| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-AOC R C PANDIT LANE NAMOPARA PURULIA | PURULIA | PURULIA | WEST BENGAL | 723101 | L1 | Accepted-AOC STANDS L1 SATISFACTORILY | |
| 2 | L2₹3.9 L+₹3,799.46 (0.99%)Rejected-Finance 266 1 S B GORAI ROAD BESIDE VIDYASAGAR MAIDAN ASANSOL 713301 | ASANSOL | BURDWAN | WEST BENGAL | 713301 | L2 | Rejected-Finance NOT L1 BIDDER | |
| 3 | L3₹3.9 L+₹6,445.26 (1.68%)Rejected-Finance KALYANESWARI PASCHIM BARDHAMAN WEST BENGAL | KALYANESWARI | PASCHIM BARDHAMAN | WEST BENGAL | L3 | Rejected-Finance NOT L1 BIDDER |
| Sl No | Description | Qty | Unit | SUNRISE ENGINEERING CORPORATION L3 | M/S. SWAPAN BANERJEE L2 | Premnath Mitra L1 |
|---|---|---|---|---|---|---|
| 1.00Supply and delivery of following materials at site(For 3 Panel VCB Repairing):- | ||||||
| 1.01 | 6 window, micro-processor based alarm annunciator, 220-230 V DC/AC auxiliary supply.(Make:-minilec, Model No:-2 6B 0S P0) | 2 | Nos | 12,180 ₹24,360 | 12,100 ₹24,200 | 12,029 ₹24,058 Lowest |
| 1.02 | 4 Core X 4.0 Sq. mm. Armoured, XLPE insulated Extruded PVC type ST2 Outer sheathed Copper Power Cable as per IS:7098(Part-I).(Make:-Gloster/Approved Make)(From LT PDB to VCB for spring charging Motor) | 90 | Mtrs | 781 ₹70,290 | 778 ₹70,020 | 776 ₹69,840 Lowest |
| 1.03 | 2.5/4 Sqmm Cu pin & ring type socket, compression gland.(Make:-Dowells/Other approved make) | 1 | Item | 1,580 ₹1,580 | 1,550 ₹1,550 | 1,502 ₹1,502 Lowest |
| 1.04 | 10 Core X 2.5 Sq. mm. Armoured, XLPE insulated Extruded PVC type ST2 Outer sheathed Copper control Cable as per IS:7098(Part-I). (Make-Gloster/Approved Make)(From Marshalling Box of TR1 & TR2 to VCB OG-1 & OG-2 Panel) | 16 | Mtrs | 1,214 ₹19,424 | 1,210 ₹19,360 | 1,201 ₹19,216 Lowest |
| 1.05 | Over current and earth fault relay for HT side.(Make:-Schneider, Model No-P-111) | 1 | No | 45,200 ₹45,200 | 45,100 ₹45,100 | 44,987 ₹44,987 Lowest |
| 2.00 | Atfirst removing damaged annaunciator, relay etc from the HT panel, then fitting, fixing new one in the existing place, then laying of cable from HT panel to 500 KVA transformer, through the trench also functioning the OTI & WTI signalling, spring charging motor of VCB system as per direction. | 1 | Item | 16,150 ₹16,150 | 15,990 ₹15,990 | 15,960 ₹15,960 Lowest |
| 3.00 | Charges for PT Dismantling, Rubbing, Cleaning to be done by applying CRC, WD-40. After that heating treatment to be done, then varnishing to be done by applying Red Insulation Varnish to improve the IR value, after improving the IR value finally re-fitting of PT and PT Kept in Line as per direction of EIC. | 2 | Item | 23,500 ₹47,000 | 23,300 ₹46,600 | 23,100 ₹46,200 Lowest |
| 4.00 | Charges for 3 nos. Current transformer dismantling, Rubbing, Cleaning, Heating/baking, varnishing by applying CRC, WD-40, red insulation varnish for IR improvement and finally Re-fitting of Incomer in outgoing panel no-02 as per direction of EIC. | 6 | Item | 9,990 ₹59,940 | 9,950 ₹59,700 | 9,900 ₹59,400 Lowest |
| 5.00 | Charges for 11 KV VCB racked out from 11 KV panel, properly cleaning to be done by applying CRC, WD-40. After that heating treatment to be done for IR Improvement, after IR improving 11 KV VCB Racked In inside Panel and power charging at Outgoing-2, as per direction of EIC. | 1 | Item | 11,260 ₹11,260 | 11,200 ₹11,200 | 11,000 ₹11,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹8,000
Closing Date
1 Jun 2026, 4:00 pmClosed
Executive Engineer,AMD P.H.E dte
Office of the Executive Engineer,Asansol Mechanical Division,Public Health Engineering Directorate,PASCHIM BARDHAMAN,713305
Repairing and Overhauling of 11 KV 3 Panel(1 I/C and 2 O/G) VCB/HT Panel, 11KV/0.433KV, 500 KVA, indoor type transformer, LT PDB Cum MCC Panel at Pansuli Haed Works under R.C.F.A. Part-III(Zone-I) Water Supply Scheme.
2026_PHED_1024167_1
WBPHED/EE/AMD/ NIeT-01 of 2026-2027
Open Tender
Miscellaneous Works
Item Wise
15 days
Pansiuli
Please refer Tender documents.
4 documents required · 4 mandatory
₹8,000
10 Jul 2026
13 May 2026
3 Jun 2026
13 May 2026
1 Jun 2026
13 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply and delivery of following materials at site(For 3 Panel VCB Repairing):- | |||||
| 1.01 | 6 window, micro-processor based alarm annunciator, 220-230 V DC/AC auxiliary supply.(Make:-minilec, Model No:-2 6B 0S P0) | 2 | Nos | 1 | ₹2 |
| 1.02 | 4 Core X 4.0 Sq. mm. Armoured, XLPE insulated Extruded PVC type ST2 Outer sheathed Copper Power Cable as per IS:7098(Part-I).(Make:-Gloster/Approved Make)(From LT PDB to VCB for spring charging Motor) | 90 | Mtrs | 2 | ₹180 |
| 1.03 | 2.5/4 Sqmm Cu pin & ring type socket, compression gland.(Make:-Dowells/Other approved make) | 1 | Item | 3 | ₹3 |
| 1.04 | 10 Core X 2.5 Sq. mm. Armoured, XLPE insulated Extruded PVC type ST2 Outer sheathed Copper control Cable as per IS:7098(Part-I). (Make-Gloster/Approved Make)(From Marshalling Box of TR1 & TR2 to VCB OG-1 & OG-2 Panel) | 16 | Mtrs | 4 | ₹64 |
| 1.05 | Over current and earth fault relay for HT side.(Make:-Schneider, Model No-P-111) | 1 | No | 5 | ₹5 |
| 2 | Atfirst removing damaged annaunciator, relay etc from the HT panel, then fitting, fixing new one in the existing place, then laying of cable from HT panel to 500 KVA transformer, through the trench also functioning the OTI & WTI signalling, spring charging motor of VCB system as per direction. | 1 | Item | 6 | ₹6 |
| 3 | Charges for PT Dismantling, Rubbing, Cleaning to be done by applying CRC, WD-40. After that heating treatment to be done, then varnishing to be done by applying Red Insulation Varnish to improve the IR value, after improving the IR value finally re-fitting of PT and PT Kept in Line as per direction of EIC. | 2 | Item | 7 | ₹14 |
| 4 | Charges for 3 nos. Current transformer dismantling, Rubbing, Cleaning, Heating/baking, varnishing by applying CRC, WD-40, red insulation varnish for IR improvement and finally Re-fitting of Incomer in outgoing panel no-02 as per direction of EIC. | 6 | Item | 8 | ₹48 |
| 5 | Charges for 11 KV VCB racked out from 11 KV panel, properly cleaning to be done by applying CRC, WD-40. After that heating treatment to be done for IR Improvement, after IR improving 11 KV VCB Racked In inside Panel and power charging at Outgoing-2, as per direction of EIC. | 1 | Item | 9 | ₹9 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
2911.pdf
Tender Documents • 0.51 MB
BOQ_2517045.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .