Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
30 Aug 2022, 3:00 pmClosed
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR REPLACEMENT OF UNSERVICEABLE FPB LT PANEL LT UG CABLE AND SOME EXTERNAL ELECTRIC WORKS IN RS AREA AT NAVY NAGAR UNDER GE NW NAVY NAGAR COLABA MUMBAI
2022_MES_542878_2
8249/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (NW) Navy Nagar, Colaba
Class D and Category b(i)
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹76,000
Yes
18 Oct 2022
3 Aug 2022
31 Aug 2022
3 Aug 2022
30 Aug 2022
17 Aug 2022
3 Aug 2022 - 23 Aug 2022
Amount
M&L for replacement of LT panel board at R-3 garden, factory made pedestal cubical double door outdoor type, CPRI approved, modular construction fabricated out of 3.15 mm thick MS sheet, epoxy powder coated to give superior finish, totally enclosed, dust and vermin proof with locking arrangement (compartment wise) front & back side opening system including air louvers at both side, rain shed 15 cm all around, overall size of each incoming & out going modules should not be less than ( 350mm x300mm x400mm ), platform mounted having minimun clearance of 450 mm above ground level suitable for 415 Volts 3 phase 4 wire system 50 Hz supply, having ETP grade copper busbar strip (three phase & neutral) duly tapped in colour coded FRP sleeves install on porcelain /epoxy insulator, floor mounted type based on angle iron frame and legs 50x50x5 mm thick, front and rear opening with double shutter and having locking arrangement with 50 mm lock make Navtal or Harrison with three keys and including grouting of panel with necessary PCC work complete all as specified. The scope of work including provision of housing the following accessories:- (Make of Panel - L&T/Legrand India Pvt Ltd/Standard Incoming: - (i) MCCB 400 Amp 4 pole 36 KA 415 V with microprocessor release having protection against over current, earth fault, short circuits and inbuilt battery and display system - 01 No. Make: Schneider, L&T or Legrand. (ii) On Load Changeover switch 400 Amp, 415V, 4 pole with open execution with front handle - 01 No. Make: Schneider, L&T or Havells. (iii) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, L&T, AE, Havells. (iv) Digital type Amperemeter (0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability - 01 Nos. Make: Securemeters, L&T, AE, Havells (v) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (vi) Tinned copper bus bar strips made of copper of size 50x8mm suitable length- 04 Nos
Outgoing: - (i) MCCB 250 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 01 No. Make: Schneider, L&T or Legrand. (ii) MCCB 200 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 05 No.s Make: Schneider, L&T or Legrand. (iii) All outgoing MCCB shall be connected through spreader and copper busbar not less than 5 mm thick strip. Note: (1) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (2) Before fabrication of panel the contractor has to take approval from accepting officer on drawing.
All as per Item No.1 above but scope of work including provision of housing the following accessories:- (Make of Panel - L&T/Legrand India Pvt Ltd/Standard Incoming: - (i) MCCB 630 Amp 4 pole 36 KA 415 V with microprocessor release having protection against over current, earth fault, short circuits and inbuilt battery and display system - 01 No. Make: Schneider, L&T or Legrand. (ii) On Load Changeover switch 630 Amp, 415V, 4 pole with open execution with front handle - 01 No. Make: Schneider, L&T or Havells. (iii) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, L&T, AE, Havells. (iv) Digital type Amperemeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability - 01 Nos. Make: Securemeters, L&T, AE, Havells. (v) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (vi) Tinned copper bus bar strips made of copper of size 50x10mm suitable length-04 Nos Outgoing: - (i) MCCB 400 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 01 No. Make: Schneider, L&T or Legrand. (ii) MCCB 250 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 01 No. Make: Schneider, L&T or Legrand. (iii) MCCB 200 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 06 No.s Make: Schneider, L&T or Legrand. (iv) All outgoing MCCB shall be connected through spreader and copper busbar not less than 5 mm thick strip. Note: (1) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (2) Before fabrication of panel the contractor has to take approval from accepting officer on drawing.
All as per Item No.1 above but scope of work including provision of housing the following accessories:- (Make of Panel - L&T/Legrand India Pvt Ltd/Standard Incoming: - (i) MCCB 630 Amp 4 pole 36 KA 415 V with microprocessor release having protection against over current, earth fault, short circuits and inbuilt battery and display system - 01 No. Make: Schneider, L&T or Legrand. (ii) On Load Changeover switch 630 Amp, 415V, 4 pole with open execution with front handle - 01 No. Make: Schneider, L&T or Havells. (iii) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, L&T, AE, Havells. (iv) Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability - 01 Nos. Make: Securemeters, L&T, AE, Havells. (v) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (vi) Tinned copper bus bar strips made of copper of size 50x10mm suitable length-04 Nos Outgoing: - (i) MCCB 250 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 04 No. Make: Schneider, L&T or Legrand. (ii) MCCB 200 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 04 No. Make: Schneider, L&T or Legrand. (iii) MCCB 100 Amp 4 pole 25 KA 415 V with thermal magnetic release, Ics=100% Icu. - 02 No.s Make: Securemeters, L&T, AE, Havells. (iv) All outgoing MCCB shall be connected through spreader and copper busbar not less than 5 mm thick strip. Note: (1) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (2) Before fabrication of panel the contractor has to take approval from accepting officer on drawing.
All as per Item No.1 above but scope of work including provision of housing the following accessories:- (Make of Panel - L&T/Legrand India Pvt Ltd/Standard Incoming: - (i) MCCB 630 Amp 4 pole 36 KA 415 V with microprocessor release having protection against over current, earth fault, short circuits and inbuilt battery and display system - 01 No. Make: Schneider, L&T or Legrand. (ii) On Load Changeover switch 630 Amp, 415V, 4 pole with open execution with front handle - 01 No. Make: Schneider, L&T or Havells.
(iii) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, L&T, AE, Havells. (iv) Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability - 01 Nos. Make: Securemeters, L&T, AE, Havells (v) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (vi) Tinned copper bus bar strips made of copper of size 50x10mm suitable length-04 Nos Outgoing: - (i) MCCB 250 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 04 No. Make: Schneider, L&T or Legrand. (ii) MCCB 200 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 04 No. Make: Schneider, L&T or Legrand. (iii) All outgoing MCCB shall be connected through spreader and copper busbar not less than 5 mm thick strip. Note: (1) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (2) Before fabrication of panel the contractor has to take approval from accepting officer on drawing.
All as per Item No.1 above but scope of work including provision of housing the following accessories:- (Make of Panel - L&T/Legrand India Pvt Ltd/Standard Incoming: - (i) MCCB 250 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 01 No. Make: Schneider, L&T or Legrand. (ii) On Load Changeover switch 250 Amp, 415V, 4 pole with open execution with front handle - 01 No. Make: Schneider, L&T or Havells. (iii) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, L&T, AE, Havells. (iv) Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability - 01 Nos. Make: Securemeters, L&T, AE, Havells (v) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (vi) Tinned copper bus bar strips made of copper of size 40x6mm suitable length-04 Nos
Outgoing: - (i) MCCB 160 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 02 No. Make: Schneider, L&T or Legrand. (ii) MCCB 125 Amp 4 pole 25 KA 415 V with thermal magnetic release, Ics=100% Icu. - 02 No. Make: Schneider, L&T or Legrand. (iii) MCCB 63 Amp 4 pole 25 KA 415 V with thermal magnetic release, Ics=100% Icu. - 02 No. Make: Schneider, L&T or Legrand. (iv) Power contactor 4 pole 40 Amp, 415 V - 02 No. Make: Schneider, L&T or Legrand. (v) Analog time switch 3 module - 02 No. Make: Schneider, L&T or Legrand. (vi) All outgoing MCCB shall be connected through spreader and copper busbar not less than 5 mm thick strip. Note: (1) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (2) Before fabrication of panel the contractor has to take approval from accepting officer on drawing.
All as per Item No.1 above but scope of work including provision of housing the following accessories:- (Make of Panel - L&T/Legrand India Pvt Ltd/Standard Incoming: - (i) MCCB 200 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 01 No. Make: Schneider, L&T or Legrand. (ii) On Load Changeover switch 200 Amp, 415V, 4 pole with open execution with front handle - 01 No. Make: Schneider, L&T or Havells. (iii) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, L&T, AE, Havells. (iv) Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability - 01 Nos. Make: Securemeters, L&T, AE, Havells (v) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (vi) Tinned copper bus bar strips made of copper of size 40x6mm suitable length-04 Nos Outgoing: - (i) MCCB 63/100 Amp 4 pole 25 KA 415 V with thermal magnetic release, Ics=100% Icu. - 06 No.s Make: Schneider, L&T or Legrand. (ii) All outgoing MCCB shall be connected through spreader and copper busbar not less than 5 mm thick strip. Note: (1) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (2) Before fabrication of panel the contractor has to take approval from accepting officer on drawing.
M&L for replacement of LT panel board at R-11, R-22 and R-25, factory made pedestal cubical single door, indoor type, CPRI approved, modular construction fabricated out of 2.0 mm thick MS sheet, epoxy powder coated to give superior finish, totally enclosed, dust and vermin proof with locking arrangement (compartment wise) front side opening system including air louvers at both side, overall size of each incoming & out going modules should not be less than ( 350mm x300mm x350mm ), platform mounted having minimun clearance of 450 mm above ground level suitable for 415 Volts 3 phase 4 wire system 50 Hz supply, having ETP grade copper busbar strip (three phase & neutral) duly tapped in colour coded FRP sleeves install on porcelain /epoxy insulator, floor mounted type based on angle iron frame and legs 40x40x5 mm thick, including grouting of panel with necessary PCC work complete all as specified. The scope of work including provision of housing the following accessories:- (Make of Panel - L&T/Legrand India Pvt Ltd/Standard Incoming: - (i) MCCB160 Amp 4 pole 25 KA 415 V with thermal magnetic release, Ics=100% Icu. - 01 No. Make: Schneider, L&T or Legrand. (ii) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Schneider, L&T or Havells. (iii) Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability - 01 Nos. Make: Securemeters, L&T, AE, Havells. (iv) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (v) Tinned copper bus bar strips made of copper of size 40x5mm suitable length-04 Nos Outgoing: - (i) MCCB 63/100 Amp 4 pole 25 KA 415 V with thermal magnetic release, Ics=100% Icu. - 04 No.s Make: Schneider, L&T or Legrand. (ii) MCB TPN 40 Amp 10 KA 415 V - 02 No.s Make: Schneider, L&T or Legrand. (iii) All outgoing MCCB shall be connected through spreader and copper busbar not less than 5 mm thick strip. Note: (1) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (2) Before fabrication of panel the contractor has to take approval from accepting officer on drawing.
M&L for in replacement of MCCBs thermal magnetic release,lcs=100% lcu in existing FP/panel, connecting to bus-bar with all connecting accessories and modification in busbar (if Necessary), connection complete and testing after completion, all as specified and directed, of following capacities :- Make-Legrand/Schneider/L&T/Havells/C&S
MCCB 63/100 Amps,16 kA, TP, 50 Hz.
MCCB 160 Amps, 36 kA, FP, 50 Hz.
MCCB 200 Amps, 36 kA, FP, 50 Hz.
MCCB 250 Amps, 36 kA, FP, 50 Hz.
MCCB 400 Amps, 36 kA, FP, 50 Hz.
M&L for in replacement of Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, L&T, AE, Havells
M&L for in replacement of Digital type Amperemeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability complete all as specified. Make: Securemeters, L&T, AE, Havells
Excavation in trenches not exc 1.5 mtr wide and not exc1.5 mtr in depth for laying of cables etc. in any type of soil and getting out all as specified and directed by Engineer-in-Charge. Note : Rate includes removing of paver blocks carefully and stack properly for refixing after laying of cables .
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils.
Removing excavated material from the site of work to outside MD land complete all as specified.
Supply, filling, spreading levelling and well ramming the river sand around cable in trenches for cable cushioning all as specified and directed. Note : Punned thickness shall be measured and paid.
Supply and laying un-reinforced pecast concete cable covers class LV, Type 1, flat, size 250mmx 150mm x 40mm all as specified and directed.
Cutting existing road surface or hard standing, bituminous topping 15 cm but n exc 30cm girth for laying of pipes/ cables and making good distrubed surface to match with existing complete.
M&L for making good of road cutting upto 450 mm wide, clean the cutting surfaces and filling hardcore and match the existing bitumen surface of road with premix bitumenous material ready to use complete all sa specified and directed by Engr-in-charge.
M & L for cement concrete 1:4:8 type D2 (using 40mm grade stone aggregate) as in foundations, filling and mass concrete finished fair and even comlpete all as specified
Supply, Fixing, testing and commissioning of XLPE insulated armoured, heavy duty electric cable with aluminium conductor of size 240 sqmm 3.5 core, 1100 volt grade laid in trenches, fixed on wall, passing through pipes complete including connecting with MCCB/ busbar with the help of proper size thimble, glands, properly as directed by engineer-in-charge and taking out existing damaged unserviceable cable. Note : Excavation, earthwork and cable protection shall be measured and paid separately under relevant items.
Same as Item No 19.00 above but size 150 Sq mm, 3.5 core
Same as Item No 19.00 above but size 120 Sq mm, 3.5 core
Same as Item No 19.00 above but size 95 Sq mm, 3.5 core
Same as Item No 19.00 above but size 50 Sq mm, 3.5 core
Same as Item No 19.00 above but size 35 Sq mm, 3.5 core
Same as Item No 19.00 above but size 25 Sq mm, 3.5 core
M&L for in replacement of GI pipe ,light grade 50mm dia for road crossing of cable for cable protection or above ground surface including taking out old one all as specified and directed.
M&L for in replacement of GI pipe ,light grade 80mm dia for road crossing of cable for cable protection or above ground surface including taking out old one all as specified and directed.
M&L for in replacement of GI pipe, light grade 100mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
M & L for fixing of old interlocking paver tiles/blocks of any sizes recovered form item SI. No. 11 including laying over 50 mm thick sand bed compacted complete as specified and directed.
M & L for 60 mm thick coloured interlocking paver tiles/ blocks, lacquer finish of existing size and existing type and including laying over 50 mm thick sand bed compacted complete as specified and directed.
M&L for in replacement of High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 40mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
M&L for in replacement of High density poly-ethylene pipes (HDPE) of pressure 4 kgf/cm2 pipe, 75mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
M&L for in replacement of High density poly-ethylene pipes (HDPE) of pressure 4 kgf/cm2 pipe, 100/110mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
Material and labour for fault finding on LT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.
Supply and fix cable jointing kit Straight Through Joint for 1.1KV grade cable complete with Jointing material (Heat shrinkable) and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 25 to 95 sq mm after taking out and cutting the faulty cable area, inserting 1 mtr Cable of existing size for jointing Cables if required at site and all as directed by Engineer-In-Charge. Make- Denson/3M/M-Seal
All as per Item No 35.00 above but for 3.5 core XLPE armoured, alluminum conductor cable of size 120 to 185 sq mm and all as directed by Engineer-In-Charge. Make- Denson/3M/M-Seal
All as per Item No 35.00 above but for 3.5 core XLPE armoured, alluminum conductor cable of size 240 to 300 sq mm and all as directed by Engineer-In-Charge. Make- Denson/3M/M-Seal
M&L for taking out existing Panel and shifting of LT panel of any size with all accessories and fixing it to other location as directed by Engr-in-Charge at site, connecting cable connection with connecting accessories, incl foundation in PCC 1:3:6 type C2 all as specified and directed.
M & L for earthing with copper earth plate electrode 600mm x 600mm x 3.15 mm burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth not less than 1.5 mtr below ground level connected to the connecting copper strip 20 x 3 mm and including GI pipe 40 mm dia light grade for protection to the extend of 7.5 mtr as earthing lead by means of copper nuts, bolts as per connecting to equipment with provn charcoal and salt complete all as per electric plate No 5 of SSR Part-1 including PCC chamber with RCC cover watering arrangement with GI pipe 20 mm dia medium grade and MS funnel, including excavation and earth work and returning, filling in including ramming and removal of surplus soil and testing on completion complete.
NOEL ENGINEERS
shree arihant constrution
AGRAWAL ASSOCIATES
shubham construction
Shree Ayyappa Engineering
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .