Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-AOC LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹11.6 L+₹2.2 L (23.4%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹11.9 L+₹2.5 L (26.6%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹12.0 L+₹2.6 L (27.2%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹21.1 L+₹11.7 L (124.2%)Rejected-Finance 00 A N SINHA ROAD KADAM KUAN PATNA BIHAR 800003 | PATNA | BIHAR | 800003 | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
1 Oct 2024, 6:00 pmClosed
Shri Ankit Goyal, IDSE
GE Dronachal, Dronachal Top, Neori Hills, Bhopal 462038
REPAIR/MAINT AND IMPROVEMENT OF SEWAGE PUMP HOUSE, LT PANEL, EARTHING WITH ALLIED WKS AT DRONACHAL UNDER GE DRONACHAL
2024_MES_671306_1
8847/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bhopal
Class-E, Category b (i) and as per NIT documents
6 documents required · 6 mandatory
₹500
Garrison Engineer Dronachal
₹30,000
Yes
6 Mar 2025
3 Sept 2024
3 Oct 2024
3 Sept 2024
1 Oct 2024
17 Sept 2024
3 Sept 2024 - 10 Sept 2024
Amount
Taking out old copper cable and S&F in Copper cable of size 25 sqmm three core, 440 Volt 50 Hz,draw in PVC conduit of including taking out old cable, complete all as specified and directed.
Taking out old copper cable and S&F in Copper cable of size 35 sqmm three core, 440 Volt 50 Hz,draw in PVC conduit not less than 25 mm including taking out old cable, complete all as specified and directed.
Taking out old copper cable and S&F in Copper cable of size 50 sqmm three core, 440 Volt 50 Hz,draw in PVC conduit not less than 25 mm including taking out old cable, complete all as specified and directed.
Taking out old UNSV Foot valve any size and S&F foot valve Cast iron body flange type ISI marked including nut, bolt all connected fitting including taking down old foot valves complete all as specified and directed of following sizes :-
Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 63 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed.
Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 100 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed.
Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 250 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed.
Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 400 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed.
Taking out old contractor & S&F in replacement power contactor, type ML-4, 3 pole, 415V, 50Hz, 3 Phase, with auxilary contacts 2 NL&T
Taking out old contractor & S&F in replacement power contactor, type ML-6, 3 pole, 415 V, 50Hz, 3 Phase with auxilary contacts 2 NO + 2 NC complete all as specified and directed.
Taking out old contractor & S&F in replacement power contactor, type ML-2, 3 pole, 415 V, 50Hz, 3 Phase with auxilary contacts 2 NO + 2 NC complete including taking out all as specified and directed.
Taking out old contractor & S&F in replacement electronic timer for Star Delta Starter type, timing range 3-30 sec, 415 V, 50 Hz complete including taking out all as specified and directed.
S&F in replacement thermal over load relay for Star Delta Starter type, range 5-30 amp, 415 V, 50 Hz complete including taking out all as specified and directed.
S&F in replacement thermal over load relay for Star Delta Starter type, timing range 66-120 amp, 415 V, 50 Hz complete including taking out all as specified and directed.
S & F fully automatic star delta starter suitable upto 15 HP submerssible pump set ,415 Volts, 50 Hz, 3 Phase including relay, contactor ,no volt coil,on-off switch,indicators (R Y B) and electrical wiring all as specified and directed.
S & F fully automatic star delta starter suitable upto 60 HP submerssible pump set ,415 Volts, 50 Hz, 3 Phase including relay, contactor ,no volt coil,on-off switch,indicators (R Y B) and electrical wiring all as specified and directed.
S & F fully automatic star delta starter suitable for 40 HP submerssible pump set ,415 Volts, 50 Hz, 3 Phase including relay, contactor ,no volt coil,on-off switch,indicators (R Y B) and electrical wiring all as specified and directed.
Taking out old submersiblle cable and S&F submersible flat copper cabl e of size 10 sqmmX3 core , 220 volt , 50 Hzall specified and directed.
S&F in replacement DOL starter of relay range 2 to 5 amp in sheet metal enclosure type, wall mounting suitable for , 3 phase, 415 volt, 50 hz, rp, , ML over load relay all including single phase preventer fittings complete including taking out all as specified and directed.
M&L for cutting/treeming grass, buses, and cleaning complete inside area of pump house and 2 meter outside fencing including cleaning of fencing from grass /treeming carefully taking proper precautions of electric cables, pipe lines, etc including using own T&P reqd at site, etc complete all as specifed and directed. (Approx area of pump house)
Supply, fabrication and fixing MS chennal/ pipe fitting/barrel piece /lateral pipe as per site requirement including nut, bolt, washer, welding etc and fibre board gasket complete and making joint leak proof including including taking out dismantling old structure complete all as specified and directed.
M&L for welding work of size 12 mm consider one welding job including cutting, jointing and all connected accessories all specified and directed.
Disconnecting/ Dismentling of submersible sewage disposal pump Set assy from its foundation at various place of Dronachal sewage pump house and transporting to civil workshop for repair complete and taking back after repairing, fixing to its existing position and making all connections.Dismentling and opening of pump assy for checking out defects. Taking out shaft from pump and carrying out lathe work on shaft for checking and making straightness. Taking out of old worn out brass impeller and M&L for filling material on worn out part , grinding, poilshing and carrying out complete lathe work, refixing on shaft and check for its smooth functioning and balancing.(Parts for following items shall be paid under relevent item here-in-after under as supply).
(a) 45/60 KW motor
(b) 30 KW motor
(c) 22 KW motor
(d) 15 KW motor
(e) 11 KW motor
(f) 2.2 KW motor
Taking out unserviceable spares and burnt copper binding wire complete. M&L for rewinding of Centrifugal/submersible motor / open well motorwith insulated copper winding wire including sleeves as per original company and replacement of worn out parts, including grinding & polishing of rotor sleeves and refixing, testing & transport charges complete all as specified & directed by EIC (Parts for following items shall be paid under relevent item here-in-after under as supply). (a) 1 HP to 60 HP Motor
Supply and fix the following parts of the submersible sewage pump and motor for capacity between 45/60 KW of original company as approved by Engineer-in-charge. ( Note :- .U/S Part other than as listed below of Pump if required to be replaced to make the pump functional is to be replaced by contractor. No extra payment shall be paid to contractor.)
(a) Bowl bush
(b) Impeller
(c) Neck ring
(d) Shaft sleeve
(e) Pump shaft
(f) Coupling
(g) Coupling key
(h) Impeller key
(j) Stud with nuts
(j) Thrust bearing
(k) Lower housing bush
(l) Upper housing bush
(m) Water seal mechanical type
(n) Rotor shaft sleave
(o) Drain plug
(p) CI Bowl
(q) Bearing Suitable for pump set
(r) Rotor Shaft
Supply and fix the following parts of the submersible /open well pump and motor for capacity between 20 to 30 KW of original company as approved by Engineer-in-charge. ( Note :- .U/S Part other than as listed below of Pump if required to be replaced to make the pump functional is to be replaced by contractor. No extra payment shall be paid to contractor.)
(a) Bowl bush
(b) Impeller
(c) Neck ring
(d) Shaft sleeve
(e) Pump shaft
(f) Coupling
(g) Coupling key
(h) Impeller key
(j) Stud with nuts
(j) Thrust bearing
(k) Lower housing bush
(l) Upper housing bush
(m) Rotor shaft sleave
(n) Drain plug
(o) Water seal
(p) CI Bowl
(q) Rotor Shaft
(r) Bearing Suitable for Existing Pump
Supply and fix the following parts of the centrigual Pump and motor for capacity 2 to 15 KW of original company as approved by Engineer-in-charge. ( Note :- .U/S Part other than as listed below of Pump if required to be replaced to make the pump functional is to be replaced by contractor. No extra payment shall be paid to contractor.)
(a) Bowl bush
(b) Impeller
(c) Neck ring
(d) Shaft sleeve
(e) Pump shaft
(f) Coupling
(g) Coupling key
(h) Impeller key
(j) Stud with nuts
(k) Thrust bearing
(l) Lower housing bush
(m) Upper housing bush
(n) Rotor shaft sleave
(o) Drain plug
(p) Water seal
(q) CI Bowl
(r) Rotor Shaft
(s) Bearing Suitable for Existing Pump
S&F in replacement to ON load Changeover Switch,Rotory type 100 Amp,415 Volt , TPN, front operated with out sheet metal enclosure suitable for mounting on existing panel as per sample and site requirement complete all as specified and directed.
S&F in replacement to ON load Changeover Switch,Rotory type 200 Amp,415 Volt , TPN, front operated with out sheet metal enclosure suitable for mounting on existing panel as per sample and site requirement complete all as specified and directed.
S&F in replacement to ON load Changeover Switch,Rotory type 63 Amp,415 Volt , TPN, front operated with out sheet metal enclosure suitable for mounting on existing panel as per sample and site requirement complete all as specified and directed.
S& F Bldg Security light 45 watt IP 65 Protection with clamp and braket size 50 mm medium class GI tubing complete with wiring all as specfied and directed.
M&L for installing GI strip of 32x6 mm dimensions and making proper arrangements for connection between earthing and Transformer/ equipment all as specified and directed by Engineer-in-charge.
Repair of outdoor type LT pannel board mounted on angle / PCC floor of any size and replacement of unserviceable switch/control gears and connector,indicator lamps, panel door lock etc including rewiring and extension of incoming and out going cables by opening of loops/making joints with same size cable and provisioning of cable lugs /thimbles as reqd including replacement of rusted sheet metal door with existing size MS sheets by necessary arc/gas welding / making cover as per suitable and removing all dirt, dust etc with the help of air blower and painting complete Panel board with one coat of synthetic enamel spray painting over a coat of red oxide primer of Panel Board of approved colour including writing of identification etc all as specified and directed by Engineer-in-Charge.
Note : (i) Necessary eqpt and safety measures, stasonary reqd for load balancing arranged by the contractor without any extra cost. (ii) Cost of New aluminium/Copper thimbles, earth and neutral link, insulator, hylem sheet, any type of screws,door locks any type as per site reqmt change under the job deemed to be included in the quoted rate. (iii) MCCB, MCB,Aluminium bus bar, indicator lamp, required for relacement shall be measured and paid serately in relevent item.
M&L in replacement LED Type indicating Lamp for indication of RYB-01 Set
M&L in replacement aluminium bus bar rating 200 Amps 25/6 mm including making whole suitable for panel with tape insulation of suitable colour in Phase RYB & neutral in Black colour complete all as specified and as directed by Engr-in-Charge.
Desludging sewage sump well at certain places of 10 mtr internal dia and depth exc 5 mtr but not exc 10 mtr, by mechanical method only. Disposal of sludge or foreign material etc. And sludge or foreign material through out from Dronachal station by own tansport to distance of not exceeding 15 KM from the sewage pump house incl necessary loading and unloding complete all as specified and directed by Eng-in-Charge. Note:- The contractor is responsible for all safety of men employed by him durying work at site.
Supply and fixing CI non raising type sluice valve with drilled flanged ends, stainless steel spindle with gun metal working parts with hand wheel, pressure type PN 1.6, including disconnection and removing the unsv sluice valves from the existing pipe line/ valve chamber for the size of 150 mm dia.
S&F in replacement Garden light, including LED lamp 9 Watt, 220 volt, 50 Hz , Approx height 2 ft , mounting arrangemet , clamp ,rcc pit of suitable size complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60×60cm×6mm thick, buried directly in ground (earth pit not less level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 25X4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 5 SSR including earth pit in any soil char coal common salt , 15 mm all around earth plate PCC (1:3:6) type culprit, with 40 x40x6 mm angle iron frame and PCC cover (1:2:4) type B1 , water pipe funnel and GI protection pipe light grade 15mm dia upto panel connecting earth lead to panel all as specified and directed by EIC. Note : Earth continuity conductor including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
M & L for concealed point wiring for one light/fan point with 1.50 sqmm (nominal area), FRLS PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade,ISI marked controlled by one one-way switch, drawn through and including concealed medium grade PVC conduit not less than 20 mm dia, ISI marked, with all accessories(PVC Casing and caping of size 25 mm , ISI marked with complete accessories to be used wherever wiring to be run on ceilings and concrete surfaces) including one run of 1.5 sqmm FRLS muti stranded copper conductor (Green colour cable) as earth continuity wire connected to common earth dolly, including sunk sheet steel terminal box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted with two coates of anti corrosive black bituminous paint over a coat of red oxide primer in and out sides and two coated of aluminium paint on internal surface , including laminated hylum sheet cover, ISI marked of Make" Hylem" for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note : Wiring to be done as per arroved colour code in IE rule.Rate includes chase cutting for concealed wiring
All as per item No. 41 here-in-before but for 3 pin socket outlet, 5 Amp on the same board with other switches, complete all as specified and directed.
All as per item No. 41 here-in-before, but for 3 pin 5 amp switch socket combination on independent board with other switch complete all as specified and directed.
All as per item No. 41 here-in-before but wiring with 2.5 Sq mm FRLS mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. .
S&F Polycarbonate switch piano, flush button, single pole, one way 5 Amp , 240 volts ISI marked,
Supply and fixing, Polycarbonate ceiling rose, surface type, 3 terminal, 240 , ISI marked,
Supply and fixing Polycarbonate socket outlet 2-in-1, 5 pin 5 Amps, 240 volts, flush type
S&F Polycarbonate switch socket combo outlet flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 230 volts complete as directed .
S&F, stepped type electronic fan regulator, Delux model, 100 watt, 240V, flush type.
Supply and fixing in lamp holder , PVC/Poly carbonate type with back plate suitable for batten fittings including 9 watt LED lamp, and all cnnected accessies.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 4.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25 mm dia, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surfaces/ recess complete all as specified and directed by EIC.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed by Engr-in-charge.
S&F MCB SPN 5 to 32 amps 10 KA , 'C' Curve including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-In-Charge.
S&F MCB SP 240 volts 5 to 32 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-In-Charge.
Taking down existing fitting & S&F in repairs LED tube light box type Highly durable surface mounted LED batten constructed of fire retardant engineering grade extruded plastic and decorative end caps. 22/25 Watt (reterofit type, T8 pattern, single side connection) 240 V, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, approx length 4 feet to be fixed in existing or new batten including taking down of existing tube light fitting and changing the wiring suitable for T8 LED tube light in existing tube light fitting complete.
S & F bulk head luminare weather proof, including one No. LED lamp 9W and connecting with copper flexible three core 23/0.0076 and all necessary fittings complete.
S&F LED Post top IP65 elegantly desingned die cast AL housing and high grade Al heat sink for efficient thermal magemant ,studiness and excelant corrosion resitance .3 Nos die cast AL arms are provided to suppoet the housing.poder coated black after phosphochromate treatment complete with wiring all as specfied and directed.
S&F first Aid box wooden type with all ascessories complete all as specfied and directed.
S&F Exhaust Fan 300 mm sweep metal body with louver complete metal body complete all as specified and directed by Engr-in-Charge.
Cutting holes suitable for fixing 300 mm sweep Exhaust fans through brickwalls built in cement mortar and making good around the holes in cement mortar 1:3 complete all as specified and directed.
M&L for painting on Sewage Pump house bldg with synthetic enamel paint all specified and directed.
S& F Security light 65 watt IP 65 Protection with clamp and braket size 50 mm medium class GI tubing complete with wiring all as specfied and directed.
Supply and Replacement in repair of aluminium strip 25 x 3.15mm with saddles and fixing screws, insulators rawal plugs etc for conductor for roof and fixed on wall upto test point all as specified.
Supply and fix in replacement of GI tubes light grade, galvanised, 20mm bore including necessary GI fittings, laid in trenches or under floor or fixed with poles/walls for fixing of air termination incl dismantling and taking down old existing unserviceable GI tubes light grade complete all as specified and directed.
Supply and fix in replacement of GI tubes medium grade, galvanised, 50 mm bore including necessary GI fittings, laid in trenches or under floor or fixed with poles/walls for fixing of air termination incl dismantling and taking down old existing unserviceable GI tubes light grade complete all as specified and directed.
Supply and fix in replacement of GI tubes medium grade, galvanised, 40 mm bore including necessary GI fittings, laid in trenches or under floor or fixed with poles/walls for fixing of air termination incl dismantling and taking down old existing unserviceable GI tubes light grade complete all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes:-
(a) 16 Sqmm 4 core
(b) 50 Sqmm 3.5 core
(c) 120 sqmm 3.5 core
S&F 5mm rubber insulation sheet all as specfied and directed by EIC.
Repair/Replacement of non clogging pump set 5 HP with starter complete all as specfied and directed.
M/s H V Infra Projects (BID ID -3101017)
MODI CORPORATION (BID ID -3109517)
PRADEEP TIWARI CONTRACTOR (BID ID -3124220)
UMESH ENTERPRISES (BID ID -3123791)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .