Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹24.1 L+₹14,830 (0.62%)Rejected-Finance 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹25.3 L+₹1.3 L (5.43%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹25.3 L+₹1.3 L (5.53%)Rejected-Finance H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹25.8 L+₹1.8 L (7.51%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
27 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL SANDEEP KUMAR
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
COMPREHENSIVE AND PREVENTIVE MAINT OF LT DISTRIBUTION SYSTEM, PROTECTIVE SYSTEM, UG CABLES AND LT OVERHEAD ELECTRIC SUPPLY LINES AND CONNECTED WORKS AT NEW CANTT AREA UNDER GE(NORTH) PATIALA
2023_MES_631390_1
GE(N)/TOKEN-78/2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
PATIALA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE NORTH PATIALA
₹70,000
Yes
15 Jan 2024
6 Dec 2023
29 Dec 2023
6 Dec 2023
27 Dec 2023
20 Dec 2023
Amount
M & L for Earthing complete with galvanized earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground to the depth of not less than 2.25 mtr below ground level with top edge of earth plate or a depth not less than 1.50 m below ground level connected to GI strip 32 x 6mm as earth lead by means of galvanized bolts, nuts check nuts and washers and necessary excavation and earth work PCC 1:2:4 type B-1 using 20mm graded brick aggregate for earth pit RCC cover , charcoal & common salt filled in alternate layers funnel with 20mm bore light grade watering pipe, 40mm dia GI pipe light grade for protection of GI strip, wire mesh and connected to earth point including testing on complete all as specified and shown in electric plate No 3 of SSR Part I.
M&L in replacement for GI strip 32 x 6 mm as earth continuity conductor or main earthing lead beyond test point fixed to wall on batten or recess or chases or buried in ground or drawn in conduit pipe complete all as specified and directed.
Supply and fix including replacement of old existing insulators from wall and recess, by elapped red DMC earthing GI strip insulators including fixing them by nut and bolts properly, for electrical installation and for lightning arrestor for ( GI strip ) of any size installation fixed on wall and recess complete all as specified and as directed.
Supply and fix in replacement air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed.
Supply and fix in replacement mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed.
M & L in replacement stay assembly 20 mm dia complete with accessories as shown in electrical plate No. 1 all as specified and directed. Note:- (loop type insulator, stay clamps, excavation and concrete measured separately)
Supply and fix in replacement of stay wire galvanized iron stranded of size 7/3.15 mm,length of stay wire not exceeding 11 mtrs with each stay and fixed to stay and pole including tightening complete all as specified and directed.
M&L for dismantling of ACSR conductors after unbinding from insulators Note:- (i) Total no of conductors in over head line to be taken down shall comprise a maximum of three phase, one neutral ,one street light/security light for measurement length of each conductor shall be taken separately complete all as specified and directed
Supply and fixing of ACSR conductor of any size as per site requirement to be drawn straight horizontal on over head lines on existing poles including binding with insulators. Weight of conductor shall be measured straight horizontal distance between centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag, jointing jumpers,etc complete all as specified and directed.
M&L for streching and tightning of existing ACSR conductor any size on LT pole 9 mtr long all as specified (one span consists of 5 ACSR conductors 1 earth wire and cradle guard) includind replacement of J hooks complete all as specified.
Taking down carefully galvanized iron steel wire drawn straight horizontal as continuous earth wire on existing LT poles of size 4.0 mm dia from LT over head lines, after unbinding from insulators for replacement incl Restringing/ restretching to dismantled serviceable G I wire complete all as specified and directed. Note:- (i) Replaced G I wire shall be measured and paid under respective item supply only of sch for measurement length of each wire shall be taken separately.
Supply and fix in replacement Galvanised iron steel wire 3.15 or 4mm dia,incl tightening and restringing existing loose / broken continuous GI wire 4 mm dia on existing LT over head lines including stringing all as required at site complete all as specified and as directed.
Supply,laying, commissioning and testing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade laid in duct / trenches for small length for extension/replacement of the defective cable of nominal cross sectional area 95 sqmm 3.5 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed. Note :-(i) Pipes and bricks for protection, mild steel clamp nut and bolts sand cushioning shall be measured and paid separately.
All as per item No. 13 here-in before but for cable of size 3.5 core 120 sqmm.
All as per item No. 13 here-in before but cable of size 3.5 core 185 sqmm.
All as per item No. 13 here-in before but cable of size 3.5 core 240 sqmm.
All as per item No. 13 here-in before but cable of size 3.5 core 300 sqmm.
Refixing and relaying and testing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade in duct / trenches for small length for extension/replacement of the defective cable or existing temporary cables laid in air of any size and specification , including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed. Note :- (i) Old serviceable cable of any size obtained from site which is temporary fixed / issued by AGE E/M office shall be relay at site as per direction of Engr-In-charge. (ii) Excavation, Pipes and bricks for protection, mild steel clamp nut and bolts sand cushioning shall be measured and paid separately
M&L for Painting to existing PCC pole of any type with Black and yellow synthetic enamel paint over existing paint up to 1.5 m height from bottom alternatively strips 30 cm each including painting of ,clamps, nut, bolts and MS channel with aluminum paint including providing pole number with white enamel paint and 100 mm dia (round) background of blue enamel paint at site complete all as specified and directed
M&L for Painting to existing steel tubular pole of any type complete with MS channel ,clamps,nut,bolts with two coat of aluminium synthetic enamel paint from bottom to top of the pole inculding black and yellow paint upto 1.5 Mtr height from bottom alternatively strip 30 cm each including providing pole number with white enamel paint and 100 mm dia (round) background of blue enamel paint at site complete all as specified and directed.
M&L for Painting to existing LT panel board/sub station's door shutters of installed in sub stations or installed in indoor/outdoor type of any size complete with two coat of weather proof synthetic enamel spray paint over a coat of red oxide primer after preperation of the surface complete all as specified and as directed by Engr-in-Charge.
M&L for Painting to existing XPM fencing fixed in at substation and for outdoor LT panel boards or for fencing around power house of any type complete with two coat of weather proof synthetic enamel spray paint over a coat of red oxide primer after preperation of the surface complete all as directed by Engr-in-Charge.
S&F Mild Steel work Fe-290 Gde E-165 as in fencing posts, drilling holes, notching for wire etc including cutting and twisting necessary drilling bolting and rivetting or welding etc and similar works complete all as specified and directed by Engineer in Charge.
S & F Framed work such as grills, gratings etc, with ends of bars shouldered and /or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railing; framework of water tanks and similar work conforming to Fe 410-0 or Fe-310-0 complete all as specified and as directed.
M&L for preparing steel and iron new surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil including removing green vegetation, roots, bushes,etc from surrounding of LT feeder Boards/Poles/substations etc complete all as specified and directed
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1,5 mtr in depth for laying of cables errecting of pole including getting out in any kind of soil complete all as specified and directed.
.-ditto as above but exceeding 1.5 m depth but n exc 3.00 m depth.
Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer of any kind of soil complete all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M & L for Clean dry sand laid in trenches/ducts for bedding and cushioning to cable, including spreading and leveling complete, all as specified. Note:-(i) Consolidated/punned down sand shall be considered for purpose of payment.(ii) Sand shall be same as specified for plastering work.
M & L for precast concrete cable covers type 2 flat, size 250mmx150mmx40mm laid dry in trenches for cable protection all as specified and directed by Engineer in Charge.
M&L for dismantling insulators any type, any size from LT poles complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement loop type insulators porcelain shackle type vitreous white, brown or green of size 65x90mm overall dimension and 20mm clearence hole all as specified and directed by Engineer-in-Charge,
Supply and fix in replacement shackle type porcelain vitreous, white brown or green insulator for working pressure 1.1 kv of size 100mm height and 115 mm dia including galvanized mild steel straps of section 38 x 5 mm size ,20 mm dia bolt nut and washers complete all as specified and directed .
Supply and fix in replacement guy insulator for LT stay, porcelain vitreous, white brown or green insulator for working pressure 1.1 kv of size 110 mm X 75 mm or as per existing shape and size . Complete all as specified and as directed .
M&L for PCC 1:2:4 type B-2 using 20 mm graded broken stone aggregate as in mass concrete in foundations of stay and grouting of Lt panel, filling of road cutting etc complete all as specified and directed .
Supply,laying and in replacement galvanised steel tubing light grade complete with all fitting of size 50 mm dia for cable protection along with pole across road etc. Complete all as specified and directed by Engr-in-Charge.
All as per item Ser No 38 above but size of pipe 80 mm dia.
Boring of holes under road, pavement, hard standing by trench-less technology using ultrasound technique and necessary machine suitable to pass through 40 to 80 mm bore GI tubing and cable etc complete all as specified and directed.
M &l for PCC 1:4:8 TYPE D-2 using 40 mm graded broken stone aggregate as in mass concrete in foundations etc . complete all as specified and directed.
Cutting hard standing / road for laying of cable / protection pipe complete all as specified and as directed.
Supply and fix in replacement of New generation energy saving and environmental friendly long life LED building security light 1x25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP66 protection and impact resistance of IK07, with all accessories including suitable bracket with 32 mm bore light grade GI pipe bend to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twin core from ceiling rose to light fittings complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement of elegantly designed sleek surface mounted pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and independent electronic LED driver of capacity 15 watt with flexible wire 0.5 sqmm copper cable all as specified & directed by Engr-in-charge.
S & F in replacement of new generation energy saving and environmental friendly long life industrial 80 Watt LED High Bay luminaries with clear PC diffuser powder coated Aluminium body IP 65 mounting with eye bolt and PVC cable 1.5 Sqmm twin core from ceiling rose to light fittings complete all as specified and directed.
Supply and fix in replacement of Surface Mounted LED Bulk Head Luminaire of capacity 10 watt with ABS Body & Polycarbonate Diffuser, IP54 inc connection with ,with flexible wire 0.5 sqmm copper cable all as specified & directed by Engr-in-charge.
S & F Sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 4.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2(two) Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 4.00 Sqm Copper conductor Earth wire shall be measured as one unit) Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc. 10 cm girth . (iii) Including taking out/down existing unserviceable sub main wiring.
S & F MCCB, 4 Pole, 63 A, 16 KA for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and directed by Engineer-in-charge.
Supply and fix epoxy power coated MCCB distribution box double door VTPN 4 way vertical type AC 415 V with IP 43 protection for MCBs alongwith provision of MCCB as incomer with commen bus-bar at incoming end of outgoing MCBs grouted/ flush to wall, complete all as specified by Engineer-in-charge. (Note :- MCCB will be measured and paid under seperate item) (i) Cost of Eye/bottle thimbles used for connection MCBs in DBs shall deemed to be included in unit rate quoted for this items, (ii) Electric wiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. (iii) connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped. all the vacant holes of the DB shall be provided with blank plates of appropriate size complete all as specified and directed by Engr-in-charge.
S & F MCB, single pole 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed by Engineer-in-Charge.
M & L for Earthing complete with galvanised steel earth plate electrode, 600x600 x 6.0mm thick buried directly in ground(earth pit not less than 2.25m deep below normal level) connected to galvanised earth lead wire 4.0mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No 3 of SSR Part I. Connected to earthing test point testing complete including necessary earth pit chamber PCC 1: 3: 6 type C1, and 50mm thick RCC 1 : 2: 4 chamber cover and with 8mm dia mild steel re-enforcement @ 15Cm C/C spacing both ways with a handle made of 8 mm bar for fitting, galvanised iron funnel, wire mash watering pipe GI 20 mm dia light grade, and protection to earth lead shall be provided with GI pipe light grade 15mm dia up to 7.5m from the earth plate electrode, excavation including charcoal and common salt in alternative layers 15 cm Thick mixed refilling of soil etc complete all as directed by Engineer-in-charge.
S & F Sub main wiring with two single core 1.50 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through New PVC concealed conduit 20 mm dia including 1.50 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2(two) Runs of 1.50 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 1.50 Sqm Copper conductor Earth wire shall be measured as one unit) Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 20 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc. 10 cm girth . (iii) Including taking out/down existing unserviceable sub main wiring.
Supply and fix in replacement of LED post top fitting 40 W powder coated aluminium die cast and spun aluminium with clear/opal diffuser suitable for landscape lighting in IP 65 complete all as specified and directed by Engr-in-charge. Note: Cost of GI pipe 40 mm light grade and PCC foundation for pole grouting, each length of pipe will be not less than 4 feet, grouting holes into pipe and cement work has been included in the quoted rate against this item complete all as specified and directed by Engr-in-charge.
Supply and fix new generation, energy saving, environment friendly, long life aesthetically designed aluminium landscape IP 65 luminaire for diffused lighting with high power LED as light source LED Bollard pathway lights of capacity 10 watt made up of aluminium pipe UV protected pure polyester powder coated having colour temperature(CCT) 3000K fixed to concrete foundation by means of 3 nos M10 bolts complete all as specified and directed by Engr-in-charge. Note:- Cost of PCC foundation of suitable height , PVC conduit 25 mm of suitable length, all electrical connection and all other items whichever required for fixing is deemed to be included in the unit rate quoted for this item.
S & F XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 2 core supplied & laid complete all as specified& directed by Engineer-in-Charge.
Supply and fix incl taking down LED garden/ bollard light fitting with LED bulb upto 20 watt E27/B22 base cap fitted on the piller with the help of GI pipe/PCC upto 550 mm height nut bolts and in stainless steel housing with clear acrylic cover in top section with IP 65 protection class, connection with 1.5 sqmm 3 core copper cable including making suitable PCC foundation and all electrical connection complete all as directed by Engr-in-charge.
Supply and fix PVC insulated copper conductor 3 core 1.5 sqmm passing through flexible PVC conduit and fixed with clamp complete all as specified and directed. Note:- Cable and flexible conduit shall be deemed to included in quoted rates.
Arneja Builders
Sukhdev Ram
Jawandha Enterprises
Gurcharan Singh Enterprises
SWAMI ENGINEERS
SHARMA ELECTRICAL ENGINEERS
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .