/ poles or foundation etc getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting pointcomplete all as specified and directed by Engineer-in-Charge.
M&L for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed by Engineer-in-Charge.
Supply of brick sub class B laid dry in trenches over the cable ad joining each other widthwise for cable protection complete all as specified and directed by Engineer-in-Charge.
M&L for boring of holes under road pavement, motor hardstanding by trenchless technology using ultra sound technicque and necessary machine including HDPE pipe of 150 mm dia suitable foor 40 MPA working pressure complete all as specified and directed by Engineer-in-Charge.
Supply and fix Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 meter long) complete with CI base plate and finial including foundation and coping complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED Bollard light fitting IP 54 powder coated PDC aluminium body with opal diffuser suitable for landscape lighting incl making necessary arrangement for mounting fitting as reqd on site and testing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED Post top fitting 40 Watt 5700 K CCT IP 65 powder coated aluminium die cast and spun aluminium with clear diffuser suitable for landscape lighting inclmaking necessary arrangement for mounting fitting as reqd on site and testing complete all as specified and directed by Engineer-in-Charge.
Supply and lay pipe galvanized, “Medium class”, including fittings 50 mm (2”) dia complete all as specified and directed by Engineer-in-Charge.
Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm (1”) dia complete all as specified and directed by Engineer-in-Charge.
Supply and lay pipe galvanized, “Medium class”, including fittings 20 mm (13/4”) dia complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for laying of cables/ poles or foundation etc getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Supply and fix 50 mm (2”) dia pipe Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge.
Supply and fix 20 mm (3/4”) dia pipe Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge.
M&L for drilling and tapping existing castiron pipe for for branch connection for 20mm dia GI pipe including necessary excavation and earth work etc complete all as specified and directed by Engineer-in-Charge.
GARG CONSTRUCTION CO
36SHRI RADHEY ASSOCIATES
Gaurav India Corporations
M/S Yamin
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .